Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹17.3 L+₹33,148 (1.96%)Rejected-AOC BLOCK 8 AND 10 GROUND FLOOR SDA COMPLEX KASUMPATI SHIMLA HIMACHAL PRADESH 171009 | SHIMLA | HIMACHAL PRADESH | 171009 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹17.9 L+₹1.0 L (5.99%)Rejected-AOC | L3 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹37,058
Closing Date
28 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE E BSNL ED1 SHIMLA
The Executive Engineer E B.S.N.L., Electrical, Division 1, First Floor, Block no. 35, SDA Complex, Kasumpati, Shimla171009
Rate Contract Comprehensive maintenance of DEA set and rectification of defects of DEA sets at various Sites under BSNL ED Shimla 1. Phase I
2021_BSNL_79749_1
07/2021-22/SHIMLA/ELECT DIVISION1
Open Tender
Electrical Works
Item Rate
720 days
SHIMLA
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
AO CASH BSNL GMTD SHIMLA
₹37,058
Yes
20 Oct 2021
16 Jun 2021
2 Jul 2021
16 Jun 2021
28 Jun 2021
16 Jun 2021
90 days
Amount
Sub Head-I ( Comprehensive Maintenanace Work )
Comprehensive Maintenance of Following DEA sets as per specification attached
15 KVA---1No.
20 KVA--1 Nos
30 KVA--1 Nos
40 KVA---1No.
50 KVA--1 Nos
Sub Head-II ( Servicing & visits, Minorrectification of DEA set works )
General Servicing of following capacity of DEA sets of different makes and models under various exchanges comprising of following jobs i/c Transportation, Labour charges & material required for servicing i/c minor material required for healthyness of DG set etc. as reqd. (i) Cleaning & greasing of the parts (ii) Tappet setting as per standard (iii) Fan belt, tensioner pulley and lever adjustments (iv) Tightening of all the nuts, bolts and clamps (v) Testing & checking of AC & DC Wiring. (vi) Self & Charging Alternator cleaning and testing, checking of working & minor fault removal. (vii) Checking of Supply & return fuel pipes from fuel tank to engine. (viii) Replacement of consumables like lub Oil, diesel filter, Oil filter, filter element of air cleaner & coolant (in case of water cooled engines) (ix) Checking of FIP timing by Fuel cut off method. (x) General servicing i/c cleaning of DG panel (xi) General servicing & complete cleaning of DG set
General Servicing of following capacity of DEA sets of different makes and models under various exchanges comprising of following jobs i/c Transportation, Labour charges & material like antifreeze lub oil etc required for servicing i/c minor material required for healthyness of DG set etc. as reqd. ( Only for Lahoul/Spiti/Kinnaur area) (i) Cleaning & greasing of the parts (ii) Tappet setting as per standard (iii) Fan belt, tensioner pulley and lever adjustments. (iv) Tightening of all the nuts, bolts and clamps (v) Testing & checking of AC & DC Wiring. (vi) Self & Charging Alternator cleaning and testing, checking of working & minor fault removal. (vii) Checking of Supply & return fuel pipes from fuel tank to engine. (viii) Replacement of consumables like lub Oil, diesel filter, Oil filter, filter element of air cleaner & coolant (in case of water cooled engines). (ix) Checking of FIP timing by Fuel cut off method. (x) General servicing i/c cleaning of DG panel (xi) General servicing & complete cleaning of DG set
Supplying of good quality Antifreeze coolant (ethylene glycol) suitable upto -40 deg Celcius ( Only for Lahoul/Spiti/Kinnaur/Pangi area)
Attending and rectification of EA 7.5 KVA to 30 KVA set faults including providing minor spares if reqd such as connecting copper wires, removing air from fuel pump, control fuse, ferrules, lugs i/c minor works etc etc alongwith testing & commissioning etc. in URBAN site complete as required.
(Item will be measured on submission of visit report duly signed by BSNL authority and allowed at once per site per fault) (Note:- For subsequent visit to attend the DG set to provide the items hereunder will not be paid separately. It is assumed that all items as below shall be carried out by firm in first visit only)
Attending and rectification of EA 7.5 KVA to 30 KVA set faults including providing minor spares if reqd such as connecting copper wires, removing air from fuel pump, control fuse, ferrules, lugs i/c minor works etc etcalongwith testing & commissioning etc. in RURAL/TRIBAL site complete as required.
(Item will be measured on submission of visit report duly signed by BSNL authority and allowed at once per site per fault) (Note:- For subsequent visit to attend the DG set to provide the items hereunder will not be paid separately. It is assumed that all items as below shall be carried out by firm in first visit only)
Sub Head-III ( Repairing Works of DEA Sets )
Providing maintenance free New Lead acid Batteries following types/rating complete with first fill of electrolyte & first charging i/c replacement of leads, nut bolts ,terminals/thimbles complete as reqd.
110 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1100 or Equivalent of a approved. Make)
130 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1300 or Equivalent of a approved. Make)
180 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1800 or Equivalent of a approved. Make)
Replacement of following defective accessories in the existing DG sets with new accessories, complete as reqd. [Dismantled defective accessories shall belong to vendor, credit for same has to be considered while quoting rates.]
Coolant.
Battery Leads (Flexible) of length not less than 0.6 Meters with terminals.
6 Sq. mm. Multi-strand Copper Cable.
Flexible wire braided fuel pipe.
Benzo Bolts.
RPM cum hour meter (mechanical) without cable.
SMPS 12 volt, 10 Amp Battery Charger i/c Transformer, Rectifier unit and Filter Circuit etc. complete as reqd.
SMPS 12 volt, 15 Amp Battery Charger
Triple Pole 32A 415 V Contactor (2NO+2NC).
6 Sq. mm. Multi-strand Copper Cable.
Flexible wire braided fuel pipe.
Triple Pole 32A 415 V Contactor (2NO+2NC).
Stop Solinoid 12 volt (Engine shut off solenoid)
Oil pressure gauge
Oil temperature meter with safety
Water temperature meter
Starting key switch
VAF meter
DC voltmeter
DC Ammeter
Auto / manual Rotary switch
Overspeed safety
Four Pole 40A (MCB type).
Four Pole 32A with side handle with SS enclosure.
3 Pole, 100A MCCB , of suitable release range ,breaking capacity 30 KA at 415V (M/s L&T DU100H or equivalent similar superior make )
4 Pole, 100A MCCB , of suitable release range ,breaking capacity 30 KA at 415V (M/s L&T DU100H or equivalent similar superior make )
SITC of Automation relay in AMF panel for following rating of DG set compatiable with all makes of EA sets complete as required (ECON-ABT model of M/S Procom or equivalent model of Similar Superior make)
15 KVA-50 KVA
Repairing of control wiring of existing AMF control panel of DEA set i/c repairing/ replacement of damaged wiring with same rating and size of Cu. Wire for effective control working complete all as required. (Without replacing of faulty parts)
Repairing & General Servicing of the existing faulty radiator in existing DEA set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, Dismantling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd.
Upto 20KVA DEA set.
Above 20KVA and upto 50KVA DEA sets
Above 50KVA and upto 250KVA DEA sets
Above 250KVA and upto 500KVA DEA sets
Repairing of control wiring of existing Conventional control panel of DEA set i/c repairing/ replacement of damaged wiring with same rating and size of Cu. Wire for effective control wiring complete all as required. (Without replacing of faulty parts)
Calibration of fuel injection (FI) pump i/c dismentalling the fuel pump, cartage to the service station and refixing the same i/c injector timing & tappet setting, testing etc. complete all as required. (Note: Pump caliberation only from authorised dealer with test report)
Up to 2 Cylinder engine(s).
Up to 4 Cylinder engine(s).
Up to 6 Cylinder engine(s).
Rewinding of the Charging alternator of the DEA set complete with testing, fixing etc. complete as required.
Repairing of 10/15/20 KVA rating, Single/Three phase, 230Volt / 415 Volt, 50Hz, 0.8 PF alternator assembled with diesel Engine i/c dismentalling the alternator, rewinding of stator and exciter, field winding and rotor assembly, reassembling with Engine after rewinding (i/c carriage to workshop for rewinding) and making proper alignment, making interconnection, testing on load etc. complete as required at site.
Stator winding.
Rotor winding.
Rewinding of excitor and field winding.
Alternator Diode assy
Alternator Rectifier assy
Repairing of 30/35/63 KVA rating, Three phase, 415 Volt, 50Hz, 0.8 PF alternator assembled with diesel Engine i/c dismentalling the alternator, rewinding of stator and exciter, field winding and rotor assembly, reassembling with Engine after rewinding (i/c carriage to workshop for rewinding) and making proper alignment, making interconnection, testing on load etc. complete as required at site.
Stator winding.
Rotor winding.
Rewinding of excitor and field winding.
Alternator Diode assy
Alternator Rectifier assy
Replacement of faulty coupling(s) with new one in following rating DEA set(s) i/c allignment, testing etc. complete as required.
Supply Installation Testing commissioning of Super capacitor based DG cranking system consisting of suitable nos. of Supercapacitors and battery cahrger. The DG cranking device shall be suitable for starting of DG sets upto 25 KVA capacity as per specification attached. (M/S Delta/ Intelux/VNT or similar superior make)
Less for old faulty DG set battery of following capacity
12 Volts 110 AH
12 Volts 130 AH
12 Volts 180 AH
GULERIA AND COMPANY
Shree Anand Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .