Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.5 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹87.6 L+₹11.1 L (14.5%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹91.2 L+₹14.7 L (19.3%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹92.4 L+₹15.9 L (20.8%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹1.0 Cr+₹28.1 L (36.7%)Rejected-Finance | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹88 L
EMD Value
₹1.6 L
Closing Date
23 Jul 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPLACEMENT OF OLD UNSERVICEABLE DOUBLE SKIN AIR HANDLING UNITS WITH ITS ELECTRICAL PANELS AND ACCESSORIES AGAINST BER UNDER SPL REPAIRS AT INHS ASVINI UNDER AGE I ASVINI COLABA MUMBAI
2024_MES_662766_1
8054/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
270 days
AGE (I) Asvini
As per tender documents
7 documents required · 7 mandatory
₹1,000
Yes
AGE (I) Asvini
₹1.6 L
Yes
CWE (NW) Mumbai
25 Nov 2024
28 Jun 2024
25 Jul 2024
28 Jun 2024
23 Jul 2024
18 Jul 2024
28 Jun 2024 - 11 Jul 2024
11 Jul 2024
Amount
Ditto - all as per Item No. 1.00 above but capacity 3000 CFM /ESP-15MM / minimum 10 TR / 9 KW HEATING / 6 ROW DEEP
Ditto - all as per Item No. 1.00 above but capacity 4000 CFM /ESP-15MM / Minimum 10 TR / 9 KW HEATING / 6 ROW DEEP
Ditto - all as per Item No. 1.00 above but capacity 5000 CFM / ESP-15MM / Minimum 12 TR / 12 KW HEATING / 6 ROW DEEP
Ditto - all as per Item No. 1.00 above but capacity 6000 CFM ESP-15MM / Minimum 15 TR / 18 KW HEATING / 6 ROW DEEP
Ditto - all as per Item No. 1.00 above but capacity 12000 CFM ESP-15MM / Minimum 30 TR / 36 KW HEATING / 8 ROW DEEP
Ditto - all as per Item No. 1.00 above but capacity 20000 CFM ESP-15MM / minimum 50 TR / 36 KW HEATING / 8 ROW DEEP
Supply & fix 65mm NB dia ,3 - Way Actuator globe valve by pass type with Thermostat & complete wiring of having size of 1/2'' to 3'' complete all as specified & as directed.
Ditto - all as per Item No. 8.00 above but 80mm NB dia.
Ditto - all as per Item No. 8.00 above but 100mm NB dia.
Taking down old unserviceable MS pipes and supply, lay, welding & testing 65mm bore Insulated Chilled Water MS pipes of C Class heavy grade with all fittings laid in floors or fixed to wall & ceillings with suitable size GI clamps insulated with Class O Nitrile rubber slab 32 mm thick with and including applying compound & GI cladding with 26 gauge GI sheet complete all as specified & as directed.
Taking down old unserviceable MS pipes and supply, lay, welding & testing 80mm bore Insulated Chilled Water MS pipes of C Class heavy grade with all fittings laid in floors or fixed to wall & ceillings with suitable size GI clamps insulated with Class O Nitrile rubber slab 32 mm thick with and including applying compound & GI cladding with 26 gauge GI sheet complete all as specified & as directed.
Taking down old unserviceable MS pipes and supply, lay, welding & testing 100mm bore Insulated Chilled Water MS pipes of C Class heavy grade with all fittings laid in floors or fixed to wall & ceillings with suitable size GI clamps insulated with Class O Nitrile rubber slab 32 mm thick with and including applying compound & GI cladding with 26 gauge GI sheet complete all as specified & as directed.
Material & Labour for Insulation of MS pipe of size 65 mm bore with PUF slab 40mm thick with and including applying bituminous compound and Damper sheet of suitable size complete all as specified and as directed by Engr-In-charge. Note: RCC slabs shall be removed by contractor and then refixing the same without damage after completion of the work as directed by Engr-in-charge and quoted rate shall deemed to be included the item.
Supply and fixing 65mm bore CI Butter fly valve (ISI Marked) slim seal design with nitrile rubber lined seal with clutch lever (P16) conforming to IS 13095 complete all as specified and directed.
Supply and fixing 80mm bore CI Butter fly valve (ISI Marked) slim seal design with nitrile rubber lined seal with clutch lever (P16) conforming to IS 13095 complete all as specified and directed.
Supply and fixing 100mm bore CI Butter fly valve (ISI Marked) slim seal design with nitrile rubber lined seal with clutch lever (P16) conforming to IS 13095 complete all as specified and directed.
Supply & errecting factory fabricated rectangular / square duct made out of 24 gauge GI sheet in L shaped hollow profile including all accessories such as corner, carraige bolt hangers, gasket & seal the longitudinal joints with and including approved sealent complete all as specified & directed by Engr-in-Charge.
Taking down old rectangular square duct including insulation, wire net & all connected accessories and making good disturbed surfaces as per existing complete all as specified & directed by Engr-in-charge.
Taking down old unserviceable/deteriorated Nitrille rubber class O insulation of one layer of 19mm thickness sticked on surface by using approved adhesive complete all as directed by Engineer-in-Charge.
Material & Labour for Nitrile Rubber insulation of one layer of 19mm thickness sticking on surface by using approved adhesive & sealing the joints by weather proof tape complete all as specified & directed.
Taking down old unserviceable AHU Electric panels and Supply, installation, Testing & commissioning of AHU cubical type indoor mounting panel, factory fabricated, powder coated. Modular compartmentalized with IP 42 protection, dead front dust & vermin proof, wall mounting made out of 2mm thick MS sheet LT Panel steel clad switchboard suitable for use at 415 Volts, 3 phase 4 wire 50 cycle system comprising the following: Note - i) The quoted rate shall include DPR operated Variable speed arrangement (V.F.D) in weather proof enclosure complete with incoming electrical isolator for supply & fix exhaust air fan to allow for constant air volume delivery at all filter pressure drop conditions including pressure drop sensors with alarm system. ii) The quoted rate shall also includes incomer electrical isolator and further distribution including suitable size cable, VFDs, starters, By Pass Starter for VFD etc as required and as described above.The static should be verified as per site. All the cable should be laid on perforated/ladder type GI tray. iii) Contractor shall submit the Electric panel drawing after visiting the site for approval of AGE(I).
INCOMING a) Aluminium Busbar 150A capacity b) MCCB 3P 63A 25KA - 01 No c) VAF Meter 96/96 - 01 No d) RYB Indicator Lamps with MCB - 01 Set
OUTGOING a) 32A TP MCB 10 KA - 01 No (For AHU Motor) b) 63A TP MCB 10 KA - 01 No (for Heater) c) VFD Suitable for 7.5 to 10 HP - 01 No (for AHU Motor) d) Star delta starter suitable for 7.5 HP to 10 HP Motor - 01 No e) Provision of Control circuit with suitable size copper conductor cable. f) All other safety accessories like Relays, ON/OFF buttons, Single phase preventer & Connected copper wiring.
Taking down old U/s AHU Electric panels and Supply, installation, Testing & commissioning of AHU cubical type indoor mounting panel, factory fabricated, powder coated. Modular compartmentalized with IP 42 protection, dead front dust & vermin proof, wall mounting made out of 2mm thick MS sheet LT Panel steel clad switchboard suitable for use at 415 Volts, 3 phase 4 wire 50 cycle system comprising the following: Note - i) The quoted rate shall include DPR operated Variable speed arrangement (V.F.D) in weather proof enclosure complete with incoming electrical isolator for supply & fix exhaust air fan to allow for constant air volume delivery at all filter pressure drop conditions including pressure drop sensors with alarm system. ii) The quoted rate shall also includes incomer electrical isolator and further distribution including suitable size cable, VFDs, starters, By Pass Starter for VFD etc as required and as described above.The static should be verified as per site. All the cable should be laid on perforated/ladder type GI tray. iii) Contractor shall submit the Electric panel drawing after visiting the site for approval of AGE(I).
INCOMING a) Aluminium Busbar 200A capacity b) MCCB 3P 160A 25KA - 01 No c) VAF Meter 96/96 - 01 No d) RYB Indicator Lamps with MCB - 01 Set
OUTGOING a) 63A TP MCB 10 KA - 01 No (For AHU Motor) b) 63A TP MCB 10 KA - 02 Nos (for Heater each bank) c) VFD Suitable for 7.5 to 10 HP - 01 No (for AHU Motor) d) Star delta starter suitable for 7.5 HP to 10 HP Motor - 01 No e) Provision of Control circuit with suitable size copper conductor cable.. f) All other safety accessories like Relays, ON/OFF buttons, Single phase preventer & Connected copper wiring.
Supply, laying, jointing, connecting & testing 6 Sqmm x 4 core XLPE insulated, armoured, PVC sheated heavy duty ,1100V grade, aluminium conductor cable fixed on wall, ceiling with suitable size of GI clamps including taking down old cable complete all as specified & directed.
Supply, laying, jointing, connecting & testing 4 Sqmm x 3 core XLPE insulated, armoured, PVC sheated heavy duty ,1100V grade, aluminium conductor cable fixed on wall, ceiling with suitable size of GI clamps including taking down old cable complete all as specified & directed.
Excavating in trenches n exc 1.5m wide & n exc 1.5m in depth; for foundation, etc. or for manholes n.exc.10 Sqm on plan and n.exc.1.5m in depth and getting out in any type of soil complete all as specified and directed by the Engr-in-charge
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed by the Engr-in-charge
Returning filling in , including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by the Engr-in-charge
Shree Ayyappa Engineering (BID ID -3071879)
Darpan Construction (BID ID -3071561)
pk Enterprises (BID ID -3071487)
somnath engineering corporation (BID ID -3070179)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .