Tender Value
Refer Docs
Closing Date
30 Nov 2021, 2:00 pmClosed
Puneet Khanna (Director-Supply Chain Management)
WORLEY India Private Limited, New Energy House , Ramakrishna Mandir Road, Kondivita, Andheri (East),Mumbai- 400 059, India
SWITCHBOARD-M.V.MCC/PCC/PMCC
2021_REFHQ_141887_1
44AD2800-MRQ-D-46-000011
Limited
Electrical - Cables, Switchgear and Other Control Equipment
Supply
120 days
IOCL Site, Haldia, Refinery, Haldia West Bengal
Please refer Tender documents.
3 documents required · 3 mandatory
Exempted
20 May 2023
7 Oct 2021
1 Dec 2021
7 Oct 2021
30 Nov 2021
21 Oct 2021
Amount
Design, engineering, manufacturing, assembly, painting, inspection and testing, packing, forwarding & supply at site including mandatory & commissioning spares, tools & tackles (if any), supervision of installation, testing and commissioning, mechanical and performance guarantee of the following equipment 415V PMCC and 415V Bus duct as per the requirements specified. For mandatory spares, HMI IO list & Annunciation list, refer document no. 44AD2800-000-E.02-011A-A4.
415V PMCC: 2500A, 415V, 50Hz, 50kA for 1 sec., 3 phase, 4wire, Single Front for breaker feeders & Double front for SFU feeders, Compartmentalized, draw out Type, form 4B type separation, PMCC with 2 nos. incomers & 2 no. bus coupler complete with Auto transfer scheme, Metal enclosed switchboard with, Aluminium busbar, Internal Arc tested as per TR 61641-2014, full short circuit current i.e. 50kA for duration of 0.3 sec (min.) along with PRESSURE FLAP releasing Arc gases, Meters, Numerical protection relays, other auxiliary relays, indication, alarms, communication hardware/software & network switches for HMI interface, marshalling cabinet per shipping section, etc., as applicable with all necessary accessories. Protection relay parametrization & testing kits with its associated software / hardware for each type of relay shall be considered. Testing kit shall be used at site work and can be taken back by manufacturer after successful testing. Please refer drawing No. 44AD2800-000-E.01-0011-A0 for incomer and outgoing feeder details.
415V BUS DUCT: 2500A, 415V, 50Hz, 50kA for 1 sec., 3 phase, 4wire, Non - phase segregated Busduct with Aluminium Bus bar, enclosure shall be indoor / outdoor installation, Transformer and Switchgear end flexible terminations, including all horizontal and vertical bends, aluminium flexible, matching flanges, wall frame assembly, phase cross over chamber, gaskets, nuts, bolts etc. as required. (2 LOT represents bus duct system required for 2 incomers of PMCC)
Required number of breakers lifting trollies suitable for each rating. (PMCC)
Description of Work / Item(s)
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.03 OF BOQ1
Description of Work / Item(s)
CHARGES FOR SITE SUPERVISION OF ERECTION,PRE-COMMISSIONING / COMMISSIONING & TRAINING OF ALL SUPPLIES AS PER MR. Refer Annexure-F of ITB for Terms & conditions for Site Supervision Services and Training for Indian bidders.
Total 08 Mandays estimated for site Supervision of installation/ erection, testing and commissioning of instruments as listed at site as per instructions to bidder. 4 Mandays for Supervision of installation, testing and commissioning for PMCC 4 Mandays for Supervision of installation, testing and commissioning for 2 lot of bus duct
Per diem charges (per person) for 8 hours work on normal working days.
Overtime rate / hour beyond normal 8 hours work on normal working days.
Overtime rate / hour for work on weekly off days/ holidays (as applicable to Refinery site).
Description of Work / Item(s)
Schedule of rates for addition / deletion
Outgoing ACB Power feeder - 800A
Outgoing SFU Power feeder - 63A
Outgoing SFU Power feeder - 125A
Outgoing SFU Power feeder - 250A
Outgoing SFU Power feeder - 400A
Outgoing conventional DOL Starter feeder with SFU <5.5 kW
Outgoing conventional DOL Starter feeder with SFU ≥5.5kW to ≤11kW
Outgoing conventional DOL Starter feeder with SFU ≥15kW to ≤22kW
Outgoing conventional DOL Starter feeder with SFU ≥30kW to <45kW
Outgoing ACB motor Starter feeder (≥45kW to ≤160kW)
Dummy Panel for 415V PMCC
vacant module for 415V PMCC.
various 415V busduct items
Siemens Ltd
Schneider Electric India Private Limited (L&T Electrical & Automation)
Siemens Ltd
Schneider Electric India Private Limited (L&T Electrical & Automation)
Siemens Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .