Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 CrAccepted-AOC | ₹7.4 Cr Quoted ₹7.5 Cr | L1 | Accepted-AOC Being Lowest Bidder and reasonable bid |
| 2 | L2₹7.5 Cr+₹1.8 L (0.24%)Rejected-Finance | ₹7.5 Cr+₹1.8 L (0.24%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹8.8 Cr+₹1.4 Cr (18.1%)Rejected-Finance | ₹8.8 Cr+₹1.4 Cr (18.1%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical EMD not submitted in prescribed bank instrument |
| Sl No | Description | Qty | Unit | Deepesh Electricals L1 | M/s Kohli Builders L2 | Raja enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00Note:-Please refer schedule 'A' notes before quoting the tender. | ||||||
| 2.00GENERAL SUMMARY | ||||||
| 2.01 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART - I BUILDING WORKS as listed in Schedule ‘A’ Part- I (BUILDING WORK) Ref prepriced schedule attached seperately) | 1 | LUMP SUM | 50,27,000 ₹50,27,000 Lowest | 55,00,000 ₹55,00,000 | 70,00,000 ₹70,00,000 |
| 2.02 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – II (INTERNAL WATER SUPPLY) as listed in Schedule ‘A’ Part-II (Ref prepriced schedule attached seperately) | 1 | LUMP SUM | 14,619.6 ₹14,619.6 Lowest | 20,000 ₹20,000 | 15,000 ₹15,000 |
| 2.03 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – III INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately) | 1 | LUMP SUM | 1,55,300.64 ₹1,55,300.64 Lowest | 1,80,000 ₹1,80,000 | 1,75,000 ₹1,75,000 |
| 2.04 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – IV EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately) | 1 | LUMP SUM | 2,53,170.1 ₹2,53,170.1 Lowest | 3,50,000 ₹3,50,000 | 4,30,000 ₹4,30,000 |
| 2.05 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – V (EXTERNAL ELECTRIC SUPPLY WORKS) as listed in Schedule ‘A’ Part-V (Ref prepriced schedule attached seperately) | 1 | LUMP SUM | 5,42,936.85 ₹5,42,936.85 | 9,00,000 ₹9,00,000 | 5,20,000 ₹5,20,000 Lowest |
| 2.06 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-VI (ROAD, PATH AND CULVERT WORKS) as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately) | 1 | LUMP SUM | 2,40,000 ₹2,40,000 Lowest | 3,00,000 ₹3,00,000 | 2,75,000 ₹2,75,000 |
| 2.07 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – VII (SEWAGE DISPOSAL WORKS) as listed in Schedule ‘A’ Part-VII (Ref prepriced schedule attached seperately) | 1 | LUMP SUM | 80,500 ₹80,500 Lowest | 1,00,000 ₹1,00,000 | 90,000 ₹90,000 |
| 2.08 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – VIII (DEMOLITION / DISMANTLING WORKS) (working in normal condition) as listed in Schedule ‘A’ Part- VIII (Ref prepriced schedule attached seperately) | 1 | LUMP SUM | 7,10,000 ₹7,10,000 Lowest | 10,00,000 ₹10,00,000 | 14,20,000 ₹14,20,000 |
Tender Value
₹8.3 Cr
EMD Value
₹7.4 L
Closing Date
23 Aug 2025, 6:00 pmClosed
CHIEF ENGR, BHOPAL ZONE
HQ CHIEF ENGR BHOPAL ZONE, MES SI LINE BHOPAL 462001
PROVN OF HIGH SECURITY WALL INCL WATCH TOWERS ALONGWITH THE ENTIRE PERIMETER INCL PROVN OF POLES WITH LED SECURITY LIGHTS OF ARMY AVN SQN AT JHANSI UNDER GE JHANSI
2025_MES_715165_1
CEBZ/JHA/TOKEN/19 OF 2024-25
Open Tender
Civil Works
Lump-sum
240 days
Jhansi
As per NIT documents
5 documents required · 5 mandatory
₹3,000
GE Jhansi
₹7.4 L
Bhopal
18 Dec 2025
18 Jun 2025
25 Aug 2025
18 Jun 2025
23 Aug 2025
9 Aug 2025
3 Jul 2025
Amount
Note:-Please refer schedule 'A' notes before quoting the tender.
GENERAL SUMMARY
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART - I BUILDING WORKS as listed in Schedule ‘A’ Part- I (BUILDING WORK) Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – II (INTERNAL WATER SUPPLY) as listed in Schedule ‘A’ Part-II (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – III INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – IV EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – V (EXTERNAL ELECTRIC SUPPLY WORKS) as listed in Schedule ‘A’ Part-V (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-VI (ROAD, PATH AND CULVERT WORKS) as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – VII (SEWAGE DISPOSAL WORKS) as listed in Schedule ‘A’ Part-VII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – VIII (DEMOLITION / DISMANTLING WORKS) (working in normal condition) as listed in Schedule ‘A’ Part- VIII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – IX (DEMOLITION / DISMANTLING WORKS) (working in water and liquid mud condition) as listed in Schedule ‘A’ Part- IX (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART –X (COMPOUND WALL FENCING AND RETAINING WALL) ( in water or liquid mud condition) as listed in Schedule ‘A’ Part- X (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – XI (COMPOUND WALL FENCING AND RETAINING WALL) (in normal condition) as listed in Schedule ‘A’ Part-XI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – XII (EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS) as listed in Schedule ‘A’ Part-XII (Ref prepriced schedule attached seperately)
SCH 'A' Pt - XIII (MISCELLANEOUS ITEMS)
INTERNAL WATER SUPPLY WORKS NOTE:- For items of Internal Water Supply Works notes given at the beginning of Sch ‘A’ Part-II ( Internal Water Supply Works) shall also be applicable.
S&F for 15mm bore bib taps, long body chromium plated fancy type with crutch or butter fly handle, screwed down and screwed for iron pipe or for unions complete all as specified and directed
S& F for CP urinal spreader for fixing with 15mm dia pipe complete all as specified and directed
INTERNAL ELECTRIFICATION WORKS NOTE:- For items of Internal Electric Supply Works notes given at the beginning of Sch ‘A’ Part-III ( Internal Electrification Works) shall also be applicable.
M&L point wiring for light point wiring complete with 1.5 Sq.mmm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade draw through in and including 20 mm dia PVC conduit and conduit accessories, concealed in walls and terminated to and including provision of modular metal flush boxes (metal switch board of any type and size) with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for the following points (Ser Item No 5.02 to 5.04) . NOTE;- The quoted rate is deemed to inclusive of cost of metal flush boxes, modular white cover plate.
One light point/ fan point/ exhaust fan point controlled by one way 6A modular switch with ISI Marked
One socket outlet 3pin independent controlled by one way 6A modular switch with ISI Marked
All as per Sl item No. 5.01 above, but with cable 4.0 sqmm for phase and neutral & 4.0 sqmm for earth continuity complete for 6/16 Amps socket point on independent board with ISI Marked complete all as specified and directed
S&F 7W white LED retrofit lamp 230V AC, 50 Hz single phase suitable for B-22 holder base with polycarbonate diffuser and aluminium heat sink with ISI Marked complete all as specified and directed. Notes:- 1. Warranty for replacement of each LED Light fitting shall not be less than 05 years from the date of purchase. 2. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warranty benefits.
S&F LED tube light fitting batten type, 20 W, 230v , efficacy not less than 120 Lumens per watt, colour temprature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20,THDv within 5% and THDi (8-10%) and integrated electronic driver complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size from ceiling rose all with ISI Marked as specified and directed. Notes :- 1.The rate of flexible copper conductor cable of suitable size for connection is included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LED Light fitting shall not be less than 05 years from the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warranty benefits.
S&F LED tube light fitting batten type, 10 W, 230v , efficacy not less than 120 Lumens per watt, colour temprature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20,THDv within 5% and THDi (8-10%) and integrated electronic driver complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size from ceiling rose all with ISI Marked as specified and directed. Notes :- 1.The rate of flexible copper conductor cable of suitable size for connection is included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LED Light fitting shall not be less than 05 years from the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warranty benefits.
S & F LED Security light fitting 35 Watt, system luman efficacy of LED not less than 120 luman/W, PF> 0.95, THD < 10%, colour temprature 6000 to 6500K, CRI > 70, system lumen not less then 3000 Lm, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with toughed glass having bottom separate driver compartment with IP 66 Protection and Impact resistant of IK 07 etc and all accessories previewed complete including mounting bracket of 40 mm inner dia light grade GI pipe of required length and shape incl bending, forging or welding etc and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sqmm three core from ceiling rose to fitting complete all as specified and directed by Engr-in-Charge.
EXTERNAL ELECTRIC SUPPLY WORKS NOTE:- For items of External Electric Supply works notes given at the beginning of Sch ‘A’ Part-V ( External Electric Supply Works) shall also be applicable.
Supply and erection of Steel tubular swaged poles double swanneck type complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 mtr long) including painting of poles with two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and black bituminous paint on embedded portion and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips of 5 cm wide in Green (02 Nos) & White (01 No) colour shall be provided at a height of 1.25 mtr from coping of pole and writing the pole number in black colour on yellow back ground at a suitable place on the pole complete all as specified and directed. Note: (a) Cost of numbering of poles shall be deemed to be included. (b) Excavation, earth work and PCC foundation will be measured and paid for separately. (c) The pole shall be marked with designation manufacturer identification and year of manufacture.
Supply and fix 35 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including taking down of existing unserviceable street light fitting of any description complete all as specified and directed. Note :- (i) The rate of three core twisted flexible copper conductor cable of suitable size for connection is included in this item and noting shall be paid extra on this account. (ii) Watranty for replacement of each LED lite fitting shall not be less than 2 years from the date of purchase. (iii) Date of purchase shall be marked on each fixture with permanent marker for redeeming warranty benefits.
Supply and fix of street light control panel board 12 KW capacity, 3 Ph nature switch(using infraredsensor technology) based automatic street light timer switch for automatic switching on /off street light based on lux level of nature light(required illumination level for switching ON is ≤ 60 Lux and for switching OFF ≥ 10 LUX).The sensor should also have part night operation facilityof min 4 hrs,consisting of sensor over load protection fuse gear, 3 Nos contactors 3 Nos incomming MCBs & 3 Nos outgoing MCBs of 32-40 Ampseach and circuit wiring(Copper) of minimum 10 Sqmm,terminal blocks of cable entry & control unit inclosed in pole /wall mountable polycorbonate enclosur made out of rust proof , electrical shock proof, termite proofwith HINGED LID confirming toIP 66 protection class 2 complete all as specified and as directed.
Supply & installation of of hi-intensity, multi functional, fully-automatic,undirectional,300 watt LED search light, Efficacy >140 im/w, CCT 5500K, LM6 housing, front dia>440 mm; operating voltage, 90V-300V, 50hz, PF >0.95, THD <10%, CCT 5500K, CRI >70, Optics used -PMMA/PC lens, narrow beam 5 degree, average lux level at 10meter > 10000 with circle of apprx 1meter, toughened glass with silicaon gasket, over volt/ under volt & short circuit protected , confirming to LM79 , LM80, IK07, IP66, lux Cert, Type tested- IS:10322, IS:15885, and BIS certified. This search-light Should be installed on rotating disk of revolving mechanism with suitable motor-gear unit & designed to rotate 360O continuously over the night in horizental plane and tiltable upto 45 degree through motor. A seperate wall mounted wired control panel (consist of MCB's, V-meter,Fuse, LED indicator), inbuilt feature of speed controller (1 to 10 rpm). Auto / Manual, Reverse / forward, up / down through push buttons for remote operation. The revolving mechanism is fully coverd with weather & rust proof die cast fiber box with maintanance window & side doors, provision of foundation holes at bottom for proper installation
Supply and installation of solar Luminary 4 x 30 Wattage Input Voltage 12. 8V DC Driver efficiency >85% Dusk to Down & Charge Controller The PV Module itself will be used to sense the ambient light to switch ON /OFF the Lamp. Inbuilt MPPT charge controller , Operation Mode Pre fixed dimming with first 2 hours. 100% brightness, Next 2 hrs with 75% Brightness and Next till morning 50% Brightness Optical Luminious Flux 3600 Lumens (AT Full Brightness ) Luminious Efficacy 120 Lumens Per watt Color Temprature Cool White (6500K) CRI ≥70 Optics Used as required Mechanical Material used for LED Engine Metal Core PCB Material for Housing Aluminum Die Casting Color of Housing Black Safety Protections No load Low Voltage cut-off Reverse polanty (load and bettery) Enviromental IP65 LED Type of LED power Led LED beam angle Wide beam angle (120°) LED Life 50,000 Hours INDICATORs Green LED Will only glow when the charging is taking place. It shall stop glowing when the battery is full charge , RED LED should indicate the battery load cut off condition. Pole With Arnm , Panelo structure and Battery Box 7 mtr Pole HDGI Battery Recommended Battery Rating 12.8V/54AH /Box type-BIS Standerd Battery Type LifePO4 With BMS PV Module PV Module Rating 125Wp Mono/Poly Crystalline Under STC Working Temprature 0°C ~ 50°C APPROVED. Note: The quoted rate shall deemed to be inclusive of RCC foundation concrete, necessary excavation, erth work & RFR etc complete as per manufacturer's recommendation. Contractor shall submit the pole drawing and foundation drawing as per manufacturer's recommendation for approval before procurement. Note :- (i) The rate of three core twisted flexible copper conductor cable of suitable size for connection is included in this item and noting shall be paid extra on this account. (ii) Watranty for replacement of each LED lite fitting shall not be less than 2 years from the date of purchase. (iii) Date of purchase shall be marked on each fixture with permanent marker for redeeming warranty benefits complete all as specified and directed.
Supply, Installation, testing and commissioning of Ecco Friendly, silent generating set Diesel Engine driven Generating set 30 KVA / 24 KW (CPCV IV ), 0.8 power factor 50 HZ,1500 RPM or nearest higher size, 415 Volts AC, 3 Phase 50 Hz, 4 wire directly coupled alternator and Engine water cooled common base platform with in built fuel tank and including all excavation PCC foundation, anti vibration pads / dampers as per manufacturer instructions and as directed by manufacturer. The DG set shall be factory assembled by the OEM of the engine manufacturer and all components shall be accommodated in enclosure and other accessories comprising of the following :- (Contd...)
Diesel Engine : Eco friendly for emmission and notice (CPCB NORMS-IV COMPLIENCE) Diesel Engine confirming to BS/IS standard devoloping suitable BHP @ the alternator of capcity 30 KVA / 24 KW developing required power for rated KVA not less than 24 KW at 1500 RPM, 3 cylinders Inline, 4 stroke, radiator cooled, continuous duty with 10% overload capacity for any one hour in 12 hours of continuous running and consisting of following :- (a) Radiator cooled (b) Electrical Starter Motor 12V DC. (c) 12V battery 90 AH rating with connecting leads and terminals. (d) Battery Charging Alternator. (e) Fuel System with electroninc governor (f) Fuel flow Spin-on lube oil filter (g) Duel fuel filter with water separator (h) Residential type silencer. (j) Dry type air cleaner (k) Fly wheel and fly wheel housing. (l) First fill of lube oil & Coolent (Contd...)
Alternator : The Alternator shall be of capacity 30 KVA, 24 KW, 415 Volts, at 0.8 pf (lag), 50 Hz, 3 Phase, 4 wire system, suitable for operation at 1500 RPM. The Alternator shall be brusheless type, screen protected, revolving field, self excited, self regulated through an AVR, copper wound, Class 'H' insulation, having +1.0% voltage regulation (max) in static conditions and continuous duty operation.(Contd...)
Mounting Arrangement: Engine and Alternator shall be mounted on a common MS fabricated base frame with Anti Vibration Mounting Pads. Base frame made out off suitable channel mounted on AVM pads as recommended by manufacture. Fuel tank of suitable capacity for contineous 8 Hrs of operation including all connection etc. Provn of DG set foundation as recommended by manufacturer Accoustic enclosure meeting stringer MOEF/CPCB norms-II of 75 dBS @ 1 mtr at 75% load under free field condition with air inlet louvers powder coated. Use of stainless steel hard ware and insulating materials shall meeting IS 8183 insulating materials. Acoustic enclosure shall be as per manufacturer design. (Contd...)
Fuel Tank : Integral fuel tank shall be of capacity not less than 60 Liters and provided with drain plug, air vent, inlet and outlet connection, level indicator and provision. (Contd...)
AMF Panel: AMF Panel of the DG set can be located inside the acoustic enclosure or outside the acoustic enclosure as per manufacturer's standard. The AMF panel shall be totally enclosed, dust, damp and vermin proof, cubicle type free standing floor mounted type made out of 1.6mm / 2.0mm thick CRCA sheet for the panel located inside the acoustic enclosure. If the AMF Panel has to be lcoated outside the acoustic enclosure, the outer shell of the panel should be made out of 3mm thick CRCA sheet and provided with a canopy and the degree of protection shall be IP 54. The AMF Panel should be equipped with the following control gear and components : (a) Power contactor -3/4 pole of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains). (b) MCB / HRC fuse of suitable current rating for short circuit protection. (c) Microprocessor based AMF module incorporating functions :- - Supply failure timer - Restoration timer - 3 Impulse automatic engine start / stop logic - Mains / Generator Voltage & Frequency sensing (Contd...)
SEWAGE DISPOSAL WORKS NOTE:- For items of Sewage Disposal works notes given at the beginning of Sch ‘A’ Part-VII ( Sewage Disposal works) shall also be applicable.
M&L for provision on site RCC hume pipe horizontal type septic tank (10 users) designed to carry sewage and sullage water, including excavation & earth work in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc., complete all as specified & shown on drg No. CEBZ/TD/29/2022 and as directed.
M&L for construction of soakage wells including excavation and earth work in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete type C-2 including intercepting chamber and screen chamber made of brick masonry in CM 1:4, RCC cover slab in M-25/ SFRC cover, interconnecting pipes of RCC/ DWCPE complete filled with brick bats of size 1.2 m dia X 3.00m effective depth complete all as specified and shown in drawing No CEBZ/TD/78/2011 Note :- The rate of earth work i.e. excavation, returning filling and removal of any type of soil is included in this item and nothing shall be paid extra on this account.
COMPOUND WALL, FENCING AND RETAINING WALL) (working in water or liquid mud condition) NOTE:- For items of COMPOUND WALL, FENCING AND RETAINING WALL (working in water or liquid mud condition) notes given at the beginning of Sch ‘A’ Part-X (COMPOUND WALL, FENCING AND RETAINING WALL) (working in water or liquid mud condition) shall also be applicable.
M&L for transportation, fixing, erection and installations etc complete for RCC precast foundations elements for sizes as desired in structural drawing, including curing, transportation, storage, and finally erection at site. This also Includes all labour wages for each stage, machinery, cranes to lift at place at various stages etc including jointing lips and hooks, lifting and fixing arrangements, etc; complete all as specified in PS, Schedule A notes and directed.
M&L for transportation, fixing, erection and installations etc complete for RCC precast wall elements for sizes as desired in structural drawing, including curing, transportation, storage, and finally erection at site. This also Includes all labour wages for each stage, machinery, cranes to lift at place at various stages etc including placement of electrical conduits and switch boxes as per drawing, placement of CPVC pipes 20 mm or 25 mm as per requirement including FTA and MTAs, including jointing lips and hooks, grout couplers if required, GI pipes for dowel bars, providing dowel bars as per design, grouting the joints wherever required, or welding already provided jointing steel bars, making good the joint with epoxy based grout, providing cut outs for doors, windows, vents, sewerage pipes, etc lifting and fixing arrangements, etc; complete all as specified in PS, Schedule A notes and directed. Notes for Item No 8.01 & 8.02 :- The items include only the cost of transportation, fixing, erection and installation of precast elements. The cost of precast elements themselves shall be deemed to be covered under the items catered in Sch ‘A’ Part-XI (COMPOUND WALL, FENCING AND RETAINING WALL) (working in normal condition)
S&F 600/610 mm dia punched tape concertina coil as per IS: 4454 with galvanised coating and punched tape material as per IS:513 deep drawn quality with galvanised coating having medium barbs (bars length: 24+1mm, pitch between two barbs 35+1mm) fixed in position and secured to both sides of shaped angle iron post, stretched to a length of 6 to 8 mm to achieve 600/610mm dia, weighing 8 kg (+5%) as in fencing to steel post and another coil/ MS ribs including fixing with special galvanised fasteners such as J clips C clips U clips all as specified and directed.
COMPOUND WALL, FENCING AND RETAINING WALL (working in Normal condition) NOTE:- For items of COMPOUND WALL, FENCING AND RETAINING WALL (working in Normal condition) notes given at the beginning of Sch ‘A’ Part-XI (COMPOUND WALL, FENCING AND RETAINING WALL) (working in normal condition) shall also be applicable.
M&L for transportation, fixing, erection and installations etc complete for RCC precast foundations elements for sizes as desired in structural drawing, including curing, transportation, storage, and finally erection at site. This also Includes all labour wages for each stage, machinery, cranes to lift at place at various stages etc including jointing lips and hooks, lifting and fixing arrangements, etc; complete all as specified in PS, Schedule A notes and directed.
M&L for transportation, fixing, erection and installations etc complete for RCC precast wall elements for sizes as desired in structural drawing, including curing, transportation, storage, and finally erection at site. This also Includes all labour wages for each stage, machinery, cranes to lift at place at various stages etc including placement of electrical conduits and switch boxes as per drawing, placement of CPVC pipes 20 mm or 25 mm as per requirement including FTA and MTAs, including jointing lips and hooks, grout couplers if required, GI pipes for dowel bars, providing dowel bars as per design, grouting the joints wherever required, or welding already provided jointing steel bars, making good the joint with epoxy based grout, providing cut outs for doors, windows, vents, sewerage pipes, etc lifting and fixing arrangements, etc; complete all as specified in PS, Schedule A notes and directed. Notes for Item No 9.01 & 9.02 :- The items include only the cost of transportation, fixing, erection and installation of precast elements. The cost of precast elements themselves shall be deemed to be covered under the items catered in Sch ‘A’ Part-XI (COMPOUND WALL, FENCING AND RETAINING WALL) (working in normal condition)
S&F 600/610 mm dia punched tape concertina coil as per IS: 4454 with galvanised coating and punched tape material as per IS:513 deep drawn quality with galvanised coating having medium barbs (bars length: 24+1mm, pitch between two barbs 35+1mm) fixed in position and secured to both sides of shaped angle iron post, stretched to a length of 6 to 8m to achieve 600/610mm dia, weighing 8 kg (+5%) as in fencing to steel post and another coil/ MS ribs including fixing with special galvanised fasteners such as J clips C clips U clips all as specified and directed
SUMMER APPLIANCES
Supply and fix plastic body desert cooler electric driven (single phase Motor), Energy efficient including plug top and 3 Core 1.5 Sqmm PVC Copper cable 2 Mtr length having nominal air flow capacity of 5000 Cum per hour (or nearest size) complete all as specified and directed.
M/s Kohli Builders (BID ID -3395426)
Raja enterprises (BID ID -3395649)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tenderdocument.pdf
Tender Documents • 19.22 MB
BOQ.xls
BOQ • 0.75 MB
Tenderdocument_2.pdf
Tender Documents • 23.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .