Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹28.5 L+₹52,641 (1.88%)Rejected-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L3₹28.5 L+₹53,615 (1.92%)Rejected-AOC | L3 | Rejected-AOC NOT BEING LOWEST | |
| 4 | L4₹28.6 L+₹66,349.80 (2.37%)Rejected-AOC | L4 | Rejected-AOC NOT BEING LOWEST | |
| 5 | L5₹28.6 L+₹69,811 (2.50%)Rejected-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-AOC NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | SWAMI ENGINEERS L2 | Arneja Builders L5 | RUPINDER SINGH SODHI L4 | m/s panchmukhi builders L3 | M/s Harmans L1 | Jawandha Enterprises L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Cleaning of sludge under ground sewage network including manholes obstruction free by removing any type of blockage in any kind of manhole or lines including removing blockage inside the building from EWC/WC/floor trap/gully trap etc in old cantt area by deploying adequate manpower and suitable T&P so as to avoid damage to the line/structure complete all as specified and as directed.
Note:-
(i) Sewage network under new cantt area consists various dia of pipe lines varying from 10mm dia to 450mm dia.
(ii) Contractor or his rep will report daily at complaint cell of old cantt at 9.00 AM for collection of complaints from the concerned JE's Incharge, on failure a penalty of Rs. 500/- per day in addition to delay in attending the complaints will be charged. A seperate muster roll register will be maintained in AGE office.
(iii) Immediately after lodging daily complaints by the users or directed by the EIC consequent to his routine check, the concerned JE shall intimate/hand over the complaint to the contractor or his rep for attending complaints to the satisfaction of user / Engineer-in-charge within 24 Hrs. In case of failure to attend the complaint within specified period, a penalty of Rs.100/- per day per complaint shall be imposed on the contractor for the period the work remains incomplete. After 03 days from the date of handing over of complaint, the unattended complaints shall be got completed from any other agency at the risk and cost of the contractor without any notice to the contractor.
(iv) In case of disputes as to delay happened in attending the complaint or inadequate period, decision of Accepting Officer shall be final, conclusive and binding.The number of person provided by contractor is 3 nos.
(v) During cleaning of deep manholes or pipe lines, for precautions, contractor will also arrange oxyzen cylinder of suitable size, rope/chain to the workmen and cost there of shall be included under this item. | 11 | Each Job | 55,000 ₹6,05,000 | 50,000 ₹5,50,000 | 50,000 ₹5,50,000 | 60,000 ₹6,60,000 | 35,000 ₹3,85,000 Lowest | 35,000 ₹3,85,000 Lowest |
| 2.00 | Cleaning the sewage soakage pips, septic tanks of any dia depth and in any location etc by taking out complete sludge water and solids mechanically by HCV mounted suction discharge machine having flow back facility with sludge tank of adequate capacity removing & disposing the entire retrieved material to a distance not exceeding 1000 meter outside the periphery of defence land and covering the entire sludge with local earth complete all as directed by the engineer-in-charge.
Note :- 1. The suction cum jetting machine and fuel provided by department for jetting only. however the small repairs if occurs will be done by contractor through his own expenses.
2. Depth of sludge in the pit shall be measured from the bottom of pit to the existing water/effluent lever prior to ordering the cleaning in the presence of EIC. | 300 | Cum | 140 ₹42,000 | 50 ₹15,000 Lowest | 150 ₹45,000 | 60 ₹18,000 | 100 ₹30,000 | 75 ₹22,500 |
| 3.00 | Excavation in trenches in soft/loose soil not exceeding 1.50 Mtr wide and not exceeding 1.50 Mtr in depth and getting out in soft/loose soil complete all as specified and directed Engineer-in-Charge | 600 | Cum | 50 ₹30,000 Lowest | 70 ₹42,000 | 50 ₹30,000 Lowest | 60 ₹36,000 | 50 ₹30,000 Lowest | 100 ₹60,000 |
| 4.00 | All as per Serial items No. 3 herein before but exceeding 1.5 Mtr and not exceeding 3.00 Mtr depth
Note :- The rate quoted should include provision of oxygen cylinder , safety belts and helmet in case of deep earth work as and when necessary. | 100 | Cum | 70 ₹7,000 | 80 ₹8,000 | 60 ₹6,000 Lowest | 80 ₹8,000 | 60 ₹6,000 Lowest | 150 ₹15,000 |
| 5.00 | Demolition of Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles | 107 | Cum | 40 ₹4,280 | 100 ₹10,700 | 50 ₹5,350 | 50 ₹5,350 | 10 ₹1,070 Lowest | 100 ₹10,700 |
| 6.00 | M&L Brick work using Sub Class "B" brick, designation 100, straight or curved on plan not exceeding 6 Mtr means radius built in CM 1:4 complete all specified and directed by Engineer-in-Charge | 90 | Cum | 2,200 ₹1,98,000 | 2,800 ₹2,52,000 | 2,000 ₹1,80,000 Lowest | 3,000 ₹2,70,000 | 2,500 ₹2,25,000 | 3,500 ₹3,15,000 |
| 7.00 | All as per item no 6 above but using old Bricks complete all as specified and as directed by engr in charge. | 17 | Cum | 600 ₹10,200 | 1,000 ₹17,000 | 300 ₹5,100 Lowest | 1,200 ₹20,400 | 500 ₹8,500 | 2,000 ₹34,000 |
| 8.00 | Taking down cement plaster on brick walls built in cement mortar including raking out joints and concrete surfaces as in wall or ceiling etc. including hacking for key, scrubbing down with water etc complete all as specified and directed. | 100 | Sqm | 5 ₹500 Lowest | 5 ₹500 Lowest | 5 ₹500 Lowest | 25 ₹2,500 | 10 ₹1,000 | 15 ₹1,500 |
| 9.00 | M&L Cement plaster 15mm thick on fair faces of brick wk in cement mortar 1:4 and finished even and smooth without using extra cement with/without WPC complete all as specified and directed by Engr-in-Charge (WPC where required shall be measured and paid separately) | 250 | Sqm | 110 ₹27,500 | 130 ₹32,500 | 100 ₹25,000 Lowest | 190 ₹47,500 | 110 ₹27,500 | 150 ₹37,500 |
| 10.00 | M&L Applying 02 coats of cement paint by using roller to wall surfaces complete all as specified and directed. | 120 | Sqm | 15 ₹1,800 | 15 ₹1,800 | 8 ₹960 Lowest | 20 ₹2,400 | 10 ₹1,200 | 25 ₹3,000 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
23 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ MOHAMMED AQIL AZEEM
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
CERTAIN REPAIRS TO SEWAGE SYSTEM AND DAY TO DAY COMPLAINTS ATTENDING UNDER AOR AGE BR-I GE(N) PATIALA
2025_MES_722809_1
GE (N)/TOKEN-38/2025-2026
Open Tender
Civil Works
Item Rate
330 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE N PATIALA
₹70,000
Yes
9 Oct 2025
26 Jul 2025
25 Aug 2025
26 Jul 2025
23 Aug 2025
9 Aug 2025
Amount
Cleaning of sludge under ground sewage network including manholes obstruction free by removing any type of blockage in any kind of manhole or lines including removing blockage inside the building from EWC/WC/floor trap/gully trap etc in old cantt area by deploying adequate manpower and suitable T&P so as to avoid damage to the line/structure complete all as specified and as directed. Note:- (i) Sewage network under new cantt area consists various dia of pipe lines varying from 10mm dia to 450mm dia. (ii) Contractor or his rep will report daily at complaint cell of old cantt at 9.00 AM for collection of complaints from the concerned JE's Incharge, on failure a penalty of Rs. 500/- per day in addition to delay in attending the complaints will be charged. A seperate muster roll register will be maintained in AGE office. (iii) Immediately after lodging daily complaints by the users or directed by the EIC consequent to his routine check, the concerned JE shall intimate/hand over the complaint to the contractor or his rep for attending complaints to the satisfaction of user / Engineer-in-charge within 24 Hrs. In case of failure to attend the complaint within specified period, a penalty of Rs.100/- per day per complaint shall be imposed on the contractor for the period the work remains incomplete. After 03 days from the date of handing over of complaint, the unattended complaints shall be got completed from any other agency at the risk and cost of the contractor without any notice to the contractor. (iv) In case of disputes as to delay happened in attending the complaint or inadequate period, decision of Accepting Officer shall be final, conclusive and binding.The number of person provided by contractor is 3 nos. (v) During cleaning of deep manholes or pipe lines, for precautions, contractor will also arrange oxyzen cylinder of suitable size, rope/chain to the workmen and cost there of shall be included under this item.
Cleaning the sewage soakage pips, septic tanks of any dia depth and in any location etc by taking out complete sludge water and solids mechanically by HCV mounted suction discharge machine having flow back facility with sludge tank of adequate capacity removing & disposing the entire retrieved material to a distance not exceeding 1000 meter outside the periphery of defence land and covering the entire sludge with local earth complete all as directed by the engineer-in-charge. Note :- 1. The suction cum jetting machine and fuel provided by department for jetting only. however the small repairs if occurs will be done by contractor through his own expenses. 2. Depth of sludge in the pit shall be measured from the bottom of pit to the existing water/effluent lever prior to ordering the cleaning in the presence of EIC.
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtr wide and not exceeding 1.50 Mtr in depth and getting out in soft/loose soil complete all as specified and directed Engineer-in-Charge
All as per Serial items No. 3 herein before but exceeding 1.5 Mtr and not exceeding 3.00 Mtr depth Note :- The rate quoted should include provision of oxygen cylinder , safety belts and helmet in case of deep earth work as and when necessary.
Demolition of Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles
M&L Brick work using Sub Class "B" brick, designation 100, straight or curved on plan not exceeding 6 Mtr means radius built in CM 1:4 complete all specified and directed by Engineer-in-Charge
All as per item no 6 above but using old Bricks complete all as specified and as directed by engr in charge.
Taking down cement plaster on brick walls built in cement mortar including raking out joints and concrete surfaces as in wall or ceiling etc. including hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L Cement plaster 15mm thick on fair faces of brick wk in cement mortar 1:4 and finished even and smooth without using extra cement with/without WPC complete all as specified and directed by Engr-in-Charge (WPC where required shall be measured and paid separately)
M&L Applying 02 coats of cement paint by using roller to wall surfaces complete all as specified and directed.
M&L Cement concrete (1:2:4) type B-1 using 20mm graded machnically crushed stone agg as in benching of manholes coping plinth course bands stops etc incl necessary form works complete all specified and directed by Engineer-in-Charges
Demolition by breaking up drain pipes salt glazed stone ware pipe, AC or reinforced concrete of internal dia 100/150/200/300mm dia jointed in cement mortar and taking out of from trenches removing the debries from site complete all as specified and directed by Engineer-in-Charge
M&L Reinforced concrete pipes of 150mm dia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
M&L Reinforced concrete pipes of 200 mm dia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
M&L Reinforced concrete pipes of 300 mm dia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
M&L concrete bed to drain pipes 150mm dia 1:3:6 type C2 incl packing under,and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed
M&L concrete bed to drain pipes200mm dia 1:3:6 type C2 incl packing under,and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed
M&L concrete bed to drain pipes 300mm dia 1:3:6 type C2 incl packing under,and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed
M&L PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as in foundation of manholes complete all as specified and directed
S&F factory made precast concrete manhole/drain covers of size exc 0.12sqm but n exc 1.00 sqm and thickness not less than 50mm and shape of sqare/rectangular/circular fixed in position complete all as specified and directed. For measurement purpose it will be measured in cubic meter.
Returning and filling incl spreading, levelling, water and well ramming in layers not exceeding 25cm thick complete all as specified and directed Engr-in-charge
Demolition of reinforced cement concrete of any description and in any position complete all as specified
Supply of integral water proofing compound.
M&L Removal of excavated material n. exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point
M&L Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and formingbranch channel (1/2 round or 3/4section) in cement concrete 1:2:4 mix type B-1smooth finished and reforming benching as required of 150mm dia of pipe complete all as specified and as directed.
M&L Cast iron Nahani trap 100 mm dia with long arm not less than 450mm grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specifed and as directed.
S&F CI 'P' or 'S' trap suitable for 100mm bore pipe, including jointing with run lead at one end, fixed as in repairs complete all as specified and directed.
S&F Cast iron soil, waste and vent pipe, 100mm bore, sand cast in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections complete all as specified after taking down of existing unserviceable pipe fixed in repair complete all as specifed and as directed.
S&F Cast iron soil, waste and vent pipe, 75mm bore, sand cast in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections in repair complete all as specifed and as directed.
S&F CI gully traps, Centrifugal type 150 x 150 mm size, square or roundmouthed, type 'P' or 'S' fixed in repair complete all as directed and specified by Engr-in-Charge.
S&F CI Bends (any radius), for 100mm bore CI pipes diminishing pieces or tapers (longer bore measured) fitted with oval access doors complete all as specified.
S&F cast iron junction combination 'T' equal or unequal for 100mm bore with access door as in repair complete all as specified and directed by Engr-in-Charge.
S&F single Y-shaped CI junction pipes, ordinary or inverted (spigot or socket type) for 100mm bore pipes complete all as specified and directed by Engr-in-Charge.
S&F 110mm PVC (SWR) pipes single socketed, in any length with length with rubber ring joints, laid trenches/wall as specified and directed by Engr-in-Charge.
M&L PCC 100mm thick (1:2:4) type B-2, (using 40mm graded stone agg) as in road cuttings/path complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone agg) as in sub base of path or hard standing complete all as specified and directed
Dismantling, floor, hearth or wall tiling including CM (bedding but not backing), removing servicable tiles to store & rubbing off the premises complete all as specified and as directed.
M&L for non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles and over and icluding 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for Glazed ceramic coloured printed/digital tiles 7to 8mm thick (square/ rectangular) on vertical surface such as skirting , dado etc. over and including 10 mm thick rendering in cement mortar 1:4 thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles complete all as specified and directed by Engineer-in-Charge.
Demolition of unreinforced cement concrete in floors and pavings n exc 15cm thickness of any description and in any position complete all as specified
M&L factory made machine perssed rubber moulded ISI marked precast cement concrete interlocking paver block any shape and size of with grey cement and pigment tiles confirming to IS-15658-2006 of 60mm thickness M-35 grade and including filling of interstices with fine sand over including 25mm thick layer of sand cushion complete all as specified and directed by Engr-in-Charge.
S&F Vitreous china squattig pan of Orissa patten size 580 x 440 white CI P or S trap joint run and lead front or back inlet with integral footrest including connection to trap and to flushing pipe, anti-syphonage pipe etc, complete and making good to floor in CM 1:3 all as directed and specified.
S&F flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.
S&F Stainless steel grating doom openable 100mm sq size (Minimum Weight 25 grams) with/without hole including fixing with white cement including taking down old unserviceable existing one complete all as specified and directed by Engineer-in-Charge.
M&L factory made rubber moulded coloured chequered tiles 30cm x 30cm x 22mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry as in floor/path including and over 15 mm thick screed bed in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for factory made rubber moulded pre-cast cement concrete type B1 1:2:4 (20mm graded agg) of size 300 x 300 x 100mm and fixing in CM 1:4 in kerb stone use with plain fair faces, including chamfers, weatherings, throating etc and setting in mortar complete with joints to match including embedding in the ground to depths indicated and tamping ground around and also for removing any surplus soil to a distance n.exc 50 mtrs complete all as specified and as directed by Engr-in-Charge.
SWAMI ENGINEERS (BID ID -3388938)
m/s panchmukhi builders (BID ID -3395503)
RUPINDER SINGH SODHI (BID ID -3393904)
Arneja Builders (BID ID -3392538)
Jawandha Enterprises (BID ID -3404183)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .