Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹46.8 L+₹2.0 L (4.40%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹50.7 L+₹5.9 L (13.2%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹59.0 L+₹14.3 L (31.8%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L4 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹49.8 L
EMD Value
₹1 L
Closing Date
25 Oct 2021, 6:00 pmClosed
ARJUN PATRO,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
REPAIR AND MAINTENANCE LT PANEL, ACBS, MCCBS, EARTHING AND CONNECTED ITEMS AT 4 NO PF, STATION ROAD, MAUDE ROAD, CHURCH ROAD, CASSEL ROAD, MANEKSHAW ENCLAVE, MANEKSHAW CENTRE, MALL ROAD, POLO ROAD, TIGRIS ROAD, MANDIR MARG, HARBAKSH STADIUM, PARADE R
2021_MES_462044_2
GE ELECT/D-61/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹1 L
Yes
2 Nov 2021
5 Oct 2021
27 Oct 2021
6 Oct 2021
25 Oct 2021
13 Oct 2021
Amount
(b) Outgoing (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 06 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
S&F in replacement of UNSV MCCBs of capacity 630 Amps, TP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed
All as per ser item No 10 here in before , but rating of MCCB 400 Amp, 36 KA
All as per ser item No 10 here in before , but rating of MCCB 250 Amp, 36 KA
All as per ser item No 10 here in before , but rating of MCCB 200 Amp, 25 KA
All as per ser item No 10 here in before e, but rating of MCCB 160 Amp, 25 KA
All as per ser item No 10 here in before , but rating of MCCB 125 Amp, 25 KA
All as per ser item No 10 here in before but rating of MCCB 100 Amp,25KA
All as per ser item No 10 here in before but rating of MCCB 63 Amp, 25 KA
S&F in replacement of UNSV MCCBs of capacity 630 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed
All as per ser item No 18 here in before but rating of MCCB 400 Amp, 36 KA
All as per ser item No 18 here in before but rating of MCCB 320 Amp, 36 KA
All as per ser item No 18 here in before but rating of MCCB 250 Amp, 36 KA
All as per ser item No 18 above but rating of MCCB 200 Amp, 25 KA
All as per ser item No 18 here in before but rating of MCCB 160 Amp, 25 KA
All as per ser item No 18 here in before but rating of MCCB 125 Amp, 25 KA
All as per ser item No 18 here in before but rating of MCCB 100 Amp, 25 KA
All as per ser item No 18 here in before but rating of MCCB 63 Amp, 25 KA
S&F in renewal on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed
All as per ser item No 27 here in before but 250 Amps 4 pole
All as per item No 27 here in before but 200 Amps 4 pole
S&F on load change over switch with SS enclosure of capacity 125 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and bolts after taking down old existing un serviceable MCCB/SDFU complete all as directed.
Supply and fixing in renewal of 3 pole power contactor ML-6 Cat No SS90921 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as directed.
Supply and fixing in renewal of 3 pole power contactor MNX-110 Cat No CS94137 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as directed.
Supply and fixing in renewal of Analog Time switch Cat No J648B1, 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable time switch complete all as directed.
Supply and fixing in replacement LT current transformer having ratio 400/5 Amp , 15 VA, Class 0.5. Complete all as specified and directed by Engr-in-Charge
All as per Srl item No.34 herein before but CT ratio 250/5 Amp
All as per Srl item No.34 herein before but CT ratio 200/5 Amp
Supplying installation testing of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm thick CRCA MS sheet and 25x25x5 mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 450x400x300mm having 4 Nos angle iron legs of size 25mm x 25mm x 5mm of length 75mm including 4 Nos 200 Amp aluminium bus bar fitted with 01 No MCCB ,160 Amps TP ,25 KA, 415 V, 50 Hz as incommer Platform for the bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supplying installation testing of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm thick CRCA MS sheet and 25x25x5 mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 450x400x300mm having 4 Nos angle iron legs of size 25mm x 25mm x 5mm of length 75mm including 4 Nos 200 Amp aluminium bus bar fitted with 01 No MCCB ,160 Amps TP ,25 KA, 415 V, 50 Hz as incommer Platform for the bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
S&F in replacement ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type , front operated with Micro processor based protection release for adjustable over current, short circuit and earth fault protection
S&F in replacement of UNSV MCCBs of capacity 250 Amps, TP, 35 KA, 415 Volts 50 Hz, AC, with microprocessor release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed
All as per ser item No 40 here in before , but rating of MCCB 200 Amp, 35 KA
All as per ser item No 40 here in before , but rating of MCCB 160 Amp, 35 KA
All as per ser item No 40 here in before , but rating of MCCB 125 Amp, 35 KA
All as per ser item No 40 here in before , but rating of MCCB 100 Amp, 35 KA
All as per ser item No 40 here in before , but rating of MCCB 63 Amp, 35 KA
S&F in replacement of UNSV MCCBs of capacity 400 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with microprocessor release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as directed
All as per ser item No 46 here in before e but rating of MCCB 250 Amp, 35 KA
All as per ser item No 46 here in before , but rating of MCCB 200 Amp, 35 KA
All as per ser item No 46 here in before , but rating of MCCB 125 Amp, 35 KA
All as per ser item No 46 here in before , but rating of MCCB 100 Amp, 35 KA
All as per ser item No 46 here in before , but rating of MCCB 40 Amp, 35 KA
Material and labour disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.
Supply and fixing in replacement of cable gland for LT panel/feeder pilar up to 50 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 70 sqmm cable to 240 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel for 300 sqmm cable to 400 Sqmm cable complete all as specified and directed.
Material and labour in replacement of Voltmeter 0-500 V digital type as per existing size complete all as per specified and directed.
Material and labour in replacement of Ammeter 0-400/800 Amp digital type per existing size complete all as per specified and directed
Supply and fixing in replacement of indicator lamp for RYB phases complete all as specified and directed.
Supplying and fixing in replacement kit kat rewireable porcelain fuse carrier & base 63 Amps , 415 Volt complete all as directed .
Supplying and fixing in replacement kit kat rewireable porcelain fuse carrier & base 100 Amps , 415 Volt complete all as directed .
Supplying and fixing in replacement MCB 4 pole , 63 Amps, 10 KA ,50 Hz,415 Volts
Supplying and fixing in replacement MCB 4 pole , 32 Amps,10 KA,50 Hz,415 Volts
Supplying and fixing in replacement MCB DP , 63 Amps,50 Hz,10 KA,240 Volts
Supplying and fixing in replacement MCB DP , 6 to 32 Amps,50 Hz,10 KA,240 Volts
Supplying and fixing in replacement MCB SP , 6 to 32 Amps,50 Hz,10 KA,240 Volts
Supplying and fixing in replacement Mild steel sliding door bolts 200 mm long ,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate
Supply & Fix in replacement Transparent KIOSK box weather proof incluiding made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120 mm out side and 300x200x105 mm inside dimensions comprising of aluminium bus bar 4 strip for 3 phase and neutral 63 Amps and incluiding embossing/ painting of danger notice of size not less than 10cm x 7.5 cm with letters,figures band conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer.
M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters as directed.
All as per item No 70 here in before but of approx size upto 1.90 Sqm
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I-2009, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 450mm x 450mm x 300mm with 4 Nos 500 Amps aluminium bus bar and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded stone aggregate, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply and fix in replacement MCCB 63 Amp, 4 pole , 25 KA, 50 Hz including MCCB sheet metal enclosure mounted on wall with fastner and suitable size of nut and bolts complete all as directed .
Supply and fix in replacement MCB 63 Amp, DP , 10 KA, 50 Hz including MCB enclosure mounted on wall with fastner and suitable size of nut and bolts complete all as directed .
Supply and fix in replacement outdoor type wall mounted Busbar chamber having 04 pole busbar of rating 200 amps fitted with MCCB 100 Amp, 4 pole , 25 KA, 50 Hz as incomer incuding suitable hole in bus bar for outgoing cable connection including suitable size nut bolt and fasyner complete all as directed at site by Engr -in-charge.
Supplying , installation, testing and commissioning of 11 KV, 630 Amps having short circuit capacity 20kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 7-way comprising of 02 Nos motorized operated Load Break Switch and 05 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank with min. thickness 3+0.5 mm, IP 67 Degree of Protection , internal-arc classified 20kA/1sec, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit alongwith Bus-connected, fixed-type Auxiliary transformer shall include the following along with all necessary accessories and fittings as required at site.
(A) 02 Nos. Incoming Load Break Switch module each consisting of following accessories :- (i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 20kA/3-sec, Making Capacity - 50kAp -01 No (iii) Auxiliary contacts - 1NO + 1NC-01 No (iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 300 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 (vi) Right angle boots (push on type)-Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No
(B) 03 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 20kA/3-sec, Making Capacity - 50kAp-01 No (iii) Aux. contacts - 1NO+1NC-01 No (iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 185 Sqmm , 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 (vi) Right angle boots (push on type)-Each set of 3 (vii) 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol-01 No (viii) Associated ring-core cast-resin insulated CTs 50/1 Amp , 2.5 VA, 10P10 for protection - Each Set of 3 (ix) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (x) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (xi) Push button for breaker trip (xii) Shunt trip coil 24V DC - 01 (xiii) ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. (xiv) Emergency Trip Push Button - 01.
(C) 01 No. Bus-connected, fixed-type Auxiliary transformer with floor-mounted compartment of matching height and depth, positioned along-side RMU or on the top of the RMU to provide required aux. supply and metering consisting of following accessories :- (i) 1-Ph (11kV/rt3):230VAC, 500VA Auxiliary transformer-01 No (ii) 2x12 Volt DC battery-01 Set (iii) Battery charger-01 No (iv) HRC fuse-links for primary side isolation and AC/DC MCBs for secondary isolation-01 Set (v) Voltmeter & RYB LED Indications to confirm AC/DC supply availability-01 Set (vi) Anti-condensation space-heater-01 No (vii) CFL lamp for illumination and 3-pin socket with switch -01 No
(D) Additional equipment deliverd separately or mounted seperately :- (i) Operationg Handle for Manual Isolator/Disconnector/Earthing Operation-02 Nos (ii) Standard Manometer -01 No (iii) Operation and Maintenance Manual -01 No (iv) Installation & Commissioning Manual -01 No (v) Cable clamping provision (standard) -01No
Note:- (i) It is preferable to have all feeder-switches inside single stainless steel compartment with incomer feeders at the extremities to prevent chances of failure due to plug-in coupling arrangement. (ii) Necessay interclocking arrangement shall be provided for safety and operations (iii) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. Any claims towards internal arc compliance, number of mechanical/electrical/short-circuit operations, gas-leakage rates etc. shall not be accepted unless proven via type-test reports of model being offered. (iv) Cost of provn of plinth for RMU as per OEM drawing is deemed to be included in the cost.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm .
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm .
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 Sqmm to 185 Smmm.
NOTE :-(i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
Rajindera Enterprises
Vijay Electricals
mayur enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .