Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.9 LAccepted-AOC | L1 | Accepted-AOC due to L1 | |
| 2 | Not Admitted-Fee/PreQual/Technical UTTAR PRADESH UP | GORAKHPUR | UTTAR PRADESH | 273001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 3 | Not Admitted-Fee/PreQual/Technical SBI MIRZAPUR SBI MAIN BRANCH 1ST FLOOR DUNKELNGANJ MIRZAPUR 231001 | MIRZAPUR | MIRZAPUR | UTTAR PRADESH | 231001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
12 Jul 2023, 2:00 pmClosed
SE IWC MIRZAPUR
SE IWC IRRIGATION COLONY FATHA MIRZAPUR
Renovation of AE Quarter, J.E. Quarter And Clerical staff quarter of Irrigation Construction Division, Robertsganj in district
2023_UPIDC_813191_2
NIT04/SE/2023-24
Open Tender
Civil Works - Buildings
Item Wise
180 days
SONEBHADRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,354
₹1.5 L
28 Nov 2023
5 Jul 2023
12 Jul 2023
5 Jul 2023
12 Jul 2023
5 Jul 2023
Amount
Dismentalling old plaster and racking out joints
Cement plastering on Brick masonry upto 12 mm thickness in 1:4 cement mortor with coarse sand
Dismentaling of door or window leaves including stacking of materials as dir. By eng. In charge.
Supplying Making and fixing of 30 to 32 mm thick commercial quality ply wood flush shutters including fixing wooden cleats and stops, adjustment of hinges, bolts, locks handles springs and other fitting but excluding their supply and including painting with two coat of black Japan on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally. as dir. By eng. In charge.
Painting on wooden suefesh two coat of synthetic enemal paint on New surface with superior quality approved make such as luxol Higloss, apcolite including cost of all material, labour T&P etc. required for proper completion of work.
Supplyng & fixing Mosquito Jali with Sheesam wood batten Arround the jali,batten, nail,screen etc requared for proper complation of the work.as dir. By eng. In charge
Scrapping old white wash / Colour wash / distemper cement paint including disposal of refuse as directed by the Engineer-in-charge.
Distempering two coats of oil bound distemper of approved make of Burber, Jension & Nicholcsen, Shalimar, Asian, Nerolac, over one priming coat of cement primer on new surface after thoroughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even with plaster of paris / whiting and sand papered smooth including cost of all material, labour T & P etc. required for proper completion of work.
Finishing Exaternal wall with two coat of water proof cement pant of approved quality on previously old treated surface with this paint to give an even shade after thoroughly brushing the surface to remove all, dirt and remains loose powdered materials including curing and cost of all materials.
Removing old paint from Steel/Wooden surface with paint remover of approved and making the surface even including cost of all material, labour, T&P etc. required for proper completion of work
Painting on steel surfesh two coat of synthetic enemal paint on old surface with superior quality approved make such as luxol Higloss, apcolite including cost of all material, labour, T&P etc. required for proper complition of work
Providing and fixing vetrifield tiles 600 x600 mm 9mm thick (dark) shade somany/ kajariya/jonson /orient make fixing fine sand 1:3 Cm
Dismantling cement concrete or brick or granolithic floor including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 M
Providing & Laying 4 cm thick C.C. (1 : 2 : 4) Flooring Without base concrete / Cum with machinary mixing.
Supply and laying of 80 mm thick I shaped mechnicly compressed inter locking cement concrete paver block manufacture by high pressure & controlled vibration machine having plan dimention 200 x(160+120 mm) with minimum 5mm thick topping of op cement mixed with marble powder infront of subdivision and division office including cost of all material ,labour ,T&P etc
Supplying And Fixing of 10 cm internal dia PVC (ISI) down pipes complete with rose heade bends,and grating and including supply of necessary M.S. clamp 25 cmx 3 mm fixed to wall wit and including supply of 15 cm Long 6 mm dia nails all materials, labour T&P etc. required for proper complation of the work and also including repair of plaster,pointing etc.
Wring point for light with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in 2 mm thick PVC conduit pipe concealed in the wall camplete with 1.5 sq. mm. earth wire drawn inside the conduit & piano type switch, ceiling rose on 3 mm thick phenolic laminated bakelite sheet etc. complete in all respects.
Wring point for plug with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in 2 mm thick PVC conduit pipe concealed in the wall camplete with 1.5 sq. mm. earth wire drawn inside the conduit & piano type switch & 5 pin socket on 3 mm thick phenolic laminated bakelite sheet etc. complete in all respects.
Wring point for fan with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in 2 mm thick PVC conduit pipe concealed in the wall camplete with 1.5 sq. mm. earth wire drawn inside the conduit & piano type switch, ceiling rose on 3 mm thick phenolic laminated bakelite sheet etc. complete in all respects.
Wiring point for exhaust fan with 1.5 sq mm FR PVC insulated multistand single core copper conductor cable in 2 mm thick PVC conduit pipe concealed in the wall complete with 1.5 sq. mm earth wire drawn inside the conduit & piano type switch 15 amp. on 3 mm thick phenolic laminated.
S/F of 6/108/16/20/25/32 Amp. MCB Complete in the all respect.
S/F surface/flush mounting 12 way SPN Distribution board without MCB complete in all respect in all respect.
S/F surface/flush mounting 8 way SPN Distribution board without MCB complete in all respect in all respect.
S/F surface/flush mounting 4 way SPN Distribution board without MCB complete in all respect in all respect.
S/F approved make of flourescent single tube, batten type fitting complete with copper wound choke, starter lamp holder complte duly wired etc. but with tube.
Erection and testing of ceiling fan and regulator etc. Excluding supply of down rod, complete in all respect.
Suppplying and fixing of Water storage tank (500 Ltr.) with ball valve 20mm dia, Including all cost of materials, Labour, T&P etc. required for proper complition of work. as dir. By eng. In charge.
Providing and fixing of white Vitreous china W/C squatting pan (Indian Type) of 580x440 mm dia, Including all cost of materials, Labour, T&P etc. as directed by Engineer in charge.
Fixing 100 mm size 'P' or 'S' trap for water closet squatting pan including joingting the trap with the pan and pipe in cement mortor 1:1 (1 Cement:1 Fine sand)
Providing and fixing of Flushing Cistern P.V.C. 10 LTR Capacity (Low Level) white (with Fittings, accessories and flush pipe) Including all cost of materials, Labour, T&P etc. required for proper complition of work
Filling of earth around of Residence for making proper surface complete with all respect labour T&P etc.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through theauthorised applicator of the manufacturer of membrane :14.91.1 3 mm thick
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .