GARRISON ENGINEER
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
SPL REP TO BLDG NO 237 OF MH PROVN OF ONE BORE WELL NEAR BLDG NO P 881 AT AAD RECORD AND SPL REP TO POWER DISTRIBUTION NETWORK SWITCH GEAR CONNECTED ITEMS AT AAD CENTRE AT GMS UNDER GE I GOS
2025_MES_737058_1
8000/089/2025-26/0988/E8
Open Tender
Civil Works
Item Rate
180 days
GOS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER I GOS
₹90,500
28 Oct 2025
28 Oct 2025
13 Dec 2025
28 Oct 2025
11 Dec 2025
24 Nov 2025
Dismantling of floor, hearth, walls, roof tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles complete all as specified and directed.
M & L coloured vitrified tiles Light shade 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for lead free tiles in accordence with DGMS (army) letter no B/75346/Hosp Proj /DGMS-3E/01 dt 31 dec 2024 on walls as directed by engineer -in -charge .
Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories.) (Area not exceeding 2.00 sqm)
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed.
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M&L for applying two coats of oil bound distemper on wall or concrete surfaces on prepared surfaces including, rubbing with sand paper complete all as specified and directed.
M&L preparation of old painted surfaces and applying one coat of white wash but on ceiling complete all as specified and as directed.
S&F door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight between 36 to 60 Kg of aluminium (Die cast) body complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made for conditions separately ) and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing without undulations complete all as specified and directed.( Note:- All credit materials should be deposited in MES yard as available on work site the same materials should be issued to contractor through gate pass as per schedule of credit materials against contract agreement).
Material and labour for cutting chasing,pinning of brick/ stone/concrete wall at any height wall cutting and chases for concealed wiring for 25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed
Material and labour for point wiring and circuit wiring from distribution board to control switch boardwith 1.5 sqmm PVC insulated wires, FRLSH type complete incl suitable , ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 25 mm dia medium grade(MMS) and including cutting, chasing work at any height and all accessories concealed/surface(as per site) in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.20mm thick suitable for fixing of and including white/Silver/Dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colour modular plate cover of required modules and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with 3mm putty and necessary distamber for smooth finishing complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box,top cover plate, blank plate,MS box,screws,washers and all modular electrical fixtures are used same make/brand only and including cutting & chasing work at any height/places(incl stone bldgs) it shall be deemed in to included in quoted rate only.)
One light point controlled by one 10 Amps switch one way
One fan point controlled by one 10 Amps switch and one regulator.
One exhaust fan point controlled by one 10 amps switch .
One 5 pin 6 amps socket point controlled by one 10 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 10 amps switch on same board .
One bell/buzzer point controlled by one bell push.
One light point controlled by two 2 way switches/bed switch point
All as per item No. 26 & 27 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:-
One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on independent board.
One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on same board.
All as per item No. 26 above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed.
Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type bell push 10 Amps,1 module, single pole, 240 volts,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type switch 16/20 Amps, single pole,1way,1 module,240Volts, ISI Marked complete all as specified and directed.
Supply & fixing modular type socket shuttered type 10 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed.
Supply & fixing modular type socket 16/20 Amps, 6 Pin combined shuttered socket 2 module,240V,AC ISI Marked complete all as specified and directed
Supply & fixing red color lighting indication lamp switch, single pole,240volts,AC,50 Hz suitable for 1 module ISI Marked complete all as specified and directed.
Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 1 to 8 steps, ISI Marked complete all as specified and directed.
Supply and fix call bell AC, 230 Volts single pole, multi music type best and superior quality, ISI marked, as approved type complete all as specified and directed.
Supply & fix angle lamp holder latest model, insulated PVC out side body and brass inside holder with back plate for batten fittings/bulbs complete all as specified and directed.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Supply and fixing LED wall mounted security lights 30/35watts,IP-65 ProtectionSupply & fixing , in repairs LED bldg secruity light fitting of capacity 60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection and including removing of old unserviceable item complete all as specified and directed.
Supply and fixed in repairs recess mounting 2'x2' LED 40/42 Watt light fitting slimmest 9 mm thin in class LED ceiling panel with best in class aesthetick white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm mudular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting and including removing old unserviceable item complete all as specified and directed complete all as specified and directed. Note:- Old LED 2'x2' lights deposited in MES store yard for safe custody.
S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired of luminaires including LED light driver and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed.
Supply & fixing and sheet metal enclosure with acrylic door type, double door ,415 volts AC,VTPN DB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer, and MCB SPN/SP/TPN as outgoing and complete for IP43&54 DBs protection and including removing old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed.
Supply & fixing and sheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed.
Supply & fix and in repair sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 12 way for flush mounting with 100amps copper busbar,neutral bar,earth bar suitable for MCB incomer of rating upto 100Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed.
Supply & fix and MCB SPN 32 to 40 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified a
nd directed.
Supply & fix and MCB SPN 40 to 63 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed.
Supply & fix and MCB TPN 40 63 Amps 10 KA,"C" series,AC,415Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed.
M & L for sub main wiring complete with 4 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit 25 mm dia in concealed ISI marked medium grade(MMS) ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Four run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring complete in repairs with 2 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn drawn through and including PVC conduit 25 mm dia in concealed ISI marked medium grade(MMS) accessories such as Tee,corner, overlaping connector etc and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit 25 mm dia ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit 25 mm dia ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4.0 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Supply and fix mini MCB,32 A,DP 'C and motor starter including with suitable sunken box in concealed/surface and internally connected properly suitable for cooking electrical appliances including protection and including removing old unserviceable items and making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed.
Supplying and laying of CPVC /UPVC pipes SDR 11 & Plain SDR 11 incl all fittings ( bens, Tee, long bend, coupling,short pieces etc) of outer dia 32 -40 mm laying in floors/in walls /in trenches etc with clamping complete all as specified
Each Job
Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certifie. (ii)The contractor shall be arranged General (SLD), circuit lay out drawings & Switch gear items makes submitted for prior approval by the Accepting Officer/Engineer -in-charge before procurement/ordering.
Incoming:- MCCB,4 pole,415 Volts Manual drawout type with microprocessor release of capacity 400 Amps complete all as speficied and directed.-01 Nos
Outgoing :- ON-Load change over switch with front operated handle 400Amps,415Volts 4 Pole incl steel coated factory fabricated spreader links & steel nuts,bolts and washers of suitable apms rating in RYB &N.01 Nos
Outgoing:-MCCB 250 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos
MCCB 200 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos
MCCB 160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01
MCCB 63/100 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N. 01 Nos
MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCB incl spreader links of suitable ratings 01 Nos
MCCB 63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos 02 X spare compartments for MCCB incl spreader links of suitable ratings 01 Nos .
R,Y,B Phase indicating lamp -01 Set
400/5A current transformer -03 No's
Digital Voltmeter( 0Volts to 500Volts)-01 No with ASS,
Supplying and laying of CPVC /UPVC pipes SDR 11 & Plain SDR 11 incl all fittings ( bens, Tee, long bend, coupling,short pieces etc) of outer dia 32 -40 mm laying in floors/in walls /in trenches etc with clamping complete all as specified
Protection fuses& controll wiring -03 Nos
Main bus bar TPN 1000 Amps 01 Set ( 04 Nos) and out going distribution busbar size and amps rating x1.5 times rating aluminium busbar -01 Set ( 04 Nos)
Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified (ii)The contractor shall be arranged General (SLD), circuit lay out drawings & Switch gear items makes submitted for prior approval by the Accepting Officer/Engineer -in-charge before procurement/ordering. (iii) Name of LT panel Manufacturers :- M/S UTKAL Electrical Industries / M/S Girija Electricals or as approved and followed by CPRI norms/certified or equivalent approved manufacturers only.
Incoming:- MCCB 320A,4 pole,415 Volts Manual drawout type with microprocessor release of capacity 250 Amps complete all as speficied and directed.-01 Nos Make:-ABB/ Siemens/Schneider/Havells/Legrand as approved by GE.
Outgoing :- ON-Load change over switch with front operated handle 315 to 400Amps,415Volts 4 Pole incl steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos Make:-ABB/ Siemens/Schneider/Havells/Legrand
Outgoing:-MCCB 160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N 01 Nos. Make:-ABB/ Siemens/Schneider/Havells/Legrand
MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCB incl spreader links of suitable ratings 01 Nos
MCCB 63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos 02 X spare compartments for MCCB incl spreader links of suitable ratings 01 Nos .
R,Y,B Phase indicating lamp -01 Set
MCCB 125 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos
MCCB 32-63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos 02 X spare compartments for MCCB incl spreader links of suitable ratings01 Nos .
400/5A current transformer -03 No's
Digital Voltmeter( 0Volts to 500Volts)-01 No with ASS,
400/5A current transformer -03 No's
Digital Voltmeter( 0Volts to 500Volts)-01 No with ASS
Main bus bar TPN 500 Amps 01 Set ( 04 Nos) and out going distribution busbar size and amps rating x1.5 times rating aluminium busbar -01 Set ( 04 Nos)
Taking down old unsv/burnt LT panels/Feede pillar panels in any capacity and supply, install, testing and commissinoning LT panel board outdoor type with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle and shall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3.15 mm thick at outer sheet and 2.0 mm thick at internal compartments CRCA sheet and necessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should be connected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame of height 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4) type B1 with studs,bolts,nuts & washers as per site requirement. And complete all as specified and directed and including comprising of following:-
Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified. (ii)The contractor shall be arranged General (SLD), circuit lay out drawings & Switch gear items makes submitted for prior approval by the Accepting Officer/Engineer -in-charge before procurement/ordering.(iii) Name of LT panel Manufacturers :- M/S UTKAL Electrical Industries / M/S Girija Electricals or as approved and followed by CPRI norms/certified or equivalent approved manufacturers only.
Incoming:- MCCB,4 pole,415 Volts Manual drawout type with thermal based release of capacity 250 to 315 Amps complete all as speficied and directed.-01 Nos
Outgoing :- ON-Load change over switch with front operated handle 250Amps,415Volts 4 Pole incl steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos
Outgoing:-MCCB 125-160 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos
MCCB 100-125 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos
MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCB incl spreader links of suitable ratings 01 Nos
MCCB 63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos 02 X spare compartments for MCCB incl spreader links of suitable ratings 01 Nos .
R,Y,B Phase indicating lamp -01 Set
MCCB 125 Amps,4 pole, 35KA, 50Hz,415 Volts with microprocessor based release and incl providing steel coated factory fabricated spreader links & steel uts,bolts and washers of suitable apms rating in RYB &N.01 Nos
400/5A current transformer -03 No's
MCCB 63-100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-03 Nos and 01 X spare compartments for MCCB incl spreader links of suitable ratings 01 Nos
MCCB 12-63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nos 02 X spare compartments for MCCB incl spreader links of suitable ratings.01 Nos
Protection fuses& controll wiring -03 Nos
Main bus bar TPN 320 Amps 01 Set ( 04 Nos) and out going distribution busbar size and amps rating x1.5 times rating aluminium busbar -01 Set ( 04 Nos)
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 16 sqmm,4 core complete all as specified and directed.
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 25 sqmm,4 core complete all as specified and directed.
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 35 sqmm,3.5 core complete all as specified and directed.
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 50 sqmm,3.5 core complete all as specified and directed.
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 70 sqmm,3.5 core complete all as specified and directed.
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 95 sqmm,3.5 core complete all as specified and directed.
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 120 sqmm,3.5 core complete all as specified and directed.
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 185 sqmm,3.5 core complete all as specified and directed.
Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 240 sqmm,3.5 core complete all as specified and directed.
Supply and Fixing of Change over switch with encloser of capacity 250 Amp ,3 Phase ,4 Pole complete including taking out of old /burn U/S changeover.complete all as specified .
Taking down old unsv item from existing location and material and labour for earthing of machinery/equipment installed at power house/substation,using 4 mm GI wire and MS Galvanized plate of size 600x600x3 mm as earth electrode complete all as directed
Taking down old unsv item from existing location and material and labour for M& L for galvanized strip iron 25 x4 mm as earthing lead complete all as specified and directed
Taking down old unsv item from existing location and material and labour for M& L for galvanized strip iron 32 x6 mm as earthing lead complete all as specified and directed
Taking down old unsv item from existing location and material and labour for M& L for copper strip 20 x3 mm as earthing lead complete all as specified and directed
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft /loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
M & L for brick sub class 'B' 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
Material & labour for GI pipe 100 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed.
Material & labour for GI pipe 80 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed.
Material & labour for GI pipe 50 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
Taking down old unsv item from existing location and material and labour for earthing of machinery/equipment installed at power house/substation,using 32x6 mm GI strip and MS Galvanized plate of size 600x600x3 mm as earth electrode complete all as directed
M&L for Cement concrete Type D-2, 1:4:8 (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete (Nominal mix) type B-1 (1:2:4) (using 20 mm graded aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Reinforced cement concrete (Nominal mix) B-1 (1:2:4) (using 20 mm graded aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed
M&L Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finish the surfaces even and smooth without using extra cement complete all as specified and directed. Note : Liquid WPC will be measured and paid separately.
M&L for 16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
M&L for Rendering 10 mm thick in cement mortar 1 : 4 for fixing of wall tiles complete all as specified and directed.
S&F in repair aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube in opening as per specification and shown on drg SSR Part-II 2010 ,complete all as specified and directed.
S&F, factory made solid panel PVC door shutter 30mm thick (style) cons
isting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rails lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement , as per specification and shown on drawing in SSR Part-II (2010) ,complete all as specified and directed.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc ,complete all as specified and directed.
S&F 150 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed
S&F 75 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose) (Area not exceeding 2.00 sqm)
S&F 5 mm thick sheet glass ordinary quality and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed.
M&L for applying two coats of oil bound distemper on wall or concrete surfaces on prepared surfaces including, rubbing with sand paper complete all as specified and directed.
S&F 5 mm thick sheet glass ordinary quality and gazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed.
S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:- (a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls. (b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span). (d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling.
M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C-1 using 20mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising o
f one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete all as specified and directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
S&F in repair 7mm thick aluminium grills of make "Decogrill' model DG 104 surrounded by aluminium 'C' channel with mesh size 99 X 105mm all as specified and directed.
S&F in repair White vitreous china wash down water closet pan pedestal pattern (white) excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed.
S&F in repair Angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed.
S&F in repair Hand shower (Health faucet) with 1 mtr long Easy flex tube in crome finish & wall hook complete all as specified and directed.
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
S&F in repair Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position complete all as specified and directed.
S&F in repair Ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed.
S&F in repair PP-R globe or gate valves screwed both ends for PPR Pipes of 20 mm bore dia of pipe complete all as specified and directed.
S&F in repair PP-R globe or gate valves screwed both ends for PPR Pipes of 25 mm bore dia of pipe complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Bricks/ stone Masonary wall complete all as specified and directed.
S&F in repair Vitreous China urinals, half stall urinal, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including waste pipe complete all as specified and directed.
S&F in repair Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
S&F in repair Vitreous Counter sunk china WHB size 550x400 mm white flat back including PVC waste pipe but excluding taps, waste, chain & plug & porcelain stopper but including brackets with two coats of synthetic enamel painting over a coat of red oxide primer etc complete all as specified and directed.
S&F in repair Vitreous china urinal partition white of size 310 x 700 mm complete all as specifeid and directed.
S&F in repair PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and directed.
S & F in repair Brass CP Basin mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. Make Parryware , Hindware & Cera .
S&F in repair Stop valves fancy type, chromium plated 15 mm bore with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S & F in repair Liquid soap container of CP fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) complete all as specified and directed.
S&F 75mm PVC (SWR) floor trap, plain with grating,jointing with solvent cement as per site requrement all as specified and directed.
S & F in repair 125 mm dia chromium plated shower rose of with or without swivel joint incl fixing to steel pipe complete all as specified and directed.
S & F in repair sheet Glass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed.. Make Parryware , Hindware & Cera .
S & F in repair Brass chromium plated wall mixer non-telephonic shower arrangement with connecting legs & wall flanges for 15 mm bore of pipe all as specified and directed.
S&F in repair Chromoium plated Two-way angular stop cock for 15 mm bore complete all as specified and directed.
S & F in repair bottle trap chromium plated for WHB as per approved quality all as per specified and directed.
S & F in repair corner glass shelf with brackets complete all as specified and directed.
S&F in repairs plastic water closet seat cover, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair Chromoium plated Bib cock with flanges Quarter turn 15 mm bore complete all as specified and directed. Make-Jaquar , Cera & equivalent as approved by GE and Engineer in Charge.
S&F in repairs Stainless Steel Towel Rack 600 mm long with Lower Hangers but with 3 hooks complete all as specified and directed.
S & F in repair chromium plated towel ring with bracket complete all as specified and directed.
S&F LDPE pipe 50mm of pressure rating 6Kgf/sqcm fixed complete to walls, ceilings or in floors etc ,complete all as specified and directed.
Supply and laying ( inner antimicrobial ) outer UV stablized , ISI marked IS-15801,PPR Pipes , SDR 11 (PN-10) and PPR plain fittings in trenches /walls /ceiling or laying in floors complete of size outer dia 25 mm incl all fittings ,complete all as specified and directed.
Supply and Fixing PPR gate valves ( Brass insert ) of dia 25 mm ,complete all as specified and directed.
Making connections of PPR pipes distribution branches with PPR main of following size of 16 to 40 mm by providing and fixing tee incl cutting and making fusion joint etc . ,complete all as specified and directed.
M&L for Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe com plete all as specified and directed.
S&F in repair White vitreous china wash down water closet pan pedestal pattern (white) excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed.
M&L for salt glazed stoneware (SGSW) drain pipes laid in trenches of 150 mm internal diameter of pipe and jointed in CM 1:1 complete all as specifi
ed and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
tender.pdf
Tender Documents • 1.19 MB
BOQ_825274.xls
BOQ • 1.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .