| 1 | L1₹41.9 LAccepted-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | ₹41.9 L | L1 | Accepted-AOC Approved |
| 2 | L2₹49.8 LRejected-Finance 00 BHADAR TIKARMAFI BAZAR SULTANPUR UTTAR PRADESH 227413 | AMETHI | UTTAR PRADESH | 227413 | ₹49.8 L | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹63.1 LRejected-Finance 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | ₹63.1 L | L3 | Rejected-Finance 3rd Lowest |
| Sl No | Description | Qty | Unit | UTTRAKHAND BUILDERS L3 | Arun Construction Co. L1 | M/s Dev Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.00 | Surface excavation in soft soil n.exc. 30 cm deep and averaging 15 cm deep and getting out in soil complete all as specified and directed. | 2,214 | Sqm | 80 ₹1.8 L | 15 ₹33,210 | 35 ₹77,490 |
| 2.00 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm soft/loose soil complete all as specified and directed. | 42 | Each | 105 ₹4,410 | 100 ₹4,200 | 300 ₹12,600 |
| 3.00 | M&L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundations, fillings, Mass concrete, footings etc complete all as specified and directed. | 6 | Cum | 5,800 ₹34,800 | 4,500 ₹27,000 | 4,000 ₹24,000 |
| 4.00 | S&F Steel work in tubular trusses (minimum Post dia 150mm & height above GL 3-4m ) including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. | 1,800 | Kg | 142 ₹2.6 L | 100 ₹1.8 L | 133 ₹2.4 L |
| 5.00 | S&F Roof trusses Fe 410 -W (Gde E- 250) quality A (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. | 8,090 | Kg | 128 ₹10.4 L | 95 ₹7.7 L | 133 ₹10.8 L |
| 6.00 | M&L for preparation of steel and iron surface exceedding 10 cm width or girth and applying two coas of synthetic enamel paint over one coat of red oxide zink chrome primer complete all as specified and directed. | 404 | Sqm | 110 ₹44,440 | 50 ₹20,200 | 60 ₹24,240 |
| 7.00 | Supplied and fixed fibre cement coloured textured designer ceiling board 4mm thick of size 595x595 mm conforming to IS : 14862 & IS : 2380 Part-XIV fixed to timber / GI / Aluminium frame work with screws/clips complete all as per manufactures instructions and as directed. | 250 | Sqm | 800 ₹2 L | 280 ₹70,000 | 450 ₹1.1 L |
| 8.00 | S&F GI snap grid frame work for false ceiling of size of grid 605x605mm all as specified and Hangers 2mm dia GI (upto 1200mm length) adjusting level fixed to steel frame work complete all as specified and directed. | 350 | Sqm | 550 ₹1.9 L | 300 ₹1.1 L | 450 ₹1.6 L |
| 9.00 | M&L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundations, fillings, Mass concrete, footings etc complete all as specified and directed. | 32 | Cum | 5,450 ₹1.7 L | 4,800 ₹1.5 L | 4,250 ₹1.4 L |
| 10.00 | M&L for broken stone or boulders hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. | 163 | Cum | 3,250 ₹5.3 L | 1,800 ₹2.9 L | 1,850 ₹3.0 L |
Updated dates
Tender Value
₹54.1 L
EMD Value
₹1.1 L
Closing Date
12 Nov 2025, 6:00 pmClosed
HQ CWE MEERUT
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
PROVN OF 1000 SQM INTERNAL PATHWAY OF INTERLOCKING TILES AT OLD KENNEL COMPLEX AND BASIC OBEDIENCE INCLUDING CONNECTION WITH ADM OFFICE COMPLEX, PROVN OF COVERED GROOMING /TRG SHED FOR TR DOGS (SIZE 18 MTR X 7 MTR), 08 X CEILING FANS, 04 X LIGHT POIN
2025_MES_733606_1
94264/MRT/2025-26/E8
Open Tender
Civil Works
180 days
MEERUT CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (NORTH) MEERUT
₹1.1 L
Yes
19 Dec 2025
3 Oct 2025
18 Nov 2025
3 Oct 2025
12 Nov 2025
24 Oct 2025
Amount
Surface excavation in soft soil n.exc. 30 cm deep and averaging 15 cm deep and getting out in soil complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm soft/loose soil complete all as specified and directed.
M&L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundations, fillings, Mass concrete, footings etc complete all as specified and directed.
S&F Steel work in tubular trusses (minimum Post dia 150mm & height above GL 3-4m ) including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Roof trusses Fe 410 -W (Gde E- 250) quality A (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M&L for preparation of steel and iron surface exceedding 10 cm width or girth and applying two coas of synthetic enamel paint over one coat of red oxide zink chrome primer complete all as specified and directed.
Supplied and fixed fibre cement coloured textured designer ceiling board 4mm thick of size 595x595 mm conforming to IS : 14862 & IS : 2380 Part-XIV fixed to timber / GI / Aluminium frame work with screws/clips complete all as per manufactures instructions and as directed.
S&F GI snap grid frame work for false ceiling of size of grid 605x605mm all as specified and Hangers 2mm dia GI (upto 1200mm length) adjusting level fixed to steel frame work complete all as specified and directed.
M&L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundations, fillings, Mass concrete, footings etc complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100mm thick cement concrete Cement concrete as hard standing work type B- 2, 1:2:4 (using 40mm graded stone aggregate) including cutting of 30mm depth construction/ expansion joints complete all as specified and directed.
M&L for 75 mm thick PCC 1:2:4 type B:2 (using 40 mm graded stone aggregate) as in floor complete all as specified and directed.
Providing, cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point including loading/ unloading and stacking at the destination, all as directed by Engineer -in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.
M&L for Cement concrete type B2 1:2:4 (using 40mm graded stone aggregate) in surface channels and drains complete all as specified and directed.
Supplied and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with hot dip galvanised self dirilling and self tapping screws neoprene and EPDM washers complete all as specified, directed and as per manufacturer's instructions and height of buildings upto 15mtr with out stair case complete all as specified and directed.
Supplied and fixed pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with hot dip galvanised self dirilling and self tapping screws neoprene and EPDM washers complete all as specified, directed and as per manufacturer's instructions and height of buildings upto 15mtr with out stair case complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 20mm cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Machine pressed rubber moulded coloured glosy finished with epoxy coating precast concrete interlocking paver block, by using PU mounded of any shape and size IS of 60mm thickness M-35 Grade complete all as specified and directed.
M&L for sand filling under floors 50mm thick or in foundation including watering and consolidation complete all as specified and directed.
M&L brick work with fly ash old size bricks, straight or curved on plan exceeding 6 cm mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L 15 mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth complete all as specified & directed.
Preparation of new plaster surface of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
Excavation in trenches n. exc 1.50 m wide and n.exc 1.50 m in depth for foundation etc and getting out in hard & dense soil complete all as specified and directed.
Returning filling in hard/dense soil, including spreading, levelling, watering and well ramming in layer not exc 25 cm in each layer complete all as specified and directed.
Demolition of cement concrete of ground floor n exc 15 cm in depth in any position not otherwise specifically provided for complete all as specified and directed.
M&L cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) of 100 mm thick in floors complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal cross section area) single core, multi stranded PVC insulated, unsheathed copper conductor, FRLS cable in and including in rigid pvc conduit 20 mm dia or higher medium grade ISI marked complete with all conduit accessories / fittings and sunk pressed (1.2 mm thick) steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, including earth wire continuous of PVC insulated, unsheathed 1.5 Sqmm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic sheet screwed with brass screws, cup washers complete all as specified and directed for the following:-
One light/exhaust/ fan point controlled by one, one way switches 5/6 Amps complete all as specified and directed.
One 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch complete all as specified and directed.
All as per serial item No 29.02 above but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board complete all as specified and directed.
S & F Switch piano flush button single pole one way 5 amp complete all as specified and directed.
S & F Socket outlet 3 pin, 5 Amps, flush type complete all as specified and directed.
Supply & fixing of socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed.
Supply and fix in switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed.
S & F Ceiling rose, surface type, bakelite, 65 x 50 mm, three terminal complete all as specified and directed.
Supply & fixing LED tube light fitting T/5 surface mounting poly carbonate 240 volts 20 watts, 6500K complete all as specified & directed.
M&L for Building security light fitting 1 x 35 LED type, drawn through and including GI bracket of size 25 mm dia bore light grade 1.4 mtr long, bend to shape including MS clamps made out of flat iron of size 32 x 4 mm - 02 Nos and necessary nuts, bolts, washer as required complete all as specified and directed.
Supply only ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CMM with min service value 6 BEE 5 star rating, with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix sheet metal enclosure single pole & neutral for 240 volts 12 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
Supply and fix sheet metal enclosure single pole & neutral for 240 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA complete all as specified and directed.
Supply and fix MCB SPN 40 to 63 Amps, 240 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
M/L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wite 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specifiied or indicated including testing on completion.
Supply , Laying and testing cable XLPE insulated screened, PVC bedded, Galvanised steel srip or wire armoured electric power cable (Heavy duty) 1100 V Grade, aluminium conductor of size 6 sqmm 2 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out including foming of bottom surface for laying of cable / pipe etc in soft/loose soil and levelling of bottom surface to required level complete all as specified and directed.
Returning filling in including spreading levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exc 1.5M above the starting point complete all as specified and directed.
M&L for sand cushioning, spreading & levelling, watering and well ramming in layers for laying underground cable complete all as specified and directed. Note :- Only punned thickness shall be measured for payment purpose only.
Supplying & laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and directed.
Supply & Laying GI light grade tubing 40mm dia laid in trenches, road crossing , pasing through pipe or laid in wall/pole complete all as specified and directed.
M/s Dev Enterprises (BID ID -3463905)
UTTRAKHAND BUILDERS (BID ID -3464239)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TD1.pdf
Tender Documents • 0.42 MB
TD2.pdf
Tender Documents • 0.22 MB
TD3.pdf
Tender Documents • 0.24 MB
TD4.pdf
Tender Documents • 1.49 MB
BOQ_821407.xls
BOQ • 3.45 MB
Download all tender documents and submit your bid