Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹18.1 L+₹14,286 (0.80%)Rejected-AOC | L2 | Rejected-AOC Being the other than lowest bidder | |
| 3 | L3₹19.0 L+₹1.0 L (5.58%)Rejected-AOC | L3 | Rejected-AOC Being the other than lowest bidder | |
| 4 | L4₹21.2 L+₹3.2 L (17.9%)Rejected-AOC | L4 | Rejected-AOC Being the other than lowest bidder | |
| 5 | L5₹22.6 L+₹4.6 L (25.8%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L5 | Rejected-AOC Being the other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
9 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
REPAIR AND MAINTENANCE OF STABLIZER, TRANSFORMER WITH CONNECTED SERVICE AT NAGROTA UNDER GE NAGROTA
2020_MES_403040_1
CWE/NGT-41/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Nagrota
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
Yes
GE NAGROTA
₹54,000
Yes
15 Feb 2021
12 Dec 2020
11 Jan 2021
12 Dec 2020
9 Jan 2021
26 Dec 2020
12 Dec 2020 - 19 Dec 2020
60 days
Amount
M&L for taking down transformers mounted on two/four pole structure or on platform / indoor floor mounted carefully from their position after removing electrical connection, earthing leads etc for executing necessary comprehensive preventive maintenance as well repairs necessiated, including to and fro transporting to MES store yard/contactor workshop, and refixing after execution of maintenance/repair to their original position or to other location as directed of capacity as under: -
(a) Step down transformer 11 KV/0.433 KV of any make of capacity 50 KVA to 160 KVA.
(b) All as per Srl item No. 1.01 above but of capacity exceeding 160 KVA but not exceeding 500 KVA
Labour, tools & plants only for opening the top cover of transformer out/in door type, step down 11 KV/0.433 KV of capacity 50 KVA to 160 KVA, lifting of core and winding, draining out transformer oil into container and keep aside for treatment and reuse, carry out strip inspection of core and windings for comprehensive routine, preventive maintenance and any other necessary repairs required to be executed. Refitting the core & windings after carry out necessary routine maintenance/preventive maintenance or repairs so ordered, making all electrical connections, providing sundry items i.e bolts, nuts & washers, reassembling the transformer complete, including testing and commissioning to the entire satisfaction of the Engineer-in-Charge, complete all as specified and as directed.
All as per Srl item No. 2 here-in-above but transformer of capacity exceeding 160 KVA but not exc 500 KVA Note for srl item No 2 & 3 above: Preventive maintenance/repairs so assessed shall be measured and paid for separately under the respective item of sch 'A' here-in-after. However the rates quoted are deemed to include for all type of checks to be conducted to assess the repairs and preventive maintenance, dismantling, lifting, core with winding, relowering of core with winding refitting of transformer, making electrical connection, commissing and testing complete after repairs.
M&L for dismantling core, taking out damaged coils (HV Coils) from its position for replacement, including supplying and fixing new winded coils with super enamelled copper winding wires of required gauge, number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed by the Engr-in-Charge.
M&L for taking out damaged coils (LV Coils) from its position for replacement including supplying and fixing new winded coils with cotton braided copper wire or strip of appropriate size (thickness & width) number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed by the Engr-in-Charge.
Taking out HV procelain bushes from transformers for replacement being damaged, including supply and fixing new HV porcelain, viterous white, brown or green of voltage grade 11000 V bushes to suit the size of transformers of different makes transformer of capacity 50 KVA upto 500 KVA indoor.
Taking out LV procelain bushes from transformers for replacement being damaged, including supply and fixing new HV porcelain, viterous white, brown or green of voltage grade 1100 V bushes to suit the size of transformers of different makes transformer of capacity 50 KVA upto 500 KVA indoor/out door.
Taking out worn out HV metallic alloy(brass/gun metal) bush rods, including supply and fixing new HV metallic alloy (gun metal/brass) bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of capacity 50 KVA to 160 KVA
All as per Srl item No. 8 here-in-above but for transformer of capacity exceeding 160 KVA but not exceeding 500 KVA.
Taking out worn out LV metallic alloy (brass/gun metal) bush rods, including supply & fixing new LV metallic alloy (gun metal/brass) bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of capacity 50 KVA to 160 KVA
All as per Srl item No. 10 here-in-above but for transformer of capacity exceeding 160 KVA but not exc 500 KVA
S&F cork sheet 6mm thick gasket packing to transformers top cover of various capacity upto 500 KVA outdoor / indoor.
Filteration, dehydration of transformer oil as drained out from transformer vide sch 'A' srl item No 2 & 3 here-in-above to make the oil fit for reuse by improving its dielectric strength not less than 40 KV. Dielctric strength of oil below 40 KV shall be replaced with new oil (new oil for toping/or for replacement shall be measured and paid separately under appropriate item of sch 'A') here-in-after.
Supply, treating (dehydrating), filling new transformer oil in transformers for topping up levels or for replacement of unfit oil. New oil having dielectric strength not less than 60 KV and shall be conforming to IS 335.
Taking out old breathers from transformer, supplying and fixing new breather duly filled with activated agent i.e silica gel for transformer of capacity 50 KVA to 200 KVA
All as per Srl item No 15 here-in-above but for transformer of capacity exceeding 200 KVA but not exceeding 500 KVA
Supply, fixing, commissioning & testing of dial type temp gauge 100mm dia having dial range 0-100ºC complete with thermostat built in switch complete all as specified and directed.
M & L complete for taking out unserviceable tap changing gear for replacement, including supply & fixing, making connections, testing & commissioning new tap changing gears in transformers of any description / rating and make complete all as specified and as directed.
M & L complete for denting out damaged external cooling tube of transformer & bring them to their original shape, of any type and description against of capacity 50 KVA to 500 KVA.
M & L welding to iron surface sheet steel in cooling tube/ body of transformer of any description to prevent leakages of oil , welding in repairs exceeding 2.5 cm but n.exc 5 cm in length, thickness of metal to be welded n.exc 6mm.
M&L for Painting to transformers old painted surface of steel after cleaning, scraping and preparing and filling cavities and providing one coat of synthetic enameled grey paint with spray gun process to transformer of capacity 50 to 160 KVA indoor / outdoor type.
All as per Srl item No. 21 above but for transformer of capacity exceeding 160 KVA but not exceeding 500 KVA.
Disconnecting and removing to workshop, opening for repair automatic voltage stabilizer for automatic operation air cooled servo controlled type input voltage 260-440V and output voltage 420 V of capacity 10 KVA to 50 KVA complete all as specified and as directed. Note : Replacement of the parts if any found worn out/defective shall be measured and paid for separately .
All as per Srl item No. 23 above but of capacity 75 KVA to 300 KVA.
Supply and Fixing of new dimmer coil with super enameled copper winding wire including varnishing tapping and insulating material to get same capacity of 10 KVA to 150 KVA
All as per Srl item No. 25 above but of cap 150 KVA to 300 KVA (unbalanced type)
Replacement of electronic circuit plate complete with DC transformers (10 KVA to 50 KVA) complete (PCB cold)
Dismantling of old carbon brush with carbon holder including supplying and fixing new one complete
Replacement of brass studs fixed for input and output of stabilizer with brass nuts for upto 50 KVA capacity
All as per srl item No 29 above but of capacity 75 KVA to 300 KVA
Cleaning, preparing and painting with one coat of grey samson paint to tubular pole of HT 11 KV complete and aluminium paint to poles, cross arms, MS channels, angle iron, frame work bracing of pole and writing of HT feeder name with black enemelled paint from stencil complete all as directed by Engineer-in-Charge.
Taking down transformer of any size, any capacity and reinstalling after repair of platform (including lifting of transformer from the existing platform and reinstalling of transformer on new platform).
M&L of transformer platforms of size 2.50 m x 2.50m x 1.20m with following specifications as under a) Brick work in sub class B brick old size burnt clay bricks exc 6m mean radius on plan in cement mortar 1:4 complete all as specified and directed b) PCC 1:3:6 as in foundation filling and mass concrete c) Stone boulder filling not exceeding 63mm including hand packing and ramming complete d) PCC 1:2 :4 as in flooring / top surface of platform complete e) Plastering to brick work in CM 1:4 complete f) Angle iron as in post for fencing g) Chain link fencing of any size 4 mm dia GI wire
Mild steel framed work as in framed structure (around 4 pole/2 pole/ LT panel/ Transformer) guard bars, framed balusters and similar works complete including PCC work as in foundation complete all as specified.
Expended metal cut to length, bend to required shape, weight not less than 4 kg/Sqm and laying with and including annealed MS wire or welded to steel members complete all as specified.
M&L Broken stone or boulder hard core not exc 63 mm deposited, spread and levelled in layer not exceeding 15 cm thick watered and rammed to a true surface complete all as specified
Material and labour for spreading and levelling evenly (any thickness) 20 mm graded stone aggregates complete all as specified and directed.
Material and labour for spreading and levelling evenly (any thickness) 40 mm graded stone aggregates complete all as specified and directed.
Labour & tools for trimming tree branches upto 100 mm girth of any location around existing HT/LT OH lines giving clearance of 1.5 m on all sides after arranging shut down and taking all precaution while working on lines including all T&P required for the purpose complete all as specified and directed by Engineer in charge. (Note:- Trimming of tree branches irrespective of numbers in each tree shall be measured as one unit).
M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to GI strip 25x4mm (as earth lead wire), by means of bolt, nuts , check nuts and washer of GI and earth wire protected by provision of GI pipe medium grade, 15mm bore upto 7.5 mtr length including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 17mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No. 5 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Galvanised iron strip of size 25x 4 mm for earth continuity conductor or main earthing lead fixed to wall, burried in ground, fixed along with poles, complete all as specified.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed. Make : Denson/ Raychem / M-Seal or equivalent from the makes given in Particular Specifications.
All as per Srl item No. 42 here in before but for cable of cross sectional area 120 to 185 sqmm indoor type complete all as specified and directed.
All as per Srl item No. 42 here in before but for cable of cross sectional area 240 to 300 sqmm indoor type complete all as specified and directed.
All as per Srl item No. 42 here in before but for cable of cross sectional area 50 to 95 sqmm outdoor type complete all as specified and directed.
All as per Srl item No. 42 here in before but for cable of cross sectional area 120 to 185 sqmm outdoor type complete all as specified and directed.
All as per Srl item No. 42 here in before but for cable of cross sectional area 240 to 300 sqmm outdoor type complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
All as per Srl item No. 48 here in before but for cable of cross sectional area 120 to 185 sqmm indoor type
25 mm thick Synthetic insulating mat suitable for 11000 volt grade (ISI Marked) of size 2m x 1m x 25mm complete all as specified and directed.
M&L Switch air break gang operated (Swing out expulsion fuse insulators), triple pole mechnical operated from ground level mounted on insulator and steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground level conforming to IS 1818 of 1972 and continuous current rating upto 200 amp and volt 11 KV complete in repairs all as specified including dismantling existing air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism any type and size.
M&L Lightning arrestor expulsion type comply with IS 3070 Part I 1985 for alternating current system multple spark gap suitable for voltage grade 11000 volt discharge cap 65 KA complete with all fittings and all as specified.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole/stays etc complete all as specified
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole/stays etc complete all as specified
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping/above ground level around the pole etc complete all as specified.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints,type 410 SP-55 (11.0 metres long) including disconnecting and taking out old poles of any type and size complete all as directed .
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed including dismantling and taking out damaged/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed.
M&L Stay assembly galvanised iron complete with accessories stay rod 20 mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stary strand wire 7/4mm dia complete all as specified and shown in EP plate No 1 of SSR 2009 .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for errection of HT/LT poles laying of HT/LT UG cables and for provision of stay assembly complete
Excavating in trenches exceeding 1.5m but not exceeding 3m in depth for foundation etc not exceeding 10 Sqm on plan for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point and entire satisfaction of Engnr-in-Charge complete all as specified and directed
M&L Sand dry clean as cushioning to underground electric cable provided with a layer of 80mm deep before laying and 150mm over cable laid in trenches complete all as speficied. Note:- Punned thickness of the sand shall be measured.
M&L Brick over cable laid in trenches as protection to cables with width equal to the length of bricks with well burnt sub class 'B' bricks (old size) complete all as specified.
Supply, Laying, jointing and testing of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armoured electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade and cross sectional area 95 sqmm 3 core conforming to latest IS and ISI marked including taking down old unserviceable cable of any size and capacity complete all as specified and directed by Engr-in-Charge
Supply and Fixing of root indicator for HT Cable marked with HT Cable along the route of laying of cabe at the distance of every 10 mtr complete all as specified and directed by Engr In Charge.
Note:- Schedule of credit Rs. 2,11,586.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
ASHOKA ENGINEERS AND BUILDERS
proach associates
M/S MANJIT SINGH AND SONS
R K BUILDERS
darshan kumar gandhi
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .