Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.7 L+₹4.3 L (12.1%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹41.9 L+₹6.5 L (18.5%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹42.3 L+₹6.9 L (19.5%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹42.6 L+₹7.2 L (20.2%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
9 Feb 2024, 6:00 pmClosed
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin - 305601
REPAIR/REPLACEMENT OF SUBMAIN WIRING AND EARTHING IN NASIRABAD MIL STN
2024_MES_638221_1
8415/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE Nasirabad
MES Contractor enlisted as Class D and above and category b i having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
Yes
GE NASIRABAD
₹90,000
Yes
22 Feb 2024
19 Jan 2024
12 Feb 2024
19 Jan 2024
9 Feb 2024
2 Feb 2024
19 Jan 2024 - 2 Feb 2024
Amount
Disconnecting of unserviceable sub main wiring of any size including conduit of any type and accessories & removing from site and making good the disturbed surfaces, complete all as specified and directed.
Disconnecting of unserviceable service connection of any size and removing from site and making good the disturbed surfaces, complete all as specified and directed.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid FRLS conduits with conduits accessories incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed. Make of wire- Paraflex/KEI/Havells Make of PVC conduit - Polycab/ Paraflex/Legrand-MDS Note : - Two run of single core cable, one run of earth continuity conductor and 1 mtr PVC conduit shall be measured as one unit length.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable complete all as specified and directed. Make of wire- Paraflex/KEI/Havells Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 10 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 10 Sqmm multi stranded copper conductor cable complete all as specified and directed. Make of wire- Paraflex/KEI/Havells Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 10 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid FR conduits with conduits accessories incl one run of green colour earth continuity conductor with 10 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed. Make of wire- Paraflex/KEI/Havells Make of PVC conduit - Polycab/ Paraflex/Legrand-MDS Note : - Two run of single core cable, one run of earth continuity conductor and 1 mtr PVC conduit shall be measured as one unit length.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 16 sqmm, complete all as specified and directed.
All as per item ser No 7.00 here-in-before but size 10 sqmm twin core
All as per item ser No 7.00 here-in-before but size 6 sqmm twin core
M & L for earthling complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh incl dismantling old unsv earthing complete all as specified and directed. Note:- The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level.
M & L for earthling complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to earth lead 32x6 mm galvanised iron strip dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth lead protection by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh incl dismantling old unsv earthing complete all as specified and directed. Note:- The unit rate includes for protection pipe and GI strip 32x6 mm from top of earth plate up to 7.5 meter above ground level.
S&F in repair house house service bracket hook type complete with 3 mtr long GI pipe 40 mm dia med grade ,two nos 90 degree bracket, MS hook and stay or guy etc, complete all as specified and directed
S&F GI lead wire 4.00 mm as earth continuity conductor beyond 7.5 mtr fixed to wall or burried in ground or drawn in pipe etc, complete all as specified and directed
S&F GI strip 32x6 mm as earth continuity conductor beyond 7.5 mtr fixed to wall or burried in ground or drawn in pipe, complete all as specified and directed
M/S MAMTA CONSTRUCTIONS
ENGINEER CORPORATION OF INDIA
M/s SUNIL ENTERPRISES
Nvimal Engineers and Contractor
KIRTIMAN ENTERPRISES
SHREE BALAJI TRADING CORPORATION
Anu Trading Co
KAVYA ENTERPRISES
M/S SHIVA TRADERS
PANKAJ ENTERPRISES
kirtiman traders
M/S JAGDISH PRASAD AIRUN
MITTAL ENTERPRISES
GOMA CONTRUCTION COMPANY
M/S Anil Enterprises
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .