Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹35.0 L+₹3.4 L (10.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹40.2 L+₹8.6 L (27.2%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹41.2 L
EMD Value
₹82,440
Closing Date
14 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major Rahul Rawat
GE (U) Bathinda
PROVN OF CERTAIN SANCTIONED MINOR WORKS, REVENUE WORKS AND LBW WORKS UNDER GE UTILITY BTD MIL STATION
2020_MES_401022_1
8517/2020-21/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (U) Bathinda
class D cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹82,440
Yes
27 Jan 2021
7 Dec 2020
16 Jan 2021
7 Dec 2020
14 Jan 2021
22 Dec 2020
60 days
Amount
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches etc. not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified.
Excavation in trenches, exceeding 1.5 m depth and not exceeding 3.00 m depth for pipe line, cable trenches etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified.
Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose)
Supply and laying best quality , locally available well burnt clay brick old size class B laid dry flat for protection over the cable, width equal to the length of cable complete all as specified.
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified. Make :- Topaz / Mehtab
Material and Labour for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of poles etc, filling and mass concrete including necessary form work complete all as specified.
Material and Labour PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in coping, foundation of poles/struts etc including necessary form work complete all as specified and directed by Engineer-in-charge.
Supply and fixing PVC insulated stranded aluminium conductor cable sheathed of Size 4 Sqmm twin core flat, 1100 volts for connection for stree light fitting with over head lines / service connection complete all as specified and directed by Engineer-in charge.
Supply and fixing of PVC insulated Copper cable stranded PVC sheathed 3 core 1.5 sqmm for connection of street light fitting from junction box/over head lines service connection complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing Rigid non matallic PVC conduit 20mm dia external inclusive of all fitting such as tees, bends, elbow, reducer, junction box etc bell mouth tube ends and all fixing accessories such as couples, bolts, nuts,saddles, pipe hooks etc complete all as specified.
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge.. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 70 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 120 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing GI tubing light grade 40 mm dia for cable protection including fitting complete with flat iron clamps size of flat iron 25mm x 4mm, nuts, bolts & washers complete fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench all as specified and directed by Engineer-in charge
Cutting of road / floor , of size 20 cm width and depth 30cm for insertation of GI Pipe including making good with existing surface complete all as directed by Engineer-in-charge. Note : (1) Note :- GI Pipe shall be mesured and paid seperately as supply and fixing in appropriate item of BoQ.
Supply and fixing Steel Tubular Single Swan Neck Pole Type 410 SP-24 (9.0 mtr long) conforming to IS - 2713 (Part - I & II) including base plate, Final taper plug, bolts,nuts and screws with two coat of aluminium paint over a coat of red oxide primer and bitumen paint of complete pole upto embedded length and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. Note:- Necessary earthwork and cement concrete work shall be measured and paid seperately in appropriate item of BoQ. .
Material and Labour Pre Stressed concrete Pole 9 Mtr long 102mm x 172 mm at top 102mm x 279 mm at bottom class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30 cm each up to 1.5 mtr height from top of PCC foundation block and numbering of poles complete all as specified and as directed by Engineer-in-Charge. (PCC for foundations and earth work shall be measured and paid for separately in appropriate item of BoQ. )
Supply and fixing Street light bracket made out of 40mm dia GI tubing medium grade made to shape 1.5 Mtr long with fixing arrangement for LED fitting duly painted with two coats of synthetic aluminium paint over a coat of primer including MS clamps and back plates fabricated from steel section including nuts, bolts, washer etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing Energy efficient LED street light fitting of 45 Watt including No. of LED bulbs as per manufacturers instructions for lighting of 45 watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for cable connection . Make Polycab Wires Pvt. Ltd (Poly Cab) Cat Part No. PUB 0506028 PCGLST1 45N or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- (i) Cable for connection of LED light fitting shall be measured and paid under appropriate item of BoQ.
Supply and fixing Energy efficient LED street light fitting of 45 Watt seasonal RTC control with dimmable type, including No. of LED bulbs as per manufacturers instructions for lighting of 45 watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for cable connection complete all as directed. Make- HALONIX CAT NO. HLSLD-ML04-45-CWL-DIM/ WIPRO LR0245W/HPL CCMSSL45W/HAVELLS CCMSLS45W/C&S INDUS-S45W/PHILIPS CCMSSL45W/CROMPTON SMARTSL45W or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- Cable for connection of LED light fitting shall be measured and paid under appropriate item of BoQ.
Supply and fixing Energy efficient LED street light fitting of 60 Watt seasonal LDR with RTC control with dimmable type, including No. of LED bulbs as per manufacturers instructions for lighting of 60 watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 110 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, with auto cut OFF above 300 V & auto switch ON normal voltage, short circuit and over voltage protection facility for Driver should be potted with electrolytic capacitor of 105 degree also with auto cut OFF above 300 V & auto switch ON normal voltage and fitting incluing making electrical connection for cable connection all as directed by Engr-in-Charge. Make HALONIX CAT NO. HLSLD-ML04-60-CWL-DIM / WIPRO LR02 60W / HPL HPL LED STCCMS2560B / HAVELLS ENDURA CCMSSL 60W / C&S INDUS-S60W/ or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- Cable for connection of LED light fitting shall be measured and paid under appropriate item of BoQ.
Supply and fixing energy efficient LED Flood light fitting of 120 Watt including No. of LED Flood light bulbs as per manufacturers instructions for light of 120 watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for connection of cable complete all as specified and directed by Engineer in charge. Make Polycab Wires Pvt. Ltd (Poly Cab) Cat Part No. PAR0206012 PCGLFT1 012057 or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- For connection of LED light fittings cable from junction box to LED light fittings shall be measured and paid seperately under appropriate item of BoQ.
Supply and fixing junction box ,size not less than 200mm x 160mm x 98mm, insulated type , made out with Polycarbonate with glass fiber reinforced. Cat Part No. KF5255 Make of Hensel / Siemens / GE Power / Rittal. Note :-1.Manufacturer should submit routine test certificate for CJB/PJB 2.The Polycarbonate Junction Box shall be environment friendly, recyclabe, UV resistant, halogen & silicon free, anti acid & anti corrosive. 3. The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529. 4.The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. 5.The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60988 - 2 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. 6. The Junction Box color according to RAL 9011. 7.The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For beter safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechnical load shall be in accordance with EN 50298 - 98 for IK 08.
Supply and fixing Pole mounted ,Hot Press Moulded SMC junction box with side Hinged door,100 % weather proof, Tamper proof, Pilferage proof, Restricts unauthorised tapping, maintenance free, fire retardant, size 250mm x 200mm x 100mm with one number MCB SP 10 Amp , 10KA 'C' series , along with and including GI clamps , nuts, bolts and washers of required size and fixed on pole complete all as manufacturers instructions and directed by Engineer - in - charge. Make Sintex Industries Limited Cat Part No.GSGB-2520 or equivlaent make and cat part as approved by GE. Note : The rate of one number MCB TPN 32 Amp , 10KA 'C' series , along and GI clamps , nuts, bolts and washers of required size is included in this item and nothing shall be paid extra on this account.
Material and Labour Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-charge. Note :- 1. The rate of one primer coat, one under coat and one finishing coat of paint is included in this item and nothing shall be paid extra on this account. 2. Payment shall be measured and paid only as per actual weight of Mild steel items. The weight of primer and paint shall not be considered duing measuerment and payment for this item.
Supply and fixing MCCB, 3 phase, 4 pole, 415 volt of capacity 63 Amp, short circuit, breaking capacity not less than 25 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .
Material and Labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4mm for pole earthing with GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I Note :- PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner
Material and Labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32mm X 6 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Material and Labour , connection ,testing and commissioning Sub main wiring with 2 single core 4 Sqmm , PVC insulated flame retardant low smoke cable with multistranded copper conductor cable ISI marked in and including 20mm dia PVC conduit medium quality conforming to 3537 Part-I & conduit accessories such as Tee , Elbow, junction box, reducer etc. with and including independent PVC insulated one single core 2.5 Sqmm flame retardant low smoke un-sheathed and multistranded copper earth wire complete all as specified. Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Two lengths of single core 4 Sqmm cable , one length of single core 2.5 Sqmm cable and 20mm dia of PVC conduit will be measured as one length) (c) Wire , PVC pipes & accessories such as Tee , Elbow, junction box, reducer etc.shall be procured from one of the manufacturer as specifed in Appendix'A' here-in- after.
Supply, installing , testing and commissioning of 1.5 Ton Split AC Inverter Type, Energy Rating 5 Star , with cordless remote control and with in built Heating and cooling arrangement , compressor Rotary with variable speed , Condensor coil Type copper, referigerant gas R32 , Enviornment friendly , with Antibacteria Filter , Indian Seasonal Energy Efficiency Ratio (ISEER) 4.20 , with inter connecting pipes and Copper pipe, insulation material, PVC clamps and water pipe as per requirement complete all as per maunfacturer instruction and direced by Engineer-in-Charge. Cat No :- Diakin copper FTXF5TV/HITACHI ACE REIDAN RAU518HTH WHITE/Voltas Copper 18H SZS White or equivalent in blue Star/ O' General Note:- Copper pipe, insulation material, PVC clamps and water pipe as per requirement will be arranged by the contractor and the cost of the same is included in this item and nothing shall be paid extra on this account.
Supply and fixing Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 150V - 285V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as per manufacturers instructions and directed by Engineer-in-Charge. Make : V-Guard Cat Part No. VND-400 or equivalent model of AE / VINTEK ELECTRONICS (VOLINA) / POWER TECH / GODREJ / VINITEC ELECTRONIC LABORATORY (VINITEC) / BLUE LINE
Supply and fix Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB up to 20 Amps, 240 volt capacity and tested on completion complete all as specified and as directed by Engineer-in-Charge. Make : Indo Asian/ Havells/ HPL/Legrand.
Supply, installation, testing and comissioning of Refrigerator capacity of 310 Litres,Frost free , Electric driven , 2 Star energy rating,Double door type , ( Single phase 230V, 50 Hz) (minimum), , 230 V including all built in accessories complete all as as per manufacturers instructions and and directed by Engineer-in-Charge. Make: Samsung / HITACHI / BLUE STAR / GODREJ / DAIKAIN / VOLTAS /LG.
Supply and fixing Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 130V - 290V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 8A complete all as per manufacturers instructions and directed by Engineer-in-Charge. Make : V-Guard / AE / VINTEK ELECTRONICS (VOLINA) / POWER TECH / GODREJ / VINITEC ELECTRONIC LABORATORY (VINITEC) / BLUE LINE
Supply, installing, testing and commissioning of water cooler full stainless steel body, electric driven (single phase 230V, 50 Hz) having approx storage capacity of 80 ltr and normal cooling capacity of 40 ltr per hrs complete all as per manufacturers instructions and directed by Engineer-in-Charge.. MODEL - SDL X 480 OF BLUE STAR OR EQUIVLANT MODEL OF MAKE VOLTAS / HITACHI / USHA SHRIRAM
Supply and Fixing Gun metal globe or gate valve size of 20 mm bore pipe , with iron wheel head, screwed both ends for iron pipe conform to IS 778 - 1984 complete all as specified
Supply and Fixing Gun metal globe or gate valve size of 25 mm bore pipe , with iron wheel head, screwed both ends for iron pipe conform to IS 778 - 1984 complete all as specified
Supply and fixing steel tubular swaged pole Single type 410 SP-55 (11 mtr long) conforming to IS - 2713 (Part - I & II) including base plate, Final taper plug, bolts,nuts and screws with two coat of aluminium paint over a coat of red oxide primer and bitumen paint of complete pole upto embedded length and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. Note:- Necessary earthwork and cement concrete work shall be measured and paid seperately in respective items of schedule.
Supply installation. Commisioning and testing LT junction box, Polycarbonate CPRI approved OEM shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES OF SIZE 60cm x 40cm x 30 cm, 415 V which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive, Degree of protection against mechaincal load shouild be IK-08 (5 Joule) in accordance with IEC, 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out a Polycarbonate thermoplastic panel in accordance with IEC 60439 -1. The CPRI report shall have mention of following tests performed and passed out satisfactorily : Temperature Rise, Dielectric Properties, Short circuit withstand current - Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test report for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warrantee certificates will be accepted only from original manufacturer. The panel should pass glow wire test 960oC in accordance with 60695-2 -11 flame retardant and self-exitinguising. Make - 'Hensel Electric/Rittal/ L&T/Schnieder. The panel drawing should be need approval. After installation it should be varified by company person. Suitable for AIuminium 200Amp Bus Bar and cable size up to 95 Sqmm mounted on angle iron legs of 25mm x 25mm x 5mm frame and legs duly spray painted internally and externally with two coats of synthetic enmel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) TYPE B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incoming/outgoing cables and testing complete all as directed by Engineer-in-Charge.
Supply, installation, commissioning and testing of diesel engine driven, water cooled, electrical start silent Generating Set 62.5 KVA capacity, liquid cooled, turbo charged with after cooler, developing 80.1 bhp @ 1500 RPM, 4 valve per cylinder, electric start, compressor ignition, 4 stroke engine designed to run continuously at 1500 RPM confirming to time rating ISO-3046/BS5514 standard with an overload capacity of 10% for one hour in every 12 hrs of operation, diesel forms to present CPCB norms complete including common base plate, floor mounted , factory assembled complete fitted in and including acoustic enclosure (sound proof canopy of suitable capacity or size) alongwith standard manual panel approved by National Physical laboratory with inbuilt standard panel, in built fuel tank suitable capacity for 12 hrs running at full load continues running, with fuel lines of heavy duty MS pipe duly painted, including PCC foundation / platform for generating set as per manufacture's instructions / conforming with drawing complete as specified and comprising with and including the following :- a) Flywheel with starter ring for generating set. b) Air filter. c) Lub oil cooler assembly with accessories. d) Exhaust air manifold. e) Expansion bellow. f) Fuel filter. g) Lube oil filter. h) Exhaust gas turbo charger with after cooler. i) Radiator with pusher type fan, with fan guard, coolant pump.
j) 12 V electrical starting system with starter motor and battery charging alternator. k) In-line monoblock fuel injection pump with electronic governing & Iscchoronus capability. l) Bore x stroke - 108x 133 mm.m) Engine cubic capacity - 3.66 ltrs. n) Engine mounting supports. o) Engine control panel - microprocessor based controller model. p) Engine safeties, alarms and trips. q) K cool super plus corrosion inhibitor coolant for cooling. r) Engine operator/ maintenance & spare parts CD. s) Engine warranty certificate and test cerificate. (A) Alternator : Same make of DG Set Engine Alternator rated at 62.5 KVA, 415 volts, 3 phase, 4 wire, 0.8 p.f. (lag), 50 Hz, 1500 RPM, in accordance with IS 4722 as per following specifcations : i) Type : Salient poles, single bearing, Brushless type, suitable for direct coupling engine. ii) Rating : Guaranteed to deliver reqiured output at the ambient temperature conditions of Bathinda. Suitable for an over load of 10 % for 1 hour in every 12 hour of operation. iii) Voltage regulation : Provided with fast response thyristor type electronic automatic voltage regulator, which holds output voltage within desired limits.(+/-1%). iv) Excitation : Self excited self regulated. v) Alternator loading : Suitable for taking rated load immediately after machine reaches rated voltage and speed. vi) Equipped with AREP ( Auxilary regulation Exiting Principle) winding to give performance equivalent to PMG as standard scope of supply. vii) Vibration: Suitable for direct coupling with Engine and mounted on common fabricated sheet metal base frame. viii) Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. ix) Cooling: Air Cooled type with radial fan mounted on Rotor. x) Winding and Insulation: Insulation class H as defined in IS – 4722.
(B) Diesel Engine Adequate capacity of diesel Engine of suitable BHP to give out put of 62.5 KVA by alternator , liquid cooled to drive independently above alternator and after considering duration as per site conditions generating and reducing power consumed by accessories. Directly coupled through flexible coupling multi-cylinder , multi stroke direct injection , cold starting 1500 RPM as per with an overload capacity of 10% for one hour in any 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation. Note : Paid voucher for the complete DG set shall be from the same OEM only. (C) ESSENTIAL ACCESSORIES Following set of essential accessories are supplied with each DG set:- i) One No. MS Base Frame suitable for mounting of the offered engine and alternator. ii) One No. fuel tank of standard capacity 150 litres complete fuel gauge, inlet/outlet connections, drains plug,etc. iii) 12, 88 Ah Volts DC Battery of suitable capacity with leads. iv) 1 Set of AVM Pads fitted in Base Frame. v) All above accessories are housed in acoustic enclosure
(D) CONTROL PANEL The Control Panel body shall be fabricated out of 16 SWG MS sheet. Panel shall be suitable for inside Canopy mounting, indoor installation, Copper Control cable of suitable size and required length shall be used. Cables are ferruled for proper maintenance/checking/wiring of panel. Detachable cable gland plates are provided. The panel shall be equipped as follows: i) One No. Moulded Case Circuit Breaker of suitable capacity. ii) Aluminium Bus Bars of suitable capacity provided with termination. iii) 3 Nos. Current Transformers of suitable ratio. iv) One set of instrument MCB’S. (E) Civil Works. : - All civil works related to foundation, installation of panel and equipments including making good of existing structure if disturbed during installation and commissioning of Gen Set . NOTE : (i) PCC for foundation of DG Set including excavation and earth work as per manufacturers standards drawing and the rate of this aspect is included in the quoted rate. (ii) Necessary testing of DG set as specifed in Particular specifications here-in-after shall be carried out by the contractor to the entire satisfaction of the Accepting Officer or any person authorised by him and the satisfactory results shall be kept in MES records duly signed by the Contractor, (iii) DHPP for the test will be arranged by the contractor on his own cost. (iv) Supply and fix Acoustic Enclosure factory made floor mounted factory built modular in construction for Engine and Alternator consisting Acoustic panels of tubular / angular in section fabricated out of 16 SWG cold rolled steel sheet packed with 1.5 mm PVC film with 25mm thick PU foam of appropriate density so as to reduce noise level 75 db measured from a distance of 1 metre from enclosure as per the norms of pollution control board suitable for 62.5 KVA Diesel Generating set approved by OEM Makeof Accoustic enclosure shall be as per OEM's Recommendation (iv) All drawings related to DG Set, AMF Panel, LT Panel shall be approved from Accepting officer before placing the order. (F) AMF Panel : Supply, install, test and commissioning outdoor type of automatic on mains failure type with necessary relays for automatic starting on mains failure type factory made as per manufacturing design and specifications - 01 Nos
Material and Labour for Earthing complete with galvanized steel earth plate electode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanised earth strip of size 32mm x 6mm (up to 7.5m in length from earth plate) by means of bolts , nuts , check nuts and washers of galvanized iron or steel all as specifed and shown in electrical plate No 3 of SSR Part - I including necessary excavation and earth work in any type of soil , PCC 1:3:6 Type CI using 20mm graded crushed stone aggregates ,chamber with RCC 1:2:4 Type B1 using 20mm crushed stone aggregates 100mm thick cover Providing with TMT 8mm dia bars with 150mm c/c reinforcement, watering funnel, 40mm dia light grade pipe for protection of earth electode and 50mm dia meidium grade pipe for watering complete all as specified and directed and tested on completion. Note :- PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner
Supply, fabricating, installation, testing , commissioning and electrically connecting LT junction box cubical type of size 60cm x 40cm x 30 cm,415 volts ,factory made , machine pressed , dust and vermin proof , out door type , made with CRCA sheet 3.15 mm thick , Junction Box shall be powder coated with 7 tank process for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish. , Front opening with single door with provision of rubber beading and locking system , including aluminium bus bar size 30 mm wide and 6 mm thick 4 strip of with provision of hole on bus bar for fixing of cable mounted on PVC / epoxy insulators, mounted on angle iron legs frame made with angle iron size 25mm x25mm x 5mm and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded crushed stone aggregate) including necessay earth work complete , including all provision of opening for incomming/outgoing cables and testing complete all as directed by Engineer-in Charge.
Aman Enterprises
SHARDA ENTERPRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .