Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC Approved by Accepting officer | |
| 2 | L2₹5.3 L+₹83,050 (18.5%)Rejected-Finance ANAND NAGAR ROAD NO 4 RAJAKHEDI MAKRONIA SAUGOR MP | SAUGOR | SAUGOR | MP | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹5.9 L+₹1.4 L (32.2%)Rejected-Finance BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹5.9 L+₹1.4 L (32.2%)Rejected-Finance WARD NO 36 CHAUBEY COLONY NARSINGHGARHPURWA CHHATARPUR MADHYA PRADESH 471001 | CHHATARPUR | MADHYA PRADESH | 471001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹5.9 L+₹1.4 L (32.3%)Rejected-Finance NEAR MPEB OFFICE DHANA DISTT SAUGOR MP 470228 | DHANA | SAUGOR | MP | 470228 | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | dipangashu barick and associates L3 | Pandey Construction and Engrs L2 | M/S JAINENDRA KUMAR JAIN L6 | m/s mahendra kumar khare contractor L4 | SUNIL KUMAR KORPAL L1 | siddhant construction L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Cleaning/desilting of man holes and sewage line of any diameter upto 200mm dia pipe by roding etc and subsequently bamboo split tied with rope through the pipe from manhole to manhole and cleaning the pipe clean for carry flow of sewage also getting out solid/liquid materials from manholes of any size and any depth including taking up and refixing of manhole cover in position and removal of sewage out of MD land, complete all as specified and directed by Engineer-in-charge.
Note:- (length of sewage line will be measured including manhole) | 8,000 | RM | 20 ₹1,60,000 | 20 ₹1,60,000 | 10 ₹80,000 Lowest | 10 ₹80,000 Lowest | 12 ₹96,000 | 15 ₹1,20,000 |
| 2.00 | Removal of gully trap covers, opening access door of CI/ AC/ PVC fittings and cleaning bend/Tee gully trap/ P- trap/ S-trap, gully trap upto first manhole and refixing the gully cover to its original position, complete all as specified and directed by Engineer-in-charge. | 700 | EACH | 30 ₹21,000 | 30 ₹21,000 | 50 ₹35,000 | 35 ₹24,500 | 20 ₹14,000 Lowest | 20 ₹14,000 Lowest |
| 3.00 | Material & Labour for cleaning MANHOLE, depth not exc. 2.00 mtr, by opening Cover and taking out accumulated Brick Bats, Garbage, Silts or any other Items, re-fixing the Cover after cleaning of Manhole, removing and carrying Brick Bats Garbage, Silts, etc. to a distance exc. 50 Metre but not exc. 100 Metre and buried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and directed by Engineer-in-charge. | 380 | Each Job | 50 ₹19,000 | 40 ₹15,200 Lowest | 380 ₹1,44,400 | 50 ₹19,000 | 50 ₹19,000 | 50 ₹19,000 |
| 4.00 | Cleaning & desludging of existing septic tank/sump/soak well by pumping water/sludge with suitable pump/manually from septic tank/sump/soak wells and removal of sludge outside MD land, complete all as specified and directed by Engineer-in-charge. | 100 | Cum | 90 ₹9,000 | 80 ₹8,000 Lowest | 1,200 ₹1,20,000 | 120 ₹12,000 | 80 ₹8,000 Lowest | 500 ₹50,000 |
| 5.00 | Supply & Fix in repair PVC (SWR) 75mm bore (dia) soil, waste and ventilating pipe, single socketed in any length with rubber ring joints with and including all necessary fittings such as bend, tee, junctions, traps etc fixed to walls, complete all as specified and directed. | 36 | RM | 250 ₹9,000 | 150 ₹5,400 | 200 ₹7,200 | 190 ₹6,840 | 130 ₹4,680 Lowest | 200 ₹7,200 |
| 6.00 | Supply & Fix in repair PVC (SWR) 110mm bore (dia) soil, waste and ventilating pipe, single socketed in any length with rubber ring joints fixed to walls with and including all necessary fittings such as bend, tee, junctions, traps etc, complete all as specified and directed. | 100 | RM | 350 ₹35,000 | 180 ₹18,000 Lowest | 225 ₹22,500 | 250 ₹25,000 | 180 ₹18,000 Lowest | 300 ₹30,000 |
| 7.00 | Supply & Fix in repair PVC (SWR) vent cowl 110mm dia, complete all as specified and directed. | 10 | Each | 50 ₹500 | 45 ₹450 Lowest | 100 ₹1,000 | 100 ₹1,000 | 80 ₹800 | 180 ₹1,800 |
| 8.00 | Supply & Fix in repair PVC (SWR) vent cowl 75 mm dia, complete all as specified and directed. | 9 | Each | 50 ₹450 | 40 ₹360 Lowest | 90 ₹810 | 100 ₹900 | 80 ₹720 | 150 ₹1,350 |
| 9.00 | Supply & Fix in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal with access door, complete all as specified and directed. | 10 | Each | 100 ₹1,000 | 70 ₹700 Lowest | 150 ₹1,500 | 120 ₹1,200 | 80 ₹800 | 300 ₹3,000 |
| 10.00 | Supply & Fix in repairs PVC (SWR) bend of any radius 110mm bore, complete all as specified and directed. | 12 | Each | 100 ₹1,200 | 60 ₹720 Lowest | 100 ₹1,200 | 120 ₹1,440 | 80 ₹960 | 150 ₹1,800 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
16 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Madan Lal Beniwal, IDSE, AEE Civil
AGE I DHANA PIN 470228, DIST SAGAR, MP
CLEANING AND IMPROVEMENT TO EXISTING SEWAGE SYSTEM OF UNITS AT DHANA MIL STATION.
2025_MES_725565_1
8300/DH/25/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) DHANA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Assistant Garrison Engineer (I) Dhana
₹16,000
Yes
17 Oct 2025
19 Aug 2025
18 Sept 2025
19 Aug 2025
16 Sept 2025
2 Sept 2025
Amount
Cleaning/desilting of man holes and sewage line of any diameter upto 200mm dia pipe by roding etc and subsequently bamboo split tied with rope through the pipe from manhole to manhole and cleaning the pipe clean for carry flow of sewage also getting out solid/liquid materials from manholes of any size and any depth including taking up and refixing of manhole cover in position and removal of sewage out of MD land, complete all as specified and directed by Engineer-in-charge. Note:- (length of sewage line will be measured including manhole)
Removal of gully trap covers, opening access door of CI/ AC/ PVC fittings and cleaning bend/Tee gully trap/ P- trap/ S-trap, gully trap upto first manhole and refixing the gully cover to its original position, complete all as specified and directed by Engineer-in-charge.
Material & Labour for cleaning MANHOLE, depth not exc. 2.00 mtr, by opening Cover and taking out accumulated Brick Bats, Garbage, Silts or any other Items, re-fixing the Cover after cleaning of Manhole, removing and carrying Brick Bats Garbage, Silts, etc. to a distance exc. 50 Metre but not exc. 100 Metre and buried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and directed by Engineer-in-charge.
Cleaning & desludging of existing septic tank/sump/soak well by pumping water/sludge with suitable pump/manually from septic tank/sump/soak wells and removal of sludge outside MD land, complete all as specified and directed by Engineer-in-charge.
Supply & Fix in repair PVC (SWR) 75mm bore (dia) soil, waste and ventilating pipe, single socketed in any length with rubber ring joints with and including all necessary fittings such as bend, tee, junctions, traps etc fixed to walls, complete all as specified and directed.
Supply & Fix in repair PVC (SWR) 110mm bore (dia) soil, waste and ventilating pipe, single socketed in any length with rubber ring joints fixed to walls with and including all necessary fittings such as bend, tee, junctions, traps etc, complete all as specified and directed.
Supply & Fix in repair PVC (SWR) vent cowl 110mm dia, complete all as specified and directed.
Supply & Fix in repair PVC (SWR) vent cowl 75 mm dia, complete all as specified and directed.
Supply & Fix in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal with access door, complete all as specified and directed.
Supply & Fix in repairs PVC (SWR) bend of any radius 110mm bore, complete all as specified and directed.
Supply & Fix in repairs PVC (SWR) bend of any radius 75 mm bore, complete all as specified and directed.
Supply & Fix in repair PVC (SWR) 75 mm dia in junction single, (Single T) equal or unequal with access door, complete all as specified and directed.
Material & Labour in repair for 150x100 mm dia salt glazed stoneware gully trap, square or round mounted, type "P" including setting and jointing to drain with cement mortar 1:1, complete all as specified and directed.
Material & Labour for Cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l (using 20mm graded crushed stone aggregate) area exc 150 sqcm, but not exc 400 sqcm, complete all as specified and directed.
Demolition of brick / stone masonry built in cement mortar, complete all as specified and directed.
Material & labour for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
Material & labour for 15mm rendering thick in CM (1:4) on fair faces of brick work/concrete surfaces finished even & smooth (without using extra cement), including preparing new plastered surface of wall and applying two coats of white wash, complete all as specified and directed.
Material and labour for rendering 15mm thick in CM (1:6) on fair faces of brick work/concrete surfaces, finished even & smooth (without using extra cement) including preparing new plastered surface of wall and applying two coats of white wash, complete all as specified and directed.
Supply & Fix providing precast in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces cement concrete in CM (1:4) Type B1 1:2:4 (20mm grade aggregate) completete all as specified and as directed.
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips completete all as specified and as directed.
S & F HDPE double wall corrugaed seage pipe of 100 mm internal bore, SN-8, ISI marked as per IS 16908 Part-II-2013 laid in trenches, jointed and tested as per manufacturer instruction including demolotition and breaking up drain pipes (salt glazed ware)/RCC Pipe etc set in cement ortar of 100 mm boare pipe, complete all as specified and directed.
Ditto as per item No 22.00, but 150mm internal dia pipe.
M&L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore, complete all as specified and directed.
NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 7090.00/- ]
Pandey Construction and Engrs (BID ID -3418508)
dipangashu barick and associates (BID ID -3418241)
m/s mahendra kumar khare contractor (BID ID -3419504)
siddhant construction (BID ID -3419766)
M/S JAINENDRA KUMAR JAIN (BID ID -3420121)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .