Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹12.6 L+₹19,393.75 (1.56%)Rejected-Finance FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹13.0 L+₹55,492.75 (4.46%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹13.2 L+₹75,375.25 (6.06%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹14.2 L
EMD Value
₹28,400
Closing Date
6 Mar 2020, 6:00 pmClosed
SH M V SANKAR SE
CWE NAVY VASCO VASCO DA GAMA GOA 403802
ADDITIONAL ALTERNATION AND IMPROVEMENT TO BUILDING NO T 17 AT BOAT POOL INS MANDOVI UNDER AGE I MANDOVI
2020_MES_317980_1
85224/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
AGE I MANDOVI
₹28,400
Yes
5 May 2020
24 Jan 2020
9 Mar 2020
24 Jan 2020
6 Mar 2020
14 Feb 2020
Amount
Schedule 'A' -Part I (B/R Works)
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and leveled all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalent) on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating (Dr. Fixint New coat/ Waterseal Concentrate of M/s Krishna Conchem Products) without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
M&L for providing 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement all as specified and as directed. Note :- Integral water proofing compound will be measured and paid separately
Supply only integral water proofing compound
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
Dismantling plain or corrugated steel sheeting any description not otherwise provided for all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290(Gde E-165) all as specified and as directed.
M&L for preparation of new or previously untreated steel surfaces & apply two coat of synthetic paint over one coat of red oxide primer . Surfaces of any description, exceeding 10 cm in width or girth when unconnected with other painting or when painted in a different tint all as specified and as directed.
Taking down cement plaster of stone /PCC block /brick wall / top of chajja, or concrete surface of any description including raking out joints hacking for key securing down with water etc and removal of debris to outside of INS mandovi area including filling of open joints in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finish even & smooth with using extra cement all as specified and as directed.
M & L for 15 mm thick (10+5) rendering in cement mortar 1:4 on fair faces of brick work or concrete surface with using WPC as per manufacturer instructions and finished surface even and smooth without using extra cement complete all as specified and directed Note - water proofing liquid shall be measured and paid separately
Supply only water proofing liquid.
M & L for 5mm thick plastering in cement mortar 1:3 finished even & smooth, without using extra cement on ceiling all as specified and as directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash all as specified and as directed.
M&L for applying two coats of anti fungal weather proof paint over a coat of primer on newly plastered surfaces including preparation of surfaces all as specified and as directed.
M&L for preparation of newly plastered surfaces preparatory to distempering, Priming plastered and other surfaces with alkali resistant priming paint, 1mm thick wall care putty & distempering walls with two coats of distemper oil emulsion, white or tinted all as specified and as directed.
M&L for preparing old plastered surfaces of ceiling and applying three coats of white wash all as specified and as directed.
M&L for complete removal of existing treatment for preparation of old plastered surfaces preparatory to distempering, Priming plastered and other surfaces with alkali resistant priming paint, 1mm thick wall care putty & distempering walls with two coats of distemper oil emulsion, white or tinted all as specified and as directed.
M&L for applying one coat of acrylic emulsion exterior paint (Anti fungal paint-APEX) on old decorative surface of wall, ceiling cornices including preparation of surfaces by brooming scrapping down dust particle, smoke soot, moulds, moss and efflorescent salts etc and making surface smooth by applying ready mix putty where required all as specified and as directed.
Dismantling water tanks and removing to store exceeding 250 ltr but not exceeding 500 ltr all as specified and as directed.
S&F 500 Litre capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I all as specified and as directed.
S&F Ball valves 25mm bore dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipeand fixed in repairs . (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm- 690 gms) all as specified and as directed.
S&F 25 mm bore CPVC ball valve all as specified and as directed.
S&F 25 mm CPVC tank adaptor all as specified and as directed.
Taking down steel tubing and connections 15 mm bore all as specified and as directed.
Taking down steel tubing and connections 20 mm bore all as specified and as directed.
S & F CPVC 20 mm pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
S & F CPVC 25 mm pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
S & F Venetian blinds made of approved type fibre cloth blinds, including powder coated aluminium sliding tracks of standard medium weight sections and ceramic rollers complete all as specified and as directed
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in Soft/disintegrated rock all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m, depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
M&L for broken stone boulder hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and as directed.
M & L for cement concrete 100 mm thick in floors type B- 2 , 1 :2:4 using 40mm graded stone aggregate all as specified and as directed.
S&F Plastic dividing strips 1.5 mm thick and width of strip 38 mm all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and as directed.
M & L for precast PCC 1:3:6 type C1 using 20 mm graded stone aggregate block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 all as specified and as directed.
M&L for 15 mm thick in cement mortar 1:4 screed bed or bedding layer of mortar for laying floor finishes all as specified and as directed.
M&L for non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on vertical surface as back coat for tiling all as specified and as directed.
M&L for glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade of tiles all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls all as specified and as directed.
M&L in repairs for 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed.
S&F 75 mm bore, PVC (SWR) bends of any radius all as specified and as directed.
S & F Plastic seat cover for EWC closed pattern , flat bottom with MS chromium plated hinging device all as specified and as directed.
S & F 160 mm dia PVC (SWR) pipe with single socketed in any length solvent cement jointed fixed to wall/column all as specified and as directed.
Schedule 'A' -Part II (INTERNAL ELECTRIFICATION)
Taking down carefully copper / aluminium point wiring ( light, fan ,socket or power) complete including fitting and fixture such as switches, ceiling roses, pendants,regulators, socket, light fitting etc removing material to store for keeping in safe custody or for taking credit ( credit for above item should be made as as per condition separately) and making good disturbed surface of walls, floors etc complete all as specified and as directed.
Taking down DB TPN, main switch, sheet metal enclosure all as specified and as directed.
Taking down sub main wiring aluminium/ copper of any size including earth continuity conductor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M & L for point wiring of one light point controlled by one switch with cable 1.5 sq mm copper cable in multi stranded unsheathed through concealed in wall with PVC conduit with all accessories including 1.5 sq mm cable conductor for earth wire including making connection with common earth earth dolly including pressed steel terminal boxes firmly fixed with pipe /wall and 3mm thick Hylem sheet or plastic masonite laminated sheet top cover fixed with brass screw for mounting switches sockets regulator etc all as specified and as directed.
All as per Item No 50 here in before but for ceiling/exhaust Fan all as specified and as directed.
All as per Item No 50 here in before but for switch socket combination 3 pin 5 amps on independent board all as specified and as directed.
All as per Item No 50 here in before but for 2.5 sq.mm pvc insulated and unsheathed copper conductor for switch socket combination 3 pin 15 amps on independent board all as specified and as directed.
S&F Modular switch one way 6 amp, 1 module 230V, 50Hz AC supply all as specified and as directed.
S&F Sheet metal enclosure double door DB SPN 8 way 230 volts 50 Hz IP-42 protection all as specified and as directed.
S&F Modular switch one way 16 amp, 1 module 230V 50Hz AC supply all as specified and as directed.
S&F Modular socket 6A-2/3 pin 2 module, 230 volt 50 HZ AC supply all as specified and as directed.
S&F Modular socket 6A/16A-2/3 pin 2 module, 230 volt 50 HZ AC supply all as specified and as directed.
S&F Modular fan step regulator 120 watt 2 module all as specified and as directed.
S&F LED tube light fitting 1 X 20 watt baton T5 CLASSIC integrated LED channel integral sleek extruded polycarbonate LED channel with white acrylic cover along with LED tube ROD 01 No including flexible wire three core from existing ceiling rose to fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and as directed
S & F Exhaust fan 300 mm sweep with louvers complete with suitable MS Bracket, nuts, bolts and fixing arrangement single phase 230/240volt AC supply 50 HZ including making holes and PCC work and including Taking down old u/s Exhaust fan of any size from the existing location and deposit to MES store yard all as specified and as directed.
Taking down ceiling fan of any make single phase and painting of ceiling fan complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust and re- fixing again in same position all as specified and as directed.
S&F MCB 6-32 Amp 240 Volt single pole 'B' series all as specified and as directed.
S&F MCB DP 32 Amp 230 Volt 50HZ AC supply all as specified and as directed.
S & F in Ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S&F MCB (DB) Vertical (TPN) 4 way double door 415 Volts complete including taking existing old unserviceable all as specified and as directed.
S&F Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps all as specified and as directed.
S&F MCB TPN 415 Volts 63 Amps 'B' series all as specified and as directed.
M& L for sub main wiring with 02 run of 4 sq mm single core copper cable PVC insulated unsheathed multi stranded 1100 volt grade drawn through PVC conduit of suitable size with accessories ext concealed in wall/ceiling with and including one run of 4 sq mm single core copper cable run through concealed PVC conduit all as specified and as directed. NOTE :- Three runs of 4 sq mm single core cable and 01 run of PVC conduit shall be measured as one unit length.
S&F Concealed GI sheet metal box(Rust Protected) (16 Gauge) module 1/2. all as specified and as directed.
As per Item No.70 here in before but 3 module all as specified and as directed.
As per Item No.70 here in before but 6 module all as specified and as directed.
As per Item No.70 here in before but 8 module all as specified and as directed.
As per Item No.70 here in before but 12 module all as specified and as directed.
S&F Modular white cover plate with frame 2 Module all as specified and as directed.
S&F Modular white cover plate with frame 3 Module all as specified and as directed.
S&F Modular white cover plate with frame 6 Module all as specified and as directed.
S&F Modular white cover plate with frame 8 Module all as specified and as directed.
S&F Modular white cover plate with frame 12 Module all as specified and as directed.
S&F Geysers 25 ltr vertical type including taking down old u/s Geyser of any capacity from the existing location and deposit to MES store yard all as specified and as directed. Note: Old geyser shall be deposited in MES store yard of AGE(I)Mandovi.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly on ground earth pit n. less than 2.25 m deep below the ground bend with top edge of the plate n. less than 1.5m below ground level connected to GI earth wire 4mm by means of bolts, nuts, checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber cover and light grade GI pipe 40mm dia for protection of strip and fund etc complete all as per electrical plate No. 3 of SSR Part-I including connections with testing point of lightening protection.
Schedule 'A' -Part III ( EXTERNAL ELECTRIFICATION)
S&F Lithium based Energy Efficient Integrated Solar light 24 Watt in single FRP encases solar PV Panel 50/55 Wp Monocrystaline Lithium Battery 11.1/12.8V, Microcontroller based charge controller cum driver automatic dimming function with PIR Motion Sensor , Dusk to Dawn Operation, working temprature (-) 10C to (+) 55C, with adjustable MS clamp suitable for pole/wall mounting. Protections : Short circuit, overload, Reverse polarity and battery protections. Firm should produce vital parameters Test report from NABL accredited lab and should be made in India with CE & ROHS all as specified and as directed. Make: Axxon AXN-24 watt or equivalent as approved by GE
S&F Medium class 65mm dia GI Pole of 6 m length with base plate 300x300x16mm thick supporting strip with base plate grouting on rag nut bolt having dia 18mm length 450mm and bolt casted on 450x450x600mm cement concrete 1:3:6 foundation including excavation and refilling etc as required all as specified and as directed.
Schedule 'A' -Part IV (Sewage Disposal )
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide in soft/disintegrated rock for foundations etc and getting out all as specified and as directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25 cm in soft/disintegrated rock all as specified and as directed.
Removing excavated material exceeding 250 m and not exceeding 500m and depositing where directed all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position such as in bed for drain pipe etc complete all as specified and as directed.
Demolition and breaking up of 150mm/160mm drain pipes (Salt glazed ware/AC/PVC) set in cement mortar all as specified and as directed.
M&L for concrete bed to drain pipe of 160mm dia including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete type C2 ,1:3:6 all as specified and as directed.
M&L for PVC (SWR) pipes 160mm single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
Demolition of brick work or stone / boulder masonry built in cement mortar all as specified and as directed.
M&L for precast cement concrete block masonry type 01 , 1:3:6 using 20 mm graded stone aggregate with solid blocks exceeding 10cm in width and set in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finish even & smooth with using extra cement all as specified and as directed.
M&L for precast RCC 1:2:4, type B-1 using 20 mm graded stone aggregate set in cement mortar 1:4 as in manhole cover slabs complete all as specified and as directed.
M & L for mild steel bars 10 mm dia and above cut to length bent to shape required including cranking, bending, hooping etc and binding with mild steel annealed wire not less than 0.9mm dia wire as in reinforcement complete all as specified and as directed.
M&L for providing PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in manholes including necessary formwork finished to required shape all as directed complete all as specified and as directed.
Ramesh Enterprises
Raja Enterprises
H.S.SIROHI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .