Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.4 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹32.1 L+₹35,800 (1.13%)Rejected-AOC S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹32.3 L+₹50,633 (1.59%)Rejected-AOC 6 341 RATAN VIHAR NANGLOI DELHI 110041 | DELHI | WEST DELHI | DELHI | 110041 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹37.5 L+₹5.8 L (18.2%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L-4 | Rejected-AOC L-4 | |
| 5 | L-5₹39.8 L+₹8.1 L (25.4%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L-5 | Rejected-AOC L-5 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
26 Feb 2022, 6:00 pmClosed
GE I RND Delhi
MILITARY ENGINEER SERVICES, GE I RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINTENANCE OF DG SETS, AMF PANEL AND OTHER CONNECTED WORKS IN METCALFE HOUSE AND JCB LAB UNDER GE I RND DELHI
2021_MES_493128_1
GE/RnD-83/DLI/2021-2022
Open Tender
Civil Works
Item Rate
270 days
Delhi
Class-D, Cat-b(i)
2 documents required · 2 mandatory
₹500
GE I RND Delhi
₹98,000
Yes
26 Mar 2022
7 Dec 2021
28 Feb 2022
7 Dec 2021
26 Feb 2022
14 Feb 2022
Amount
M&L for B check general servicing by authorised rep of manufacturer of DG set of capacity 20 to 30 KVA, replacement of oil filter, fuel filter, air filter, by pass filter cleaning of radiator with chemical after draining out engine/ lubrication oil, coolant flushing and cleaning of oil chamber after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment refixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof sollution, oil pan/ chamber gasket at the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer all as specified and directed. Note-Engine oil & Coolant will be paid separately under respective item.
All as per Ser item No 1 but of capacity 100 to 180 KVA
All as per Ser item No 1 but of capacity 200 to 300 KVA
All as per Ser item No 1 but of capacity 380KVA
All as per Ser item No 1 but of capacity 750 KVA
M&L for repair of self starter 12 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 20 KVA to 30 KVA complete all as specified and directed.
M&L for repair of self starter 24 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 100KVA to 180 KVA complete all as specified and directed.
All as per Ser item No 7 but of capacity 200 to 300 KVA
All as per Ser item No 7 but of capacity 380 KVA to 750 KVA
Supply & Fixing in replacement of automatic battery charger with auto cut OFF suitable for charging of 2X12V 180AH batteries with all required necessary wiring complete all as specified and directed.
Supply & Fixing in replacement of automatic battery charger with auto cut OFF suitable for charging of 4X12V 180AH batteries with all required necessary wiring complete all as specified and directed.
M&L for replacement of wiring complete to AMF panel for capacity upto 300 KVA of DG set including interlock system of AMF panel with existing size of copper wiring including proper connection and testing of DG Set complete all as specified and directed.
M&L for replacement of wiring complete to AMF panel for capacity upto 380 KVA of DG set including interlock system of AMF panel with existing size of copper wiring including proper connection and testing of DG Set complete all as specified and directed.
M&L for replacement of wiring complete to AMF panel for capacity upto 750 KVA of DG set including interlock system of AMF panel with existing size of copper wiring including proper connection and testing of DG Set complete all as specified and directed.
Supply and Fixing in replacement of self starter 24 volts suitable for upto 125 KVA DG sets complete all as specified and directed.
Supply and Fixing in replacement of self starter 24 volts suitable for upto 180 KVA DG sets complete all as specified and directed.
Supply and Fixing in replacement of self starter 24 volts suitable for upto 200 KVA DG sets complete all as specified and directed.
Supply and Fixing in replacement of self starter 24 volts suitable for upto 250/ 300 KVA DG sets complete all as specified and directed.
Supply and Fixing in replacement of self starter 24 volts suitable for upto 380 KVA DG sets complete all as specified and directed.
Supply and Fixing in replacement of self starter 24 volts suitable for upto 750 KVA DG sets complete all as specified and directed.
Supply & Fixing in replacement of power contactor 630 Amps capacity suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
Supply &Fixing in replacement of power contactor 400 Amps capacity suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
Supply & Fixing in replacement of power contactor 200 Amps capacity suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
Supply & Fixing in replacement of power contactor 125 Amps capacity suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
Supply and Fixing in replacement of battery brass terminals heavy duty suitable for 12V 180 AH battery with minimum 3 RM Battery Lead of copper multistranded single core complete all as specified and directed.
Supply and Fixing in replacement of relay 24 V 8 pin type as per matching to existing complete all as specified and directed.
Supply and Fixing in replacement of engine starting relay suitable for DG set of capacity 20 KVA to 30 KVA as per matching to existing complete all as specified and directed.
Supply and Fixing in replacement of engine starting relay suitable for DG set of capacity 100 KVA to 180 KVA as per matching to existing complete all as specified and directed.
Supply and Fixing in replacement of engine starting relay suitable for DG set of capacity 200 to 300 KVA as per matching to existing complete all as specified and directed.
Supply and Fixing in replacement of engine starting relay suitable for DG set of capacity 380 KVA as per matching to existing complete all as specified and directed.
Supply and Fixing in replacement of engine starting relay suitable for DG set of capacity 750 KVA as per matching to existing complete all as specified and directed.
Supply and Fixing in replacement of Electronic timer suitable for AMF panel of DG set as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
Supply & Fixing in replcement of Voltmeter analog type for voltage range of (0-24V) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
Supply & Fixing in replacement of Voltmeter analog type for voltage range of (0-500V) complete with all accessories and wiring complete all as specified and directed.
Supply & Fixing in replacement of Ammeter analog type for current range of (0-24Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
Supply & Fixing in replcement of Ammeter analog type for current range of (0-1000Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
Supply & Fixing in replacement of power contactor ML 6 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
Supply & Fixing in replacement of power contactor ML 4 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
Supply & Fixing in replacement of power contactor ML 3 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
Supply and Fixing in replacement of under voltage relay suitable for DG set complete all as specified and directed.
Supply and Fixing in replacement of complete wiring with single core 2.5 Sqmm multistranded copper conductor cable with flexible conduit 15 mm dia for DG set of various capacities complete all as specified and directed.
M&L in repairs earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to copper strip 20x3mm as earth lead a by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI mesh charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 40mm dia from earth pit to main board & testing on completion :- (a) Copper strip 20x3mm (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm in plaster thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor passing through PVC Conduit of size 25 mm as main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 20x3mm Copper strip complete all as specified and directed.
M&L in repairs Earthing complete with galvanised earth plate electrode of size 600 x 600 x 6mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to GI earth strip 25 x 4mm as earth strip by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI mesh charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 40mm dia from earth pit to main board & testing & on completion:- (a) GI earth strip 25x4mm (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick in plaster cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor passing through PVC Conduit of size 25 mm main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed.
S & F and testing Electronic Governor Controller for capacity 100 to 180 KVA DG Set including taking down old Governor Controller complete all as specified and directed.
S & F and testing Electronic Governor Controller for capacity 200 KVA DG Set including taking down old Governor Controller complete all as specified and directed.
Taking down the old unserviceable actuator from its position and S&F new actuator for 250/ 300 KVA DG Set complete all as specified and directed.
Taking down the old unserviceable actuator from its position and S&F new actuator for 380 KVA DG Set complete all as specified and directed.
Taking down the old unserviceable actuator from its position and S&F new actuator for 750 KVA DG Set complete all as specified and directed.
Opening the DG set of 200 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line , belts & Bearings including re-assembling the complete Parts and Testing complete all as specified and directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
S&F Piston ring and liner for 200 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 200 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 200 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Packing Kit for 200 KVA DG Set as per existing make & OEM complete all as specified and directed.
M&L for repair of Head and fuel injector assembly complete for 200 KVA complete all as specified and directed.
M& L for repair of Turbo assembly complete for 200 KVA complete all as specified and directed.
Opening the DG set of 250 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line , belts & Bearings including re-assembling the complete Parts and Testing complete all as specified and directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
S&F Piston ring and liner for 250 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 250KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 250 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Packing Kit for 250 KVA DG Set as per existing make & OEM complete all as specified and directed.
M&L for repair of Head and fuel injector assembly complete for 250 KVA complete all as specified and directed.
M&L for repair of Turbo assembly complete for 250 KVA complete all as specified and directed.
Opening the DG set of 380 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line , belts & Bearings including re-assembling the complete Parts and Testing complete all as specified and as directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
S&F Piston ring and liner for 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Packing Kit for 380 KVA DG Set as per existing make & OEM complete all as specified and directed.
M&L for repair of Head and fuel injector assembly complete for 380 KVA complete all as specified and directed.
M& L for repair of Turbo assembly complete for 380 KVA complete all as specified and directed.
Opening the DG set of 750 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing all flexible/steel wire mesh type hose pipes including fuel pipe line , belts & Bearings including re-assembling the complete Parts and Testing complete all as specified and as directed. Note :- Spare parts required for replacement shall be measured & paid under following item.
S&F Piston ring and liner for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Head valve, Head Guide, Head sheet & Head seal for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Injector sleeves & Head gasket for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
Supply only Packing Kit for 750 KVA DG Set as per existing make & OEM complete all as specified and directed.
M&L for repair of Head and fuel injector assembly complete for 750 KVA complete all as specified and directed.
M& L for repair of Turbo assembly complete for 750 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 20 to 30 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 100 to 180 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 200 to 300 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 380 KVA complete all as specified and directed.
Taking down the old unserviceable fan belt and Supply and Fix Fan belt of existing size for DG Set of capacity 750 KVA complete all as specified and directed.
Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold for DG sets 20 to 30 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
All as per Ser item No 61 but of capacity 100 to 180 KVA
All as per Ser item No 61 but of capacity 200 to 300 KVA
All as per Ser item No 61 but of capacity 380 KVA
All as per Ser item No 61 but of capacity 750 KVA
S&F in replacement fly wheel ring of DG Set of capacity 125 KVA complete all as specified and directed
S&F in replacement fly wheel ring of DG Set of capacity 180 KVA complete all as specified and directed
S&F in replacement fly wheel ring of DG Set of capacity 200 KVA complete all as specified and directed
S&F in replacement fly wheel ring of DG Set of capacity 250/300KVA complete all as specified and directed
S&F in replacement fly wheel ring of DG Set of capacity 380 KVA complete all as specified and directed
S&F in replacement fly wheel ring of DG Set of capacity 750 KVA complete all as specified and directed
Draining out the diesel tank & kept at site for refilling, cleaning/washing out the sludge and re-filling the drain out old diesel for the DG Set of capacity 20 to 30 KVA complete all as specified and directed
All as per item No 72 but for the DG Set of capacity 100 to 180 KVA.
All as per item No 72 but for the DG Set of capacity 200 to 300 KVA.
All as per item No 72 but for the DG Set of capacity 380KVA.
All as per item ser No 72 but for the DG Set of capacity 750KVA.
M&L for Repair to radiator of 20 to 30 KVA DG set ,arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- Necessary coolant and distilled water required will be measured and paid seperately.
All as per Ser item No 77 but of capacity 100 to 180 KVA
All as per Ser item No 77 but of capacity 200 to 300 KVA
All as per Ser item No 77 but of capacity 380KVA
All as per Ser item No 77 but of capacity 750KVA
Removing old unserviceable insulating material asbestos rope and fixing of new of existing size and shape complete all as directed
M&L for Spray painting of diesel generating set of capacity 20 to 30 KVA. with one coat of synthetic enamel paint , body colour shall be apple green,black for foundation base frame, red for all guards including preparing old surfaces complete all as specified and directed.
All as per item No 83 above but of capacity 100 KVA to 180KVA.
All as per item No 83 above but of capacity 200KVA TO 300 KVA.
All as per item No 83 above but of capacity 380KVA with accostic enclosure.
All as per item No 83 above but of capacity 750KVA.
Taking Down the AVR system and supply and fix new AVR system for DG set of capacity 100 TO 180 KVA complete all as specified and directed
All as per item No 88 above but of capacity 200 KVA to 300 KVA.
All as per item No 88 above but of capacity 380KVA.
All as per item No 88 above but 750KVA .
Replacement of turbo chargers repairs kit suitable for DG set 100 KVA. to 180KVA complete all as specified and directed
All as per item No 92 above but 200 KVA to 300 KVA
All as per item No 92 above but 380KVA.
All as per item No 92 above but 750 KVA
S&F in replacement of 3 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, fixed type complete all as specified and directed
S&F in replacement of 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, fixed type complete all as specified and directed
S&F in replacement of 3 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA, fixed type complete all as specified and directed
S&F in replacement of 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, fixed type complete all as specified and directed
S&F in replacement of 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, fixed type complete all as specified and directed
S&F in replacement of 4 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA, fixed type complete all as specified and directed
Supply only Engine oil 20W/40 for DG Set.
Supply only Engine oil 15/40 for DG Set.
Supply only Coolant for DG Set.
Supply only Cotton Cloth for cleaning of DG Set.
Supply & fixing of automatic sequencer including software of make Delta for 250 KVA DG Set with complete wiring and testing as directed by Engr-in-charge.
M&L for repair to alternator of DG Set of capacity 20KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc. cpmplete all as aspecified and as directed.
M&L for repair to alternator of DG Set of capacity 180KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc. cpmplete all as aspecified and as directed.
M&L for repair to alternator of DG Set of capacity 300KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc. cpmplete all as aspecified and as directed.
M & L for Servicing to AMF panel of any size/make check all loose connection of end terminal, screw, Nut Bolts, thimble. Clean all electric / electronic parts by using CRC spray, checked contactor connections and its serviciebility , check all realy setting of AMF Panel and check all internal connections of AMF Panel.incl hinges and locking devices complete all as directed by Engr-in-Charge.
Supply and laying in replacement of old unserviceable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
Supply and laying in replacement of old unserviceable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 240 Sqmm 3.5 core complete all as specified and directed.
Supply and laying in replacement of old unserviceable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 300 Sqmm 3.5 core complete all as specified and directed.
Supply and laying in replacement of old unserviceable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 400 Sqmm 3.5 core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for protection of cable duct including for taking out and relaying of LT Cables etc complete all as specified and as directed.
Excavation in trenches in hard/dense soil not exceeding 1.5m depth not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables in hard standing surfaces ,Road cutting etc complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed Note:- Punned thickness shall be measured.
M&L for sub class 'B' burnt brick flat across the cable, for protection of cable laid in trenches complete all as specified and directed
M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique and necessary machine including supply and laying of DI pipe of 100 mm dia complete all as specified and directed by Enginer-in-Charge
Supply and laying in replacement of old unserviceable of GI pipe medium grade 100mm dia laid in trenches for protection of UG cable complete all as specified and directed
Supply and laying in replacement of old unserviceable of GI pipe medium grade 50mm dia laid in trenches for protection of UG cable complete all as specified and directed
Supply and laying in replacement of old unserviceable of GI pipe medium grade 40mm dia laid in trenches for protection of UG cable complete all as specified and directed
M&L for PCC 1:2:4 typeB-1using 20 mm graded stone aggregates for repairing of panel foundation etc including filling in road cuts/ hard standing etc complete all as specified and as directed.
Supply and fix in replacement old unserviceable Battery 12 Volt 180 AH for JCB DG set and SAG complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix earth pit chamber alongwith cover of Polymer, FRP Pit Cover of heavy high grade polypropelene for high stress and starin level of size 225x300x 195 mm complete all as specified and directed.
S&F ACP retro sign board of size 1.5 x 1.1 Mtr using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the DG Set subtation Details, and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners , nuts, bolts, washer etc complete all as directed by Engineer-in-Charge at site.
Charan sales and Service
M/s Wazer Enterprises
Rahul Enterprises
PARADISE INFRA POWER COMPANY
Surjit and Sons
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .