Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 LAccepted-Finance | 1 | Accepted-Finance Ist lowest | |
| 2 | 2₹2.0 L+₹11,602 (6.14%)Accepted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | 2 | Accepted-Finance IInd lowest | |
| 3 | 3₹2.0 L+₹12,100 (6.41%)Accepted-Finance 58 KAILASHPURAM GOVINDPURAM GAZIABAD | GHAZIABAD | UTTAR PRADESH | 3 | Accepted-Finance IIIrd lowest |
Tender Value
₹1.9 L
EMD Value
₹2,000
Closing Date
28 Nov 2023, 1:00 pmClosed
EE ETD-II Moradabad
Office of the Executive Engineer, ETD-II, 400 KV S/S Majohola premises, Moradabad
Work of complete overhauling and Replacement work of Defective Vacuum Interrupter at 220/132 KV S/S Moradabad Under ETD-II, Moradabad.
2023_UPTCL_863488_1
06/ETD-II(M)/2023-24
Open Tender
Electrical Works
Fixed-rate
60 days
Moradabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD-II Moradabad
₹2,000
28 Nov 2023
20 Nov 2023
28 Nov 2023
20 Nov 2023
28 Nov 2023
20 Nov 2023
Amount
Complete Overhauling and replacement work of 03 No damaged vacuum interrupter, provided by contractor at his own cost of following 33 KV VCB at 220/132 KV S/S Moradabad under ETD-II, Moradabad. 33 KV VCB (Shreem , ABB Make) Circuit Breaker of feeder by doing following work in above circuit breaker :- (i) Cleaning of Porcelain of drive insulator and porcelain of vacuum interrupter of each pole. (ii) Checking & adjustment of snatch gap, travel of drive insulator rod & toe rod of each pole. (ii) Opening, repairing of mechanism by welding, drilling, machning and filling of material as per requirement and proper fitting of it in breaker cubicle. (iv) Oiling & greasing of crank gears by opening of lock circlip etc. (v) Replacement of worn out parts such as bush, ring, lock pins and latch etc. (vi) Cheking & adjustement of oil daspot of breaker for its damping action. (vii) Replacement of defective vacuum interrupter, provided by contractor at his own cost. After repairing & Overhauling of above VCB, following tests are to be crried out: (i) Opening & closing time of breaker of each pole. (ii) Carrying out Contact resistance Measurement (CRM test) of each pole. (iii) Checking of megger values of breaker poles. (iv) Checking triping of breaker at 70% DC voltage. (v) Checking the Close/Open operation of breaker from remote & Local.(vi) Prepare asnd submit the site overhauling report of above circuit breaker.
Dismantling of Damaged 33 KV VCB and erection of allready repaired 33 KV VCB.
P&H Engineering
SARASWAT ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .