| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.3 L+₹39,433 (1.01%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹39.4 L+₹43,393 (1.11%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹39.6 L+₹64,735 (1.66%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹39.9 L+₹96,429.43 (2.48%)Rejected-Finance 00 ITBAHRA GAUR KANIKAPUR ROAD KANIKAPUR BASTI UTTAR PRADESH 272163 | BASTI | UTTAR PRADESH | 272163 | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA Pin-151004
SPL REPAIR TO BLDG NO P-09/05 AND SPL REPAIR TO SEWAGE LINE AND SEPTIC TANK OF CERTAIN UNITS UNDER AGE B/R- V AND AGE E/M -V OF GE (N) BATHINDA AT BATHINDA MIL STN
2024_MES_645671_1
8938/NIT-85/23-24
Open Tender
Civil Works
Item Rate
180 days
BATHINDA
Class D Category a(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹90,000
Yes
3 Sept 2024
8 Mar 2024
13 May 2024
8 Mar 2024
11 May 2024
4 May 2024
8 Mar 2024 - 15 Mar 2024
Amount
B/R Works
Dismantling of Brick tiles terracing in single layer on roof laid and pointed in cement mortar and removing/ disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud from roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/ cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding / parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for roughening surfaces of existing concrete surfaces of roof by picking, sweeping, clean and washing down with water to remove dust etc and brushing with neat cement slurry @ 3.0 Kg of cement per sqm complete all as specified and directed by Engineer-in-charge. Note: The rate of neat cement slurry @ 3.0 Kg of cement per Sqm is included in this item and nothing shall be paid extra on this account.
Material and labour for cement concrete (1:2:4) type B-0, (using 12.50 mm graded stone aggregates) as in roof padding including mixing with water proof compound as per manufacturer's instructions and finished even and fair complete all as specified and as directed by Engineeer-in-charge. Note :- Water Proof Compound shall be measured and paid for separately as supply only under respective item of Schedule'A' BoQ.
Material and labour rendering 20mm thick screed bed in cement mortar 1:3 with WPC as per manufacturer's instructions on roof for roof treatment complete all as specified Note : WPC will be measured and paid seprately as supply only under respective item of BOQ
Material and labour for tack coat layer of blown grade bitumen of any penetration applied hot @ 1.70 Kg per Sqm and priming the surface @ 0.30 Kg per Sqm and with and including material and labour for laying 3mm thick APP based polymer membrane of weighing not less than 3.5 Kg per Sqm reinforced with polyster non woven fabric (weight not less than 150 Gm per Sqm) laid on primed surface at by torch application with side overlap 75mm and end overlap 100mm and tucked into the chasesas a treatment for moderate condition complete all as specified and as directed by the Engineer-in-Charge. Note: The rate of 3mm thick APP based polymer membrane is included in this item and nothing shall be paid extra on this account.
Supply only integral water proofing compound complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4) Type B0 (using 12.5mm graded stone aggregate) as in roof kerb (golla) or mud stops, side of roof sheet & similar work etc rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable bricks for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for rough cast plastering including 15 mm thick rendering in cement plaster 1 :4 complete as specified in SSR Part-I clause 14.22 as given in Note : Rough cast finish. After applying under coat of cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied complete including taking down cement plaster and applying two coats of cement based paint over a coat of primer all as specified and as directed by the Engineer-in-Charge.
Taking down cement or cement lime plaster from brick wall etc including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering appx 10mm thick (matching with existing plaster thickness) in cement mortar (1:3) on any face of ceiling, in patches, matching with existing, finished fair and even and smooth without using extra cement, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for plastering appx 15mm thick (matching with existing plaster thickness) in cement mortar (1:6) on old brick or concrete surfaces of walls/pillars /cornices, in patches, matching with existing, finished even and smooth without using extra cement, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for preparation of newly plastered or unplastered surfaces of ceiling and apply three coats of white wash on ceiling complete all as specified and as directed by Engineer-in- charge.
Material and labour for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash on ceiling, complete all as specified and as directed by Engineer-in- charge.
Material and labour for preparation of new plastered/ concrete surface of wall/ pillars/cornices by brooming down with using broom/sand papering or by other means, and preparing the surfaces smooth by applying 2mm thick wall care putty to make the surface smooth by using sander machine (with provision of dust sucking) upto entire satisfaction of Engr-in-Charge and applying two coats of plastic emulsion paint (with roller brush ) complete all as specified and as directed by Engineer-in-Charge.
Matterial and labour for complete removal of existing treatment (any layers of existing treatment) and efflorescence from Old decorated surface of wall/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-Charge brooming down and preparing the surfaces smooth and make good by applying 2mm thick wall care puty with white cement based and sanding the surface by mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engineer -in-Charge and after that appplying two coat of plastic emulsion paint (with roller brush only) complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of newly plastered/ concrete surface of wall/ pillars/cornices by brooming down with using broom/sand preparing or by tany other means, and preparing the surfaces smooth by appling one coat of primer and applying one coat of 2mm thick wall care putty to make the surface even and smooth by using sander machine (With provision of dust sucking) upto entire satisfaction of Engineer-in-Charge and applying two coats of acrylic smooth exterior emulsion paint, as approved tint/colour by using paint roller brush complete all as specified and directed by Engr-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment) effloresence from old decorated surface of wall/pillars/cormices by scraping down with using Mechanical sander machine( including provision of dust sucking) upto entire satisfaction of Engineer-in-Charge brooming down and preparing the surfaces and after that applying two coats of acrylic smooth exterior emulsion paint of approved tint/colour by using paint roller brush only complete all as specified and directed by Engr-in-Charge.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for 25 mm thick cement concrete (1:2:4), type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floor for leveling course, surface finished even & rough to recieve tile/ Kota stone/ PCC floor work complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (light shade) 10 mm thick, square or rectangular, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (light shade) 10mm thick square or rectangular (same as floor tile, as per above item ), as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (rendering) in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material and labour for non skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm/ 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Demolition of stone/marble slabs of any description or thickness as in floors/ cooking platform/steps etc. laid bedded and pointed in any mortar including removing rubbish material from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour 18-20mm thick machine cut, granite duly factory grinded and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, laid over and including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge.
Material and labour machine cut kota stone slab as in flooring 20-25mm thick, laid over and including cement screed base 20 mm thick in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
All as per item No 30.00 here-in-before but in dado/skirting/vertical surface including 15 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and above ground floors and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour 75mm cement concrete type (1:4:8) D 2, (using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engr-in-Charge.
Material and labour for machine pressed precast interlocking paver block 60 mm thick with grey cement and no pigment, factory made, any shape and size (as approved by GE), conforming to IS 15658-2006, made out of M-35 grade concrete laid over and including 25 mm thick layer of sand cushioning complete all as specified and as directed by Engineer-in- charge. Note: The rate of 25mm thick layer of sand cushioning is included in this item and nothing shall be paid extra on this account.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets fixed in any position with nails fixed with screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing GI powder coated frame work 605mm x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and duly suspended with 4mm GI wire hangers (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including laying 4mm thick designer decorative type asbestos cement ceiling board (E classic board) including two coats of acrylic emulsion paint over a coat primer specification and dirercted by Engineer-in-charge.
Material and labour for solid PVC wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification, includidng 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing mild steel cupboard shutter two leaves with frame of 20 gauges MS sheet (all around) and leaves of 21 gauge MS sheet (all as per Godrej Pettern) with three way locking arrangement with brass lock with CP handle with duplicate key including two coats of spray painting over a coat or red oxide primer complete fixed in existing cupboard fixed with necessary nuts bolts including embedded in PCC 1:2:4 (area's is opening shall be measured) complete all as specified.
Material and labour for 18 mm thick prelaminated MDF board , exterier grade (grade-1) confirming IS 14587, fixed with screws for kitchen cupboard and cabinet , self for cupboard including cut edges of prelaminated board to be sealed with 6mm teak lipping and all necessary fittings including dismantling of board of any description and type complete all as specified and directed.
Material and labour for 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screw to timber frame work/aluminium frame work including dismantling of board of any size and type complete all as specified.
Supply and fixing 30mm wide Continuous (piano) hinges, mild steel, bright finish or electrogalvanised fixing to wooden frame complete all as specified.
Supply and fixing 100mm long fancy type stainless steel handles, cast type, polished bright complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), wooden/PVC doors/steel ventilator area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 105 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately as supply only under appropriate item of BOQ.
Material and labour for PCC (1:3:6) type C-0 (using 12.5mm graded stone aggregate) as in back filling of chowkats and for hold fast complete all as specified and directed by Engr-in-Charge.
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge.
Supply & fixing for steel window box type double shutter ( glazed with wire gauge)with side hung shutters including hinges with steel handle and steel peg stay complete with glazing bar dovetailed or welded and including window guard bar, tower bolt,flat iron for fixing wire netting including one shop coat of zink chromate primer paint and making good to distrubed portion match with existing surfaces including taking out of existing steel window complete all as specified.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-Charge
Supply and fixed factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 100mm long mild steel butt hinges, medium weight, cold rolled complete all as specified & directed by Engineer-in-charge.
Supply only 100mm long mild steel butt hinges, medium weight, cold rolled complete all as specified & directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle, cast type 125mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle cast type 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing powder coated aluminium anodised frame (partition, door, ventilator, window) made out of aluminium section / aluminium chanel, powder coated (minimum thickness of powder coating not less than 50 micron), for doors, windows, ventilators, partition) with one or more rebate including jointing cleat for fixing etc. including taking down old unserviceable frame complete all as specified and as directed by Engineer-in-Charge. Note :- Weight of aluminium section/aluminium channel shall be physically ascertained through a board of officers convened by Accepting officer and payment shall be made only after the actual weight at site.
Supply & fixing anodised powder coated aluminium shutter for window/ ventilator/ door made out of aluminium section weighing 0.55 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron) including aluminium hardware i.e. necessary joining cleats, glazing clips, rubber neoprene packing, suitable size of aluminium handles 2 Nos and aluminium hinges 04 Nos in each leaf (size of handle and hinge as directed), anodised aluminium snap beading, screws etc including fixing of glass, inclcuding taking down old shutter complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium chowkhat frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ.
Supply & fixing 5.5mm thick tinted sheet glass ordinary quality/figured glass pin head in squares not exceeding 0.5sqm in each pane and fixed with oil putty etc. as required or as directed complete all as specified & directed by Engineer-in- charge.
Supply & fixing aluminium (extruded section) body door closer hydraulically regulated, designation No 3, universal type suitable for door shutter of 851 to 1000mm in width and weight between 61 to 80 Kg, ISI marked complete all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to wooden/ pressed steel frame with screw complete all as specified and directed by Engr-in-Charge
Supply & fixing in repair floor door stoper (150mm) of aluminium alloy body and tongue, anodised , with hard drawn steel spring fixed in floor complete all as specified and directed.
Supply & fixing stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including nut bolt and PCC work, including dismantling/taking down old pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) 'Y'/'T' junction (double/ single ), equal or unequal (any radius) suitable pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing plate rack stainless steel of size 750 mm x 900 mm made out of 1mm thick sheet with all necessary fittings, screws, bolts, and sufficient space for utensils complete all as specified and directed by Engineer-in-Charge.
Supply & fixing stainless steel sink made out of 1.00mm thick sheet, overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm, kitchen or laboratory with plugs, washers, waste pipe including bedding in cement mortar, fixing in existing space or fixing with cast iron cantilever brackets and connecting union to waste pipe, including taking down old unserviceable sink including fixing to granite/marble stone complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 20mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down existing pipe of any type complete all as specified and directed by Engr-n-Charge.
Supply and fixing 25mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down existing pipe of any type complete all as specified and directed by Engr-n-Charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and including supply and fixing 20mm ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge.
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement bib tap, long body, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge.
Supply and fixing in replacement stop valve/angle valve, cast copper alloy, chromium plated, fancy type, screwed down high pressure with crutch or butterfly handle, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge.
Supply and fixing concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge.
Supply & fixing chromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply and fixing CP grating doom 125mm dia with/without waste hole (min weight 40gms) complete all as specified and directed
Supply and fixing in replacement stainless steel chromium plated pipe 25mm dia, wall thickness of pipe not less than 20 guage, as curtain rod fixing with and including fancy type brackets and decorated end knobs (finials), stop roller etc, fixed on wall for doors and windows curtains, cuttings as required length and fixing at site including fixing arrangements, rawl plug, screws etc. including taking out old any type rod or pelmet boxes with curtain rod complete all as specified & directed by Engineer-in- charge.
Supply & fixing in repair vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm with integral foot rests (excluding flushing cistern, flush pipe above floor and trap), including demolition of tile, PCC, taking out old WC, taking out lime concrete filling and after fixing new WC re filling lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including fixing PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing before filling concrete and including all other connected work as required upto entire satisfaction of Engineer-in-charge complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type, low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 35mm thick precast cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in louvers and jallies/Jaffari (measured solid) including all moulding and MS wire but excluding frame and set in cement mortar (1:4) including necessary form work including taking down old broken/unserviceable jalli, complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundations, shafts, wells, cess pits, manholes, laying pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Description all as per serial item No 88.00 here-in-before but exceeding 1.5 metre and not exceeding 3.00 metre in depth. complete all as specified and as directed by Engineer-in-Charge .
Demolition and breaking up drain pipes SGSW, AC or reinforced concrete pipe up to and incl 150 mm bore pipes all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes SGSW, AC or reinforced concrete pipe up to and incl 250 mm bore pipes all as specified and directed by Engineer-in-Charge.
Material & labour for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipe incl packing under & haunching against the sides of pipe 150 mm dia (internal) after the pipes are laid and tested in trenches complete all as specified.
Material & labour for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipe incl packing under & haunching against the sides of pipe 250 mm dia (internal) after the pipes are laid and tested in trenches complete all as specified.
Material & labour for 150 mm dia (internal) reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches & jointed, complete all as specified and as directed by Engineer-in-Charge .
Material & labour for 250 mm dia (internal) reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches & jointed, complete all as specified and as directed by Engineer-in-Charge .
Material & labour for cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) for foundations, fillings & mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) but except bricks ( old serviceable bricks shall be used for incorporation in work after cleaning ) complete all as specified and as directed by Engineer-in- charge. Note :- The rate of cleaning of old bricks is included in this item and nothing shall be paid extra on this account.
Material & labour for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for manhole benching and coping complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading, leveling , watering & well ramming in layers not exceeding 25 cm thick each all as specified and as directed by Engineer-in-Charge.
Removal of excavated material to distance not exceeding 1.5 meter above the starting point complete all as specified and as directed by Engineer-in-Charge .
Material & labour in repair SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) size of cover 0.70 x 0.70 conforming to IS-12592, fixed in cement concrete 1:2:4. complete all as specified.
Cutting into existing manholes/ septic tank for connecting new drains upto 150 mm dia (internal), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed
Removing of manhole cover (CI or RCC) for opening of septic tank or sewage wells (any type rectangular or circular) of any size and capacity in foul condition and bailing out muddy water taking out semi solid sludge/solid contents/night soil from tank by mechanically by sewage suction pump making it fully functional and cleaning the internal surfaces with water the entire satisfaction of Engr-in-Charge incl all necessary tools and plants required for removal of all wastages, solid or liquid sludge from the site through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200m from the line/colony area where directed and covering the same with the soil obtined from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earth work and refixing the manhole cover to its original position complete all as specified and directed by Engr-in-Charge Note :- (i) All the tools and plants including mechanical pump, closed lorry and other allied arrangements for making septic tank clean and functional will be made available by the contractor without any extra cost to the Govt
E/M Works
Taking down old unsv copper/aluminium point/submain wiring concealed/ batten (light, fan, socket or power/submain) complete, including fixture and fittings such as switches, sockets, ceiling roses,bell push,bell electric,lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-charge.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through existing PVC conduit, independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including taking out old sub main wiring of any conductor any size from conduit and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire shall be measured as one RM length for payment.
Material and labour for concealed point wiring with 1.5 sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e pipe bend pipe hook, elbow, junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable lenth and 1.2mm thick), 3mm thick bakelite plastic laminated sheet for mounting switches and socket, fan regulator, for light/fan point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 1.5 sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc., including cutting chases in wall and making good distrubed surface of wall/ceiling/floors etc by using CM (1:3) to matching with existing surface complete all as specified and as directed by Engineer-in-charge. Note : (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
All as per item No 107.00 here-in-before but for multi 5 pin 5 Amp socket outlet on same board
All as per item No 107.00 here-in-before but for multi 5 pin socket outlet 5 Amp socket on independent board
All as per item No 107.00 here-in-before but for multi 6 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 sqmm copper conductor multistrand cable pvc insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25 mm dia and unsteathed copper conductor multistrand cable 1.5 sqmm as earth wire FRLS PVC insulated in green color all as directed by engr-in-charge.
Supply and fixing socket outlet 5 Pin, 5 Amp, flush type complete all as directed
Supply and fixing of angle/batten lamp holder on PVC square Blocks with PVC insulated body complete all as directed
Supply and fixing in replacement Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K Complete all as directed.
Supply and fixing for switch piano, flush type single pole one way 5 Amp, 240 volts all as specified.
Supply and fixing switch piano flush button single pole one way 15 Amp all as specified
Supply and fixing socket outlet 6 pin 15 Amp 240 volt multi purpose flush typeall as specified
Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet.
Supply and fixing in provision of BLDC (Brushless direct current motor) ceiling fan 5 star rated, complete with blades, down rods, and accessories, 230 Volts, 1200mm sweep, Min air delivery 210 CFM with service value 6.00 BEE, including electrical connection providing twin core round copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Ceiling fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account.
Supply and fixing for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 Volts double door complete all as directed by Engr-in-Charge.
Supply and fixing ceiling rose, 3 Phase/ PVC/ polycarbonate isolated body
Supply and fixing in replacement new generation energy saving ,wall mounted LED Tube light batten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED duly fitted on PVC square block 6500K (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz.
Supply and fixing MCB single pole and neutral 32 Amp suitable for 240 volt.
Supply and fixing MCB single pole and neutral 40-50 Amp suitable for 240 volt.
Supply and fixing MCB single pole 5-32 Amp suitable for 240 volt.
Supply and fixing in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed maganatic setting of cap 125 Amps 26 KA
Supply and fixing in replacement of Vertical TPN 4 way double door suitable for and including MCCB 125 Amp 26 KA four pole as incomer and out going MCBs and should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar all as specified and directed including taking down old UNSV DB/MCB any type.
Supply and fixing LED street light fitting 25/35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
Supply and fixing for LED Mirror light fitting of 9/10 watt, 6000 K , linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete with lamp and all other accessories fitting arrangement including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector all as specified and directed.
Material and labour for making holes for 300 mm dia exhaust fan of suitable shape & size into or through brick walls at Ground/ First/ Second floor including plastering for making good to the original surfaces of any description disturbed including painting /distemper matching with the existing colour. Note : Rates are deems to be including charges of any type of T&P, Insurance of staff deployed at site.
Material and labour for making holes for 450 mm dia exhaust fan of suitable shape & size into or through brick walls at Ground/ First/ Second floor including plastering for making good to the original surfaces of any description disturbed including painting /distemper matching with the existing colour. Note : Rates are deems to be including charges of any type of T&P, Insurance of staff deployed at site.
Supply and fixing of exhaust fan stainless steel body 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing of exhaust fan stainless steel body 450 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing of storage type water heater (Geyser) electrical operated 230/240 Volts 25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & including electric/earth connections complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of Gyeser and 'GE North BTD' shall also be writing on Gyeser with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Gyeser installed at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account.
Material and labour for fixing of 4 Nos rawl plug of suitable size (4"-6") nuts & bolts, grouting work in RCC/Brick wall, cemented works labour charges for cutting to exisiting GI pipe line of size 15 mm dia in position for insertion of tee or branch connection jointing complete with necessary GI fittngs, plumbing work all as per site requirement.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (Geyser Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 25 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for replacement of GI tubing medium grade, with all fittings laid in floor or trenches including taking out old UNSV pipe of size 15 mm dia complete all as specified and directed
Supply and fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed for 15 mm dia of pipe.
Supply & fixing 600 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply and fixing Bib tap cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe for brass ferrule of size 15 mm bore.
Material and labour for cutting to existing GI pipe of size 25/20 mm dia in position for addition/alteration or insertion of TEE for branch connection complete with cutting, threading and jointing/fixing including GI fitting as per site requirement
Supply, laying and testing cable XLPE Insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 70 Sqmm, 3.5 core in and incl taking out old one all as specified and directed.
Material and labour sand filling in cushing bed of cable and consolidation complete as specified
Supply and laying comman burnt clay building sub class `B' bricks, laid over sand Cushioning laid at right angle along with cable, all as specified and as directed.
Supply and laying GI tubing 40 mm bore, light graded incl all accessories for encasing cables for mechanical protection, laid under plinth/floors/path culverts with complete accessories such as bends/ sockets/ reducers/ saddles incl necessary threading/drilling works all as specified and directed of sizes (MS work will be measured under separate item in schedule)
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in earthing pit including necessary form work, excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR (Part – I) including taking out/dismantling old unserviceable earthing system complete all as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
V K CONTRACTOR
K L JINDAL AND CO.
M/s MITTAL CONSTRUCTIONS
M K Enterprises
R K GOYAL & COMPANY
Singla Enterprises
N.G BUILDERS
M/S VIAJY BUILDERS & DEVELOPERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .