Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹8.7 L+₹78,694 (9.93%)Rejected-Finance BLOCK NO 6 7 WING NO 3 RAHUL COMPLEX I ST BUS STAND GANESHPETH GANESHPETH NAGPUR NAGPUR MAHARASHTRA 440018 | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
20 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Nagpur
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR/MAINTENANCE / REPLACEMENT OF STREET LIGHT AND PERIMETER LIGHT FITTINGS AT VSN, MCCF, 22 P and S, AKSC NAGPUR
2020_MES_400765_2
GE/NAG/20-21/8406/53
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Nagpur
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE AF Nagpur
₹16,000
Yes
12 Apr 2021
23 Feb 2021
22 Mar 2021
23 Feb 2021
20 Mar 2021
24 Feb 2021
60 days
Amount
Labour only for checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV, Metal Halide,T-5,Post top, LED light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge. NOTES (i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools etc and screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor.
Supply only following materials suitable for various type of street light, security light for replacing against item no 1 here in before. Make of spares CG,Philips,Wipro
Electronic Ballast suitable for T5 4x14 W light fittings.
Electronic Ballast suitable for T5 2x24 W light fittings.
Copper wound Ballast suitable for 70 watt SV/MH light fitting
Copper wound Ballast suitable for 400 watt SV/MH light fitting
Lamp suitable for T5 14 W light fittings.
Lamp suitable for T5 24 W light fittings.
Lamp single end suitable for 70 watt MH light fitting
Lamp single end suitable for 400 watt MH light fitting
Electronic igniters suitable for 70 to 400 Watt.
Capacitor 33 mfd HPSV, MV, MH lamp fittings
Lamp holder suitable for T5 light fittings
Lamp holder suitable for 250/400 watt SV/MH lamp light fittings
LED Lamp suitable for 9 W light fittings.
Driver for 40 Watts LED street light luminaries complete.Make : CG S0DQL1-54-700-40W
Driver for 45 Watts LED street light luminaries complete. Make : CG S0DQL-65-700-45W
Driver for 135 Watts LED flood light luminaries complete. Make :CG X150C070V210FNI1BO
Dismantling and Taking out old unserviceable Street Light fittings and Supply fixing 90W LED street light with pressure die cast aluminum housing & toughened glass with IP-66 degree of protection, Individual LED's must have peanut lenses for better throw across & along the road ,with luminaire efficiency of greater than 85Lumen/Watt (Minimum lumen output of luminaire should be3800Lumens ), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K) , The luminaire should have 5KV surge protection, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintainable driver compartment for easy access to driver during maintenance. The Driver used must be a constant current driver with efficiency of ≥ 85% The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire. Make : CG LSTN-90-CDL-A or eqival,Wipro and Philips.
Supply and fix bracket for street light fittings made out of 40 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size all as specified and as directed.
Taking down old unserviceable UG cable and Supply & Laying for XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq mm, 4 core in trenches or fixing in walls / poles or drawing through pipe including testing after laid and jointed all as specified and as directed.
Taking down old unserviceable UG cable and Supply & Laying cable XLPE insulated screened Meter PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engineer-in-Charge
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge
M & L for Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 of size 40 mm dia laid in trenches for passing of LT cable complete all as specified and directed.
M & L for PCC cable route indicator in mix of 1:2:4 type B1 of size 450x200x75mm with oval shape and writing the letter HT/LT cable with synthetic enamel paint and embedded with PCC foundation type D2 1:4:8 of size minimum 250 mm depth including necessary earth work complete all as specefied and directed.
Supplying and fixing un-reinforced precast concrete cable cover class LV type 1 with peak, size 250mm x 150mm x 40mm all as specified and directed by Engr-in-Charge
Excavation of road cutting by manually including making good to distrubed surface after the completion of work with PCC 1:2:4 type B-2 on top not less than 150 mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc all as specified and as directed.
M & L for galvanised iron tubing dia light grade of size 40 mm dia with all fitting laid under floor / road crossing or in trenches or fixed to pole /walls with clamps as required including sealing of pipe ends with approval sealing compound etc complete all as specified and directed.
M & L for High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 of size 25 mm dialaid in trenches for passing of LT cable complete all as specified and directed.
M&L for providing Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, cable duct, cover slab and benching including all necessary form works complete all as specified and directed.
Dismantling and Taking out old unserviceable cable junction boxes and Supply and fix thermoplastic cable junction boxes IP 55/IP 65 with metric knockout for cable entry with terminal of size 200x160x98 mm on pole with MS clamps, nut bolts, washers and glands suitable for 16 sq mm 04 core cable and all as specified and directed . Make Hansel Cat No K 9255 or equivalent in Neptune.
Dismantling and Taking out old unserviceable cable junction boxes and Supply and fixing thermoplastic cable junction boxes IP 66 "halogen free and weather proof" for outdoor Installation with metric knockout for cable entry of size139 x119x70mm fixing on pole with MS clamps, nut bolts, washers and glands suitable for 6 Sq mm 02 core cable including taking down old unserviceable cable junction boxes all as specified and directed. Make : HENSEL Cat No K-9065 or equivalent in Rittal.
S&F of automatic street light control switch using infrared sensor based NATURE SWITCH for automatic switching of street light. Three phase load of 8 KW (Swadeep-02EC8kW3P) with 3 Nos contactors, 3 Nos incoming MCB, 3 Nos Outgoing MCB of capacity of capacity 20-32 Amps each, circuit wiring (Copper) of 10 Sqmm. Nature switch operation should be based on Nature light Lux level. Required luminance level for switching ON is more than 30 Lux and for switching OFF is less than 10 Lux. The sensor should also have part night operation facility of min 4 Hrs to max 12 Hrs. The sensor along with suitable SMC enclosure confirming to IP 66. The circuit should also have provision for manual operation i.e. sensor by-pass option setting feature complete all as specified and directed. Model : Swadeep-66-8 kW3P/equivalent.
Supply and fix 2 core 2.5 sqmm PVC insulated PVC sheathed weather proof multistranded Copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting all as specified and directed. Note- GI tube shall be measured and paid separately
Supply and fix 2 core 1.5 sqmm PVC insulated PVC sheathed weather proof multistranded Copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting all as specified and directed. Note- GI tube shall be measured and paid separately
Supply and fix 15 mm dia GI tubes light grade with all fitting from looping box to street light fittings with clamps, nuts & bolts complete all as specified and as directed
Matrial and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 4 Sqmm size including dismantling of existing unserviceable cable complete all as directed
Matrial and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 6 Sqmm size including dismantling of existing unserviceable cable complete all as specified and directed
Matrial and labour for replacement of service cable of PVC insulated, unsheathed aluminium multistranded conductor twin core 10 Sqmm size including dismantling of existing unserviceable cable complete all as specified and directed
Dismantling and Taking out old unserviceable time switch and Supply and fix astro time switch for controll street light 3P module,24 hours program,with battrey back up of 100 hours complete all as specified and as directed.Legrand,L&T
Dismantling and Taking out old unserviceable contactor and Supply and fix power contactor 4 pole 240 Volts,40 Amps , coil voltage of rating 240 Volts including taking down old unserviceable power contactor all as specified and as directed by Engr-In-Charge Make;-Legrand,L&T, GE
Supply & fixing MCB TPN 32 amps of 10 KA in existing panel with incoming and outgoing connection complete all as directed Make : Legrand 4086 58 or equivalant
M&L for preparing surfaces of LT/HT electric poles of any type size including street light brackets, bracket clamps, cable protection pipe, terminal box, stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint completely including painting strips on poles with one coats of sky blue and white synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
M&L for stickering of pole No. with letters of size 25 mm height on pole/ plate complete all as specified and as directed by engineer in charge.
Dismantling and Taking out old unserviceable Garden/Pathway Light fittings and Supply, Installation, Testing and Commissioning of Integral LED Ground mounted Bollard Inverted pyramid tripod led bollard with soft 360 degree light with a system lumen output of 300 lumens and a minimum system efficency of 35 lm/W. The luminaire shall have a rated system lifetime of 25,000 buring hours at L70. The luminare should have a color temperature of 3000K and CRI>75. The luminaire shall meet IP65 & IK10 rating with THD < 20% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium with polycarbonate diffuser. The power consumption should not exceed 8W/9W (including driver) complete all as specified and directed Make:- CG Cat No.LBLSN-10-CDL or equivalant in Philips, GE
Dismantling and Taking out old unserviceable Garden/Pathway Light fittings and Supply, Installation, Testing and Commissioning of Integral LED Ground mounted Bollard Inverted led bollard with soft 360 degree light with a system lumen output of 300 lumens and a minimum system efficency of 35 lm/W. The luminaire shall have a rated system lifetime of 25,000 buring hours at L70. The luminare should have a color temperature of 3000K and CRI>75. The luminaire shall meet IP65 & IK10 rating with THD < 20% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium with polycarbonate diffuser. The power consumption should not exceed 8W/9W (including driver) complete all as specified and directed Make:- CG Cat No.LBLA3-10-CDL or equivalant in Philips, GE
Dismantling and Taking out old unserviceable street Light fittings and Supply, Installation, Testing and Commissioning of Integral LED street light luminarie 45 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 45 W and power factor 0.90 complete all as specified and directed Make CG LSTP-45-CDL or equivalant in Philips, GE
Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 135 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 135 W and power factor 0.90 complete all as specified and directed Make CG LFLN-135-CDL/60 or equivalant in Philips, GE
Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 50 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 60 W and power factor 0.90 complete all as specified and directed Make CG LFLE-50-CDL or equivalant in Philips, GE
Dismantling and Taking out old unserviceable Post Top Light fittings and Supply and fixing in replacement for Post Top latern fitting with LED Decorative indirect posttop for garden,Gate,landscape lighting. IP 65 protection.Resistant to impact and corrosion. Glare-free and better uniformilty and complete all as directed by Engineer-in-Charge Make : CG Cat No LPTO-40-CDL or equivalent Philips, GE
Supply and fixing LED Bush and spike light 9W with a system lumen output of 300 lumens and a minimum system efficency of 35 lm/W. The luminaire shall have a rated system lifetime of 25,000 buring hours at L70. The luminare should have a color temperature of 3000K and CRI>75. The luminaire shall meet IP65 & IK10 rating with THD < 20% and PF > 0.9. The luminaire housing should made of pressure die cast aluminium with polycarbonate diffuser. The power consumption should not exceed 9W (including driver) and including fixing arrengement of nut, bolt washers etc. Make:- Bajaj Cat No.BGSBL 9W LED WW or equivalant in Philips,CG.
Labour only for checking the serviceability of different spares / components / parts of roof light fittings at Urvashi hall, fittings of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and complete all as specified and directed by Engineer-in-Charge. NOTES :- (i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools etc and screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.
Supply only following materials suitable for various type of street light,roof light, security light for replacing against item no 36 here in before. Make of spares CG,Philips or equivalent
(a) CFL 26 W crass Pin Type for roof light fittings.
(b) Electronic Ballast suitable for 2x26 W CFL light fittings.
Dismantling/Taking down and Re-fixing/erecting of Old steel tubular swaged poles any type with accessories/fittings at other location as directed including necessary excavation, removal of soil, refilling of soil, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate for foundation of pole and coping with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
Taking down old unserviceable Post Top lantern fitting Supply and fixing Post Top lantern fitting with LED lamp 9 Watts opal acrylic diffuser and accessories including nut, bolt, washers all as specified and directed.
Advance Refrigeration Engineering Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .