Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.0 LAccepted-AOC N A | PALWAL | HARYANA | 121004 | 1 | Accepted-AOC Due to L1 | |
| 2 | 2₹16.1 L+₹1.1 L (7.17%)Rejected-Finance 126 RAJ KUMAR SANGAT SINGH NAGAR ADARSH NAGAR JALANDHAR JALANDHAR PUNJAB 144008 | JALANDHAR | PUNJAB | 144008 | 2 | Rejected-Finance L2 | |
| 3 | 3₹16.9 L+₹1.8 L (12.3%)Rejected-Finance DHALIWAL | TARN TARAN | PUNJAB | 143107 | 3 | Rejected-Finance L3 | |
| 4 | 4₹17.1 L+₹2.1 L (13.7%)Rejected-Finance ESD NO II UHL STAGE III BVPCL CHULLAH | LANGNA | MANDYA | KARNATAKA | 571401 | 4 | Rejected-Finance L4 |
Tender Value
₹19.4 L
EMD Value
₹38,726
Closing Date
26 Feb 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Jal Shakti Division Amb
Sub Head Construction of OHSR 70,000 Ltr. With 15 mtr. Staging height Village Dhandri
2024_HPIPH_85904_1
EEJSVD-Amb-C/O OHSR 70,000 Ltr.
Open Tender
Civil Works
Item Rate
90 days
Amb
Please refer Tender documents.
6 documents required · 6 mandatory
₹400
EE JSD Amb
₹38,726
27 Jun 2024
15 Feb 2024
26 Feb 2024
15 Feb 2024
26 Feb 2024
15 Feb 2024
Amount
Excavation in foundations, trenches etc., in earth work. In all kind of soil such as spad work, pick work, jumper work, blasting work in soft and hard rock chiselling / wedging out of rock where blasting is prohibited and in saturated soil etc. in all leads and lifts, stacking the excavated soil not more than 3 metres clear from the edge of excavation and then returning the stacked soil in fifteen centimetre layers,when required into plinths sides of foundations etc. consolidating each deposited layer by ramming and dewatering and then disposing of all surplus excavated earth as directed within all leads and lifts as per direction of the Engineer-in-Charge.
Providing and laying cement concrete using M-20 grade (With graded stone aggregate of 20 mm nominal size ) with minimum & Maximum cement contents of 250 Kg/M3 and 400 Kg/ M3 respectively and maximum water cement ratio 0.50 as per IS:3370 (Part-1) 2009 and curing complete excluding the cost of form work in foundation and plinth within all leads & lifts as per the direction of the Engineer-in-Charge.
Providing and laying cement concrete using M-30 grade (With graded stone aggregate of 20 mm nominal size ) with minimum & Maximum cement contents of 320 Kg /M3 and 400 Kg/ M3 respectively and maximum water cement ratio 0.45 as per IS: 3370 (Part-1): 2009 and curing complete excluding the cost of form work and reinforcement within all leads & lifts as per the direction of the Engineer-in-Charge.
Foundation, footing bases of columns and the like and mass concrete.
Foundation, footing bases of columns and the like and mass concrete.
Lintels, beams,girders,bressumer and cantilever.
Stair case(except spiral stair case)excluding landing but including preparing of the surface and finishing of nosing.
Arches upto all heights.
Suspended floor roofs, landing and shelves and their support balconies, beam girderes bressumers and cantiliver.
Wall ( any thickness but not less than 0.10 mtrs thickness attached pilasters butteress, plinth and string courses etc. from top of foundation level.
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30 x 30 x 5 mm, so as to give a fair finish including centring , shuttering, strutting and propping etc with wooden battans and ballies height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu-reinforced concrete and plain concrete work in all leads and lifts & as per the direction of the Engineer-in-Charge.
Foundation , footings , basis of columns etc. and mass concrete.
Columns,pillars posts,struts circular or curved in plan.
Sides and soffits of beams,beam haunching , cantiliver,bressumers & lintle not exceeding 1.00 mtr. Depth in all height. of floors.
Vertical surfaces such as wall of any thickness, partition and the like inculding pillasters,buttresses, plinth ande string courses and the like..
Flat surfaces such as soffits of suspended floors, roofs, landings and the like.upto 200 mm thickness.
Stair cases with slopping or stepped soffits excluding landings.
Providing of form work of ordinary timber planking so as to give a rough finish including centering, shuttering , strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 6 mtrs. and removal of the same insitu reinforced concrete and plain concrete work in all leads and lifts and as per the direction of the Engineer- in - Charge in Arches exceeding 6 mtrs span.
Steel work welded in built up section , trusses and framed work i/c cutting hoisting fixing in position and applying a priming coat of red lead paint in gretings, framed guards, bors ladders railing brackets and similar works.
Providing Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete in all respect in all leads and lifts & as per direction of the Engineer-in-Charge floor two level.
Providing plinth protection 50 mm thick in cement concrete 1: 3: 6 (1cement : 3 sand : 6 graded stone aggregate 20 mm nominal size ) including entire carriage of material and as per direction of the Engineer-in-Charge.
Providing under layer for plinth protection of 75 mm thick ( unconsolidated )bed dry brick/ stone aggregaated 40 mm nominal size will rammed and consolidated and grouted with fine sand including preparation of ground.
Providing and fixing MS manhole cover of 500 mm dia with frame ( medium grade duty ) weight of cover and frame to be not less than 23 kg.
Laying ,Jointing inlet, outlet, over flow and Scour pipe of GMS pipe of following internal dia ( medium grade)i/c extra carriage within all leads and lifts and as per the direction of the Engineer-in-Charge.
Inlet Gravity Main 80 mm.
Providing and Fixing Double Flanged Cast Iron Sliuce valve of Leader / Kirloskar make capable of withstanding the normal seat pressure and as per IS 14846 (Cast iron) with latest ammendments PN1.00 for following dia ( including brass spindle and as per IS 2906 class-II complete in all respect i/c carriage of material within all leads and lifts.
Out let pipe 80 mm ( Distribution )
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia.&180 mm deep (inside) with chained lid RCC top 1: 2: 4 mix (1 cement :2 Sand :4 graded stone aggregate 20 mm nominal size ) 100 mm thick foundation conc.1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1:3 (1 Cement : 3 Sand ) finished with a floating coat of neat cment i/c curing complete. 600 x 600 x 750 mm inside size With 150mm th.walls of RCC 1:2:4 (1cement : 2 sand :4 graded stone aggregate 20 mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways.
Finshing wall with water proofing cement paint of approved brand & manufacturer & of required shade on undecorated wall surfaces ( Two coats) to give an even shade after throughly brushing the surfaces to remove all dirt, dust and remain of loose powdered material. in all leads and lifts and as per the dirction of the Engineer- in - charge.
Provision for inlocking connection inlet/outlet,distribution system i/c cutting and welding ,Tee,bends various dia complete in all respect
Raj Kumar
SG Engineers and Consultants
Anil Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .