Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.2 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | 2₹26.4 L+₹2.2 L (9.08%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹27.2 L+₹3.0 L (12.2%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹30.2 L+₹6.0 L (24.6%)Rejected-Finance SHOP NO 33 GOPI NATH BAZAR DELHI CANTT 10 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹36.2 L+₹11.9 L (49.2%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 5 | Rejected-Finance Rejected being not L1 |
| Sl No | Description | Qty | Unit | M/s JAIMAA ASSOCIATES L4 | mayur enterprises L3 | DS CONSTRUCTION L7 | Vijay Electricals L1 | SANJEEV ENTERPRISES L8 | MV Engineers And Contractors L6 | Commercial Traders L5 | M P TYAGI ENGINEERS AND CONTRACTORS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material & labour for excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe (where provided for protection of cable or fixing with poles and stays) and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed by the Engr-in-Charge. | 822.96 | Cum | 140 ₹1,15,214.4 | 50 ₹41,148 | 100 ₹82,296 | 40 ₹32,918.4 Lowest | 50 ₹41,148 | 99 ₹81,473.04 | 85 ₹69,951.6 | 49 ₹40,325.04 |
| 2.00 | Material & labour for returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the Engr-in-Charge. | 509.98 | Cum | 20 ₹10,199.6 | 20 ₹10,199.6 | 20 ₹10,199.6 | 10 ₹5,099.8 | 25 ₹12,749.5 | 16 ₹8,159.68 | 15 ₹7,649.7 | 9 ₹4,589.82 Lowest |
| 3.00 | Material & labour for removal excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. | 312.98 | Cum | 20 ₹6,259.6 | 20 ₹6,259.6 | 20 ₹6,259.6 | 10 ₹3,129.8 | 10 ₹3,129.8 | 16 ₹5,007.68 | 20 ₹6,259.6 | 9 ₹2,816.82 Lowest |
| 4.00 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc,complete all as specified and directed by the Engr-in-Charge. Note : Measurement shall be taken after punning down. | 219.67 | Cum | 250 ₹54,917.5 | 200 ₹43,934 | 300 ₹65,901 | 200 ₹43,934 | 300 ₹65,901 | 260 ₹57,114.2 | 300 ₹65,901 | 99 ₹21,747.33 Lowest |
| 5.00 | S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by the Engr-in-Charge. | 10.93 | Per 1000 Nos | 2,500 ₹27,325 | 3,000 ₹32,790 | 3,000 ₹32,790 | 2,000 ₹21,860 | 2,500 ₹27,325 | 3,200 ₹34,976 | 3,000 ₹32,790 | 999 ₹10,919.07 Lowest |
| 6.00 | All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before. complete all as specified and directed by the Engr-in-Charge. | 7.29 | Per 1000 Nos | 100 ₹729 | 500 ₹3,645 | 0.1 ₹0.73 Lowest | 1 ₹7.29 | 1,500 ₹10,935 | 100 ₹729 | 0.5 ₹3.65 | 499 ₹3,637.71 |
| 7.00 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and directed by the Engr-in-Charge. | 2,240 | Each | 19 ₹42,560 | 15 ₹33,600 | 35 ₹78,400 | 25 ₹56,000 | 30 ₹67,200 | 15 ₹33,600 | 21 ₹47,040 | 0.99 ₹2,217.6 Lowest |
| 8.00 | All as per srl item No 7 here-in-before but using old un-reinforced precast concrete cable cove obtained under srl item No 1 complete all as specified and directed by the Engr-in-Charge. | 1,493 | Each | 1 ₹1,493 | 0.5 ₹746.5 | 0.1 ₹149.3 Lowest | 1 ₹1,493 | 5 ₹7,465 | 1 ₹1,493 | 0.5 ₹746.5 | 0.99 ₹1,478.07 |
| 9.00Supplying, laying, jointing testing and connecting in replacement of overhead lines/underground cables, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by the Engr-in-Charge of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. | |||||||||||
| 9.01 | 16 Sqmm 4 core | 600 | RM | 115 ₹69,000 | 120 ₹72,000 | 140 ₹84,000 | 120 ₹72,000 | 140 ₹84,000 | 121 ₹72,600 | 145 ₹87,000 | 99 ₹59,400 Lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
19 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR AND MAINTENANCE OF ELECTRICAL BREAKDOWN INC FAULT DETECTION, LOCALIZATION AND RECTIFICATION IN UNDERGROUND NETWORK AT BI LINE, RRRC, KHYBER LINES, KHYBER LINE FAMILY QTR, ARJAN VIHAR, NEW PRATAP CHOWK, PRATAP CHOWK, MANDIR MARG, AHPU, TAURAS
2025_MES_717380_1
GE ELECT/D-45/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹92,000
Yes
16 Sept 2025
28 Jun 2025
21 Jul 2025
28 Jun 2025
19 Jul 2025
12 Jul 2025
Amount
Material & labour for excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe (where provided for protection of cable or fixing with poles and stays) and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed by the Engr-in-Charge.
Material & labour for returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the Engr-in-Charge.
Material & labour for removal excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc,complete all as specified and directed by the Engr-in-Charge. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by the Engr-in-Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before. complete all as specified and directed by the Engr-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and directed by the Engr-in-Charge.
All as per srl item No 7 here-in-before but using old un-reinforced precast concrete cable cove obtained under srl item No 1 complete all as specified and directed by the Engr-in-Charge.
Supplying, laying, jointing testing and connecting in replacement of overhead lines/underground cables, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by the Engr-in-Charge of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by the Engr-in-Charge of following sizes :- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
95 sqmm 3 core.
120 sqmm 3 core.
150 sqmm 3 core.
185 sqmm 3 core
240 sqmm 3 core
300 sqmm 3 core
400 Sqmm 3 core
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by the Engr-in-Charge. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 11 above but 1100 Volt LT cables complete all as specified and directed by the Engr-in-Charge.
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed by the Engr-in-Charge. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 13 above but 11000 Volt HT cables complete all as specified and directed by the Engr-in-Charge.
Material and labour for disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as specified and directed by the Engr-in-Charge.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed by the Engr-in-Charge for the following sizes :-
16-25 Sqmm x 3.5 core/ 4 core
35-50 Sqmm x 3.5 core
70-95 Sqmm x 3.5 core
120-150 Sqmm x 3.5 core
185 -300 Sqmm x 3.5 core
Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engr-in-Charge of following size :-
95 Sqmm,3 core to 120 Sqmm 3 core
150 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 400 Sqmm 3 core
Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engr-in-Charge of following size :-
95 Sqmm 3 core to 120 sqmm 3 Core
150 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 400 Sqmm, 3 core.
Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engr-in-Charge of following size :-
95 Sqmm 3 core to 120 sqmm 3 Core
150 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 400 Sqmm 3 core
Material & labour for boring of hole under road/pavement/hard standing or any other situation by manual means and including GI pipe 100 mm bore (medium grade) and making good both ends complete all as specified and directed by the Engr-in-Charge.
Supply and laying of GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc complete all as specified and directed by the Engr-in-Charge of following sizes:-
100 mm dia
80 mm dia
50 mm dia
40 mm dia
Supply and laying as replacement in sub station fixing 3.3 KV to 11 KV insulating mat of size 5mtr x 1 mtr x 2.5 mm thick specification as per IS-15652 2006 complete all as specified and directed by the Engr-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I complete all as specified and directed by the Engr-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode.
S&F in replacement of UNSV /Burnt MCCBs of capacity 630 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by the Engr-in-Charge.
All as per ser item No 24 above but rating of MCCB 400 Amp, 36 KA complete all as specified and directed by the Engr-in-Charge.
All as per ser item No 24 above but rating of MCCB 100 Amp, 25 KA complete all as specified and directed by the Engr-in-Charge.
All as per ser item No 24 above but rating of MCCB 63 Amp, 16 KA complete all as specified and directed by the Engr-in-Charge.
Supplying & fixing in renewal on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable changeover from panels etc complete all as specified and directed by the Engr-in-Charge.
Supplying & fixing of cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar 150mm c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enamel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33 /11KV as directed by Engr-in-charge complete all as specified and directed by the Engr-in-Charge. (NOTE : Sample kept in Engr-in-Charge's office) Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm including necessary excavation & earthwork for cable route indicator deemed to be included in the item.
Material and labour for spreading of stone aggregate of nominal size not more than 25mm under 4/6 pole HT structure /surrounding area of outdoor RMU manually without damaging any equipments, cable or parts , spreading & leveling of finished gravel uniformly in layers n. ecc. 15 cm thick watered and rammed to true surface complete all as specified and directed by the Engr-in-Charge.
Supplying & fixing of LED street light Fitting 60 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV complete all as specified and directed by the Engr-in-Charge. NOTE : Make WIPRO Cat Part No. LR02-671-XXX-57-G3 or equivalent in Philips / Bajaj as approved by GE.
Supplying & fixing of LED street light Fitting 45 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV complete all as specified and directed by the Engr-in-Charge. NOTE : Make WIPRO Cat Part No. LR02-501-XXX-57-G3 or equivalent in Philips / Bajaj as approved by GE.
Supply, drawing, connecting & testing of 3 core, 1.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 in steel tubular pole from KIOSK box to light fittings including PVC conduit of size 20mm bore with clamping(Wherever required) and providing suitable copper lugs complete all as specified and directed by the Engr-in-Charge.
Supply and fixing of LED Flood light fittings in replacement of capacity 120 Watt suitable for mounting on street light poles through suitable clamps, IP-65 protection, single piece pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 5 KV, with bolts, nuts & washers complete all as specified and directed by the Engr-in-Charge. NOTE : Make WIPRO Cat Part No. LF40-132-060-57-XX or equivalent in Philips / Bajaj as approved by GE.
Supply and fixing of LED Flood light fittings in replacement of capacity 200 Watt suitable for mounting on street light poles through suitable clamps, IP-65 protection, single piece pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 5 KV, with bolts, nuts & washers complete all as specified and directed by the Engr-in-Charge. NOTE : Make WIPRO Cat Part No. LF40-272-060-57-HE or equivalent in Philips / Bajaj as approved by GE.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc complete all as per manufacturer's instructions and as specified and as directed by Engr-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swan neck poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc complete all as per manufacturer's instructions and as specified and as directed by Engr-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
S&F KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps and 6 Amps MCB with base including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body with MS clamp of suitable sizehaving suitable size nut,bolts & washer complete all as specified and directed by the Engr-in-Charge.
Supply & Fixing in replacement bracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete all as specified and directed by the Engr-in-Charge.
Material and labour for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by the Engr-in-Charge.
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 500 Amps aluminium bus bar and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply and Installation of HT CT operated Trivector Meter with the following specifications:- (a) Meter Type: HT 3 Phase 4 Wire Electronic Tri vector Meter (b) Standard: IS 13779:1999 / CBIP 88 (c) Accuracy: Class 0.5 (d) Voltage and Current rating:- (i) Reference Voltage - 3x240 V (ii) Basic Current (Ib) - 5 A (iii) Maximum continuous current (Imax) - 10 A (e) Rated Frequency (variation) - 50Hz (±5%) (f) Power consumption:- (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (g) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (h) Display in the event of Power Failure: Internal battery back-up for LCD display (j)Communication port: (iii) Energy recording - Unidirectional
Supply and fixing of mild steel chequered plates Fe410-10-W(Gde-E-250) qualityon cable pit sizes as required on site 6mm to 10 mm thick including taking out old unsv RCC duct cover complete all as specified and directed by the Engr-in-Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3363625)
mayur enterprises (BID ID -3363594)
M/s JAIMAA ASSOCIATES (BID ID -3363142)
Commercial Traders (BID ID -3364650)
MV Engineers And Contractors (BID ID -3364417)
DS CONSTRUCTION (BID ID -3363736)
SANJEEV ENTERPRISES (BID ID -3364347)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .