Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC | L1 | Accepted-AOC L1bidder | |
| 2 | L2₹49.3 L+₹78,531 (1.62%)Rejected-Finance | L2 | Rejected-Finance Not L1 bidder | |
| 3 | L3₹52.5 L+₹4.1 L (8.37%)Rejected-Finance | L3 | Rejected-Finance Not L1 bidder | |
| 4 | L4₹54.9 L+₹6.4 L (13.2%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L4 | Rejected-Finance Not L1 bidder |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
22 Mar 2022, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
SPECIAL REPAIR REPLACEMENT OF OVERHEAD ELECTRIC LINE TO UNDER GROUND CABLE, STREET LIGHT, PANEL BOARD, OTHER CONNECTED ITEMS AT VOC, VNC, DOMLUR UNDER GE CENTRAL BANGALORE
2022_MES_511052_1
8148E
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹96,000
Yes
28 Mar 2022
28 Feb 2022
24 Mar 2022
28 Feb 2022
22 Mar 2022
8 Mar 2022
28 Feb 2022 - 7 Mar 2022
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth for laying of UG cable, GI/CI pipe lines etc getting out including forming bottom surface to required level and gradient in hard/dense soil.
All as per item No 1 above but exc 1.5 metre and not exc 3.0 metre deep.
Returning and filling in excavated soil including spreading leveling, watering, well ramming in layers not exc 25 cm thick complete.
Removing of excavated materials not exceeding 50 Mtrs and depositing where directed by Engr- in-Charge at a level not exceeding 1.5 Mtrs above the starting point.
Provision of trenchless bore using mechanical nuematic drilling equipment for passing electric cables through pipe upto 200mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusive of necessary earth work, transportation charges of Drilling machine and passing pipe through bore complete. 2. Any damage to MES assets caused during trenchless bore shall be recitfied by the contractor at his own cost.
M & L for Sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply and laying well burnt bricks, locally available best quality bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
Supplying and laying un-reinforced precast conncrete cable cover type 2, size 300X180X40mm thick in trenches for protection of HT cable all as directed.
S&F cast iron cable route indicator with embrossing mark as HT cable, circular type, 75mm dia , 6 mm thick duly fixed with suitable MS angle iron member of size 50X50X4mm and 60 cm long to be embeded in PCC (1:3:6) type C1 block of size 300x300x500mm deep in ground complete all as specified and directed. NOTE :- Route indicator shall be provided at not exc 50 metre interval and at every turning point.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and stacking aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work complete all as directed by the Engr-in-Charge
Dismantling of insulators of any type, any size from LT poles of any size and type and serviceable insulator keep in safe custody for re-use and unserviceable insulators removing from the site (s), complete all as specified and directed.
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and directed.
Dismantling/uprooting of LT unserviceable pre-stressed concrete/steel poles of any size and shape & fixed in any position and Supply & fix new 9 metres long steel tubular swaged pole complete with cast iron base plate , finial taper plug ,bolts, nuts & screws as specified type 410 SP -31 fixed in position including two coats of aluminium paint over a coat of primer except the planting depth which shall be painted with black bituminous paint including writing pole number using suitable paint complete all as directed. NOTE :- Excavation and PCC will be measured and paid seperately under relevant items.
Dismantling/uprooting of LT unserviceable pre-stressed concrete/steel poles of any size and shape & fixed in any position and Supply & fix new 11 metres long steel tubular swaged pole complete with cast iron base plate , finial taper plug ,bolts, nuts & screws as specified type 410 SP -55 fixed in position including two coats of aluminium paint over a coat of primer except the planting depth which shall be painted with black bituminous paint including writing pole number using suitable paint complete all as directed. NOTE :- Excavation and PCC will be measured and paid seperately under relevant items.
M & L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M & L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 150 mm height 150mm dia suitable for 11000 volts grade complete all as specified and directed.
S & F aluminium conductor steel reinforced (ACSR) conductor including binding, straining in LT over head line including all jumper connection and binding on insulator with new wire/aluminium tape complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded hard granite stone aggregate) in foundations for pole or in filling as directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B1 (using 20 mm graded hard granite stone aggregate) as in coping to Electric Pole including necessary form work and finishing the external surfaces of concrete with 10 mm thick plastering in CM (1:4) finished even and smooth complete all as directed. (Note Quoted rate is deemed to be inclusive of form work and plastering complete.)
S&F street light thermoplastic cable Junction box made of SMC/FRP of size 200x255x112mm, IP-66, weather proof for outdoor use with TPN terminal and with MCB SP, 6-32A, 10 KA, 'C' Curve, 01 No and connector terminal 4 pole indicating RYB Phase Colour and Neutral colour complete fixed to street light pole with suitable size of mild steel clamps, nuts & bolts complete all as specified and directed. (Make - Hensel, CAT No : KF 2525 or equivalent model of make as per list of manufacturer attached).
S&F energy saving environmental friendly long life, with highly effective and efficient luminaire robust design LED street light 1x 80 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP-66 protection grade and wired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long suitable for 40/50 mm bore pipe bracket and testing on installation complete all as specified and directed. Make: Havell's Cat No. ENDURACITYLINERNEOMPSL80WLED757PASYBOTG or equivelant of make Bajaj/CG//Wipro.
M&L for taking down old unserviceable bracket and provision of bracket on steel poles for fixing of street light fittings, bended to 45 degree angle, made out of 32/40mm dia GI pipe dedium grade, 1.2 mtr long fixed with and including 2 Nos MS clamps made from mild steel flat of size 40x3mm, bolt,nuts and washers including two coats of aluminium paint over a coat of zinc chromate primer complete all as specified.
50mm bore GI pipe "light grade" for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings, two coats of aluminium paint over a coat of zinc chromate primer complete all as specified.
80mm bore GI pipe "light grade" for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings, two coats of aluminium paint over a coat of zinc chromate primer complete all as specified. Note for item No 22 & 23 : Excavation/ Earth work, MS clamp, nuts, bolts, washers shall be measured and paid under respective items of this BOQ.
S & F mild steel clamp made out of 40X3mm flat iron, suitable nuts, bolts, washer etc for fixing GI protection pipe/flood light to electric pole including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, 4 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 50 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 120 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 150 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 240 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene XLPE insulated, armoured cable for working voltage of 11000 Volts earthed, under ground HT cable, PVC insulated, armoured, 3 core, nominal cross sectional area of main conductor 95 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
Dismantling air break GOD switch, vertical/horinzontal mounted including insulators and operating mechanism for repair/replacement of broken/damaged/worn out components and insulators complete all as directed.
Supply, installation, testing and commissioning HT 11 KV switch Air Break Gang Operated triple pole, horizontal type double break mechanically operated mounted on insulators and steel frame with operating mechanism system, work from ground level for current rating upto 400 Amps all as directed. (Make :– High tension switch gear ltd / Jaipuria /Mysore Electrical Industries/Pactil).
Taking down unserviceable HT lightning arrestor and supply & fixing new HT suitable for 11000 Volts grade metal oxide type (expulsion type) lightning arrestor with all acessories clamps for foxing, connection, discharge capacity 65 Kilo Amps complete all as directed. (Make :– High tension switch gear ltd / Jaipuria /Mysore Electrical Industries/Pactil).
Supply, fixing and testing of Horn Gap fuse two post insulator per phase complete with GI channel mounting for 11000 volt grade, 400 amps complete including taking down old unserviceable one complete all as directed by Engr-in-charge. (Make :– High tension switch gear ltd / Jaipuria /Mysore Electrical Industries/Pactil).
M & L for Preparation of old painted rusted steel/iron surfaces of 9 metre steel tubular electric pole including cross arms other acessories/fittings by scraping properly and applying two coats coat of aluminium paint over a coat of primer including rewriting pole number using suitable tint paint making circular shape background and painting using synthetic enamel paint upto 80 cm height from the top of coping with multicolour strips as per colour code complete all as specified and directed.
M & L for preparation of old surfaces of 9 metre long RCC/Pre- stressed concrete electric pole and applying two coats of weather coat acrylic exterior paint (ie Apex Ultima of ASIAN Paints) over a coat of primer from 80 cm above coping upto top of pole and applying two coats of synthetic enamel paint upto 80 cm height from top of coping with multicolour strips as per colour code writing pole number including painting to steel members like cross arms, brackets, cable protection pipe, clamps etc using aluminium paint complete all as directed.
Material and labour for PVC insulated weather proof aluminium conductor cable single core flexible multistranded aluminium conductor cable, 2X2.5 sqmm for connection of security / street light fitting from junction box including making proper connection using suitable size thimbles/lugs complete all as directed. Note : - 2 run cable shall be measured and paind as one unit.
Material and labour for preparation old steel section (ie post and other steel members) and chain link fencing and applying two coats of aluminium paint complete all as directed.
M&L for removing existing oil/ paint by scrapping and applying two coats of approved colour synthetic enamel paint (1st grade quality) over a coat of primer using spray painting machine in Transformer of capacity 160 KVA to 315 KVA, 11 KV/0.433 KV. all as directed by Engr-in-Charge.
M&L for preparation of old surfaces of existing electrical LT panel, cross arms , clamps etc of any description and apply one coat of approved colour synthetic enamel paint complete all as specified and as directed.
Supply and fixing heat shrinkable type cable end jointing kit for HT 11000 volts grade (Earthed) UG cables for outdoor use complete with jointing materials and acessories suitable for 3 core XLPE aluminium conductor cable of size 95 sqmm.
Supply and fixing heat shrinkable type cable end jointing kit for HT 11000 volts grade (Earthed) UG cables for indoor use complete with jointing materials and acessories suitable for 3 core XLPE aluminium conductor cable of size 95 sqmm.
Supply and Fixing exhaust fan, 300mm sweep metal body, AC single phase 230/240 Volt including bird free louver shutter cut to fit with hole for exhaust fan including providing holes grouting bolts and 3 core flexible copper conductor cable of size 24/0.20 sqmm connecting up from ceiling rose to exhaust fan terminal complete all as directed. Make : - Usha/almonard/Crompton/Khaitan/Bajaj.
Supply and Fixing exhaust fan, 250mm sweep engineering plastic body, AC single phase 230/240 Volt including bird free louver shutter cut to fit with hole for exhaust fan including providing holes grouting bolts and 3 core flexible copper conductor cable of size 24/0.20 sqmm connecting up from ceiling rose to exhaust fan terminal complete all as directed. Make : - Usha/almonard/Crompton/Khaitan/Bajaj.
Supply & Fixing 5 star rated energy saving ceiling fan 1200mm sweep (white) with all accessories and hanging the ceiling fan from existing fan hook with 3 core flexible copper wire 24/0.20 sqmm from ceiling rose, etc all as directed. Make : Bajaj/Crompton/Polar/Khaitan/Orient Electric
M & L Earthing complete of machinery/equipment installed at power house/substation with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 3.0 m below normal ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth strip 32 x 6mm thick by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 300x300x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in any type of soil all as shown in Electrical Plate No 3 of MES Schedule Part I, earth lead connected to main switch board or main control board all as directed and testing on completion including taking down old unserviceable earthing. (Cost of earthing deemed to to be included upto 7.5 metre long GI earth strip and GI protection pipe including fittings. Earth pit shall be at min 500mm away from external face of building.)
M & L Earthing complete of machinery/equipment installed at power house/substation with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 3.0 m below normal ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth strip 25X4mm thick by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 300x300x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in any type of soil all as shown in Electrical Plate No 3 of MES Schedule Part I, earth lead connected to main switch board or main control board all as directed and testing on completion. (Cost of earthing deemed to to be included upto 7.5 metre long GI earth strip and GI protection pipe including fittings. Earth pit shall be at min 500mm away from external face of building.)
M&L for Vaccum dehydration with hot filteration oil of old Transformer oil at various location, after filteration by achieving required Di Electric strength (ie should be min 45KV at 2.5mm gape) complete all as directed. Note : 1) Oil to be filtered after getting recommendation of Engr-in-Charge . 2) Test reports complete in all respects to be submitted by the contractor.
Supply of transformer Oil and toping up /oil change of Transformers/ CTs/PTs any capacity all as conforming to IS-335 at various transformers and different location . NOTE: The dielectric strenght of the Transfomer oil must be 45 KV r.m.s (min) . Make : Power oil /HP/BP.
M&L for replacement of breather assembly transparent body with top and bottom portion pressed with mettalic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia as per site requirement and capacity for Transformers 11KV of capacity upto 315 KVA including taking out old one complete all as directed.
Design, fabrication, installation and testing of LT out door type factory made(CPRI Approved), junction box of size 900mm(H)X700mm(B)X400mm(W) (over all dimension) made out of 3.0mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5 mm frame, 04 Nos aluminium bus bar of of capacity 250 Amps with drilled hole for incoming/outgoing cable connection with necessary aluminium lungs, GI nuts bolts and washer including 08 Nos bridge insulator DMC , heavy duty, suitable for 3 Phase 4 wire system, one danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull & bones in signal red colour and fixed in front door size and PCC (1:3:6) type C-1 foundation 0.30m above normal ground level & 0.30m below ground level with necessary exacavation and earth work and painting to internal and external steel surface with powder coated (Siemence grey) RL-35 after neccesary preparation of surfaces including Indicating lamp LED type 240V 50 Hz AC -one set of 3 Make: L&T/Legrand/ ABB/Siemens/Havells compete all as directed.
Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door , cubical type panel board of over all min dimension 0.80 m (L) X 1.00m (H) X 0.50m (W) fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase 4 wire system by means of Alluminum bus bar of 250 Amps Capacity (Main bus bar ) and 350 Amps Loop Bus bar with coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs height above GL and 0.30mtrs below GL including necessary earth work complete all as specified and as directed. (a) INCOMING: MCCB 4 pole, 100Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No Make: L&T/Legrand/ ABB/Siemens/Havells (b) OUTGOING: MCB TPN 63Amp, 10KA,C curve - 05 Nos . Make: Legrand cat No 408683 or equivalent model of L&T/ ABB/Siemens/Havells. (c) Indicating lamp LED type 240V 50 Hz AC -one set of 3 .Make: L&T/Legrand/ ABB/Siemens/Havells
Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door, cubical type panel board of over all min dimension 1.2 m (L) X 1.00m (H) X 0.50m (W) fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase 4 wire system by means of Alluminium bus bar of 250 Amps Capacity (Main bus bar ) and 350 Amps Loop Bus bar with coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs height above GL and 0.30mtrs below GL including necessary earth work complete all as specified and as directed. (a) INCOMING: MCCB 4 pole 250Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No Make: L&T/Legrand/ ABB/Siemens/Havells (b) OUTGOING: MCCB 4 pole 160Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -03 Nos Make: L&T/Legrand/ ABB/Siemens/Havells (c) O/G MCB TPN 63Amp, 10KA,C curve - 02 Nos . Make: Legrand cat No 408683 or equivalent model of L&T/ ABB/Siemens/Havells. (d) Indicating lamp LED type 240V 50 Hz AC -one set of 3 .Make: L&T/Legrand/ ABB/Siemens/Havells
Supply, installation, testing and commissioning of canopy headed double door outdoor type totally enclosed street light controlling panel of min size 80X60X40 cm , suitable for 3 phase, 4 wire 440 Volt , made out of 3.0 mm thick CRCA sheet , cubical type, duly finished with powder coated paint RAL 7035 , having front hinged door with neoprene rubber gasket including danger notice plate, earthing termination points, bottom detachable gland plate with holes for incomming and out going cables fixing arrangement with 40X40X5mm thick MS angle iron leg grouting in PCC foundation in 1:3:6, type C1 of 0.5 mtrs height above GL and 0.30mtrs below GL including necessary earth work complete with following accessories i) MCCB 4 Pole 63 Amps 25 KA breaking capacity-01 No. Make : L&T/Legrand/ ABB/Siemens/Havells ii) Analog type Time switch 110-240Volt suitable for 24 hours operation of street light. Make : L&T/Legrand/ ABB/Siemens/Havells iii) Contactor three pole 40 Amps 415 volt Coil operating Voltage 230 volt . Make : L&T/Legrand/ ABB/Siemens/Havells. iv) Auto manual switch 10 Amp (make: Kaycee/L&T/legrand/AT). v) MCB TPN 63Amp, 10KA, C curve - 2 Nos . Make: L&T/Legrand/ ABB/Siemens/Havells complete all including internal connection done by using suitable size of copper wire complete all as specified and directed.
S&F single side painted flex glow sign board of 1.80X1.00X0.25 Mtrs size fabricated with 20mm mild steel square hollow pipe frame work, front side and back side covered with Aluminium sheet side openable type including writing latter diagram, photoghraphy and making design covering the front surface as directed by Engr-in -Charge including providing 2X20 Watt LED tube light inside sign board for glow with necessary electrical connection. Glow sign board shall be standed at 1.2 mtrs above ground level by means of 40X40X5mm thick MS angle iron post duly embeded in PCC 1:3:6 type C1 foundation block of size 300X300X450mm depth, painting to iron members complete all as directed.
M & L for construction of platform including 60 cm wide plinth alround for transformer with following specification & size (a) Excavation and earth work in soft/loose soil upto 50cm below GL, providing PCC 1:4:8 type D2 150mm thick mass or lean concrete foundation. (b) Size of platform 1.50m x 1.50m x 1.00m height above natural GL using PCC 1:3:6 type C1 precast solid concrete block masonary in 1:4 (c) Moorum filling ramming incl 50mm thick stone aggregate filling and 150mm thick 1:2:4 type B1 PCC floor finished even and smooth using extra cement. (d) 15mm thick rendering of wall finished even and smooth without using extra cement. (e) Plinth protection 75 mm thick and 600 mm wide alround the platform/foundation using PCC 1:3:6, type C1 over rammed earth.
Shifting of transformer from one place to another place by using of Hydra /Crane or other transport etc to a distance not more than 5 Km and placing in/over platform/foundation of Transformer complete all as specified and as directed.
jjengineers
RAMSON TRADERS
Shiva Shakthi Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .