Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.5 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹5.9 L+₹42,130 (7.68%)Rejected-Finance B 17 2 GALI NO 20 JITAR NAGAR NEAR PARVANA ROAD KRISHNA NAGAR EST DELHI 51 | NEW DELHI | DELHI | 110001 | 2 | Rejected-Finance 2 |
Tender Value
₹6.4 L
EMD Value
₹12,762
Closing Date
20 Dec 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-III/RZ
EEE-III/RZ
Improvement/Development of EI and other allied work in MCPS F-Block Mangolpuri in ward no.50 under Rohini Zone
2023_MCD_177760_1
EEE-III/RZ/TC/2023-24/16.1
Open Tender
Electrical Works
Item Rate
180 days
EEE-III/RZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹12,762
30 Apr 2025
13 Dec 2023
21 Dec 2023
13 Dec 2023
20 Dec 2023
13 Dec 2023
Amount
OD16182/2023-2024:DSR22 (1.8.3)Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
OD16183/2023-2024:SR22 (1.17.12) Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
OD16184/2023-2024:SR22 (1.14.2) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 2.5sq. mm + 1 X 2.5 sq. mm earth wire
OD16185/2023-2024:DSR 22 (1.17.12) Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3x2.5 sq. mm
OD16186/2023-2024:DSR22 (1.21.1) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20 mm
OD16187/2023-2024:DSR 22 (1.17.30) .Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3x6 sq. mm
OD16188/2023-2024:DSR 2022 (1.15.3) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
OD16190/2023-2024:DSR-22 ( 5.2) Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
OD16371/2023-2024:DSR-22(5.15) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD16193/2023-2024:SR-22 2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
OD16194/2023-2024:Civil SR 18 (10.18) P/F circular/hexagonal cast iron/MS sheet box for ceiling fan clamp of internal dia.140 mm.73 mm.height top lid of 1.5mm thick MS sheet with its top surface for proper bending top lid shall be secured in to cast iron MS sheet box by means of 3.3 mm dia.be made of 12 mm.dia.MS bar bent to shape as per standard drawing complete as reqd.
OD16195/2023-2024:SR22 (1.58) Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD16196/2023-2024:DSR 22 (1322) Supply of 3 mm thick phenolic laminated sheet
OD16197/2023-2024:Supply of 15"(380mm) Sweep 1400 r.p.m. exhaust fan heavy duty complete with shutter, blade etc. as required
OD16198/2023-2024:DSR-22 Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD16199/2023-2024:DSR-22 (7.7.1) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq. mm (clamped with 1mm thick saddle)
OD16200/2023-2024:DSR-22 (7.6.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sq. mm
OD16367/2023-2024:DSR-22 (7.5.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm
OD16201/2023-2024:DSR-22 (2.15.3) Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps.
OD18401/2023-2024:DSR-22 (14.16.1) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
OD16202/2023-2024:DSR-22 (2.2.14) Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(a) 125 Amp 36 KA, FPMCCB
OD16203/2023-2024:DSR-22 (2.10.1) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
OD16204/2023-2024:DSR-22 (2.12.2) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. A)63 A.
OD16205/2023-2024:DSR-22 (2.3.3)Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (b) 12 way Double door
OD16206/2023-2024:SR-22 (1.30) Supplying and fixing metal box 180mmX100mm X60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
OD16207/2023-2024:DSR-22 (1.23.5) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 A socket outlet
OD16208/2023-2024:DSR-22 (1.23.3) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16Amp.switch.
OD16209/2023-2024:DSR22 (1.23.4) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 3 pin 5/6 A socket outlet
OD16210/2023-2024:DSR22 (1.23.1) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 5/6 amps switch
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.1.4:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*16 sqmm
122.2.29:SITC of 100W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =100 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.236:Rewinding of AC ceiling fan of all sizes and make including oiling, greasing as required New Model (Light Weight)
122.2.238:Replacement of ball bearing of size 117/120 NBC equivalent SKF make as required.
122.2.239:Replacement of fan condenser 2.5 mF as required.
bharat electricals & electronics
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .