Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC NO 6 BAJANAI KOIL CROSS STREET CHATHIRAM PATTABIRAM CHENNAI 600 072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹42.9 L+₹14,384.23 (0.34%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹44.0 L+₹1.2 L (2.90%)Rejected-AOC 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L3 | Rejected-AOC Rejected |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
19 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineers Navy
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
82512 ADDITION AND ALTERATION TO BUILDING NO.P-01 UNDER AGE (I) NAVY CHENNAI
2022_MES_526226_2
CA No.CWE/NAVY/CHN/82512/E8 of 2022-23
Open Tender
Civil Works
Item Rate
240 days
CHENNAI
As per tender Documents
9 documents required · 9 mandatory
₹500
AGE(I) NAVY CHENNAI
₹74,000
Yes
10 Aug 2022
28 Jun 2022
20 Jul 2022
28 Jun 2022
19 Jul 2022
28 Jun 2022
Amount
Demolition of Brickwork built in cement mortar, stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material and Labour for Brickwork with fly ash old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified and directed.
Ditto as in item No. 2 but for half brick thick walls built in CM (1:4) complete all as specified and directed.
Material and Labour for Removal of plant growth by injection with chemical glyphospate solution (4 % concentration) of 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm deep. The area shall then be sprayed with solution 25ml glyphosphate (4% concent) diluted with 1 ltr of water. All roots / plants shall be removed completely and making good with cement concrete/mortar and finished the surfaces matching to existing surfaces of wall / floor with acrylic paint all as directed by EIC. etc sectional area not exc 0.10 Sqm each complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for(reinforcement cut as required to facilitate) complete all as specified and directed
Material and Labour for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) n less than 0.9mm dia or securing with clips and including welded with new reinforcement to existing reinforcement and grouting of beams/ columns/lintels etc complete all as specified and directed
Material and Labour for reinforced cement concrete (nominal mix) Type B-1 1:2:4 (using 20mm graded stone aggregate) as in as slab suspended slab, chajjas, facia, shelves for cooking platform , platform and the like complete all as specified and directed
Material and Labour for formworks to sides and soffits of shelves, cooking platform and the like rough finished surface of concrete complete all as specified and directed
Material and Labour for Steel work in tabular/hallow sections of trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed.
Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50mm thick of any colour having tensile strength of 550 Mpa, as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Material and Labour for Providing & injecting ATT chemical at the point of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate 0.5 liters/holes by drilling 6mm dia holes at a downward angle of 45 degree at 150mm center and sealing the same complete all as specified and directed.
Material and Labour for Providing & injecting ATT chemical at the point of contact of voids in masonry wall and floor joins or perimeter of rooms using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed. Note:- Measurement to be consider only perimeter of wall and depth up 500 mm
Material and Labour for Providing and injecting chemical emulsion for Post on structural AntiTermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed. Note:- Measurement to be consider only perimeter of wall and depth up 500 mm
Material and Labour for Ready Mix Micro concrete of 25 to 40 mm thick consistency of Renderoc S2 or Renderoc RG of FOSROC in consistency a batch of 25kg of Renderoc mixed with water not exceeding 3.50 Ltrs all as per manufacturer's instructions and finished the surfaces even and smooth with 10mm thick rendering in CM 1:4 complete all as specified and directed by Engr-in-Charge including erecting necessary scaffolding (UP to G+5 Story ) Work to be carried out through FOSROC applicator only Note:- The following stages (a) to (d) are to be carried out for this item.:-
(a) Taking out existing unserviceable plaster loose/unsound weaken cement concrete of any description and in any position from existing surface of RCC roof slab/beam/column/RCC facia /RCC chajja with power driver of pneumatic chisel after cleaning of concrete/plastered particles and Removing corrosion and all loose scales rust etc from the visible reinforcement and cleaning the steel reinforcement properly.
(b) Applying one or more coat of NITO ZINK primer of FOSROC or equivalent ZINK primer of CHEMISTIC/WEBAC on visible reinforcement surface. Several time prior to placing, the concrete substrates should be saturated with clean water
(C) After drying of water to applying bonding agent of modified styrene butadiene emulsion (SBR bonding agent i.e. Nito bond SBR Latex or Nito bond EP of FOSROC) in proportion 1 (Nito bond SBR latex): 1 (water): 3 (OP cement) by volume with the brushing etc to bind New CM plaster / Polymer Modified plaster / Concrete / Screed concrete with old surface..
(d) Providing fiber mesh jali where required to fixed to existing RCC roof slab/beam/column/RCC facia /RCC chajja as per directed by Engr-in- Charge
Taking down cement Plaster , any description, on brick walls or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Material and Labour for 15mm thick Rendering on fair faces of brick work or concrete surfaces in CM (1:4) using with WPC @ 3% by wt of cement on second coat complete all as specified and directed. (Note : WPC shall be measured and paid separately)
Supply only Integral water proofing compound complete all as specified.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finished even and smooth (without using extra cement) complete all as specified and directed
Material and Labour for 5 mm thick rendering in CM (1:3) on ceiling on soffits and finished even and smooth (without using extra cement) complete all as specified and directed
Material and Labour for preparation of newly plastered / concrete surfaces and applying two coats of oil bound distemper over a coat of primer over 3mm thick wall care putty complete all as specified and directed.
Material and Labour for complete removal of existing surfaces including washing / rubbing down with water of wall and applying two coats of oil bound distemper/emulsion over coat of alkali resistant primer including chalk whiting 3mm thick wall care putty and including necessary scaffoldings as reqd etc complete all as specified and directed .
Material and Labour for Preparation of new surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. and over 1mm thick exterior wall care putty in two layers all as per manufacturer instruction and including necessary scaffoldings upto G+4 etc complete all as specified and directed.
Material and Labour for complete removal of existing treatment on walls including washing down, rubbing down and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. and over 1mm thick exterior Birla wall care putty in two layers all as per manufacturer instruction and including necessary scaffoldings upto G+4 etc complete all as specified
Material and Labour for Preparation new plastered surfaces plastered and applying three coat of white wash on ceiling complete all as specified and directed.
Material and Labour for Preparation Old decorated surfaces and applying two coat of white wash on ceiling complete all as specified and directed.
Material and Labour for Preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc primer complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and directed.
Material and Labour for glazed ceramic coloured design tiles 450x300mm x 7mm thick in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat of CM 1:4 10 mm thick complete all as specified and directed.
Taking up & down steel tubing bore of pipe 15 mm connections, including cleaning and removal to store complete all as specified and directed.
Ditto as in item No. 29 but for 20 mm dia
Ditto as in item No. 29 but for 25 mm dia
Supply and Fix 20 mm outer dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and composite pressure pipes including all Crimp type internal sealing Plastic metal Composite fittings (such as elbows, tees, reducers, couplers, short pieces, connectors, etc.) and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work) etc complete all as specified. having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
Ditto as in item No. 32 but for 25 mm outside dia
Ditto as in item No. 32 but for 32 mm outside dia
Ditto as in item No. 32 but for 40 mm outside dia
Ditto as in item No. 32 but for 63 mm outside dia
Cutting holes in brick walls exc half brick but not exc one brick walls built in cement mortar for inserting holdfasts/rafters/pipes etc and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required and including necessary scaffoldings upto G+2 etc complete all as specified and directed.
Supply and fix 20mm outside dia PPR Gate valves (brass insert) as per requirement of site fixed to PPR pipes complete all as specified and directed.
Ditto as in item No. 38 but for 25 mm outside dia complete all as specified and directed.
Ditto as in item No. 38 but for 32 mm outside dia complete all as specified and directed.
Ditto as in item No. 38 but for 40 mm outside dia complete all as specified and directed.
Ditto as in item No. 38 but for 63 mm outside dia complete all as specified and directed.
Supply and fix rotational moulded polyethylene water storage tank of 500 ltrs capacity (cylindrical vertical with closed top) including dismantling of existing tank including all fittings i.e. tank nipple, of 20/25mm dia Ball brass valves, high pressure, with polythene float and fly nut etc hoisted and fixed in position complete all as specified and directed.
Supply and fix in repair PVC pipe 160mm dia single socketed in any length with rubber joints fixed to walls with Special Stack clamps Ms flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
Ditto all as per item No- 44 above but refixing in same position complete all as specified and directed.
Supply and fix in repair PVC pipe 110mm dia single socketed in any length with rubber joints fixed to walls with special Stack clamps Ms flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
Supply and fix in repair PVC pipe 75mm dia single socketed in any length with rubber joints fixed to walls with special stack clamps Ms flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
Supply and fix for PVC (SWR) bends any radius bore of dia 160mm with access door complete all as specified and directed.
Supply and fix for PVC (SWR) bends any radius bore of dia 110mm with access door complete all as specified and directed.
Supply and fix for PVC (SWR) bends/ Shoes any radius bore of dia 110mm complete all as specified and directed.
Supply and fix for 75mm PVC (SWR) bends any radius bore of dia with access door complete all as specified and directed.
Supply and fix for 75mm PVC (SWR) bends any radius bore of dia complete all as specified and directed.
Supply and fix for 110 mm PVC (SWR) branch piece, Single Tor Y) equal or unequal of with access door complete all as specified and directed.
Supply and fix for 75 mm PVC (SWR) branch piece, Single Tor Y) equal or unequal of with access door complete all as specified and directed.
Supply and fix for 110 mm PVC (SWR) vent cowl complete all as specified and directed.
Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided and including removing of PCC Tiles and Existing roof treatment etc complete all as specified and as directed.
Material and Labour for 75mm thick PCC (1:2:4) type B-1 (20 mm graded aggregate) as in plinth protection and finishing the even and fair with out using extra cement etc and including cutting of construction joints every 2.5 mtr and filled with sealing compound grade B etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover filets complete all as specified and as directed.
Supply and Fix Hangers 6 mm dia G.I(upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I) flats 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed.
Supply and Fix Anodised aluminium snap grid frame work as required grid (size of grid 605x605 mm) ceiling complete all as specified and directed.
Material and Labour for (600x600mm) of 12mm thick Seamless calcium silicate ceiling made out of 1800x1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having fillips head with under head cutter at 200 mm centre to centre, including finishing the joints of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam les finish (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0 sqm each complete all as specified and directed.
Supply and Fix for Providing and fixing factory made UPVC white colour Sliding window, Three track, area not exceeding 2.00 Sqm each, made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories net opening will be measured for payment purpose.
Supply and fix for Factory made PVC fully glazed i.e. glass panes used instead of 5mm thick sheet panels PVC of louvered ventilator of 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour micron. complete all as specified and directed
Supply and fix for Powder Coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement complete all as specified and directed. Note: Thickness of powder coating not less than 50 micron.
Supply and fix for 5 mm thick sheet glass figured glass, pin head ,obscured or frosted, on one side type and aluminium glazing beads in square not exc 0.50 Sqm in each pane complete all as specified and directed.
Supply and fix for plain sheet glass, 5.5mm thick, ordinary quality in square not exceeding 0.5sqm in each complete all as specified and as directed
Supply and fix for plain sheet glass, 5.5mm thick, ordinary quality in square exceeding 0.5sqm in each complete all as specified and as directed
Removal of building materials/debris from 1.5mtr to a distance of out side of 5.0 KM etc complete all as specified and directed.
Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified.
Taking down carefully sub-main wiring of any description and making good to there disturbed surfaces to match the existing all as specified and as directed by EIC.
Material and Labour for sub main wiring (concealed) complete with two single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 6 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 runs of 6 sqmm & one run of PVC conduit shall be measured as single unit
Material and Labour for sub main wiring (concealed) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 run of 4 sqmm & one run of PVC conduit shall be measured as single unit
Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed.
Material and Labour for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed.
One light point controlled by one switch
One fan point controlled by one switch
One exhaust fan point controlled by one switch.
One switch socket outlet modular type 3 pin 6 amp on same board.
All as per item No.76 above but 1.5 sq mm cable size and 1.5 sq mm earth continuity wire for one 3 pin socket outlet, 6 amps on Independent board.
All as per item No.76 above but 2.5 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board.
Supply and Fix Switch modular type, single pole one way 6 Amps complete all as specified and as directed.
Supply and Fix 0-4 step, one module, modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts hum free single pole,complete all as specified and as directed.
Supply and Fix socket modular type 6 Amps multistranded 240 volts all as specified and as directed.
Material and Labour for ceiling rose, surface Bakelite, 65 x 50 mm, two to three terminals all as specified and as directed.
Supply and Fix switch modular type 16 Amps, 240 volts all as specified and as directed.
Supply and Fix socket modular type 16 Amps, 3 pin combine, 2 module, 240 volts all as specified and as directed.
Supply and Fix for Modular white cover plate with frame, 3 Module complete all as specified and as directed.
Supply and Fix for Modular white cover plate with frame,6 Module complete all as specified and as directed.
Supply and Fix for Modular white cover plate with frame,8 Module complete all as specified and as directed.
Supply and Fix for Modular Metal flush box, 3 Module complete all as specified and as directed.
Supply and Fix for Modular Metal flush box, 6 Module complete all as specified and as directed.
Supply and Fix for Modular Metal flush box, 8 Module complete all as specified and as directed.
Supply and Fix wall mounted LED batten with decorative end cap of capacity 4feet 20W or nearest higher wattage, 2500 lm, 6500 K suitable for Surface, Wall & Conduit mounting complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and lamp complete all as specified and directed internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and directed Make : C&S Cat Part No. LTTB4F20WLED/W or equivalent as mentioned in PS
Supply and fix LED light fitting 2 feet,10 W or nearest higher wattage, 230v, suitable for Surface, Wall & Conduit mounting, with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : C&S Electric Cat Part No. LTTB2F10WLED/W or equivalent as mentioned in PS
Supply and Fix sheet metal enclosures for DB's for incorporating MCBs, VTPN, 6 way, IP-43 with metal double door with 200 amps rated busbar, 415 volts, as per IS-8623 including taking down the old unserviceable TPN DB, all as specified and as directed.
Supply and Fix MCB TPN, 100 Amps, breaking capacity 10 KA, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. complete all as specified and as directed.
Supply and Fix MCB TPN, 32 Amps, breaking capacity 10 KA, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. complete all as specified and as directed.
Supply and fix exhaust fan 300mm sweep, heavy duty, single phase, Rust proof body and blades, double ball bearing with noiseless operation, 1400 RPM complete with louvers including making suitable opening at suitable height, and provision of nuts and bolts on the wall for fixing the exhaust fan complete all as specified and as directed . Note: The rate quoted shall be deemed to be inclusive of cuttings of holes in PCC or through bricks walls of appropriate dia suitable making niche for 300 mm sweep exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B0 as required including making good as per existing surface colour matching of wall including 4 Nos of nut & bolts to fix the Exhaust fan complete all as specified and as directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 4 mm GI wire as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 in SSR part 1 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 15 mm GI pipe (Medium grade) for protection of earth wire and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicable complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron or steel wire all as specified and as directed.
Taking down fan, dismantling blades and removing fan and blades including repair and servicing, painting of ceiling fan complete all as specified and as directed.
Tacking down / Removing carefully of split type Air conditioner 1.5/2 ton capacity and including Refixing of indoor and Outdoor unit and including duly making holes into wall, Gas charging, copper pipe, pipe insulation material, drain pipe and 3 core cable, and making good the disturbed surfaces complete and including servicing the entire unit all as specified and directed.
Supply and laying LT UG XLPE insulated of size 50 Sqmm 3.5 core 1100 volt grade heavy duty cable multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and connecting up to the electrical system with suitable size of aluminium lugs complete all as specified and directed. (Note: Earthwork, excavation, RFR and removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection if required shall be measured and paid seperately under relevant items)
Taking out existing LT cable off sizes up to 300 Sqmm from duct/wall/floor/ trenches and re-laying the same serviceable cable after fault rectification in existing position with supply and fixing connecting materials such as thimbles, lugs, nuts, bolts and washers as required at site all as specified and directed.
Supply and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 40 mm bore for erection of lightening conductor and protection for earth strips etc and including short lengths, with all pipe fittings such as ends, elbows, unions, tees, reducing tees, adopters, sockets, plugs, hose clips etc. and fixing to walls etc. complete with saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves and cutting through walls, floors and their making good or laying in trenches and also cutting, screwing and waste complete as required and directed.
VIJAYALAKSHMI ENTERPRISES
SIRITEL SYSTEMS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .