Loading…
Loading…
Tender Value
₹90.6 L
EMD Value
₹1.8 L
Closing Date
20 Jul 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Revenue
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnoverof [V/N or 'V' whichever is less; where V = Advertised value of the tenderin crores of Rupees N= Number of years prescribed for completion ofwork for which bids have been invited. The average annual contractualturnover shall be calculated as an average of "total contractualpayments" in the previous three financial years, as per the auditedbalance sheet. However, in case balance sheet of the previous year isyet to be prepared/ audited, the audited balance sheet of the fourthprevious year shall be considered for calculating average annualcontractual turnover. The tenderers shall submit requisite information asper Annexure-VIB, along with copies of Audited Balance Sheets dulycertified by the Chartered Accountant/ Certificate from CharteredAccountant duly supported by Audited Balance Sheet.
Experience in similar nature of work:- a) The tenderer must havesuccessfully completed any of the following during last 07(seven) years,ending last day of month previous to the one in which tender is invited:Three similar nature of works each costing not less than the amountequal to 30% of the advertised value of the tender, or Two similar natureof works each costing not less than the amount equal to 40% of theadvertised value of the tender, or One similar nature of work eachcosting not less than the amount equal to 60% of the advertised value ofthe tender. (b) (i) In case of tenders for composite works (e.g. worksinvolving more than one distinct component, such as Civil Engineeringworks, S&T works, Electrical works, OHE works etc. And in the case ofmajor bridges - substructure, superstructure etc.), the tenderer musthave successfully completed any of the following during last 07 (seven)years, ending the last day of the month previous to the one in whichtender is invited: Three similar nature of works each costing not lessthan the an amount equal to 30% of the advertised value of eachcomponent of the tender, or Two similar nature of works each costing notless than the amount equal to 40% of the advertised value of eachcomponent of tender, or One similar nature of work each costing not lessthan the amount equal to 60 % of the advertised value of eachcomponent of the tender. Note for b(i): Separate completed works ofminimum required values for each component shall also be consideredfor fulfillment of technical eligibility criteria. (b) (ii) In such cases, whatconstitutes a component in a composite work shall be clearly predefinedwith estimated tender cost of it, as part of the tender documents withoutany ambiguity. (b) (iii) To evaluate the technical eligibility of thetenderer, only components of work as stipulated in tender documents forevaluation of technical eligibility shall be considered. The scope of workcovered in other remaining components shall be either executed by thetenderer himself if he has work experience as mentioned in clause 7 (a)(ii) of Part-II of GCC or through subcontractor fulfilling the requirementsas per clause 7 of Part-II of GCC or jointly i.e., partly himself andremaining through subcontractor, with prior approval of Chief Engineerin writing. However, if required in tender documents by way of SpecialConditions, a formal agreement duly notarised, legally enforceable in thecourt of law, shall be executed by the main contractor with thesubcontractor for the component(s) of work proposed to be executed bythe subcontractor(s), and shall be submitted along with the offer forconsidering subletting of that scope of work towards fulfillment oftechnical eligibility. In case after the award of the contract or during theexecution of work it becomes necessary for the contractor to changesubcontractor, the same shall be done with subcontractor(s) fulfilling therequirements as per clause 7 of Part-II of GCC, with prior approval of theChief Engineer in writing.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work"
Tenderer must have to submit valid Electrical Contractor licenseas per Indian Electricity Rules for the respective category ofworks issued by Government Electrical License Board on orbefore the closing date of tender. Copy of the electricalcontractor license should be submitted along with the tenderoffer, otherwise, the tender will be summarily rejected.
51 conditions · 5 needing a document upload
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
Rectification of cable and switchboard connections for Mechanized Coach Cleaning Machines and Bio-Toilet Evacuation Machines at Pit No.-1, Pit No.-2, Pit No.-3 and GHY Pit, along with wiring of glow signboards at GHY, KYQ, DMV, SCL and BPB stations for improvement of passenger amenities, including all associated electrical accessories and allied works in connection with shifting of High Mast Tower at GHY and other electrical works at UBZ.
EL-LM-26-27-12~NFR
EL-LM-26-27-12
Open
Works - General
90 Days
Hojai, Assam
₹0
₹1.8 L
20 Jul 2026
26 Jun 2026
6 Jul 2026
67 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 61,21,463.3 | ||
| — | 2.00 | — | — | ||
| Design, fabrication, supply, installation, testing and commissioning of LT pedestal mounted control panel outdoor type of double door construction, FORM-3b as per IEC 60439-1 standards with IP 54/55 and 415 V 3phase &4 wire system, rear access type. The panel colour shall be RAL 7035 structured finish. cable entry incoming=bottom,outgoing=bottom.Horizontal 250 Amp, 8 way copper busbar will be running at the top throughout the panel Enclosure shall be of CRCA steel sheet type. load bearing parts shall have 2mm thickness & non-loading parts shall have 1.6mm thickness. Gland plate shall be 3mm of GI type. the busbar system shall have heat shrinkable colored PVC sleeve. main busbar (power bus) is TPN electrolytic copper busbar size (50x6)mm. Doors and covers shall be gasketed by Neoprene gaskets. Control wires shall be 1.1KV grade Copper Flexible conductors. Panel should have short circuit strength at 100KA for 1 seconds as per IS:8623 part-I and temperature rise test at 6300 A as per IS:8623 part-1.The panel shall also consist of multifunction meter, CT, LED indicating lamps, auxiliary contractors, selector switches, cam switches etc as per manufacturer specification /recommendation & Cable alley also. the panel shall be provided with 3nos bus bar for phases made of electrolytic grade of copper bar of each (50x6) mm. the incoming switches shall beconnected with bus bar by crimping sockets on bus bar of panel side. the bar shall be connected by on either side by porcelain insulator and sufficient clearance shall be maintained inside the bus bar doe easy maintenance. Drawing would be submitted by the contractor and approved by competent authority. the panel has to built & inspected in OEM factory. inspection has to be carried out in presence of Rly's authorized representative. the control panel should be designed and manufactured by the CPRI and ISI.ISO approved manufacturer. The panel shall be fabricated from 2 mm thick consisting of . (i) MCCB 250 Amps 4pole 36 KA = 2 nos.(ii) MCCB 63 Amps 4pole 36 KA = 4 nos. Ics=100%Icu with microprocessor release controlled confirming to IS/IEC 60947-2, Adjustable overload setting from 0.4 to 1.0 x In, Adjustable short-circuit setting from 1.5 to 8 x Ir,Inbuilt instantaneous Protection, Switchable thermal memory, Variable trip class, Front LED Indication, Manual & Rotary versions available. | — | — | — | 8,04,360 | |
| — | 1000.00 | — | — | ||
| Laying, fitting, fixing and commissioning of LT/HT XLPE insulated, armoured power cables with aluminium conductors of different sizes, suitable for the required voltage grade, including proper dressing, clamping and securing of cables partly along poles/structures and partly in ground cable trenches as per site requirement. The work shall include excavation of trenches, sand bedding, protective covering with bricks/tiles, refilling and compaction, ensuring proper route marking and safety precautions as per relevant IS standards (IS:1255/IS:7098 or latest). It also includes loading, unloading, safe transportation and carrying of cables to site by contractor's own arrangement as directed by the Engineer-in-Charge. Termination and jointing shall be carried out using approved kits with proper crimping, sealing and ferruling to ensure reliable performance. Necessary testing such as insulation resistance, continuity and phase identification shall be done before commissioning, and the entire work shall be executed as per relevant IS specifications and instructions of the Engineer-in-Charge at site. | — | — | — | 43,710 | |
| — | 1000.00 | — | — | ||
| Supply and laying of 90 mm dia DWC HDPE pipe (Nominal OD-90 mm and ID-76 mm) ISI marked, conforming to IS 14930 Part-II, including supply of all required accessories such as sockets, bends, couplers and other fittings. The work shall include transportation, handling, cutting, fitting, jointing, alignment and laying of the pipe in the existing trench, including all necessary minor works required for proper installation. The complete work shall be carried out as per site conditions, specifications and instructions of the Engineer-in-Charge, including all materials, labour, tools & plants and incidental charges for satisfactory completion of the work. | — | — | — | 1,83,000 | |
| — | 125.00 | — | — | ||
| Supply, installation, testing and commissioning of waterproof IP-65 rated cable junction box of size approximately 300 x 450 x 170 mm, suitable for termination/jointing of 70 sq.mm cables, similar to Hensel Cat. No. K 7004 with flange without knockouts similar to Hensel Cat. No. MI FP 20 or equivalent approved make. The junction box shall be complete with suitable cable entry arrangement, glands, flange, accessories, mounting hardware and all necessary fittings required for proper installation. The work shall include supply, transportation, fixing, cable entry, termination, connection, sealing, testing and commissioning complete in all respects. The entire work shall be executed as per site conditions and instructions of the Site Engineer/Engineer-in- Charge, including all labour, tools & plants and incidental works required for satisfactory completion. | — | — | — | 32,98,125 | |
| — | 188.00 | — | — | ||
| Supply, erection, fitting and fixing of G.I. pipe of 1.5 metre length for mounting/holding industrial socket board, complete with necessary clamps, supports, base arrangement, fasteners and accessories as required at site. The total quantity of G.I. pipe shall be approximately 188 metres (1.5 metre length x 125 Nos.) or as per actual site requirement. The work shall include supply of G.I. pipe, transportation, cutting, threading, drilling, fixing, alignment, installation of supports and all necessary accessories required for proper erection and stability of the industrial socket boards. The complete work shall be executed as per site conditions and instructions of the Site Engineer/Engineer-in-Charge, including all labour, tools & plants and incidental works for satisfactory completion. | — | — | — | 1,46,858.08 | |
| — | 125.00 | — | — | ||
| Supply of materials and muffing of pole/pipe by construction of CC foundation block using Cement Concrete mix ratio 1:2:4 (cement:sand:stone chips of 19 mm size and down) for proper support and protection of pole/pipe. The CC muffing shall be constructed with size approximately 30 cm x 30 cm, extending from the bottom of the pole up to 30 cm above Ground Level (GL). The work shall include supply of cement, sand, stone chips and all other required materials, excavation, preparation of foundation, concreting, leveling, finishing, curing and making good the surrounding area complete in all respects. The work shall be executed as per site conditions and instructions of the Engineer-in-Charge/Site Engineer, including all labour, tools & plants and incidental works required for satisfactory completion. | — | — | — | 54,245 | |
| — | 125.00 | — | — | ||
| Supply, installation, testing and commissioning of IP-67 rated industrial wall socket with DIN rail arrangement, 32 Amp, 2P+E configuration, complete with 32 Amp SP MCB of C-Curve characteristics, similar to Hensel Cat. No. 3232 TS-32 or equivalent approved make. The industrial socket shall be complete with suitable enclosure, DIN rail mounting arrangement, protection accessories, terminals, internal wiring and all necessary fittings required for safe and reliable operation. The work shall include supply, transportation, fixing, cable entry, termination, connection, testing and commissioning complete in all respects. The entire work shall be executed as per site conditions and instructions of the Site Engineer/Engineer-in-Charge, including all labour, tools & plants, consumables and incidental works required for satisfactory completion. | — | — | — | 8,40,000 | |
| — | 125.00 | — | — | ||
| Supply, installation, testing and commissioning of IP-67 rated industrial CEE plug, 32 Amp, 3 Pole, 6 Hour (3P 6H) configuration, similar to Hensel Cat. No. 0232-6 or equivalent approved make, complete with all necessary accessories and fittings. The work shall include supply of industrial plug, transportation, installation, proper fixing, cable entry, termination, connection, testing and commissioning with all required hardware and accessories for safe and reliable operation. The complete work shall be executed as per site conditions and instructions of the Site Engineer/Engineer-in-Charge, including all labour, tools & plants, consumables and incidental works required for satisfactory completion. | — | — | — | 1,67,500 | |
| — | 300.00 | — | — | ||
| Supply and laying of 10 sq.mm PVC insulated, two core, flat sheathed, stranded aluminium conductor cable of 1100 Volt grade, conforming to IS:694 (latest amendment), with black outer sheath for wiring of industrial wall socket points. The work shall include supply of cable, transportation, laying, dressing, routing, fixing with suitable clamps/supports, cable entry, termination, connection with suitable lugs/glands, testing and commissioning complete in all respects. All necessary accessories, consumables, labour, tools & plants and incidental works required for proper installation and satisfactory operation shall be included as per site conditions and instructions of the Engineer-in-Charge/Site Engineer. | — | — | — | 18,447 | |
| — | 300.00 | — | — | ||
| Supply, laying and commissioning of 19 mm size uPVC medium duty rigid conduit pipe complete with all necessary accessories such as uPVC sockets, elbows, tees, bends, saddles, clamps and other fittings required for proper installation. The work shall include supply of conduit pipe and accessories, transportation, cutting, jointing, laying/fixing, alignment, dressing, supporting arrangement and commissioning complete in all respects. The work shall be executed as per site conditions and instructions of the Site Engineer/Engineer-in-Charge, including all labour, tools & plants, consumables and incidental works required for satisfactory completion. | — | — | — | 5,760 | |
| — | 8.00 | — | — | ||
| Supply and erection of earthing made of B class GI pipe of 4000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip(50x6)mm should be welded with the earth pipe. The pipe is provided with tapered casing at the lowerend in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil.Where soil restivity is high,earth restivity enhancing material may be used,Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. This will supersedes the earlier drawing no. PCEE/ELG/DRG/2024/1 dated 30.09.24 & CEE/STD/1 As per Drg.No.: PCEE/ELG/DRG/2024/1/Rev-1 dated 28.07.2025 & as per Technical circular no.EL/PS/2025/1 (Pipe Earthing arrangements) | — | — | — | 12,564.64 | |
| — | 6.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 2TR with 5 Star BEE Rating Air Cooled Hi Wall split type Inverter Type - Cooling only Room Air conditioners (RAC) complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).All consumables (GI Stand for outdoor units where required) for fixing arrangement to be provided and executed by the firm as per direction of engineer in charge at site. The RAC shall comprise Indoor Unit (IDU) with evaporator, blower, filters, controls and casing, and Outdoor Unit (ODU) with compressor, condenser, fan, refrigerant and associated electrical and protection components. " The outdoor unit of the Room Air Conditioner (RAC) shall be installed on the non-platform side, with an appropriate outlet water drainage pipe arrangement."(Year of make 2026) | — | — | — | 3,97,800 | |
| — | 60.00 | — | — | ||
| Supply, erection, testing and commissioning of refrigerant copper pipe of 6.4 mm (1/4") diameter for interconnection/integration of outdoor and indoor units of air conditioning system. The work shall include supply and installation of copper piping complete with necessary fittings, joints, brazing, supports, clamps and accessories as required for proper functioning of the system. The copper pipe shall be provided with Nitrile Rubber insulation of Class 'O' (tubular form), having 19 mm thickness for suction line and 13 mm thickness for liquid line. Copper pipe shall be of approved make such as Rajco/Mandev/Totaline/Maxflow and insulation shall be of approved make such as K-Flex/Aeroflex/Armacell or equivalent. The rate shall include transportation, erection, proper routing, insulation, sealing of joints, testing, commissioning, all materials, labour, tools & plants and incidental works required for complete installation as per site conditions and instructions of Engineer-in-Charge. | — | — | — | 52,717.8 | |
| — | 60.00 | — | — | ||
| Supply, erection, testing and commissioning of refrigerant copper pipe of 12.7 mm (1/2") diameter for interconnection/integration of outdoor and indoor units of air conditioning system. The work shall include supply and installation of copper piping complete with necessary fittings, joints, brazing, supports, clamps and all accessories required for proper installation and operation of the system. The copper pipe shall be provided with Nitrile Rubber insulation of Class 'O' (tubular form), having 19 mm thickness for suction line and 13 mm thickness for liquid line. Copper pipe shall be of approved make such as Rajco/Mandev/Totaline/Maxflow and insulation shall be of approved make such as K-Flex/Aeroflex/Armacell or equivalent. The rate shall include transportation, erection, proper routing, insulation, sealing of joints, testing, commissioning, all required materials, labour, tools & plants and incidental works complete in all respects as per site conditions and instructions of the Engineer-in-Charge. | — | — | — | 68,739.6 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of wall mounted 5 kVA automatic voltage stabilizer suitable for single phase, 230 V AC, 50 Hz supply complete with all accessories, mounting arrangement and internal connections as per direction of Engineer-in-Charge at site. The stabilizer shall have working range of 140 V to 300 V, input operating range of 165 V to 285 V and stabilized output range of 200 V to 240 V with output regulation within ±1% to ±2%. The stabilizer shall be servo controlled/automatic electronic type with high and low voltage cut-off protection, overload protection, short circuit protection, thermal overload protection and spike/surge suppression facility. The unit shall be provided with copper wound buck-boost transformer, digital input/output voltage display, automatic reset facility, air-cooled design and high efficiency operation. The enclosure shall be CRCA sheet steel with powder coated finish suitable for wall mounting. The stabilizer shall conform to relevant provisions of IS 9815 and applicable BIS standards. Complete with all mounting hardware, interconnections, testing and commissioning for satisfactory operation at site. Make: Miracle or similar model of Godrej/Vertex / Hitek / V-Guard. | — | — | — | 22,776 | |
| — | 6.00 | — | — | ||
| Supply & wiring of Room Air Conditioner(RAC) point through suitable size (19mm) of PVC Concealed rigid Conduit pipe by 2x 4 sq.mm PVC insulated unsheathed and multi-stranded FRLS-HR copper cable on wall complete with 1 No. 25 A motor starter switch, 1 No. 32A SP mini MCB, C-series, 3kA, 6-16 A 3 pin shuttered socket with 3M concealed unbreakable GI modular box, 3 M cover plate etc. as required at site including 1sq. mm unsheathed copper cable as earth continuity wire. | — | — | — | 4,860.18 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-12final.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .