| 1 | L1₹23.9 LAccepted-AOC 6 GURU GOBIND SINGH NAGAR DHAKOLI DHAKOLI PATIALA PUNJAB 140602 | PATIALA | PUNJAB | 140602 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹25.3 L+₹1.4 L (5.99%)Rejected-Finance BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹26.0 L+₹2.1 L (8.99%)Rejected-Finance | L3 | Rejected-Finance Being not a lowest | |
| 4 | L4₹26.4 L+₹2.5 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Being not a lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
REPAIRS TO ROOF ROOF SHEETING ROOF TREATMENT AND CONNECTED ITEMS UNDER AGE BR-II OF GE (WEST) PATHANKOT
2022_MES_529398_1
GE/PKT-14/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹50,000
Yes
27 Aug 2022
8 Jun 2022
20 Jul 2022
8 Jun 2022
19 Jul 2022
23 Jun 2022
9 Jun 2022 - 17 Jun 2022
Amount
Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed.
Taking up or down 20 mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed.
S & F of 15mm bore Steel water tubing 'medium grade', galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F of 20 mm bore Steel water tubing 'medium grade', galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Re-fixing 15mm bore old steel water tubing with all new GI fittings etc in new or old position (Walls, ceiling, floors, etc) complete all as specified and directed.
Re-fixing 20 mm bore old steel water tubing with all new GI fittings etc in new or old position (Walls, ceiling, floors, etc) complete all as specified and directed.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings or PVC sheet in roof including ridges, sunshades or any position etc complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering from sunshades etc complete all as specified and directed.
S&F of 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L type or J type or cranked hook bolts or coach screws etc and washers, in roofs, walls etc with grade of zinc coating 275, complete all as specified and directed
All as per srl item No. 10.00 here-in-before but except sheeting, any thickness complete all as specified and directed
S & F of plain galvanised mild steel sheeting 0.80 mm thick, in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
S & F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in sunshades ,roof covering, cladding to wall etc fixed with self tapping screws complete all as specified and directed.
S & F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall and as in ridge etc fixed with self-tapping screws complete all as specified and directed.
M&L for 6 mm thick fibre cement corrugated or semi-corrugated sheet in roofs fixed with ‘L’ type or ‘J’ type or cranked hook bolts, complete all as specified and directed.
All as per serial item No.15 here-in-before but except sheets.
M&L for 6mm thick fiber cement two piece adjustable serrated ridge suitable for corrugated or semi corrugated sheets in roofs fixed with ‘L’ type or ‘J’ type or cranked hook bolts, complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for including grills, door, truss, gate, rafters, purlins etc complete all as specified and directed.
Dismantling timber scantlings 40sqcm and over in section, in any position as in wooden trusses in framed work of any description complete all as specified and directed.
S &F of Rolled structural mild steel any type hollow section as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters and rails and guides for sliding doors; and supports to roof covering, sun-shades,vertical poles etc fixed with angle cleats or other connecting plates Fe-410-W(Gde-E-250) quality B complete all as specified and directed.
S & F of mild steel work in tubular trusses (framed) /rectangular hollow section, purlines and fastening including distance pieces etc. including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed.
S & F of framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including all quions, wall, arches, pillars, man-holes, drain etc complete all as specified and directed.
M & L for burnt clay brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and directed.
All as per srl item No 25 above but on other than fair faces
M & L for preparation of newly plastered surfaces of wall and applying two coats of Cement Base Paint over and including one coat of alkali resistant priming paint complete all as specified and directed.
Demolition of existing roof treatment of any description such as worm out tarfelt, mortar of any description & any thickness, shrubs/roots ,vegetation, tree, terracing pcc/brick tiles, concrete bedding etc as directed and Cleaning of all foreign material debris etc by brushing and dusting, washing down with water etc ,surface shall be leveled with a layer of 20 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer's instructions and applying roof treatment with 03mm thick APP modified membrane with non-woven polyster reinforcement(center core) with thermal insulation with plane finish on upper side of weight not less than 3.5 kg/sqm , laid by torch application method with overlap 100 mm on length side and 100 mm on the width side as per manufacturer's instructions over one coat of approved cold applied bituminous oil based primer (IS-3384) @0.30 litre/sqm complete all as specified and directed
M&L for preparation of newly steel and iron surface of any description width or girth exc 10 cm and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description over 10 centimeter width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F in repair for PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair for PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair for PVC (SWR) bends ISI marked any radius 75mm dia complete all as spd and directed.
S&F in repair for PVC (SWR) bends ISI marked any radius 110mm dia complete all as spd and directed.
Disconnecting existing tanks (PVC/RCC) of capacity exc 250 & not exc 500 liters, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position & Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
S & F of Rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old PVC/RCC water tanks complete all as specified and directed.
S & F of Rotational moulded polyethylene water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old PVC/RCC water tanks complete all as specified and directed.
S & F in repair Ball valves 20mm bore high pressure of PTMT with epoxy coated aluminum rod & high-density plastic bal screwed for iron pipe & fixed (min. weight 20mm-210 gms) complete all as specified and directed.
S & F in repair for gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and as directed.
Supply only liquid water proofing compound all as specified and as directed.
M & L for repairing to chajjas, roof projection and facias of exposed reinforcement surface or damaged loose RCC surface including cutting down rusted/exposed reinforcement and applying one coat of cement slurry and filling with cement concrete 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) and finished with cement mortar 1:3 using coarse sand. Thickness of RCC member not exc 150 mm including scaffolding up to 8.0m height complete all as specified and as directed . Note : No extra rates of scafffolding will be paid separately against this item.
M&L for Dismantling of wall and ceiling boards (fibre, plup, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed.
S & F of anodised aluminium snap grid frame work for suspended false ceiling system, grid section size 600mm x 600mm comprising of GI powder coated Main 'T'(Runner) of dimensions 25mm x 35mm x 0.7mm thick (suspended from the soffit @1200mm c/c with level clip) Cross Tee of dimensions 25mmx35mmx0.7mm thick (inserted fixed into the slots of cross "T" @ 600mm to form a grid of 600 x 600 mm) and wall angle 25mmx25mmx 0.7mm thick with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed textured designer board to be placed in the grid system duly suspended with 4mm dia GI bar hangers (@ 1200mm c/c to hold the main "T") fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip) hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as specified and directed
M&L for fixing in repair for asbestos cement plain building boards fixed or laid/ inserted to timber/GI/Alumi nium/iron framework with screws complete all as specified and directed.
Demolition of cement concrete or lime concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified .
M&L for 75mm thick plain Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection, apron, path and paving finished even and fair complete all as specified and directed.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 95,475.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
GANDOTRA CONSTRUCTION CO
OMKAR SHARMA AND CO
M/S S KUMAR & CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .