Loading…
Loading…
Tender Value
₹2.9 Cr
EMD Value
₹5.8 L
Closing Date
3 Oct 2026, 12:30 pmDue tomorrow
Chief Manager Works
Proposed Construction of Security office Building G 1F including Civil and Electrical works at ACD Division Doddanekkundi Road HAL Bangalore
TENDER NOTICE/NCP/54/26-27::HAL/FMD/C-53/26-27
TENDER NOTICE/NCP/54/26-27
Open Tender
Works
10MONTHS
Contract Section Civil-FMD-Bangalore
Refer Tender Document
₹0
₹5.8 L
14 Aug 2026
14 Aug 2026
3 Oct 2026
3 Oct 2026
28 Aug 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Year of Estblishment of Company/Business
If Other, please specify
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc.,
Address for correspondence:
PAN no and Name of Holder
PF number (If any)
ESI number
Goods and Service Tax ID No.
Contact details
Registered Contractor
Pls Enter
I.T Returns for past 03 assessment years
Turnover during the following 5 years (In Rs. Lakhs)
Pls enter Finiancial Turnover in Rupees Lakhs for all the years
DETAIL OF WORK ON HAND UPTO N-Months (N-contract period) [For Bid capacity calculation] NOTE : CA certified statement as per below format to be uploaded.
Name of Organization with address
Work Schedule for completion of works with in stipulated time [Please enclose action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)]
Bank(s) details: [Copy of ECS and cancelled cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Bank Statement for past three month
Latest Overdraft Facilties with Bank enter Name of Bank, Date of Issue and Value of Over Draft
Solvency Certificate Details
Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender. [Work experience certificates / Completion certificates should be uploaded for verification]. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost. [Amount put to the Tender]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work and Organisation name [ Incase of private works the same shall be supported with TDS certificate]
Related Document to be Uploaded to eProcurement Portal
DEAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficant separate sheet to be uploaded with the same format as below)
Name of members or technical personllel avalable in the organization
DETAILS OF MACHINERY AVAILABLE
Name of Mechinery
Concrete Mixers - Type etc
Vibrators - Diesel - Electrical
Weiding equipment's
a) Rectifiers
b) Welding Generators
Erection equipment's
Cranes-
Hoists-
Lifts-
Water Lifting motor pumps
a) Diesel
b) electric
Drilling Equipment's
Compressors
Trucks
Stone crushers
Bitumen hot mixture plant
Bitume boiler
Rollers
Batching plants
Vibratory rollers
Generators
Cranes-Details
Concrete pumps
Road Pavers
Rock breakers
Transit mixers
Excavators
Weight batches
Others
DECLARATION
Pls enter
EMD details
Enclosed / Not enclosed
Enclosed
Average annual financial turn over during the last 3 years, ending 31st March 2025 and details for last 5 years to be provided to assess the bid capacity. The values provided to be supported by uploading Balance Sheet along with Profit & loss account (In Rs. Lakhs)
Specification
Demolishing R.C.C. work by mechanical means and stock piling at designated locations and disposal of dismantled materials up to a lead of 10 kilometre outside HAL, stacking serviceable and unserviceable material separately including cutting reinforcement bars,after making temporary proetction for existing service lines etc., all complete as directed by the Engineer-in-Charge.
Demolishing brick work with cement mortar manually/ by mechanical means, after disconnecting the electrical service and AC lines if any, including stacking of serviceable material and disposal of dismantled materials up to a lead of 10 kilometre outside HAL etc., all complete as directed by the Engineer-in-Charge.
Demolishing Nominal concrete 1:4:8 or richer mix (i/c equivalent design mix) manually/ by mechanical means including disposal of material within 50metres lead and including stacking material and disposal of dismantled materials up to a lead of 10 kilometre outside HAL,after making temporary proetction for existing service lines etc., all complete as directed by the Engineer-in-Charge.
Dismantling doors, windows/ventilators and clerestory windows (steel or wood) shutter including chowkhats,steel frames,grills , glass,architrave, holdfasts andother fixtures etc. complete and stacking within 50 metres lead of area 3 sq. metres and below, including stacking material and handing over the useful materials to HAL maintenance department and disconnecting the service lines if any etc., all complete as directed by the Engineer-in-Charge.
Dismantling/removing Vitrifed/mosaic tiles,granite,PVC sheets (upto 40mm tile thickness.) in floors and walls laid on cement mortar ,after disconnecting the electrical service and AC lines if any,including stacking material and disposal of dismantled materials up to a lead of 10 kilometre outside HAL etc., all complete as directed by the Engineer-in-Charge.
Dismantling C.I./asbestos/PVC rain water pipe with fittings and clamps including stacking the material within 50 metres lead and handing over the useful materails to user department etc., all complete as directed by the Engineer-in-Charge.
upto 100 mm dia
Above 110mm to 150 mm dia
Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead and handing over the usefull materials to user department etc., all complete as directed by the Engineer-in-Charge.
Demolishing brick bat waterproofing /mud phaska in terrace and disposal of waste material upto a distance of 10Km including all lead and lift with required labour using mechanical transport system and preparing the terrace surface to lay the Tiles/new water proofing materails etc., all complete as directed by the Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas in all kinds of soft / hard soil for foundations, footings, column pedestals or members as per the drawing and site requirement etc., (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50 m and in all lifts with all labour, tools & tackles, plant & machinery, hire & fuel charges etc., all complete as directed by Engineer-incharge.
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains, pipes, cables etc. in all kinds of soils (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lifts, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m with all labour, tools & tackles, plant & machinery, hire & fuel charges,dewatering if any etc., all complete as directed by Engineer-incharge.
Returning / filling in with useful excavated soil (excluding rock), free from salts, organic or other deleterious matter (Other than black cotton soil & rock etc., in trenches, plinth,sides of foundations etc., spreading in layers not exceeding 20 cm thick, watering, breaking / removing clods exceeding 50 mm, ramming and consolidation of each deposited layer etc., with all labour, tools & tackles, plant & machinery, etc., lead upto 50 m and for all lifts etc., all complete as directed by Engineer-incharge.
Removing / transporting the surplus excavated earth including debris, vegetation waste, concrete waste, etc., to a distance upto 5000m from HAL premises to contractor's own yard including loading, unloading, depositing, spreading, levelling etc, all complete as per directions of Engineer-in-charge.
Construction of granular sub-base (G.S.B) With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications etc., all complete as directed by Engineer-incharge.
Supplying chemical emulsion( Chlorpyriphos/ Lindane or any other equivalent make emulsifiable concentrate of 20%) in sealed containers including delivery as specified etc., all complete as directed by Engineer-incharge.
Diluting and injecting chemical emulsion with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc., all complete as directed by Engineer-incharge. Note:The activity to be carried out through specialised agency who has registred under NCPI and who has executed similar services for IndustriaL Building Area.
Diluting and injecting chemical emulsion with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre includ ing drilling and plugging holes etc., all complete as directed by Engineer-incharge. Note:The activity to be carried out trhough specialised agency who has registred under NCPI and who has executed similar services for IndustriaL Building Area.
Supplying, mixing and placing plain cement concrete (1:3:6) of required thickness using 20mm down graded hard stone/granite aggregate in accordance with IS 456 in foundations, mass concrete, sub bases and other similar works excluding formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing etc., all complete as directed by Engineer-incharge.
Supplying, mixing and placing plain cement concrete (1:2:4) of required thickness using 20 mm down graded hard stone/granite aggregate in accordance with IS 456 in Floor leveling/ lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor,plinth etc excluding formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing etc., all complete as directed by Engineer-incharge.
Centering and shuttering or PCC,Bands,Coping,Counters works including strutting, propping etc. and removal of form work for for Foundations, footings, bases for columns etc., all complete as directed by Engineer-incharge.
Providing and laying in position ready mixed or site batched design mix Cement Concrete of M25 grade with minimum cement content of 330 kg /cum for reinforced cement concrete work like,footing,pedestal,columns,beams,lintles,chajjas/canopies,staircases,sills,fins,shelves,flooring,stage etc.; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads etc., all complete as directed by Engineer-incharge. Note 1.Form work and reinforcement steel will be paid separately.
All works upto plinth level like footing,pedetsal,piles,plinth beam,drains,including necessary openings and packing if any for laying pipes, cables etc.
All works above plinth level like column,beams,slabs,canopy,chajja,staircase etc. level including necessary openings and packing if any for laying pipes, cables etc.
Formwork for Lintel Beams, window sills etc., by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete etc as per drawing., all complete as directed by the Engineer-in-Charge Note :Formwork material is contractor's own property and shall be removed after completion of work.
Foundations, footings, bases of columns,for mass concrete etc.
For Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Shuttering for Staircase excluding Landing
Supplying, straightening, fabricating and fixing Steel reinforcement of HYSD TMT bars of not less than Fe 500 conforming to IS 1786 for all concrete reinforcment members / works including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.9 mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it etc., complete all as per specifications, drawings etc., all complete as directed by Engineer-incharge. Note :1. For measurement, the weight of steel sections, plates, reinforcement steel bars, wire fabrics etc., shall be calculated from the tables given in relevant Indian standards or actual whichever is less. Where the weight is not given in Indian standards, it shall be calculated at 7850 kg/m³. No tolerance on account of rolling margin shall be allowed on the nominal weight of steel sectionsetc., all complete as directed by Engineer-incharge.
Providing and fixing Stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge, (for payment purpose only weight of stainless steel members shall be considered etc., all complete as directed by Engineer-incharge.
Providing and fixing M.S. grills with mesh of required pattern to steel windows/ walls/ in frames of windows,ventilators,e.t.c and approved design using MS structurals such as M.S flats, angles, round/square bars etc., including necessary cutting, welding, embedding in concrete, masonry etc.,including priming coat with approved steel primer etc., all complete as directed by Engineer-incharge.
Providing and fixing of Steel work in built up using Hot finished seamless type tubes (round, square or rectangular hollow tubes trusses etc , including cutting, hoisting, fixing in position and applying a priming coat and two coats of enamel paint for structural steel surface of approved make, including welding and bolted with special shaped washers etc., all complete as directed by Engineer-incharge.
Providing and laying masonry with factory made Precast concrete solid blocks of 200mm thickness of grade M10 made of Normal/C&D waste from approved manufacturer in superstructure above plinth level up fifth floor level (As per Industrail buildng floor heights) with Cement mortar (1:6) including required stagging,each course in true level & racking out joints,curing and cleaning etc., all complete as directed by Engineer-incharge.
Providing and laying half block masonry with factory made Precast concrete solid blocks of 100mm thickness of grade M10 made of Normal/C&D waste from approved manufacturer in superstructure above plinth level up to +10m height with Cement mortar (1:4) including required stagging,each course in true level & racking out joints,curing and cleaning etc., all complete as directed by Engineer-incharge.
Plastering to ceiling with 12 mm thick on the rough side with cemnet mortor (1:4) including leveling,curing and making the level smooth and at all heights and execute the work etc., all complete as directed by Engineer-incharge.
Plastering to internal brick/block wall with 15 mm thick on the rough side of single or half brick wall of cemnet mortor (1:6) including leveling,curing and making the level smooth and at all heights, plaster drip course/ groove in plastered surface or moulding to R.C.C. projections and execute the work etc., all complete as directed by Engineer-incharge.
Providing and applying internal wall and ceiling painting with two coats of premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50grams/ litre after applying white cement based putty of average thickness 1mm over the new plastered wall/existing surface including preparation of the surfces by scrapping existing paint/stains, with a coat of low VOC primer with emery paper to bring to smooth and even including applying additional coats wherever required to achieve even shade and colour of approved brand etc., all complete as directed by Engineer-incharge.
Plastering to external brick/block wall with 18 mm cement plaster in two coats under layer 12 mm thick cement plaster on the rough side with cement mortor 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).including leveling,curing and making the level smooth and at all heights, plaster drip course/ groove in plastered surface or moulding to R.C.C. projections and execute the work etc., all complete as directed by Engineer-incharge.
Providing ,applying and Finishing walls with Acrylic Smooth exterior paint of required shade with Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90litre/10 sqm) over the plastered wall/existing surface including preparation of the surfces by scrapping existing paint/stains, to achieve even shade and colour of approved brand etc., all complete as directed by Engineer-incharge.
Providing and applying synthetic enamel paint of approved brand and manufacture of required colour to give an even shade in One or more coats on old work by cleaning and srcapping to make the surface smooth before appling paint etc., all complete as directed by Engineer-incharge.
Designing, fabricating, testing, installing and fixing in position Curtain Wall system comprising of ACP & Tinted glass of approved colour and design with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc and with structural sealant, including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc and also with 6mm thick high performance glass.
For ACP sheet Cladding in curtain wall
For Glazing in Curtail wall i.e a Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., and also having the properties as visible light transmittance(VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc., all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified etc., all complete as directed by Engineer-incharge.
Providing and fixing Granite stone slab of with (18mm to 25mm thick), area of slab not less than 0.5sqm, like Ruby Red/Black/Cherry with gang saw cut, mirror polished, premoulded and prepolished, machine cut for platforms, vanity counters, and similar types of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc., all complete as directed by Engineer-incharge.
Providing and laying Polished Granite stone flooring and stair case raiser/partitions/divider/cladding and steps in colour Black, Cherry/Ruby Red or Equivalent in required design and patterns, in linear as well as curvilinier portions of building as complete as per the architectural drawings/Site condition with 18mm thick stone slab on 20mm (average) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand) laid and jointed with cement slurry and pointed with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing.nosing,chamfering and making grooves etc., complete as per direction of Engineer-in-charge. Note: Raiser to be polished granite and thread should be leather finish with edge chamfering.
Providing and laying Double Charged vitrified floor tiles of size of 600 X 600 mm or nearest availabe sizes, in floors over a screed of cement mortar (1:4) 20 mm thick for Paper Joint ( Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sqm including grouting the joints with white cement and matching pigments etc., all complete as directed by Engineer-incharge.
Providing and laying Glazed Vitrified tiles in Skirting/cladding over a screed of cement mortar (1:3)-Size of Tile 600x600 mm or nearest size available (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. all, complete as directed by he Engineer in charge.For skirting,wall cladding inside pantry/wash area/Toilets.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete etc., all complete as directed by Engineer-incharge.
Providing and laying Glazed Vitrified tiles Matt/Antiskid finish of size approximate size 600 X 600mm or site required size ,finish with Paper Joint in different sizes ( Thickness to be sepcified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sqm including grouting the joints with white cement and matching pigments etc., all complete as directed by Engineer-incharge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) of approved brand with ISI marked white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all connecting fittings and fixtures to make it operational completely, including cutting and making good to the walls and floors wherever required etc., all complete as directed by Engineer-incharge.
Providing and fixing Wall hung half pedestal Vitreous China Wash basin size of approx size 630x450 mm fixed with with C.I. brackets/rack bolts , single 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste coupling of standard pattern,P.V.C. waste pipe with waste fittings of 40mm dia and make it function of approved brand/make, including painting of fittings and brackets, cutting and making good the walls wherever required etc., all complete as directed by Engineer-incharge.
Providing and fixing 15mm nominal bore dia C.P. brass bib cock of approved quality conforming to IS as suiatbel to site conditions etc., all complete as directed by Engineer-incharge.
Providing and fixing PTMT shelf / Towel rails 440 mm long of approved quality and colour, weighing not less than 300 gms. or nearest available size complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour etc., all complete as directed by Engineer-incharge.
Providing and fixing bright finished brass hard drawn hooks(coat hooks) and eyes of 300mm size etc., all complete as directed by Engineer-incharge.
Providing and fixing toughened glass shelf of approved make with approximate size 600x120x5 mm with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete as per direction of Engineer-in-charge.
Providing and fixing 8 mm dia C.P. / S.S. Jet (Health Fuacet) with flexible tube upto 1 metre long with S.S. triangular plate on walls/Eureopean type W.C. material of approved make and quality etc., all complete as directed by Engineer-incharge.
Providing and fixing C.P. brass toilet paper holder of approved brand and fixing with screws,raw plugs etc., all complete as directed by Engineer-incharge.
Providing and fixing beveled edge mirror of inimum size 600x450mm of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers etc., all complete as directed by Engineer-incharge.
Constructing masonry Chamber (60x60x75cm) inside or outside (or approx. size as per site condition) , in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 etc., all complete as directed by Engineer-incharge.
Providing, fixing, testing and commissioning trap ( floor trap ) of approved make with 100 mm inlet and 75 mm outlet of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors , connection with PVC soil / waste pipe, necessary 150 mm thick cement concrete (1:2:4) for embedding the trap etc., all complete as directed by Engineer-incharge.
Providing and fixing Single socketed pipes of 110mm diameter unplasticised Rigid PVC water pipes conforming to IS : 13592 Type A of approved brand, on wall/floor face including bends,collars,elbows,shoe etc,jointing with/without seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion etc., all complete as directed by Engineer-incharge.
Providing and fixing Concealed Chlorinated Polyvinyl Chloride (CPVC) pipes of approved brand, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing, necessary reducers, tank adaptors etc. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and making good the walls etc as per direction of Engineer in Charge. Note: Dual plumbing line to be executed for Water closets
15 mm nominal dia Pipes
20 mm nominal dia Pipes
Providing and fixing Extrenal exposed Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Note: Dual plumbing line to be executed Water closets.
25 mm nominal dia Pipes
32 mm nominal dia Pipes
40 mm nominal dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank etc., all complete as directed by Engineer-incharge.
Providing and fixing Single socketed pipes of 110mm diameter SWR pipes of Type B confirming to IS 13592 of approved brand for Urinal,Basin & EWC out lets including bends,collars,elbows,shoe etc,jointing with/without seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion etc., all complete as directed by Engineer-incharge.
Providing and fixing Single socketed pipes of 75mm diameter SWR pipes of Type B confirming to IS 13592 of approved brand, on wall/floor face including bends,collars,elbows etc, jointing with/without seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion etc., all complete as directed by Engineer-incharge.
Providing and fixing Second Class Teak wood for frames of doors, windows, hand rails, frame work for partitions,paneling,table stands etc, cut to shape and required curvature with polishing fixed in position with hold fast lugs/with dash fasteners of required dia & length/SS Screws at all heights,with necessary moisture content test etc., all complete as directed by Engineer-incharge.
Providing and fixing 35mm thick flush door shutters conforming to IS :2202 (Part I) non-decorative type of approved brand/make, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25 mm minimum depth on all edges and well matched commercial 3ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges/180degree type with necessary screws and polish veneers on both faces of shutters,providing vision panel not exceeding 0.1 sqm in all type of door shutters etc., all complete as directed by Engineer-incharge.
Providing and fixing bright finished brass handles of minimum 125mm size( (Handling space) with screws etc., all complete as directed by Engineer-incharge.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws etc., all complete as directed by Engineer-incharge.
Providing and fixing bright finished brass tower bolts of 250x10mm (barrel type) with necessary screws etc., all complete as directed by Engineer-incharge.
Providing and fixing bright finished brass 100 mm mortice latch and lock with min. 4levers and a pair of lever handles of approved quality with necessary screws etc., all complete as directed by Engineer-incharge.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc., all complete as directed by Engineer-incharge.
Providing and fixing aluminium sliding door bolts(aldrop) of 250 x16mm , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc., all complete as directed by Engineer-incharge.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made etc., all complete as directed by Engineer-incharge.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter (minimum 30mm thick) of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws etc., all complete as directed by Engineer-incharge.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) etc., all complete as directed by Engineer-incharge.
Providing and fixing 12mm thick commercial ply conforming to IS : 1328 BWR type. plain lining/with pattern/grooves with necessary screws/nuts & bolts/ nails/fastners, including a coat of approved primer on one face, and fixed on wooden /steel frame etc., complete as per direction of Engineer-incharge (If Frame work is carried out shall be paid for separately under wooden frames item). For wall paneling,partitions,shelves etc., all complete as directed by Engineer-incharge.
Providing & Fixing decorative high pressure 1.0mm thick laminated sheet of plain / wood grain in gloss / matt/ suede finish to required pattern and combination as per the drawings etc on plywood with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality/brand.complete as per direction of Engineer-in-charge. For wall partitions,paneling,shelves etc., all complete as directed by Engineer-incharge.
Providing and laying Integral cement based water proofing treatment (With average thickness of 120 mm and minimum thickness at khurra as 65mm) including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern with 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 . The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%,Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlockingT-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
Providing and fixing factory made 3 track UPVC glazed/wire mesh windows comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of min 1.50 mm and upto 2.1 mm for Using R3 series with frame Approx. size of (98mm & above and upto 112 mm) x (40mm & above & and upto 52mm) or nearest available, both glazed and fly screen sash Approx. size of (55mm & above and upto 66mm) x (30mm & above and upto 43 mm ) or nearest available, with zinc alloy (zamak) powder coated handle on every glazed panel along with suitable locking system (touch lock, e.t.c), (Height upto 1.8m). conforming to EN: 12608 in any shape, white colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
Manufacturing, providing and fixing factory made UPVC glazed Fixed Partition/window/ Ventilator at all levels with/ without mullion/transom comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of min 1.70 mm for series R1, R2 profiles and min 2.1mm for series R3, R4 profiles with frame sizes as mentioned below, glazed, conforming to EN: 12608 in any shape, white colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc.
UPVC glazed fixed type Partition/Window/Ventilator of approximate size 1.5m x 1.5m Using R3 series with frame (55 mm & above ) x (45 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 2.5 metre) Note:- The rate is including including providing & fixing Glass.
UPVC glazed fixed type Ventilator with louvers of Approx. size .0.6 m X 0.9 m using R1 series with frame Approx. size of (33mm & above) x (35mm & above) or nearest available & mullion (33 mm & above)x (50 mm & above) or nearest available, if necessary. (Height upto 0.9 metre) Note:- The rate is including providing & fixing louvers and 5mm thick glass.
Supplying and fixing of UPVC openable (single/double leaf) multichambered and stiffened /reinforced framed door with profile colour as natural white of the following specifications: Casement door double panel/ single panel with french (false) Mullion, if necessary with Zinc alloy (Zamak) 3D hinges(4nos), suitable locking system, Zinc alloy (Zamak) powder coated handles on both sides. Using R3 series with outer frame Approx / nearest available size of (60mm & above upto 76mm) x (58mm & above upto 62mm) x (2.2mm and above) and shutters with approximate profile sections : (84mm and above upto 102mm) x (60mm and above upto 70mm ) x 2.2mm and above or nearest available size. The corners of all the profiles of frames and shutters shall be homogenously fusion heat welded without any gaps. The shutters shall have necessary handles, locking and other associated fittings to facilitate smooth operation. Both frame and shutters shall be reinforced with GI prifiles of thickness 1.25mm. The door unit has to be fixed to the existing masonry opening using anchor fasteners. The gaps between door frames and masonry walls shall be filled with silicon or any other suitable filler materials.Glazing to be done with 6mm toughened glass. Note:Door height is considred upto 2.5mtr Height
Providing and fixing Polycarbonate system in all span and all height in dome, pyramid or any other shape as per the direction of Engineer -in-Charge complete. The system shall consist of: Multi cell five layer and above polycarbonate panel shall be 12 mm thick (min.) single panel. The weight of the panel only shall not be less than 2500 grams per square meter. Panel width shall be not less than 900mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. The panels shall be uniform in color with an integral Tight‐Cell core. Panels shall be manufactured with Vertical Standing Seam at both sides of the panel. Welding or gluing of up stands or standing seam is not acceptable. Snap‐on connector to interlock the panels shall have a grip‐lock double tooth locking mechanism to ensure maximum uplift capability. Panels shall be secured with snap‐on connectors with / without continuous double wall Aluminium spacer along the standing seam. Panels shall be fixed on Purlins with the Z- Type Stainless Steel Fastener and connectors. The fastener shall be fixed on Purlin using minimum 3 screws for maximum wind uplift capability. Panel shall be factory sealed/end welded panels with additional End‐cap/Aluminium U‐Profile (mill finish) for ends.Panels shall be co‐extruded UV protected. Panel shall be co‐extruded with special anti glare compound to make it anti‐glare/soft light to prevent glare and sun streaks. Color: OPAL OR REFLECTIVE GREY (Antiglare- Softlite) or as approved. The full system shall be fitted on MS purlins perpendicular to direction of sheeting with purlin spacing as specified by manufacturer.Note: The cost of the MS pulins and frame work will be paid separately. External surface area of the sheet/polycarbonate will be measured for payment.
Rupees Two Crore Thirty Lakh Twenty Six Thousand Five Hundred Eight and Eighty Four Paise Only
10KVA Online UPS- Input supply: Three Phase, Output supply: Three Phase with 30min backup
Supply, fixing to existing MS perlins at approx. 5-6 mtr height, including using suitable MS angle frame work with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type highbay LED lighting fixture of wattage not exceeding 80watts made out of high pressure diecast aluminium housing, diffuser made of high grade toughened glass(or as per OEM standards), integral control gear, eye hook and surge protection of 10kV(Internal/external) etc., . The technical parameters of lighting fixtures are as below: The luminaire should have Lumen efficacy ≥ 150lm/watt and lumen output not less than 12000lumens, PF>0.90 and Colour temperature shall be ≥5700K, CRI≥70, THD <10%, IP66/65 operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures and other standard accessories complete in all respects and as directed by Engineer in-charge. The fitting may be of Bajaj model no: Novabay 80W WH NB PC SD XE/ Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminares & LM80 certificate for LED shall be produced.
Supplying, Installation, Testing & Commissioning of 36W Panel light 2x2 ft., of Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (As per CPWD Specification).
Supply and fixing on existing wall / ceiling using steel conduit suspension with ball & socket arrangement, testing & commissioning of surface mounting, Industrial Batten 2X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output Efficacy of minimum 120 lm/W., comprising of white powder coated CRCA sheet steel housing , operating on single phase 230V 50Hz AC supply, built-in electronic driver, LM 79 certification for luminaire. Other standard accessories including necessary inter-connections and supply of 2 Nos of 18/20W T8 LED Tube, complete in all respects and as directed by engineer-in-chage. Make & model: The LED tube & batten shall be of STREAKNEOT8UPTO2X22WSSBSWH & TITANIAPLUS2.01213T8SSTL18WLED865SPC / Equivalent model of approved make luminaries which meets the above technical specification and as directed by Engineer-in-charge.
Supply and fixing on existing wall/ceiling, testing & commissioning of surface mounting Batten type 20W LED light (four feet) with mircowave motion technology with minimum lumens output of 2000 lumens, comprising of aluminium housing, operating on single phase 230V 50Hz AC supply, built-in electronic driver, Other standard accessories including necessary inter-connections, complete in all respects and as directed by engineer-in-chage. The LED batten light may be of Havells, LUMILINESMART20WLED865PCSSG2/Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supplying, installation, Testing & commissioning of 18W LED Recessed/surface Down lighter (Round) SMD type Powder coated die cast /Extruded aluminum body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with driver efficiency >85%, Operating voltage AC 140-270volt, freq 50/60 Hz, operating temp range-15 deg to 40 deg centigrade internal surge protection of 2.5KV with Short & Open circuit protection, THD <10%, P.F≥0.95, IP20, CRI>80, UGR (Unified Glare Rating)<19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/ 4000°K/5700CK/6000°K/6500°K (As per ANSI Bin), SDCM(Standard deviation color Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C). Manufactures word mark/name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. As required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/watt output. LM79 & LM80 Test report from NABL Lab for all testing required for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-In–Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90C). (As per CPWD Specification).
Supplying, installation, Testing & Commissioning of 45W Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (As per CPWD Specification). Supply, fixing & bending to shape as per site requirement of 32mm dia Class B GI pipe on the wall including necessary acccessories for installation of light fixture as per E-I-C.
Supply, Installation, Testing and Commissioning of 1200mm Sweep ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, suitable length down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/Min/Watt) > 6.0, minimum air delivery 210CM/Min, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (As per CPWD Specification.)
Supply, installation, testing & commissioning of Industrial type heavy duty Exhaust Fan (1 phase) of 300mm dia of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 200mm dia PVC type Exhaust Fan with louvers, minimum air delivery of 850CMH, connecting cord with 6A, 3 pin plug top and with all necessary accessories, complete in all respects and as directed by Engineer-in-charge. The exhaust fan may be Havells model no: Ventil air DX HS or equivalent in other HAL approved makes and as directed by Engineer-in-charge.
Supply and fixing of weather proof cable junction box suitable for 1.5- 4Sqmm with terminals of approximate size 104mm x 104mm x 70 mm Hensel Cat. No. DK 0404 G or equivalent in Legrand/ Schneider/ Hagar make only. The Box shall be mounted at suitable height on the truss using suitable size MS angle frame work with painting as per EIC, with cable entry knock-outs, including rigid support for all components, Din channel, required fasteners totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-65 complete in all respects and as directed by Engineer-in-charge. Note: MS supports will be paid separately.
Distribution Boards
6way VTPN MCCB DB.
4 way VTPN MCB DB
6 way HTPN MCB DB
4 way HTPN MCB DB
12 way SPN MCB DB
Supply, fixing, testing & commisisoning of following rating MCCB/MCB/RCBO in the existing Distribution board/powder coated enclosure as directed by Engineer-in-Charge.
63-100A 25kA FP 415V, MCCB
40-63 amps. ratings, FP MCB, "C" curve, 10 KA breaking capacity.
25-32 amps. ratings, FP MCB, "C" curve, 10 KA breaking capacity.
40-63 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity.
5A to 32A TP MCB, C Curve , 10 KA breaking capacity.
5A to 32A SP MCB, C Curve, 10 KA breaking capacity.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, installation(surface/recess), testing and commissioning of 2/3/4 Way Powder coated Enclosure with provision to mount MCB/RCCB/RCBO and other modular devices.
Supply, laying, testing & commissioning of following size Aluminium/Copper LT Armoured power cables.
3.5CX 50 Sqmm Aluminium armoured conductor
3.5CX 25 Sqmm Aluminium armoured conductor
4CX 16 Sqmm Aluminium armoured conductor
4CX 10 Sqmm Aluminium armoured conductor
3C X 2.5 Sqmm Copper armoured conductor LT Cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade as required
3.5C X 50 sq. mm Al arm cable
3.5C X 25 sq. mm Al arm cable
4C X 16 sq. mm Al arm cable
4C X 10 sq. mm Al arm cable
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE armoured/Unarmoured copper conductor cable of 1.1 KV grade as required
3Cx2.5Sqmm Armoured Copper cable
Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
Wiring to single light point/Fan point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to three light point controlled by 1 No 6A, 250V gr. flush modular type SP switch complete in all respects.
Wiring to exhaust fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2sets of 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20MM PVC Conduit
25MM PVC Conduit
32MM PVC Conduit
Supply and fixing on wall/ partition wall using necessary mounting arrangements for 105x50mm size DLP-PVC adaptable trunking system for laying power and Data/Telephone cables/wires with full top cover, necessary accessoires such as end caps, flat angle, T joints, external/internal angle, flat junction, Body joint, cover joint, required cabling accessories etc., complete in all respects as directed by Engineer-in-charge.
Supply, fabricating and installing of Following size perforated GI cable trays with cover including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling/fixing to the wall/RCC beam/iron structures as per site requirement complete in all respects and as directed by Engineer in charge. (Note:-M.S. angle supports will be measured separately).
150 x 50 x 2mm thick cable tray with 1.6mm thick cover.
Supply & providing earth stations using 600x600x3.15mm thick copper plate electrode complete at 2.5 mtr. below the ground level with 20mm dia class B G.I pipe for watering, G.I funnel etc. & Cement concrete base of minimum size 750x750x100mm thick shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc. and providing cement concrete chamber of inside dimension 300x300x300mm with a wall thickness of 120mm using 1:2:6 CC above the base concrete including providing 50mm thick RCC cover including required salt & charcoal, 2runs of 50x6 mm(300mm) copper strip from plate electrode upto top of the chamber etc. as per technical specification enclosed with the tender documents & as per IS 3043 complete in all respects.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Design, Fabrication, Supply and fixing/grouting/welding on wall/ceiling/ truss of suitable size MS angle iron supports/ flat/ brackets for cable tray supports, as per site requirement and painting the same with two coats of synthetic enamel paint over a coat of zinc chromite primer complete in all respects and as directed by EIC/OIC.
Excavation in all types of soil for Cable trench including refilling, consolidating of soil after laying the cable including ramming and levelling to smooth finish as per the Technical specifications enclosed and as directed by the Engineer-in-charge.
Data Items
Supplying and fixing of 9U Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. Approved Make:APC/VALRACK/NETRACK/RITTAL
Supplying and drawing 12 core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db/ km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required. Approved Make:COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply and fixing 24 port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single /Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. Approved Make:COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supplying, drawing, Installation, Testing and commissioning of 2Runs of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius :< 4 X Cable Diameter at –5°C ± 1 Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply, Fixing in flush with wall/on Aluminium partition as per site condition, testing & Commissioning of 2 nos of RJ-45 modular type sockets for Data points including supply of suitable size modular MS/PVC surface mounting box with base plates, glossy finish front covers, labelling etc., with necessary interconnections and chipping the wall, replastering to smooth finish etc., wherever required complete as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX/Legrand/ Schneider/ HAL approved makes
Supply and laying of 50mm dia, PE-80, PN6 ISI marked HDPE pipe confirming to IS 4984:19955 including suitable jointing using welding as required in the excavated trench/duct/at road crossings for encasing cables complete in all respect as directed by Engineer-in-charge.
Voice Items
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 10 pair krone type telephone connector junction box including krone connector/s with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 10 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects.
Supply & drawing of 0.5 mm dia copper conductor PVC insulated 4 pair colour coded and twisted unarmoured telecommunication cables in the existing PVC conduit as per standard practice including necessary inter connections & end terminations. As per CPWD Specification.
Supply, Fixing, in the existing GI /PVC box as per site requirement, testing & Commissioning of 1 No. Twin RJ-11 telephone socket outlets with shutter with necessary interconnections complete as directed by Engineer-in-charge.
Rupees Sixteen Lakh Twenty One Thousand Thirty Seven and Twelve Paise Only
Rupees Two Crore Forty Six Lakh Forty Seven Thousand Five Hundred Forty Five and Ninety Six Paise Only
Approximate Amount Put to Tender
Rupees Forty Four Lakh Thirty Six Thousand Five Hundred Fifty Eight and Twenty Seven Paise Only
Rupees Two Crore Ninety Lakh Eighty Four Thousand One Hundred Four and Twenty Three Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
TN54.pdf
pdf • 0.77 MB
53TBF.pdf
pdf • 3.75 MB
53PQF.pdf
pdf • 0.20 MB
53PBF.pdf
pdf • 0.75 MB
CivilTenderDrawings.pdf
pdf • 0.78 MB
ElectricalTenderDrawings.pdf
pdf • 1.74 MB
53ECSForm.pdf
pdf • 0.48 MB
53UNDERTAKING.pdf
pdf • 0.57 MB
53CHECKLIST.pdf
pdf • 0.19 MB
53PQ.xlsm
xlsm • 0.03 MB
53PB.xlsm
xlsm • 0.94 MB
AMD25092026.pdf
pdf • 0.09 MB
Amd02A5340.pdf
pdf • 0.09 MB
AMD11092026.pdf
pdf • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .