Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC PO DHAN SINGH WALA GONIANA DISTT BATHINDA | GONIANA | BATHINDA | PUNJAB | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.1 L+₹55,550 (10.0%)Rejected-AOC 221 KHU WALI GALI GONIANA MANDI BATHINDA | BATHINDA | BATHINDA | PUNJAB | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.4 L+₹1.9 L (34.1%)Rejected-AOC 664 WARD NO 1 HUSSAINI ROAD NARAINGARH DISTRICT AMBALA HARYANA | L3 | Rejected-AOC L3 |
Tender Value
₹6.1 L
EMD Value
₹12,300
Closing Date
9 Feb 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr. Xen, Civil Works Division, PSTCL, Jalandhar
Room no. 301, Shakti Sadan, Jalandhar
Extension of Carrier Room Building at 132 KV S/S panjgarian.
2023_POWER_96164_1
CWJ/T-26/2022-23
Open Tender
Civil Works
Item Rate
120 days
at 132 KV S/S panjgarian.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹12,300
Yes
25 Jan 2024
4 Feb 2023
10 Feb 2023
4 Feb 2023
9 Feb 2023
4 Feb 2023
Amount
Earth work in excavation in foundations, trenches etc. In all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches , stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15 cm layers with compaction including diposal of all surplus soil as directed within a lead of 30 metres.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Dismantling brick work tile, masonry or tile lining : In cement
Dismantling concrete: Reinforced cement concrete
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Cement Concrete 1:8:16 with 40mm gauge stone aggregate.
Cement Concrete 1:6:12 with stone aggregate 40mm gauge(mixing by mechanical means using concrete mixer volumetric type)
Cement Concrete 1:2:4 with stone ballast or shingle (mixing by mechanical means using concrete mixer volumetric type)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure .
Damp proof course 7.5 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded.
Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth .
Ist class Brick work laid in 1:6 in 1st storey up to 4.00 mtr above plinth lavel i/c parapet for 4.50 mtr & 3.05 mtr slab
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level
Extra for work done in additional storey up to 4m above the top of structural roof of lower storey
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16
Bottom Khurra on ground 1.2mx0.6m consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection> 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round+B105 galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
Providing and fixing 110 mm dia SWR UPVC rain water pipe (ring fitted Type A ) as per IS : 13592 including jointing during masonary complete as per specifications and to the entire satisfication of Engineer-in-charge.(if fixed on wall face clamp to be paid separatly as per respective item)
Providing and fixing 110 mm dia SWR UPVC bend for rain water pipe as per IS : 14735 including jointing as per specifications and to the entire satisfaction of Engineer-in-charge.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ).
Providing and fixing 10mm thick acid and/or alkali resistant tiles 300 mm x 300 mm of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge, in flooring or in dado / skirting on a bed of 12 mm thick mortar 1 : 4 (1 acid proof cement: 4 coarse sand).
12.5 mm thick cement plaster 1:5
20mm thick cement plaster 1:6
12.5 mm th. Cement plaster 1:4 under ceiling
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats with anti corrosive bitumastic paint to give an even shade
Finishing walls with acrylic smooth exterior paint of required shade with two coats applied@ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish
Painting with acid proof paint of approved brand and manufacturer to give an even shade two or more coats
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings(Excluding sliding bolt)
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete: ISI designation no I (Size of door 851mm to 1000mm)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. Glazing and paneling to be paid for separately) :
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. Glazing and paneling to be paid for separately) :
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as perarchitectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts andscrews etc. complete : 250mm x 16mm
Cold twisted detormed (Ribbed/ ToR S teel Bar) Bars (Fe 500 grade as per IS 1786-1985) , for R.C.C works, where not including in the complete rate of RCC including bending and biding placing in position complete.
Providing & Fixing of 10 gauge welded mesh of 25mm x 25mm size fixed on steel glazing with MS flat 20mm x 6mm beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming Coat
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point (with fan box)
Wiring light point
Wiring 3 Pin 6 Amp. Plug control comprising wall socket (shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq.mm, 1100volts grade complete.
Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 2.5 sq.mm, 1100volts grade
PVC insulated copper conductor single core FRLS cable (ISI marked) overall 4 sq.mm, 1100volts grade
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked 2mm thick) On Surface
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 0.5-4amp. (10kA, Curve- C)
Providing and fixing 18" dia exhaust fans in switch house building
Providing and fixing electric ceiling fans with regulator complete in all respects 1400 mm sweep confirming to IS - 374 / 79 duly amended up to date.
P&F M.S Cable Racks made OF M.S Angle Iron for various size of 40x40x5 mm complete as per dwg
P & F of 20 Watt Tube set LED type Havells Make
Supply & Placinfg in positions cheqquerred plate 5 mm thicki/c cutting & grinding of edges complete in all respects
P/F steel nosing of angle 50x50x6 mm
Supplying and fixing concealed tube fitting of 2 ' x 2' with electronic chok & CFL tubes of wipro make ( Model WCP 17236 SG) of 2 X 36 W (TC-L)
Extra Carriage of materials & diff. of rates of material- Cement
Extra Carriage of materials & diff. of rates of material- Steel
Extra Carriage of materials & diff. of rates of material- Fine sand
Extra Carriage of materials & diff. of rates of material- Coarse Sand
Extra Carriage of materials & diff. of rates of material- Crushed bajri 13.2mm
Extra Carriage of materials & diff. of rates of material- Crushed bajri 11.2mm
Extra Carriage of materials & diff. of rates of material- Stone metal 40mm
Extra Carriage of materials & diff. of rates of material- Bricks
Extra Carriage of materials & diff. of rates of material- Tiles
ARANAYA BUILDCON AND ENGINEERS
RAJINDER KUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .