Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.4 LAccepted-Finance | L-1 | Accepted-Finance Lowest | |
| 2 | L-2₹16.8 L+₹42,550 (2.60%)Rejected-Finance | L-2 | Rejected-Finance Highest | |
| 3 | L-3₹17.6 L+₹1.3 L (7.64%)Rejected-Finance HNO 365 STREET NO 12 TALAB TILLO JAMMU RISHI TRADING CO TALAB TILLO ROAD OPP FRIENDS LANE JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L-3 | Rejected-Finance Highest | |
| 4 | L-4₹19.7 L+₹3.3 L (20.3%)Rejected-Finance | L-4 | Rejected-Finance Highest | |
| 5 | Rejected-Technical NAGAR NIGAM GORAKHPUR UTTAR PRADESH | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | - | Rejected-Technical Technical Bid not Qualified |
Tender Value
₹21 L
EMD Value
₹21,000
Closing Date
26 Jul 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Office of the S.E. E.W.C. Shrirampuram Colony, Mohaddipur, Gorakhpur U.P.
Construction of 11 KV Underground Line and Increasing Capacity of Power T/f at 33/11 KV S/s Baitalpur for IOC Ltd Baitalpur Distt. Deoria.
2021_PVVNV_604079_1
01/EWC(G)/2021-22
Open Tender
Electrical Works
Item Rate
90 days
Baitalpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SE EWC Gorakhpur
₹21,000
5 Jan 2022
16 Jul 2021
27 Jul 2021
17 Jul 2021
26 Jul 2021
17 Jul 2021
90 days
Amount
Shifting & loading of following materials on private truck at store centre Deoria & carriage up to 33/11 KV Sub-Station Baitalpur , Distt- Deoria & Un-loading of the same with proper stacking.
ST Pole 11 mtr
ACSR DOG Conducter
11 KV 'XLPE' Cable 3x185mm²
11 KV ‘XLPE’ power cable.3x300 mm2
33 KV ‘VCB’ complete with all structure.
33 KV Isolator
33 KV control Pannel
33 KV Post Insulator
33 KV Lightening arrester
33 KV Small structure( Bus isolater structure,post insulator structure, fuse set structure.CT Structure, LA Structure)
11 KV Switchgear panels
11 KV Pole Mounted CT/PT Unit.CTR 100/5
11 KV Pilfer resistant Metering Cubicle without cable Termination kit
Electronic TVM for 11 KV.
Erection of Double pole structure on 11 mtr ST Pole for one side overhead line and one site underground line including all works of evocation of pit, pole erection,proper ramming & fitting of all accessories (M.S. angle iron 65 x 65 x 6 mm bracing with clamps, top channel 100 x 50 x 2240 mm with clamps, earthing, etc. complete).
Making plinth for ST poles 11 mtr. 30 cm above , grouting in the ratio 1:4:8 (cement, sand, 40mm brick ballast),back filling of earth etc. complete). As per required specification of UPPCL RESSPO Norms.
Painting of ST Poles with two coats of Alluminium paint and red oxide paint As per required specification of UPPCL RESSPO Norms.
Fixing of barbed wire on ST Pole as per proper specification.
Fixing of danger board on ST Pole as per proper specification.
Numbering of S.T. Pole 11 mtr. Long.
Grouting of stay rods (16 x 1800) mm including all work of excavation, cement concrete in size (0.60 x 0.60 x 0.30) m in ratio 1:4:8 cement, sand, 40mm brick ballast) as per drg including back filling, proper ramming etc. Fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing
Laying of 11 KV 3x185 mm² ‘XLPE’ cable 1260mtrs length x 2 =2520 mtrs (Double Circuit) by digging pit & making trench in Proper size(1.2 M depth x1M wide) below ground level by fixing bricks(4½˝)on both side of trench wall and 9˝ brick work at the centre of the trench along the cable.Fixing brick slab on top after filling sand around both the cable including cost of bricks as per required specification of UPPCL RESSPO Norms.
Installation of 11 KV Pilfer resistant Metering Cubicle etc. Complete work
Installation of 11KV Electronic TVM and CT/ PT Unit.
Providing & Laying of 11 KV 3x185 mm² ‘XLPE’ cable 100 mtrs length x 2 =200 mtrs (Double Circuit) by HDD Method with HDPE pipe.
Laying of 11KV ‘XLPE’ cable in air after providing 6” dia. GI pipe (B.class) 3 m long with Complete work.(1475/mtr).
Providing & Jointing charges of 11 KV “XLPE” C/J kit 3 x 300/185 mm2 indoor/Outdoor type
GI Pipe Earthing Comp.with materials.
Providing 11 KV Cable Route Marker & inserting in ground with proper grouting (Provided by Contractor & Cable Route Marker is made by stone Plate) .
Repairing of power transformer plinth for 5 MVA transformer of size 3.5 x 3.5 x 1.5 mtr. including cost of all material as per drawing.
Installation of New 5 MVA T/F about 35 mtrs distance & placing on T/F plinth.Erection of conservator tank, radiators & filling of T/F oil, jumpering etc. complete work.
Earthing of 5 MVA power transformer body earthing at two places including cost of G.I. strip, G.I. pipe and other earthing materials required.
Neutral earthing of 5 MVA transformer complete including cost of G.I. strip, G.I. pipe 1.5” dia 30’ long and other earthing materials.
Grouting of M.S. Channel 3.2 mtr. long for neutral earthing support of 5 MVA transformer with help of G.I. strip 50 x 6 mm and copper flexible bond etc.
Grouting of M.S. channel 3.2 mtr long (2 Nos.) for cable stand and welding of M.S. flat (3 Nos.) at equal distance for fastening cable by clamp with nuts and bolts mounting of cable at cable stand and connection of jumpers.
Installation of 33 KV control panel for “VCB” with complete earthing with installation of battery and battery charger in control room and making connection.
Laying of 11 KV “XLPE” power cable 3 x 300 mm2 / 185 mm2 including digging of pits of size 0.5 x 0.5 mtr. covering of cable with sand and 1st class brick around the cable.
Shifting of 11 KV switchgear to control room and placing in control room with grouting of bolts and mounting of switchgear panels properly.
Electrical connection of 11 KV switchgear panel and fitting of Bus Bar and P.T.
Testing of 11 KV switchgear panel in all respect.
Providing following control cable and its laying from switchyard to control room 33 KV panel by digging trench in switchyard including cost of sand and 1st class bricks with covering and making connection complete and including cost of laying.
Separate earthing of 1 Nos. 11 KV switchgear with help of 4 Nos. G.I. pipe 3 Mtr. long will be penetrate in earth duly interconnected at the distance of 3 Mtr. each as per RESSPO drawing No. RES-40 at both end of cable trench and G.I. strip 50 x 6 mm with clamping from earthmat to switchgear complete including cost of materials.
Providing and Making connection of 24 Volt battery and battery charger with cabinet.
Erection and grouting of “VCB” and C.T. structure, mounting and fitting of VCB and CT on erected structure with complete fitting and earthing of structure. Insallation of battery and battery charger in control room.
Erection and grouting of following structure.
33 KV Bus Isolator structure
33 KV fuse set structure
33 KV Post insulator structure
33 KV L.A. structure
Erection and grouting of following Equipments on erected structure
33 KV Bus Isolator
33 KV fuse set ( Providing Copper strip as required size for 33 KV fuse set)
33 KV Post insulator
Earthing of outdoor type switchyard for newly erected structure as per proper specification with GI Earthing strip.
Jumpering from 33 KV Bus bar to post insulator, bus isolator, VCB, CT and LA to 5 MVA transformer etc.( Providing alluminium Lug and PG Clamp)
Construction of approach road inside the switchyard 1.5 Mtr. wide with 1st class bricks on edge soling and tipping complete work including cost of all materials.
Painting of newly erected structure in switchyard (Applying on coat of good quality red oxide primer then two coat of good quality of high class luxol aluminium paint)
M/S GORAKHPUR ENTERPRISES
Rishi Trading Co.
INDIA SUPPY CORPORATION
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .