| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.5 L+₹1.7 L (9.83%)Rejected-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹19.3 L+₹2.5 L (14.6%)Rejected-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹19.4 L+₹2.5 L (15.0%)Rejected-AOC NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | L4 | Rejected-AOC Rejected |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Jun 2020, 6:00 pmClosed
GARRISON ENGINEER M
GARRISON ENGINEER M NAVAL AIR STATION ARAKKONAM - 631006
REPAIR/ MAINTENANCE TO COOLING APPLIANCES (WINDOW/ SPLIT AC, WATER COOLERS, REFRIGERATOR) AND VOLTAGE STABILIZERS AT ARAKKONAM
2020_MES_341785_1
8902 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE M NAS ARAKKONAM
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE M NAS ARAKKONAM
₹50,000
Yes
19 Jun 2020
16 May 2020
15 Jun 2020
16 May 2020
13 Jun 2020
30 May 2020
Amount
Checking and identifying complaints of window/ split type ACs with voltage stabilizers etc., of any make and any capacity and making it 100% functional complete all as specified and as directed by Engr-in-charge. Note: (a) Spares required to be replaced for the functioning of the AC shall be measured and paid separately under relevant item as supply only. (b) Quoted rates includes labour cost for taking down old items and fixing new one.
WINDOW TYPE AC
Taking out the existing burnt/ unserviceable compressor unit from 2.0 /1.50 TR capacity of window type Airconditioner and replacing the same with factory built hermatically sealed compressor unit including necessary accessories and mounting materials and carry out leak test by charging with CO2/ dry nitrogen gas. After arresting leakages by welding work etc., evacauting the system and charging of R-22 Refrigerant gas after ensuring leak proof condition and test to the satisfaction complete all as specified and as directed by Engr-in-charge.
Servicing of Window type AC 1.5/ 2.0 TR on capacity of any make/ model by taking out the ACs, Cleaning of evaporating coil, condensing coil with water and brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ACs complete all as specified and as directed by Engr-in-charge. Note: Spares required to be replaced shall be measured and paid separately under respective items.
Supply only blower motor, single phase, 230 volts 50 Hz with capacitor and mounting materials, suitable for 2.0 ton and 1.5 ton capacity of window type ACs complete all as specified and as directed by Engr-in-charge.
Supply only thermostatic switch for 2.0 ton and 1.5 ton window type AC complete all as specified and as directed by Engr-in-charge.
Supply only Airfilter pad of suitable size and thickness for 2.0 ton /1.5 ton window type AC complete all as specified and as directed by Engr-in-charge.
Supply only running capacitor for 2.0 ton /1.5 ton window type AC 35+6 MFD, 230 V AC complete all as specified and as directed by Engr-in-charge.
Supply only metallic/ PVC fan blade of existing size and type for 2.0/ 1.5 ton window type AC complete all as specified and as directed by Engr-in-charge.
Supply only 4 MFD 230 V AC capacitor complete all as specified and as directed by Engr-in-charge.
Supply only 6 MFD 230 V AC capacitor complete all as specified and as directed by Engr-in-charge.
Supply only condenser coil suitable for 2.0 ton/ 1.5 ton window type AC complete all as specified and as directed by Engr-in-charge. Note for item Nos 5 to 13: Labour charges deemed to be included in the rate quoted for the item No.4 here-in-before.
Material and labour for charging of refrigerant R-22 including cost of welding leak detection and refitting the same in entire system, including replacing defective liquid strainer and capillary tube. Testing and commissioning complete to the satisfaction of Engr-in-charge for 1.0 TR/1.5 TR window AC complete all as specified and as directed by Engr-in-charge.
SPLIT TYPE ACs
Taking out existing burnt/ unserviceable compressor unit from the following Air conditioner rotary/ reciprocating type and replacing the same with new factory built hermatically sealed compressor unit including necessary accessories and mounting materials, carryout leak test by charging with CO2/ dry nitrogen gas. After arresting the leakes by welding etc., evacuating the system and charging of R-22/ R410/ R32 refrigerant gas as required after ensuring leak proof condition and testing for the following Air conditioners complete all as specified and as directed by Engr-in-charge.
1.5 TR capacity of split type Airconditioner.
2.0 TR capacity of split type Airconditioner.
Servicing of split type AC 1.5/ 2.0 TR capacity of any make/ model by taking out the AC, cleaning of evaporating coil, condensing coil with water and brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete including replacing damaged/ unserviceable accessories/ spare parts complete all as specified and as directed by Engr-in-charge. Note: (a) Spares required to be replaced for the functioning of the AC shall be measured and paid separately under relevant item as supply only. (b) Quoted rates includes labour cost for taking down old items and fixing new one.
Supply only new blower motor with capacitor and mounting material single phase, 230V, 50Hz for 1.5/ 2.0 TR capacity of Split type AC complete all as specified and as directed by Engr-in-charge.
Supply only Airfilter pad of suitable size and specification as per existing filter for 1.5 TR /2.0 TR capacity of Split type AC complete all as specified and as directed by Engr-in-charge.
Supply only running capacitor for 1.5 / 2.0 TR split type AC, 36 + 6 MFD / 45 + 6 MFD, 230 V AC complete all as specified and as directed by Engr-in-charge.
Supply only running capacitor for 1.5 TR/ 2.0 TR split type AC, 50+4 MFD 230 V AC complete all as specified and as directed by Engr-in-charge.
Supply only metallic/ PVC fan blade,of existing size and rotation for 1.5 and 2.0 TR split type AC complete all as specified and as directed by Engr-in-charge.
Supply only new liquid line service valve of same size including welding of joints for 1.5 and 2.0 TR split type AC complete all as specified and as directed by Engr-in-charge.
Supply only suction service valve for1.5 and 2.0 TR split type AC complete all as specified and as directed by Engr-in-charge.
Supply only PCB circuit board complete with remote control as per old one for 1.5 and 2.0 TR split type AC complete all as specified and as directed by Engr-in-charge.
Supply only 3 core PVC sheathed copper cable of size 2.5 Sqmm length 3m suitable for 1.5 TR Split type AC complete all as specified and as directed by Engr-in-charge.
Supply only 5 core PVC sheathed copper cable of size 7/0.0076 (4 Sqmm) length 3m suitable for 2.0 ton Split type AC complete all as specified and as directed by Engr-in-charge.
Supply only standard length drain pipe suitable for1.5 / 2.0 TR split AC complete all as specified and as directed by Engr-in-charge.
Supply only blower of existing size and make for Split Air Conditioner Indoor unit complete all as specified and as directed by Engr-in-charge.
Supply only condensed water tray of existing size and make for split AC indoor unit complete all as specified and as directed by Engr-in-charge.
Supply only running capacitor 2 Mfd for fan motor complete all as specified and as directed by Engr-in-charge.
Supply only condenser coil for 1.5 / 2TR split type AC complete all as specified and as directed by Engr-in-charge.
Supply only condenser fan motor single phase for 1.5 / 2 TR split AC complete all as specified and as directed by Engr-in-charge.
Supply only indoor evaporator coil suitable for following split AC blower complete all as specified and as directed by Engr-in-charge.
Indoor 1.5 TR
Indoor 2 TR
Supply only Magnetic contactor suitable for split type Air Conditioner suitable for 1.5/ 2 TR suitable for spit type ACs as per existing make and model complete all as specified and as directed by Engr-in-charge.
Supply only air direction changer louver motor (swing motor) suitable for spit type ACs as per existing make and model complete all as specified and as directed by Engr-in-charge. Note for Item Nos.16 to 34: Labour charges deemed to be included in the rate quoted for the item No.17 here-in-before.
Material and labour for Charging of refrigerant R-22 /R410 /R32 including leak detection, welding and refitting the same in entire system, including replacing defective liquid strainer and capillary tube for 1.5/ 2.0 TR split AC including testing complete all as specified and as directed by Engr-in-charge.
Material and labour for cleaning and preparation of old painted surfaces of Split type AC out door unit and spray painting to AC complete with two coats of synthetic enamel paint and marking SM/ MES Nos, re-fixing the out door unit of split type AC complete all as specified and as directed by Engr-in-charge.
Taking out existing old leaked copper pipe Supply and fix new copper pipe 1/2" outer dia including insulating sleeve complete all as specified and as directed by Engr-in-charge.
Taking out existing old leaked copper pipe Supply and fix new copper pipe 1/4" outer dia including insulating sleeve complete all as specified and as directed by Engr-in-charge.
Taking out existing old leaked copper pipe Supply and fix new copper pipe 3/8" outer dia including insulating sleeve complete all as specified and as directed by Engr-in-charge.
Taking out existing old leaked copper pipe Supply and fix new copper pipe 5/8" outer dia including insulating sleeve complete all as specified and as directed by Engr-in-charge.
Removing existing damaged fixing kit of outdoor unit of split AC with stand, Supply and fix new fixing kit with stand for split type AC complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable overload relay, Supply and fix new overload relay of range 5 to 8 Amps complete all as specified and as directed by Engr-in-charge.
Supply and fix PVC flexible pipe for condensed water as per existing size and length including taking down the existing old damaged unserviceable one complete all as specified and as directed by Engr-in-charge.
Supply and fix split type AC indoor unit with remote suitable for following capacity of any make/ model as exists at site including taking down the existing damaged unserviceable one and depositing to MES store yard complete all as specified and as directed by Engr-in-charge.
Supply and fix split type AC out door unit with all accessories suitable for following capacity of any make/ model as exists at site including taking down the existing one and depositing to MES store yard complete all as specified and as directed by Engr-in-charge.
Taking out defective/ damaged Industrial Plug and Socket and supply and fix Industrial new Plug and Socket for AC distribution box with socket and MCB 20A 'C' curve, 240 V, suitable of split ACs 1.5/ 2.0 TR complete all as specified and as directed by Engr-in-charge. Make: ABB/ Schneider/ Siemens/ Legrend/ L&T
All as per item No.48 here-in-before but AC distribution box with socket and MCB 32A 'C' curve, 240 V.
Dismantling and taking down carefully the existing indoor and out door units of tonnage 1.5/2 TR from the existing positions for complete servicing, cleaning, greasing and maintenance and refixing the outdoor and indoor units after servicing/ maintenance with necessary copper tubing with insulation including gas charging and connecting with stabilzer etc., and testing for its proper functioning complete all as specified and as directed by Engr-in-charge. Note: (a) Spares required shall be measured and paid under relevant items of schedule. (b) Labour charges for replacing spares/ components is deemed to be included in the rate quoted for this item.
Supply and fix synthetic rubber tube insulation of thickness 9mm and internal diameter-6mm (1/4") for refrigerant copper piping of split AC units including taking down the existing complete all as specified and as directed by Engr-in-charge.
All as per item No.51 here-in-before but internal dia 9mm (3/8").
All as per item No.51 here-in-before but internal dia13mm (1/2").
All as per item No.51 here-in-before but internal dia 16mm (5/8").
Supply and fix MCBs SP 6-32 Amp, 240V 'C' curve 10KA including taking down the existing one complete all as specified and as directed by Engr-in-charge. Make: ABB/ Schneider/ Siemens/ Legrend/ L&T
VOLTAGE STABILIZER
Taking out defective/ burnt auto transformer, Supply and fix new auto transformer for voltage stabilizer 4 KVA/ 5 KVA capacity complete all as specified and as directed by Engr-in-charge.
All as per item No.57 here-in-before but for capacity upto 3 KVA.
Taking out defective PCB (Printed Circuit Board) complete with components, Supply and fix new PCB complete with components of 4 KVA/ 5 KVA Voltage stabilizer complete all as specified and as directed by Engr-in-charge.
All as per item No.59 here-in-before but for capacity upto 3 KVA.
Taking out defective relay, Supply and fix new relay for voltage stabilizer 3.0 KVA/ 4.0 KVA/ 5.0 KVA capacity complete all as specified and as directed by Engr-in-charge.
All as per item No.61 here-in-before but for capacity 1.0/ 0.5 KVA.
Taking out unserviceable volt meter 0 to 300 Volts, Round/ Square type, Supply and fix volt meter 0 to 300 Volts in Voltage stabilizer/ as per existing model complete all as specified and as directed by Engr-in-charge.
Taking out burnt connector, Supply and fix electric connector 20 Amps in Voltage stabilizer complete all as specified and as directed by Engr-in-charge.
Taking out burnt/ unserviceable multi plug 3 pin socket, Supply and fix new 3 pin multi plug socket 5/ 15 Amps, 230 Volts for Voltage stabilizer complete all as specified and as directed by Engr-in-charge. Make: Anchor/ Cona/ Leader
Supply and fix 3 pin plug top 15 Amps including taking down the existing unserviceable burnt one complete all as specified and as directed by Engr-in-charge.
Supply and fix Metal clad plug socket three pin, 20A, 240V including taking down the existing unserviceable one complete all as specified and as directed by Engr-in-charge.
Supply and fix Metalclad plug top three pin, 20A, 240V including taking down the existing unserviceable one complete all as specified and as directed by Engr-in-charge.
Material and labour for marking SM / MES Nos on the split type AC Window Type AC, Water cooler, Refrigerator, etc., with synthetic enamel paint of approved make and tint with letter size /type complete all as specified and as directed by Engr-in-charge.
WATER COOLER/REFRIGERATOR/DEEPFREEZER
Servicing of water cooler 40/ 80 ltrs capacity, cleaning of evaporating coil, condensing coil with water and brush to remove dust and checking of electric circuit for smooth functioning of water coolers complete all as specified and as directed by Engr-in-charge. Note: (a) Spares required shall be measured and paid under relevant items of schedule as supply only. (b) Labour charges deemed to be included in the rate quoted for this item.
Supply only of suitable compressor for water cooler 40 /80 ltrs with connecting and necessary arrangements complete all as specified and as directed by Engr-in-charge.
Supply only of the following items for water cooler 40 /80 ltrs with connecting and necessary arrangements complete all as specified and as directed by Engr-in-charge.
Relay and OLP
Thermostat
SS Drain tray
Drain hose
Float valve assembly size 15mm
Supply only condensor fan motor suitable for 40/ 80 ltrs capacity complete all as specified and as directed by Engr-in-charge.
Supply only condensor fan motor blade suitable for 40/80 ltrs capacity complete all as specified and as directed by Engr-in-charge.
Supply only capacitor 10Mfd, 230 V, 50 Hz complete all as specified and as directed by Engr-in-charge.
Supply and fix push cock steel made suitable for water cooler complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of suitable compressor for refrigerator 465 ltrs capacity including leak test and gas charging etc., with necessary connecting arrangements complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of the following items for for refrigerator 465 ltrs capacity complete all as specified and as directed by Engr-in-charge.
Relay and OLP
PCB suitable for Refrigerator
Evaparator fan motor suitable for Refrigerator
Material and labour for charging of refrigerant R-134A including leak detection, welding and testing the same in entire system, including replacing of defective liquid strainer and capillary tube for refrigerator complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of suitable compressor for deep freezer 400 ltrs capacity with gas charging, connecting and necessary arrangements complete all as specified and as directed by Engr-in-charge.
Supply and fix condensor fan motor suitable for deep freezer 400 ltrs capacity complete all as specified and as directed by Engr-in-charge.
Supply and fix thermostat switch complete all as specified and as directed by Engr-in-charge.
Supply and fix Relay and OLP complete all as specified and as directed by Engr-in-charge.
Material and labour charging of refrigerant R-134A including leak detection, welding and testing the entire system, including replacing of defective liquid strainer and capillary tube for deep freezer complete all as specified and as directed by Engr-in-charge.
KRISHNA ENTERPRISES
rc enterprises
C SRINIVASAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .