| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC N A | NEW DELHI | DELHI | 110001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.0 L+₹1.3 L (6.72%)Rejected-AOC SHOP NO 6 GROUND FLOOR SHRI KRISHANA BUILDING OPP NANKING HOTEL VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L2 | Rejected-AOC HIGHER BIDDER | |
| 3 | L3₹22.4 L+₹2.8 L (14.2%)Rejected-AOC | L3 | Rejected-AOC HIGHER BIDDER | |
| 4 | L4₹23.0 L+₹3.4 L (17.3%)Rejected-AOC MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L4 | Rejected-AOC HIGHER BIDDER | |
| 5 | L5₹23.3 L+₹3.6 L (18.5%)Rejected-AOC FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-AOC HIGHER BIDDER |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
16 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI JANAK RAJ EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8355/E8
2021_MES_445902_2
8355/E8
Open Tender
Civil Works
Item Rate
30 days
VASCO
Class E Category a i
8 documents required · 8 mandatory
₹500
Yes
GE NW VASCO
₹39,000
Yes
22 Jul 2021
29 Jun 2021
19 Jul 2021
29 Jun 2021
16 Jul 2021
3 Jul 2021
29 Jun 2021 - 3 Jul 2021
60 days
Amount
Dismantling/Taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled as directed by Engineer-in-Charge.
M&L APP based polymeric membrane minimum veight 3kg/sqm and minimum 3mm thick reinforced with polyster non- woven fabric (wt. not less than 150gms/sqm) laid on primed surface by torch application method with minimum side overlap 100mm and 150mm as end lap over roofs after cleaning the surfaces properly with water and allowed to dry completely including priming surfaces for applying heavy treatment complete all as specified and as directed.
M & L rendering 10mm thick (avg) on concrete surfaces over roof slabs, in cement mortar 1:4, mixed with liquid water proofing compound, finished even and smooth without using extra cement, to receive roof treatment complete all as specified and as directed. (Note: - water proofing compound shall be measured and paid separately)
Supply only liquid waterproofing compound.
Taking down cement plastering of any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed.
Providing 10mm thick plaster in CM (1:6) finished to even & smooth w/o using extra cement.
Preparing newly plastered surfaces of wall and applying two coats of Oil bound distemper over a coat of alkali resistant primer.
Disconnecting existing water tanks of size exc. 250 ltr but n.exc. 500 Ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc
All as per item No. 8.00 above but of size exc. 500 ltr but n.exc. 1000 Ltr capacity.
Cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes etc. of capacity exc. 250 ltr but n.exc 500ltr and refixing in position.
All as per item No. 10.00 above but of size exc. 500 ltr but n.exc. 1000 Ltr capacity.
S & F in repairs Ball brass valves 15mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed.
Taking up/down old GI tubing and connection of size 15mm bore, including cleaning for refixing, complete all as specified and as directed.
Taking up/down old GI tubing and connection of size 20mm bore, including cleaning for re-fixing, complete all as specified and as directed.
CPVC water tubing 15mm bore, (20mm outer dia) SDR-11 grade with all fittings and fixed complete to wall/Ceilings or laid in floors all as specified and as directed
CPVC water tubing 20mm bore, (25mm outer dia) SDR-11 grade with all fittings and fixed complete to wall/Ceilings or laid in floors all as specified and as directed.
Dismantling of old PVC tanks with 500 Ltrs capacity
S & F rotational moulded polythene water storage tanks with (cylindrical vertical with closed top) hoisted and fixed in position all as specified 500 ltr capacity.
Dismantling of plain corrugated steel sheeting any thickness including similar pattern roof coverings.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws all as specified & directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws all as specified & directed.
M & L for rolled mild steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc; conforming to Fe 410-W(Gde-E- 250)
Dismantling structural steel work including doors, gates framed truss etc
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs / blankets, any thickness, including frame work cover fillets
M & L providing Aluminium (powder coated) snap grid frame work in repair for false ceiling of grid size 605 mm x 605 mm complete all as specified and as directed.
M & L 12mm thick Perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid fixed in repair. (Note: Aluminium grid shall be measured separately under relevant item of this Schedule if required)
M & L 12mm thick Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid. (Note: Aluminium grid shall be measured separately under relevant item of this Schedule.)
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;
Demolition of laterite stone masonary walls built in CM and removing the debries to a distance not exc 500 M as directed.
Pre - cast cement concrete 1:3:6 masonry with Grade C-5.0, (20mm graded stone aggregate) with solid blocks wall built in cement mortar 1:6
M&L rendering 10 mm thick in CM 1:4 on concrete surfaces finished even and smooth without using extra cement.
M/s. R.S. LAWANDE
M/S G.N.POWAR
Super Construction
M/s J.D. DESAI
K M Subhanaiah
M/S jvsr constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .