Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹46.8 L+₹2.3 L (5.11%)Rejected-AOC 219 10 NEW SARVODAY COLONY YADGARPUR MEERUT CITY INDEX NO D 308 HQ CE CC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹48.8 L+₹4.2 L (9.49%)Rejected-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹55.8 L+₹11.3 L (25.3%)Rejected-AOC 283 ALIEN MARKET SADAR KABARI BAZAR MEERUT CANTT UP | L4 | Rejected-AOC Rejected being L4 |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
28 Dec 2021, 6:00 pmClosed
HQ CWE Meerut
HQ CWE Meerut 29J, The Mall Road, Meerut Cantt, UP-250001
SPECIAL REPAIR TO BLDG NO P-201 OF RVC CC BLDG NO T-4 (JCOs OR LINE) BLDG NO P-23 (KENNEL) BLDG NO T-5 AND T-8 (RATION STORE AND MED ORD STORE) AND SPECIAL REPAIR TO DRAINAGE AND SOAKAGE PIT FROM BLDG NO P-145 (OTM ACCN) UPTO MAIN GATE OF CMVL UNDER
2021_MES_489932_1
93994/MRT/2021-22/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents
7 documents required · 7 mandatory
₹1,000
GE (N) Meerut
₹1.2 L
Yes
8 Jan 2022
23 Nov 2021
31 Dec 2021
23 Nov 2021
28 Dec 2021
14 Dec 2021
Amount
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges of any desciption as in roof covering including removal from site complete all as specified and directed.
S&F pre-painted Galvalume aluminium zinc coating (AZ-70) GI based corrugated steel sheet 0.5mm thick of Green colour having a tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
S&F pre-painted Galvalume aluminium zinc coating (AZ-70) GI based plain steel sheet 0.5mm thick of Green colour having a tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
S&F solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame with 5mm thick PVC fillets as per specification complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:6, surface finsihed even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 by using ready mix plaster bags on brick/concrete surfaces of external walls finished even and fair, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed. Make: Ultratech rediplast, Brila Aerocon. Note:- Supply only water proofing compound shall be measured and paid separately. Note: Contractor is required to deposit ready mix bags for 100% CA quantity to the Engr-in-Charge, within 15 days of acceptance of contract.
M&L preparation of new plastered surface of wall by applying two coat of weather coat (Apex) using roller for painting with 3mm thick wall care putty (JK/Birla White) to match with existing finish complete all as specified and directed.
M&L complete removal of existing treatment of wall by mechanical means and applying two coat of oil emulsion distemper using roller for painting over a coat 3mm thick of approved wall care putty (JK/Birla White) complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality and description) from wooden frames or steel, concrete or brick surrounds, glazing with putty or fixed with beads complete all as specified and directed.
S&F in repair 25mm dia, mild steel, curtain rod PVC coated with brackets and side bulbs complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S&F non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L glazed ceramic coloured tiles in vertical surfaces 350 x 250 x 7mm/450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick as backing coat to receive tiles in CM 1:6 complete all as specified and directed.
All as per item No 15.00 above but on vertical surface such as skirting, dados, risers to steps etc including rendering 10 mm thick in CM 1:4.
M&L joint free vitrified ceramic tiles light shade 10mm thick square/rectangular area of each tile not exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for light shade, vitrified tiles, 10mm thick (square/rectangular) area of each tiles exceeding 0.36 Sqm but not exceeding 0.42 Sqm, in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles and over and including 15mm thick screed bedding in CM (1:6) complete all as specified and directed.
M&L 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6) complete all as specified and directed.
M&L 10mm thick screed bed or bedding layer of mortar as backing coat in CM (1:6) complete all as specified and directed.
M&L for preparation of old steel surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L prepration of newly steel surface or previously untreated surfaces of any description, over 10cm in width or grith along with priming with red oxide/zinc chrome primer and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L preparation of old wooden surface of any description, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new plastered surface of wall by applying 3mm thick wall care putty (JK/Birla White) and making the surface smooth and applying two coats of Acrylic Exterior Emulsion paint over one coat of primer using roller for painting complete all as specified and directed.
All as per item No 25.00 above but applying two coats of oil bound distemper over a coat of 3mm thick wall care putty and using roller for painting.
M&L for preparing old plastered surfaces of walls and applying two coat of white wash complete all as specified and directed.
M&L for complete removal of existing treatment by mechanical means and preparation of old decorated surface of walls including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasing spots etc and applying two coats of exterior emulsion paint using roller for painting all as per manufacturers instructions complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
S&F in repair, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed. Make - PRAYAG CASA - Cat Part No-9206, CERA OCEAN Cat Part No – QTF2006151 HTF3001151, PEARL PRECISION PRODUCTS Cat Part No ARI-001.
Taking up or down steel tubing and connections for 15mm bore of pipe including cleaning for re-fixing or removal to store complete all as specified and directed.
S&F CPVC water tubes, medium grade, incl all necessary CPVC fittings, as per site requirement like elbow, tee, nipple, socket, union etc and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed. Make - PRAYAG, Finolex, Kisan.
S&F in repair PVC grating 100mm dia fixed to floor trap complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed. Make - PBC, ECO and EXPERT.
All as per item No 35.00 above but in CM 1:6.
S&F in repairs, vitreous china wash basin, white, flat back of size 550mm x 400mm including brackets waste coupling and waste pipe complete all as specified and directed. Make - PRAYAG SPA - Cat No-4641, CERA CADAL Cat No-S2040121.
Demolition of old water closet including removal of lime concrete bedding, cement concrete bedding in first floor and cleaning the sunken portion and removal the debries from the site complete all as specified and directed.
S&F vitreous china wash down water closet pan, (European Water Closet) integral foot rest or without foot rest including jet spray, seat cover including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc complete complete all as specified and directed.
S&F in repairs, 10 litres capacity, PVC valveless, (plastic polymer cistern) syphonic action type, flushing cistern, low level, white, with inlet ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and directed. Make - PRAYAG VINTAGE - Cat Part No-503, CERA CIENA PREMIUM Cat Part No-B1010102, PEARL PRECISION PRODUCTS CAT No C-001.
Taking down chowkats or frame of any description not exc 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
All as per item No 41.00 above but exc 1.5 Sqm each and not exc 4 Sqm.
S&F anodised aluminium window and ventilator shutters including aluminium grills, side hung type without sash, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, aluminium anodised snap beading, screws, anodise aluminium fittings such as peg stays 150mm long (1 No) hinges type B-21 100 mm long (2 Nos) suitable handle (1 No) complete all as specified and directed.
S&F in repair PVC connection fiber suitable for hot water, reinforced 300mm long with brass check nut and PVC washers at both ends complete all as specified and directed.
S&F in repair towel rail 600 mm complete all as specified and directed. Make Parko, Prayag, GEM
S&F in repair angular valve 15 mm bore dia cast copper alloy CP fency type with long shank and cup screwed down high pressure screwed both ends for iron pipe complete all as specified and directed. Make:- Parko/GEM
Dismantling of wrought iron mild steel work any description not otherwise described and section like purlins, jack rafter, bracing etc complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-400 Gde E-165 complete all as specified and directed.
Demolition cement concrete (unreinforced) in ground floor and pavings not exc 15cm thickness (below or above ground level) complete as specified and directed.
Demolition cement concrete roof padding and pavings not exc 15cm thickness (below or above ground level) complete as specified and directed.
Demolition of concrete of any description and depth in any position complete all as specified and directed.
M&L stone slab (Red stone) 50 mm thick, dressed true and square, in one length not less than 60 cm and n.exc 120cm in copings, window cills, chajjas, sunshades, etc, punched dressed on exposed faces and self faced on the embedded unexposed beds and joints; exposed edges round or chamfered and making good in cement mortar 1:4 filling of edges of walls and joints of stone all as directed, set, jointed and pointed in mortar as in plinth protection complete all as specified and directed.
S&F Chequered cement concrete tiles (Glossy finish in red and yellow colour 50-50% each respectively)in size 400mm x 400mm x 25mm thick, to make covered drain top, set, fixed in MS L angle frame wkand making goodas per site requirement complete all as specified and directed.
M&L for 100mm thick cement concrete type C-2, 1:3:6 (using 40mm gradded crushed stone aggregate) for sub base of paver blocks complete all as specified and directed.
M&L for machine pressed concrete interlocking coloured paver block (50% Red and 50% Yellow) glossy finish any shape, size and colour confirming to IS-15658-2006 of 80mm tickness M-35 grade with grey cement and pigments complete all as specified and directed.
All as per item No 57.00 above but M-40 grade with 50% grey cement and 50% with pigments.
M&L for providing cement concrete type B-1, 1:2:4 (using 20mm gradded crushed stone aggregate) in side of paver blocks rounded on edge complete all as specified and directed.
S&F in repair 15 mm dia Pillar taps/wash hand basin mixer chromium plated, screwed down with high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts complete all as speciied and directed. Make Parko/GEM, PRAYAG CASA- Cat Part No-9260, CERA OCEAN Cat Part No-QT F2006461,PEARL PRECISION PRODUCTS VIRGO CAT NO VIR-187.
M&L for bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of capacity 500 Litres (Cylindrical vertical with closed top), triple layer, white reflective colour, hoisted and fixed in position ISI marked, including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR-Part-I, including disconnecting and removal of old unserviceable PVC tank complete all as specified and directed. Make- Tuff, Sintex neo, Plasto.
S&F for mild steel angle as in rafters rails and fastenings and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Gde E-250) quality A complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples stainless steel wire staple complete all as specified and directed.
Eco- 4000 Series Windows : M&L for Providing and fixing Windows, Ventilators fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality,Galvanized as per IS 277 with Zinc of 120 grams/ Sqr. Mtr.) with total coated thickness of 0.60 mm Paint specifications : Coated Sections should be coated with Primer Coat of Epoxy Primer of 5-7 microns thick, finish painted with Polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns, or Powder Coated with pure Polyester Powder up to 50-60 microns thick. Dimensions of Sections : Sections for Frame should be of 72mm X 50mm, Section for Mullion should be of 72mmX50mm, Section for Shutter Frame should be of 47mm X 20mm, Section for Fixed Glass Bead should be of 12mmX12mm, and Section for Fly mesh should be of 40mm X 20mm. Fixing Details : Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined to the Frame/ Mullion using Nylon cap. Ethyl Propylene Diamine Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Rubber Gasket should be used around Fly mesh to fix Mesh in Mesh Shutter.
Accessories : Each Glazed Shutter should be provided with S.S. Pivot Hinges-1set, Seccolor Handle & Seccolor Stay. Glass : Glazed Shutter and Fixed Glass portions should be provided with a glass of 4/5mm Plain Float Glass. Mesh : Mesh Shutter should be provided with a Stainless Steel 32 gauge Fly mesh of 304 grade with 144 holes per sq. Inch. Windows should be provided with Grill made of 10mm sq. MS Bars welded to at 150mm centre-to-centre, 6mm X 12mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws. Window Frame should be fixed to brick/concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames. Note. The item includes everything as, painting the surfaces, fixing, all necessary accessories, glass, mesh, etc, all as per given specifications, complete all as specified and directed by GE. Make - Bharat Win Solutions or equivalent makes as approved by GE.
S&F for 40mm thick second class hard wood plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), klin seasoned and chemically pressure treated complete all as specified and directed.
S&F 40mm thick, second class hard wood in glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
S&F for framed work Fe-290 (Gde E-165) as in doors chowkats or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
S&F 200mm long mild steel tower bolt stove enamelled black with bright bolt complete all as specified and directed.
S&F 150mm mild steel pressed handles oval type, stove enamelled black complete all as specified and directed.
S&F mild steel sliding door bolts, 250mm long, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
All as per item No 72.00 above but 300mm long.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets, frame, ressian cloth with beads complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling suspension system of size 600mm x 600mm complete all as specified and directed.
S&F non asbestos coloured/white textured designer ceiling board 4mm thick of size 595x595 mm fixing with screws/clips complete all as per manufactures instructions and as directed.
Taking down cement or cement lime plaster/skirting/dado of any description from brick or on stone walls etc including raking out joints hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:6 on brick/concrete surface of inernal walls finished even and fair complete all as specifed and directed.
M&L for applying 15mm thick in CM 1:4 rendering using ready mix plaster bags on brick/concrete surfaces of external walls finished even and fair, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified. Make - Ultratech rediplast, Brila Aerocon. Note:- Supply only water proofing compound shall be measured and paid separately. (Note: Contractor is required to deposit ready mix bags for 100% CA quantity to the Engr-in-Charge, within 15 days of acceptance of contract.
M&L preparation of old plastered surfaces of wall including petty repair with wall care putty and applying one coat of cement base paint using roller for painting complete all as specified and directed.
M&L preparation of old plastered surface of walls including minor repair with wall care putty (JK/Birla White) and applying two coats of oil bound distemper using roller for painting complete all as specified and directed.
Supply only liquid integral water proofing compound.
M&L for mirror polishing to kota stone slab including minor repair to existing kota stone any type in floors and vertical surface complete all as specified and directed.
M&L for 18/19 mm thick block board, grade 1 quality, exterior grade, commercial type, fixed in cup board shutters, shelves etc including fixing off hinges, finishing smooth surface complete all as specified and directed.
S&F teak wood lipping 6mm thick suitable for 18/19mm thick board, fixed with nails complete all as specified and directed.
S&F 40mm dia, cup board knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed.
M&L for 4.8mm thick sheet glass, fixed with rubber gasket beading and aluminium channels in 18/19mm block board shelves and making good as per site requirement and fixing to walls, between RCC shelves etc complete all as specified and directed.
M&L for machine cut kota stone slab size 580 x 580 mm flooring of thickness 18-20mm over 20mm thick cement screed bed of 1:6 CM and jointed with grey cement slurry mixed with pigment to match the shade of slabe of flooring including rubbing & polishing complete all as specified and directed.
All as per item No 88.00 above but on vertical surface as skirting and over 10mm thick rendering in CM 1:4 to receive kota stone.
M&L for cement concrete in surface channels and drain 1:3:6 type C2 (using 40mm graded crushed stone aggregate) complete all as specified and directed.
Extra for forming fair finished drain or channels 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
S&F for welded steel wire fabric complete to wood or steel members complete all as specified and directed.
S&F 1.60mm thick mild steel plian sheet in gate/wall cladding and similar work, cut to size, holes, punched including round headed screws, clout nails or rivets and fixed to wood or steel traming with plain 40mm lap joints with riveted or welded seams including benching or turning up complete all as specified and directed.
Taking down old existing water proofing treatment with roof tiles of any type from top of RCC/arch slab including taking down of concrete padding or plaster and raking out joints of arch slab and hacking the top of RCC slab, cleaning with water and dispose off rubbish upto 200 mtr complete all as specified and directed.
M&L 50 mm thick averaging thickness PCC (1:2:4) type BO, (using 12.5mm graded stone aggregate) as in roof padding finish fair & even complete all as specified.
Surface Preparation: The surface to receive the treatment shall be thoroughly free of laitance, scales, oil or any other loose material. It should be made free of any sharp objects. Cleaning of PCC shall be done with wire brushing to attain smooth levelled surface. Cracks shall be rectified, filled using dual shrinkage compensated Repair Mortar and dried for 72 hours before laying the liquid applied membrane. Grout: Providing Chemical injection treatment in the form of pressure grouting to the construction joint and cracked portion at 1m c/c by injecting cement slurry mixed with dual shrinkage compensated cementitious grout Injection grout additive, in the required consistency through the pre fixed PVC nozzles in the 18 mm dia holes, fixing of PVC nozzles with instant setting cement. Angle fillets/Coving: Providing and making of fillet, 50mm x 50mm on sharp corner of terrace with cement sand polymer mortar (add “multipurpose mortar”, 10% by weight of cement ). First apply the bonding coat of Multi-Purpose Polymer 5-10% diluted in water and add to cement slurry. Apply the bonding slurry and apply the polymer mortar over the sharp edges. Note: Grouting will be done when and where ever required. Treatmnt of pipe entry points: Preparing the inside surface of core and PVC /MS Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Packing the gap using free flowable non shrink cement polymer based grout up to the surface of the bore while the bonding agent is in tacky state. the periphery of PVC pipe should be sealed with Hybrid PU Sealant or dual shrinkage compensated Micro concrete. Note: Will be done when and where ever required.
Application of Asian Paints two component Epoxy Primer (Resin & Hardener) on the cleaned surface for bonding of Polyurethane with the existing concrete surface. 33 % water dilution is recommended with the pure mixed primer. The primer mixing ratio will be 1:3 (Resin:Hardner). Supplying, providing and applying waterproofing treatment to Podium area with single component highly elastomeric seamless cold applied modified PU coating complete as per manufacturer’s specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1mm. The coating shall have a dual combination of 280% elongation. Material coverage 1.2kg /sq.mt. (Note: Contractor deposit 100% material of CA quantity to the Engr-in-Chargewithin 15 days of acceptance of contract).
M&L PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in coping bed block for hold fast, stopper, wheel track, hunching for drain etc complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
Eco- 4000 Series Ventilators/ Windows : M&L for Providing and fixing Windows, Ventilators fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality,Galvanized as per IS 277 with Zinc of 120 grams/ Sqr. Mtr.) with total coated thickness of 0.60 mm Paint specifications : Coated Sections should be coated with Primer Coat of Epoxy Primer of 5-7 microns thick, finish painted with Polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns, or Powder Coated with pure Polyester Powder up to 50-60 microns thick. Dimensions of Sections : Sections for Frame should be of 72mm X 50mm, Section for Mullion should be of 72mmX50mm, Section for Shutter Frame should be of 47mm X 20mm, Section for Fixed Glass Bead should be of 12mmX12mm, and Section for Fly mesh should be of 40mm X 20mm. Fixing Details : Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined to the Frame/ Mullion using Nylon cap. Ethyl Propylene Diamine Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Rubber Gasket should be used around Fly mesh to fix Mesh in Mesh Shutter. Accessories : Each Glazed Shutter should be provided with S.S. Pivot Hinges-1set, Seccolor Handle &Seccolor Stay. Glass : Glazed Shutter and Fixed Glass portions should be provided with a glass of 4/5mm Plain Float Glass.
Mesh : Mesh Shutter should be provided with a Stainless Steel 32 gauge Fly mesh of 304 grade with 144 holes per sq. Inch. Windows should be provided with Grill made of 10mm sq. MS Bars welded to at 150mm centre-to-centre, 6mm X 12mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws. Window Frame should be fixed to brick/concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames. Note. The item includes everything as, painting the surfaces, fixing, all necessary accessories, glass, mesh, etc, all as per given specifications, complete all as specified and directed by GE. Make - Bharat Win Solutions or equivalent makes as approved by GE.
Taking down old existing cement plaster on walls and on sides/top of drain including taking down of concrete surfaces bottom of drain channel including raking out joints hacking for key scrubbing down with cleaning with water and dispose of rubbish upto 200 mtr complete all as specified and directed.
M&L for setting coat 3mm thick in CM 1:2 trowelled to even and smooth finish complete all as specified and directed.
M&L mild steel TMT bars 10mm dia & over cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (annealed) (not less than 0.9 mm dia) or securing with clips quality conforming complete all as specified and directed.
M&L for earth filling (for site development) including raising or lowering not exc 1.5m height earth spreading in layers not exc 30cm thick watering and rolling and finishing to required size etc (earth to be obtained from outside MoD land exc 5km not exc 10km) including excavation complete all as specified and directed.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for foundations etc or for laying cable, shafts, wells, cesspits, manholes, pier holes etc but not exc 10 sqm on plan and not exc 1.5m in depth and desilting of the existing drainage and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Removing of the drainage silt to a distance exc 250m and not exc 500m and dispositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
Loose filling with broken bricks bats on soakage wells complete all as specified & directed.
M&L for brick work with fly ash old size bricks straight or curved on plain exc. 6m mean radius built in CM 1:6 as in mnahole repair, repair to septic tank and soak well/pit etc complete all as specified and directed. Make - PBC, ECO and EXPERT.
M&L for RCC M-25 Design Mix (using 20mm graded crushed stone aggregate) for slab supported on walls, beams and columns in floors, roofs, landings balconies canopies, deck slab and in shelves and the like etc complete all as specified and directed.
M&L flat form work to soffits of suspended slab, such as roof slab floo slab, landing and similar work complete all as specified and directed.
M&L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed.
Taking down carefully any type, battens or conduit point wiring with or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified & directed.
M&L for point wiring with 1.5 Sq mm (nominal cross section area) single core, 1100 volts grade, multi stranded PVC insulated, unsheathed copper conductor,FR, cable in and including in PVC concealed conduit 20 mm dia or higher medium grade ISI marked complete with all steel conduit accessories / fittings and sunk pressed (1.2 mm thick) steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :-
One light/tube light/bulb/street light/fan/exhaust fan point controlled by one, one way switch 05/06 Amps.
One 3 pin 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 amp switch.
One 3 pin 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 amp switch.
M&L for point wiring with 2.5 Sq mm (nominal cross section area) single core, multi stranded PVC insulated, unsheathed copper conductor, FR, cable in and including in rigid PVC conduit 20 mm dia or higher medium grade ISI marked complete with all PVC conduit accessories / fittings and sunk pressed (1.2 mm thick) terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, including earth wire continuous of PVC insulated, unsheathed 2.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :-
One 3 pin socket outlet, 15 Amps with cables 2.5 Sqmm size on independent board, controlled by one, one way 15 Amp switch.
S&F switch piano flush button type, 05/06 Amps single pole, one way 240 volts complete all as specified and directed.
S&F in socket outlet 3/5 pin, 05/06 Amps flush type 240 volts complete all as specified and directed.
S&F in socket outlet 3 pin, 05/06 Amps and 3 pin 15/16 Amps (2 in 1 multipurpose) 240 volts complete all as specified and directed.
S&F switch piano flush button type, 15/16 Amps single pole, one way 240 volts complete all as specified and directed.
S&F socket outlet 3 pin, 15 Amp flush type 240 volts complete all as specified and directed.
S&F lamp holder (Angular/Striaght), insulated body, with back plate complete all as specified and directed.
S&F ceiling rose, surface type, bakelite, 65 x 50 mm, three terminal complete all as specified and directed.
S&F lamp holder insulated body with back plate fix done anodised 100x100mm pressed steel box flush to the wall with 3mm thick backlite cover complete all as specified and directed.
S&F LED tube light fitting T5 surface mounting poly carbonate 240 volts, 20 Watts, 6500K complete all as specified and directed.
All as per item No 124.00 above but 9/10 watts.
Supply and fixing 1x30/45 W LED building security light fitting drawn through and including GI brackets of size 25mm dia bore light grade 1.4 mtr long, bend to shape including MS clamps made out of flat iron of size 32 x 4 mm - 02 Nos and necessary nuts, bolts, washer as required complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed.
S&F decorative wall mounted LED tube light fitting 20 watt with polycarbonate housing with all accessories and fixing material complete all as specified and directed. Make- Philips/Havells/Surya Roshni/Crompton.
S&L XLPE insulated armoured heavy duty electric power cables with aluminium conductor 1100 volts grade cross sectional area of 16 Sqmm 4 core complete all as specified and directed.
All as per item No 129.00 above but 16 Sqmm 2 core.
Supply, laying and testing cable XLPE insulator, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed.
S&F LED lamp 9W 6500K, 240 volts complete all as specified and directed.
M&L for MCB DB double door type SPN 8 way, sheet steel, powder painted, with bus bar neutral link and earth bar etc and fixing MCBs of various rating capacity pole, complete all as specified and directed.
All as per item No 133.00 above but SPN 4 way.
All as per item No 133.00 above but SPN 12 way.
S&F in repair MCCB 4 pole, 125 Amps, 50 Hz, 415 V with rupturing capacity 50 KA with thermal magnetic release complete all as specified and directed.
S&F in repair MCB SP 6 to 32 Amp, AC 240 V, 10 KA complete all as specified and directed.
S&F MCB SPN 40 Amps, 240 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and directed.
S&F in repair isolator DP, 40 Amp, AC, 240 V complete all as specified and directed.
M&L for sub main wiring with 06 Sq mm (nominal cross section area) two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor FR-flexible wiring calbe conforming to IS:694-1990 wih and including continuous earth wire of size 6 Sqmm nominal roll cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25mm dia, PVC conduit accessories/fittings, brass screws, washers etc and connected to common earth dolly including all cutting/chases etc in wall, making good to walls etc including two coats of white/colour washing/distempering etc to the disturbed surfaces to match the exisiting and including taking down old unserviceable submain complete all as specified and directed. Note: - One meter of conduit alongwith 2 runs x 6 Sqmm wire and one 6 Sqmm earth shall be measured as one unit length.
Supply and spreading clean fine dry river sand in trenches for cushioning of under ground cable/cable duct complete all as specified and directed. (Note: Punned thickness shall be measured for the purpose of paymnet).
M&L for fly ash brick protection length of brick shall be laid across the length of cable complete all as specified and directed.
M&L for GI light grade tubing 40mm dia laid in trenches, road crossing, passing through pipe or laid in wall/pole complete all as specified and directed.
S&F sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP-43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempring etc to match the existing disturbed surfaces and taking down MCB's DB's complete all as specified and directed.
S&F MCB, SP, AC, 240 volts "B" series of capacity of 06 to 40 Amps, 10 KA and making connections complete all as specified and directed.
S&F MCB, DP (Double Pole), AC, 240 volts "B" series capacity of 32 to 40 Amps, 10 KA and making connections complete all as specified and directed.
S&F MCCB 4 pole, 100 Amps 16 KA complete all as specified and directed.
S&F vertical loadline sheet metal enclosure double door, triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with provision of 25kA 100 Amp GI frame MCCB with the in built provision for fixing of 1 No MCCB and 12 Nos MCB's inside of DB, with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface with two coats of white/colour washing/distempering etc to match the existing one complete all as specified and directed. Make - Legrand/Schneider/ABB.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 03 of SSR part-I connecting to main switch board/ Main DB's including exacavtion, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm centre to centre both way with suitable lifting handle and pit/ chamber in PCC 1:3:6 type C1, Angle iron 40x40x5mm frame for pit cover including testing on completion, complete all as specified and directed.
veer enterprises
Arun Construction Co.
vibha associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .