Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.1 L+₹90,471.25 (4.98%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹19.5 L+₹1.3 L (7.22%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹21.4 L+₹3.2 L (17.7%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Aug 2022, 6:00 pmClosed
GE Satwari
GE Satwari Jammu
REPAIR/ MAINTENANCE OF WATER SUPPLY DISTRIBUTION CI/DI/GI PIPE LINES UNDER AGE E/M MH UNDER GE SATWARI
2022_MES_535606_1
GEJM-33/2022-23
Open Tender
Civil Works
Item Rate
270 days
Satwari Cantt
E Class Cat a ii
9 documents required · 9 mandatory
₹500
GE Satwari
₹40,000
Yes
9 Feb 2023
4 Jul 2022
5 Aug 2022
4 Jul 2022
3 Aug 2022
22 Jul 2022
Amount
M&L for arresting leakages in GI pipe line of size 15/20mm bore by cutting, threading, cleaning including inserting of new fittings viz. nipples, unions, ferrule, reducer, elbows, tee, sockets, bends, pipe lengths, etc. as required including necessary arrangement to work viz. staging, etc. along heights of buildings upto (G+3) complete all as specified and as directed
M&L for arresting leakages in GI pipe line of size 25mm bore by cutting, threading, cleaning including inserting of new fittings viz. nipples, unions, ferrule, reducer, elbows, tee, sockets, bends, pipe lengths, etc. as required including necessary arrangement to work viz. staging, etc. along heights of buildings upto (G+3) complete all as specified and as directed
M&L for arresting leakages in GI pipe line of size 40/50mm bore by cutting, threading, cleaning including inserting of new fittings viz. nipples, unions, ferrule, reducer, elbows, tee, sockets, bends, pipe lengths, etc. as required including necessary arrangement to work viz. staging, etc. along heights of buildings upto (G+3) complete all as specified and as directed
M&L for arresting leakages in GI pipe line of size 80mm bore by cutting, threading, cleaning including inserting of new fittings viz. nipples, unions, ferrule, reducer, elbows, tee, sockets, bends, pipe lengths, etc. as required complete all as specified and as directed
M&L for arresting leakages in GI pipe line of size 100mm bore by cutting, threading, cleaning including inserting of new fittings viz. nipples, unions, ferrule, reducer, elbows, tee, sockets, bends, pipe lengths, etc. as required complete all as specified and as directed
M&L for arresting leakages in CI/DI pipeline of size 80/100mm bore by plugging leakage with necessary cutting making arrangement for inserting necessary sized tail piece, collar, ferrule, plug , clamp, etc. for restoring water supply complete all as secified and as directed
M&L for arresting leakages in CI/DI pipeline of size 150mm bore by plugging leakage with necessary cutting making arrangement for inserting necessary sized tail piece, collar, ferrule, plug , clamp, etc. for restoring water supply complete all as secified and as directed
M&L for arresting leakages in CI/DI pipeline of size 200mm bore by plugging leakage with necessary cutting making arrangement for inserting necessary sized tail piece, collar, ferrule, plug , clamp, etc. for restoring water supply complete all as secified and as directed
Notes for serial item Nos. 01 to 8: (a) Entire work done against items shall be measured as one unit (b) Cost of GI fittings viz. nipple, unions, ferrule, elbows, tee, sockets, tail piece, straights, bends, increasing / decreasing tapering ends or double socket fittings, etc. and pipe upto 1 mtr length as used in repair against the item and excavation / earthwork, PCC work have supposed to be included in respective items. (c) only cost of CI special will be measured separately undre relevent items as below. (d) Breakdown / fault will be communicated over any means viz. phone / whatsapp /sms / email / complaint slip, etc. and the fault has to be attended within 3hrs of intimation and work shall be done on high priority to restore services. Failure to attend such complaints / faults within 3hours a recovery @Rs 300/hour will be imposed. Such recoveries shall be implemented immediately on subsequent RAR.
Supply and fixing in replacement Gun metal Gate valve, screwed both ends for iron pipe of 20 mm bore ISI marked. all as specified and directed.
Supply and fixing in replacement Gun metal Gate valve, screwed both ends for iron pipe of 25 mm bore ISI marked. all as specified and directed.
Supply and fixing in replacement Gun metal Gate valve, screwed both ends for iron pipe of 40 mm bore ISI marked. all as specified and directed
Supply and fixing in replacement Gun metal gate valve, screwed both ends for iron pipe of 50 mm bore ISI marked. all as specified and directed.
Excavation in trenches for foundation, laying of pipes n.exc 1.5m width and n.exc 1.5m in depth for laying of under ground pipes line and getting out in any type of soil complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified.
Removing excavated surplus materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Drilling and tapping (15mm to 25mm dia) in existing 150mm/100mm/80mm bore GI/CI pipe line for taking branch connections including providing brass ferule (15mm to 25mm dia) & required fitting (excavation and earth work will be measured & paid for separetly) complete all as specified and directed.
Burning out old leaking lead joints in position and removing old lead for 80mm bore CI pipe/ fittings and keeping aside for further disposal (earth work shall be measured and paid separately).
Description all as per Srl item No 18 here in before but for 100mm bore pipe
Description all as per Srl item No 18 here in before but for 150mm bore pipe
Material and labour for run lead joint including all jointing material such as lead, spun yarn etc for 80mm bore cast iron spigot & socketed pipe & fittings. (Exc earth work will be measured & paid separetely)
Description all as per Srl item No 21 here in before but for 100mm bore cast iron spigot & socketed pipe & fittings.
Description all as per Srl item No 21 here in before but for 150mm bore cast iron spigot & socketed pipe & fittings.
Supplying, laying, jointing & testing galvanised steel tubing 15 mm bore medium grade with screwed joint together with all fitting such as bends, elbows,tees,short pieces and union etc laid in trenches including taking out old unserviceable,cracked steel tubing including all fittings complete all as specified and directed. Note:- Earth work shall be measured and paid separately under respective item of shedule 'A'.
Description all as per Srl item No 24 here in before but for 20mm bore pipe.
Description all as per Srl item No 24 here in before but for 25mm bore pipe.
Description all as per Srl item No 24 here in before but for 40mm bore pipe.
Description all as per Srl item No 24 here in before but for 50mm bore pipe.
Description all as per Srl item No 24 here in before but for 80mm bore pipe.
Description all as per Srl item No 24 here in before but for 100mm bore pipe.
Supplying, laying, jointing & testing DI pipes with spigot and socket ends centrifugally cast class 'LA' in any length 100mm bore all as specified and directed. Note: 1. Rate inclusive of Cost of tyton joint. 2. Lead joints, earth work for re routing & CI fittings shall be measured and paid separately).
Description all as per Srl item No 31 here in before out for 150mm bore pipe.
Supplying, laying, jointing & testing MS pipes with flanged ends centrifugally cast class 'LA' in any length of dia 150mm bore all as specified and directed. Note: Rate includes cutting, welding, flanged,nut, bolts, washers etc as per site requirement).
Supplying, laying, jointing & testing MS pipes with flanged ends centrifugally cast class 'LA' in any length of dia 200mm bore all as specified and directed. Note: Rate includes cutting, welding, flanged,nut, bolts, washers etc as per site requirement).
Material and labour for Cast iron fitting for CI spigot socketed/ flanged pipe bend (any type radius and angle) tapers any type (straight, bends increasing, decreasing or double socket etc) tee pieces, single branch 'Y' junction double branch cross (all socket or socket spigot or flanged) collars, cap and plugs upto 150 mm bore connection pieces one end flanged and other socket or spigot and bell mouth piece one end flanged and other end tapering as bell mouth complete all as specified and directed.
Supply and fix in replacement stainless steel spindle alongwith wedge nut suitable for cast iron sluice valve 150 mm dia of any make as existing alongwith taking out old spindle all as specified and directed.
Description all as per item No 36 here in before but 100mm.
Description all as per item No 36 here in before but 80mm.
Supply and fixing in replacement Rubber gasket joint 3 mm thick with 4/6 hole for flanged joint 80 mm dia complete all as specified and directed.
Supply and fixing in replacement Rubber gasket joint 3 mm thick for flanged joint 100 mm dia complete all as specified and directed.
Supply and fixing in replacement Rubber gasket joint 3 mm thick for flanged joint 150 mm dia complete all as specified and directed.
BMMJ TRADERS AND ENGINEERS
M/S Chib Engineers
M/S S K Electricals Regd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .