Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC 25 SIRAJ DULA SARANI KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L1 | Accepted-AOC Stands Lowest | |
| 2 | L2₹5.2 L+₹32,921 (6.73%)Rejected-AOC VILL GOPINATHPUR P O NAKOLE P S SHYAMPUR DIST HOWRAH | HOWRAH | HOWRAH | WEST BENGAL | L2 | Rejected-AOC Stands 2nd Lowest | |
| 3 | L3₹5.4 L+₹49,182 (10.0%)Rejected-Finance 2 SURI LANE GROUND FLOOR KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance Stands 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹12,509
Closing Date
18 Jun 2022, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Office of the Executive Engineer, Purba Medinipur Electrical Division, P.W.Dte, Tamluk, Hospital More
Construction of roadside electrical installation work for street light at Panskurah Fire Station under WBFES.
2022_WBPWD_383277_1
WBPWD/EE/PMED/eNIQ-06/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Tamluk
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,509
Tamluk
11 Jul 2022
1 Jun 2022
20 Jun 2022
1 Jun 2022
18 Jun 2022
7 Jun 2022
6 Jun 2022
S&F 415V TPN SFU with sheet steel encl. on flat iron frame on wall with nuts bolts etc. incl. S&F 3nos. DIN type HRC fuse as per rating. (Make- L&T) 32A TPN SFU.
Supply & Delivery of 1.1 KV grade 4 core 06 sqmm XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith. [Make: Havells/RR Kabel /Gloster/Polycab]
Laying of 1.1 KV Gr. 4 core 06 sqmm XLPE/ PVC Armoured Al Cable(multi stranded) on surface with earthing attachment in 2x10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as per GS.
Laying of one No. 1.1 KV Gr. 4 core 06 sqmm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 4 core 06 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : For 4 core 06 sqmm
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes. 13mm dia 3mm thick Polythene Pipe
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Finolex/ Havells/ RR Kabel/ Polycab) of 3x22/0.3(1.5sqmm) as ECC in the prelaid polythene pipe and making necy. connection as required [From pole loop box to LED fittings ]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/ Havells/ RR Kabel/ Polycab) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 4 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC [From panel/VTPN to Timer Switch]
Supplying & Fixing of time sensor switch consisting of the following accessories: A) 25 A FP MCB , C-Curve of breaking capacity 10 KA - 01 no. (Make: Legrand), B) 24 hour digital timer switch (Legrand: 412631)- 01 no., C) 240 V FP, 40A power contactor (Legrand: 416426)- 01 no., D) Auto manual toggle switch- 01 no., E) LED indicator lamp- 01 no. Red & 01 no. Green in (2+16) way SPN MCB DB concealed in wall /Surface on wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire & provision for earthing attachment. (For compound light control)
Supply & delivery of 07 Mtr long HDG Octagonal Pole (Make:- Bajaj /Jindal/Utkarsh/ Transrail) with 4 terminal 40A Cu terminals with 6A SP MCB, 10KA & C characteristics, to be fixed in the loop box inside the pole. Pole dimension will be : Bottom section dia 130mm, Top section dia 70mm, Sheet thickness 3mm with fixing the base plate of size (225mm x 225mm x 16 mm) incl. Foundation accessories (4 nos M20-700mm length).
S&F 48-50 mm. outer dia, 1.0 mtr. long detachable type G.I. Single arm bracket with 100mm dia 20" (Inch) long G.I. OD Pipe incl. necessary flange, nut bolt etc as required (Suitable for Octagonal 70mm dia pole head). The arm bracket shall be properly welded with 15 mm. thick stiffer plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. (Make:- Bajaj /Jindal/Utkarsh/ Transrail)
S&F 48-50 mm. dia 1.0 mtr. long detachable type G.I. Double arm bracket with 100mm dia 20" (Inch) long G.I. OD Pipe incl. necessary flange, nut bolt etc as required (Suitable for Octagona 70mm dia pole head). The arm bracket shall be properly welded with 15 mm. thick stiffer plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. (Make:- Bajaj /Jindal/Utkarsh/ Transrail)
Erection of HDG Octagonal pole muffing with cement concrete square foundation made with stone chips, PCC-100mm (1:3:6) of base block RCC (1:1.5:3), size (0.609x0.609x0.461mtr) below ground level. And upper portion size 0.406x 0.406x 1.22mtr. The hole concrete foundation made with 10mm dia. TMT Bar 0.15mtr apart (Horizontally & vertically) cage structure. The muffing should be 0.304mtr above the ground level incl. 1.5 mm thick neat cement finish up to 0.762mtr. from top level. 04 nos. 20/25mm dia 1.67mtr length GI FDN Bolts with Nuts Inside the muffing with 10mm thick base plate by welding acordingly matching with the HDG pole base plate hole. incl. 02nos. 30mm dia polythene pipe inside the center of muffing for passing 02nos cables.
SITC of road lighting luminaire ( IP 65 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system, 10KV SPD, THD < 10%, PF> 0.95, BIS approved silicon filled potted driver, minimum LPW: 110 lumen/w and minimum system output 11500 lumen suitable for use with 230Volt, 50Hz. (Make: Philips/ Crompton/ Havells/ Wipro)
Earthing with 50 mm dia GI pipe[ISI Medium,Make- ZINDAL/BANSAL] 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
Connecting the equipments to earth busbar including S & F No.4 SWG GI (Hot Dip) wire of size on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as per GS
Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil.
Supply & Fixing medium guage 40 mm Dia GI Pipe (ISI-M) for protection with necy fittings & jointing materials
Supplying and Fixing water proof looping cable box having hinged Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc as per GS. (200 x 150 x 100mm) (for LED Glow sign board)
Supplying and fixing 20mm dia PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. Terms and condition 1. The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. 2. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules. 3. Working agency has to submit the as-built drawing right from the main switch to sub panels/PDBs/load-end in both hard copy & soft copy(CAD) format & 3 sets of still photogrphs of the completed works including the submission of test certificates of the following tests duly signed by the Authorised legal Supervisor of the concerned Agency in compliance to IEE regulation & IS 732-2019. i) Insulation Resistance Test of cable and wire w.r.t the Earth. ii) Continuity test of cable & wire. iii) Polarity test of single pole switch. iv) Earth resistance test of earth electrode by calibrated IR testing kit.
Netaji Engineers CO-Operative Society Ltd.
MAHESWAR ELECTRICAL INDUSTRIES
technical_749106.pdf
PDF • 0.23 MB
techsummary_749106.pdf
PDF • 0.02 MB
finance_749106.pdf
PDF • 0.27 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_749106.pdf
PDF • 0.30 MB
FWO.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .