Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
8 Dec 2020, 6:00 pmClosed
GE (AF) Bihta
GE (AF) Bihta Pin-801103
Repair/Maint of AC Water Coolers, Refrigerators, Voltage Stabilizer of various capacity and connected items at AF Stn Bihta under GE (AF) Bihta
2020_MES_393187_1
8112/BHT/E8
Open Tender
Miscellaneous Works
Works
120 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹10,000
Yes
23 Dec 2020
6 Nov 2020
10 Dec 2020
6 Nov 2020
8 Dec 2020
20 Nov 2020
Amount
Desert Cooler: Material and labour for, taking down desert cooler from foundation, dismantling opening the same for complete servicing by scrapping of rusted/deposits in side and outer surface of desert cooler, replacement of wornout, MS Nut bolt, wahser etc, oiling greasing of fan bearings, bushes etc and part of the body by providing new GI/MS sheet including necessry mechinary works as cutting/welding/finishing etc and preparation of internal and external surface of desert cooler and applying two coats of synthetic enamel paint of desire or existing colour.over a coat of red oxide primer,assembely the desert cooler and tested in the presence and to entire satisfaction of Engineer-in-charge to mke functional functional and re-install in same or other location as directed complete all as specified and directed by Engineer-in-charge. Note : (i) Spare parts/ Items required to made the desert cooler functional shall be measured and paid separately under appropriate items .
S & F submersible pump single phase 18 watt 220 volt 50 HZ as per existing size & specification including taking out the old one all as specified and directed .Make- Crompton Greaves /Bajaj/ Usha/Khaitan
S & F single phase motor for desert cooler of 150 watt 220 volt 50 HZ of existing size and specification including taking out the old one all as specified and as directed Make- Crompton Greaves/Bajaj/Usha/Khaitan
S&F Exhaust fan blade 500 mm sweep three blade of existing size & specification for desert cooler including taking out the old one all as specified and as directed
S&F Cooling pad (Grass) for desert cooler with wire mesh square shape fixied on all the side (Three) as approved by Engineer-in-charge including taking out the old one all as specified and as directed
S&F flexible PVC pipe for desert cooler for water circulation on grass pad connected through Submersible pump to cooler top end Cooling pad (Grass) including PVC elbow and Junction box of existing size and specifications including taking out the old one all as specified and as directed
S&F stepped Rotary switch for desert cooler as per existing size & specification including taking out the old one complete all as specified and directed. Make:Havells/Plaza/Leader/SSK
S&F switch plano flush button single pole one way 6 Amp, 230 volts for desert cooler including taking out the old one complete all as specified and directed. Make ; Havells/Plaza/Leader/ SSK
S&F Top plug 6 amps 3 pin , 240 Volts complete with connecting PVC 3 core flexible copper wire of maximum 2 m length of suitable capacity including taking out the old one complete all as specified and directed. Make ; Havells/Plaza/Leader/ SSK
AIR CONDITIONER/WATER COOLER/ REFRIGRATOR : Material and labour for disconnect electric connection, taking down/ keep aside the air conditioner (Split/Window) type, Water Cooler and Refrigerator including stabilizer of any make and capacity. Servicing the same by cleaning inside, cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gas kit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and tested in the presence and to entire satisfaction of Engineer-in-charge, made it fullyand Re-installation in position complete all as specified and directed by Engineer-in-charge. Note: All new spare parts required to make the items fully functional will be measured and paid separately under the appropriate items as supply only)
Material and labour for detection and rectification of leakages in gas line by necessary brazing in 1.5 Ton/2.0 Ton window / split type AC of any model and any make and ensuring the complete systems leak proof including checking the system and replacement of required spare parts including charging of refrigerant gas R-134 A with appropriate quantity including testing for smooth functioning all as specified and directed. Note: Spare parts, if requited will be measured and paid separately under the supply of appropriate items.
Material and labour for Dismantling of unserviceable/worn hermetically sealed unit compressor from window /Split type AC and replacement with new one compressor (company repaired), suitable for existing same model/make of capacity 1.5 TR split/window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduing charging of refrigerant gas R-134 A in appropriate qty after making vacume the complete system and tested in the presence and to entire satisfaction of Engineer-in-charge, make it fully functional and Re-installation in position complete all as specified and directed by Engineer-in-charge. Make:: Kirloskar ) / Techumesh / Carrier / Blue Star/LG/Sri-ram)
All as per item no-12 here in before of Capacity 2.0 TR split type AC
Supply only followings spare parts required for repairs for window /split type AC of any capacity taken down foeservicing/repair vide item No 10 here -in -before complete all as specified and directed by Engineer -in- Charge Note : All the repairs shall to be carried out at AGE E/M store yard Note : Transporting charges from site to yard and vice versa shall be included in quoted unit rate..(a) Supply only copper cooling coil complete with fins suitable upto 2Ton/1.5 Ton capacity Window/Split type AC.as per existing size and specification. Make : LG/ Voltas/Hitachi.
(b) Supply only Copper condensing coil complete with fins copper suitable for 2Ton/1.5 Ton capacity Window/Split type AC.as per existing size and specification. Make : LG/ Voltas/Hitachi.
(c) Supply only fan motor for water cooler of suitable capacity. Make : CG/ Kirloskar/Khaitan.
(d) Supply only fan blade suitable for AC's blower/ water cooler motor and all as per sample.
(e) Supply only Copper condensing coil suitable for water cooler upto 120 Ltr capacity. Make :Kirloskar/ Voltas/Blue StarHitachi.
(f) Supply only Copper cooling coil suitable for water cooler upto 120 Ltr capacity . Make : Kirloskar/Voltas/Blue Star/Hitachi.
(g) Supply only Water outlet tap made of brass cromium plated for water cooler upto 120 Ltr capacity. Make : Voltas/Blue Star.
(h) Supply only unserviceable wall mounted stand of splite type AC of 2Ton/1.5 Ton capacity.
(j) Supply only Copper valve for liquid line for ACs upto 2Ton capacity.
(k) Supply only cooper valve fo refrigerant line suitable for ACs upto 2Ton capacity.
(l) Supply only Foam insulation heavy duty for ACs refrigerant line.
(m) Supply only Capilary tube for water cooler/ refrigerator/AC all as per exiting size specifications.
(n) Supply only Vegitable tray for refrigerator as per sample upto 320 Ltr capacity.
S & F Running capacitor 80/100 mfd + / - 400 V AC, Suitable for 1.5/2.0 TR window / split type AC including taking down unserviceable old one complete all as directed. Make : Asian / BHEL / GE / Cromplton Greave.
S & F Starting capacitor 80/100 mfd +/-5% 400 V ACSuitable for 1.5/2.0 TR window / split type AC including taking down unserviceable old one omplete all as directed. Make : Asian / BHEL / GE / Cromplton Greave.
S & F Over load Relay including taking down unserviceable old one complete all as directed. Make: -INDOFOS/SHRIRAM/USHA/)
S & F Thermostat switch ( DT 50-1052), suitable for 1.5 Ton/2 Ton split / window type AC. including taking down unserviceable old one complete all as directed. Make: -INDOFOS/SHRIRAM/USHA/.
S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hz as per exisying sample for indoor unit including taking down unserviceable old one complete all as directed. Make: Universal / Compton Greaves/Air Fresh.
S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hz as per exisying sample for outdoor unit including taking down unserviceable old one complete all as directed.Make: Universal / Compton Greaves/Air Fresh.
S & F Stainer/Filter (copper) Suitable for window type AC of 1.5/2.0 TR cooling capacity including taking out the old one.complete all as directed.
Supply and Fixing Electronic Circuit plate (PCB) for Split/Window A/C 1.5 TR/2 TR including taking down unserviceable old one complete all as directed.Make- LG /Carrier/ Samsung
Taking out the unserviceable sealed compressor unit from water cooler and .S&F New Sealed compressor unit company repaired of existing sample, suitable for 40/80 Ltr capacity of water cooler. replace with New compressor (duly tested)and checking the complete system for leak proof and including charging of refrigerant gas R-134 a in appropriate quantity and testing for smooth functioning complete all as directed.
M & L detection and rectification of leakage in gas line by necessary brazing /soldering in water cooler of any capacity ,any type and any make and ensuring the system leak proof and replacement of required spare parts Including charging of refrigerant R-134 A in appropriate quantity in the system and testing for smooth functioning of W/C complete all as directed.
Supply and fixing Running capacitor 25/30 mfd ± 5% ,400 volt for Water Cooler having capacity 40/80 and 150Ltr iincluding taking down unserviceable old one complete all as directed. Make : Usha/ voltas/ Asian
Supply and fixing over load Relay for Water Cooler having capacity 40/80 and 150Ltr including taking down old one complete all as directed. Make : Usha/,voltas/,Asian
Supply and fixing Float valve of 15mm dia non-metallic for Water Cooler having capacity 40/80 and 150Ltr including taking down old one complete all as directed. Make : Prayag /shakti /Poytuff
Supply and fixing PVC connection of size 15mm dia for Water Cooler having capacity 40/80 and 150Ltr including taking down unserviceable old one complete all as directed.Make : prayag /shakti /Poytuff
Supply and fixing PVC waste pipe of size 25 mm dia for Water Cooler having capacity 40/80/150 liters including taking down unserviceable old one complete all as directed.Make : prayag /shakti /Polytuff
M&L for detection and rectification of leakages in gas line by necessary brazing in refrigerator of 300/310Ltr capacity of any model and any make and ensuring the complete systems leak proof including charging of refrigerant gas R-134 A with appropriate quantity including testing for smooth functioning and checking the system and replacement of required spare parts and complete all as specified and directed. Note: Spare parts like filter, capillary tube, cooling coiled, condensing coil if required to make the refirigerator fully functional will be measured and paid separately
M& L for replacement of relay, suitable for 300/310 Ltr refrigerator of any make/model including taking down unserviceable old one complete all as directed. Make: Sri RAM/Usha /Renutrol /Indofos)
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down old one complete all as directed.Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit. Make : Havells/Universal/RR cable/Finolex
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4 sqmm as current carrying conductor and one run of 4.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm all as specified and directed including taking down old one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit. Make : Havells/Universal/RR cable/Finolex
S&F MCB’s single pole, 10 KA ,6 Amp to 30 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996.the power loss per pole shall be low and shall be in accordance with IS 8828-1996,All cable entries shall be either from bottom or top .MCB shall be of C curve charactertics & shall have quick make and break non welding self wiping silver alloy contact for 10 KA short circuit both on manual & automatic operation . including taking down old one complete all as directed. Make:Sheineder/Legrand /L & T/ABB
S&F MCB’s single pole and neutal, 10 KA ,32 Amp to 40 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996.the power loss per pole shall be low and shall be in accordance with IS 8828-1996,All cable entries shall be either from bottom or top .MCB shall be of C curve charactertics & shall have quick make and break non welding self wiping silver alloy contact for 10 KA short circuit both on manual & automatic operation .All the active ,live parts of MCBs should be out of human reach ,ensuring safty & conforming to IP 55 degree of protection . including taking down old one complete all as directed. Make:Schnieder/Legrand /L & T/ABB
S&F Sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete with one singlle pole MCB of "C" series of cap 16-32 Amp including taking out the old one all as specified and AS directed Make - Legrand / L&T/ Havells
BRIJESH ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .