Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹22.8 LAccepted-AOC 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹23.8 LRejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹24.5 LRejected-Finance | THIRD | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
12 Nov 2021, 6:00 pmClosed
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIR TO INTERNAL ELECTRIFICATION INCLUDING METERS CEILING FAN GEYSER AND EXTERNAL ELECTRIFICATION INCLUDING FPs DBs LT PANEL CABLE STREET LIGHT AND APFC AT AKASH VIHAR AND SDI UNDER GE AF MARATHAHALLI
2021_MES_482258_1
8913/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) MARATHAHALLI
ALL AS PER ENIT
10 documents required · 10 mandatory
₹500
GE (AF) MARATHAHALLI
₹52,000
Yes
4 Mar 2022
16 Oct 2021
17 Nov 2021
16 Oct 2021
12 Nov 2021
30 Oct 2021
Amount
Taking down unserviceable wire carefully copper/ aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., and making good the disturbed surfaces of walls, ceiling etc., including painting with same colour of the background, complete all as specified and as directed.
Taking down carefully Unserviceable Sub main wiring of any size and type batten or conduit, surface or conceled including removing material from site and making good the disturbed surfaces of walls, roofs etc to match the existing complete all as specified and as directed. Note: Taking down of Fittings and Fixtures shall be measured under respective Items Separately.
Wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories surface type run on walls/ ceiling incl MS terminal boxes mounted concealed on walls with hylam laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket and outlets, fan regulators etc., incl provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. (a) One Light,Fan/Exhaust. fan point controlled by one switch
All as per item no 3 above, but, One light point controlled by 02 two way switches complete all as specified and as directed.
All as per item no 3 above, but,One 5A 2pin/3pin switch socket out let multipurpose on independent Board complete all as specified and as directed.
All as per item no 3 above, but,One 5 Amps socket point on same board with other switches complete all as specified and as directed.
All as per item no 3 above, but,One call bell point controlled by one bell push complete all as specified and as directed.
All as per item No -03 above but wiring complete with 2.5 Sqmm for 5 pin 5/15A socket multipurpose on independent board complete all as specified and as directed. Note :- item No 03 to 04 (i) The earth wire for the points should be in respective switch board only . (ii) Earth wire in the conduit only. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring
S & F Modular Switch 1 way 6 A 1 module complete all as specified and as directed.
S & F Modular Switch 2 way 6 A 1 module complete all as specified and as directed.
S & F Modulur Switch socket out let combination ,3 pin, 5 Amps 230 volts complete all as specified and as directed.
S & F Modular Switch Socket Combination 2 in 1, 5 pin 5 Amps and 15 Amps flush type , 230 volts complete all as specified and as directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5A Flush type 230 volts complete all as specified and as directed.
S & F in repair Socket Outlet 2 in 1, 3 pin, 5 and 15 amp flush type 230 volts complete all as specified and as directed.
S & F in repair Switch Piano Flush type, Single pole, One way 230 volts 15 / 16 Amps complete all as specified and as directed.
S & F in repair step type electronic fan regulator, - 2 module complete all as specified and as directed.
S & F in repair PVC ceiling rose two to three terminals all as specified complete all as specified and as directed.
S & F in repair ding dong bell AC, 230 volts, single pole complete all as specified and as directed.
S&F in repair Angle holder PVC/polycarbonate type complete all as specified and as directed.
Supply and fixing in repair 600x600mm surface/ recessed mounted LED Light fitting 36 /35 W,glare free uniform illumination acrylic diffuser,connector block etc., complete with all accessories and including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed.
Supply and Fixing in repairs LED Tube light fitting 1 x20 W,220V CRCA housing with PC diffuser box type with driver,holder including LED tube light connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed.
Supply and fixing in repair round shape 15 watts 220 volts AC recessed / surface type with high efficiency PMMA diffuser soft glared light complete with drivers ,holders LED lamps including connecting up with 3 core 0. 5sqmm copper wire between ceiling rose and fitting terminal Complete all as specified and as directed.
Supply and fixing LED light fittings 1x10W bulkhead luminaries with drivers ,holders LED lamps including connecting up with 3 core 0. 5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed.
Supply and Fixing in repairs MCB DB SPN 8 way, Double door, 240 V, AC, 50 Hz, with 200Amp rated bus bar complete all as specified and as directed.
Supply and Fixing in repairs MCB SP 5 to 32 Amps rating, 10 KA B 'curve 240V, 50 Hz AC complete all as specified and as directed.
Supply and Fixing in repairs MCB SPN 32 Amps rating, 10 KA 'C 'curve, 240V, 50 Hz AC complete all as specified and as directed.
Supply and Fixing in repairs MCB TP 25- 100 Amps rating, , 10 KA B' curve 415V, 50 Hz AC complete all as specified and as directed.
Supply and Fixing in repairs MCB TPN /FP 40 to100 Amps rating,, 10 KA Çcurve , 415V, 50 Hz AC complete all as specified and as directed.
Material and Labour for sub main wiring 1100 volts grade PVC insulated FRLS multistranded copper conductors, two runs of single core 4 Sqmm along with one run 4 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVC medium grade conduit all as specified and as directed. Note :- 3 run of multistranded copper conductor and 1 run of PVC conduit shall be measured as one unit.
Material and Labour for sub main wiring 1100 volts grade PVC insulated FRLS multistranded copper conductors, two runs of single core 2.5 Sqmm along with one run 2.5 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVC medium grade conduit all as specified and as directed Note :- 3 run of multistranded copper conductor and 1 run of PVC conduit shall be measured as one unit,
Taking out and dismantling all components from ceiling fan existing make 1200mm sweep, cutting and removing burnt out copper winding from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling , greasing to bearing , replacing bushes, replacement of capacitor,inculding fixing in existing position painting of fan with orginal manufactures colour completely testing all as directed. Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan will be measured and paid separately under respective item. (b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and fro from site to work place are deemed to be included in rate quoted.
Taking down dismantling all components Exhaust fan 250mm to 300mm complete of any type and size , cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor, painting of fan with orginal manufactures colour, complete testing including hanging to its orginal position all as directed Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted
Taking down dismantling all components Exhaust fan 400 mm to 450mm complete of any type and size , cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor, painting of fan with orginal manufactures colour and complete testing including hanging to its orginal position all as directed Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted. Note: item No - 31 to 33 - Servicing of fans and Spares will be measured and paid separately under relevant items of this schedule.
Supply Only Ball bearings suitable for Ceiling fans / Exhaust fans / Wall mounting fans of 1200 Sweep complete all as specified and as directed.
Supply Only 2.5 MFD Capacitors for the fan in position complete all as specified and as directed.
Supply Only 4 MFD Capacitors of the fan in position complete all as specified and as directed.
Supply and fix ceiling fans complete with blades, down rod electronic regulator and accessories 230V,1200 mm sweep. Min 6.00 BEE. Five star rated with brushhless directed current motor (BLDC) all as secified and directed
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. complete all as specified and as directed .
Taking out unserviceable geyser element including supply and fixing heating element suitable to existing model and make 1.5 / 2 KW dual clip type/tri angle type / round type with rubber gasket suitable for geysers up to 25 Ltr capacity complete all as specified and as directed.
Taking out unserviceable thermostat including Supply and fixing thermostat clip type (Range 30 C° to 80 C and acting at 70 C°) for geysers up to 50 Lts all as specified and as directed.
Taking out unserviceable PVC connection including supply and fixing 15mm bore PVC connections with brass nuts 650 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser. Complete all as specified and directed .
Taking out unservice pressure release valve Supply and fixing pressure release valves suitable for geyser up to 50 ltrs capacity type asper existing PR valve complete all as specified and directed .
Taking out unservice indication lamp including supply and fixing indicating lamps green / red suitable for geysers up to 50 ltrs complete all specified and directed .
Taking out the unservieable 3 core wire including supply and fix FRLS PVC insulated copper flexible cable 2.5 sqmm , 3 core PVC sheathed,1100 Volts grade complete all as specified and directed .
Excavation in trenches in Soft / Loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient Complete all as specified and as directed.
Returning filling including Spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick Complete all as specified and as directed
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils Complete all as specified and as directed.
Material and labour for riddled Sand Cushioning to cables a layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable Complete all as specified and as directed. Note :- Sand shall be measured after punned down.
S & F sub class burnt Bricks for cable protection Complete all as specified and as directed
S&F G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings / culverts complete all as specified and as directed.
Boring of holes under roads,pavement,hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Taking out old unserviceable UG cable including supply and laying 240 Sqmm, 3.5 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning complete all as specified and as directed.
Taking out old unserviceable UG cable including supply and laying 70 Sqmm, 3.5 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Taking out old unserviceable UG cable including supply and laying 50 Sqmm, 3.5 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Taking out old unserviceable UG cable including supply and laying 35 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning complete all as specified and as directed.
Taking out old unserviceable UG cable including supply and laying 16 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning complete all as specified and as directed.
Taking out old unserviceable UG cable including supply and laying 10 Sqmm, 2 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning complete all as specified and as directed.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 16 to 35, Sqmm 3.5 / 4 core complete all as specified and as directed.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 50 to 95, Sqmm 3.5 / 4 core Complete all as specified and as directed. Note for ser item No.58 & 59 (i) Earth work excavation, sand cushioning, bricks for protection, GI pipe etc shall be measured and paid for separately under relevant items of this schedule.
Supply and Fixing in repairs MCCB Triple pole 415 volts 50 HZ AC suitable for current carrying capacity 25 to 100 Amps rating, fixed type with rupturing capacity 16 KA all as specified and directed.
Supply and Fixing in repairs MCCB 3 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 160 Amps rating, fixed and thermal magnetic release with rupturing capacity 25 KA all as specified and directed.
Supply and Fixing in repairs MCCB 4 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 200 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA all as specified and directed.
Supply and Fixing in repairs MCCB 4Pole, 415 volts 50 HZ AC suitable for current carrying capacity400 Amps rating, fixed and thermal magnetic release with rupturing capacity 36 KA all as specified and directed.
Supply and fixing moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as directed
Supply and Fixing in repairs voltmeter digital type 0-500 Volts Complete all as specified and as directed.
Supply and Fixing in repairs Ammeter digital type 0-200 Amps Complete all as specified and as directed.
Disconnecting the electrical connections including taking down the unserviceable LED Street light fittings of 75/45/25 watts of any type and any make from pole for repair and replacement of unserviceable parts like driver, surge protection & required size wiring etc , and fixing back to the original position after getting repairs including connecting testing and commissioning all as specified and directed .
Material and Labour for preperation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint including welding & replacing door inches complete all as specified and as directed.
Supply and laying synthetic rubber insulating Mats suitable for 11 KV electrical insulation 2 Mtr x 1 Mtr x 2.5 mm thick complete all as specified and as directed.
Taking out the unserviceable HPSV /CFL street light fitting any watts , Supply and fixing 1x 60 W LED street light fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection complete all as specified and as directed.
Taking out the unserviceableflood light fittings Supply and fixing 1x70 W LED flood light fitting 230V out door type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistants complete with driver and lamp complete all as specified and as directed.
Taking out the unserviceable post top latern fitting ,Supply and Fixing post top lantern LED type 20 W 230 Volts AC out door type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant Complete with driver and lamp complete all as specified and as directed.
Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth earth strip 25 x 4 mm by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in Electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., Complete all as specified and as directed.
Supply Only in repairs10/12. 5 KVAR Capacitor heavy duty existing make and type 440 volts with inrush current Limiting Coil Complete all as specified and as directed.
Supply Only in repairs 20 KVAR Capacitor heavy duty existing make and type 440 volts with inrush current Limiting Coil Complete all as specified and as directed.
Supply Only Automatic power factor relay ( APFCR ) 8 stage Complete all as specified and as directed.
Supply only duty contactor suitable for 20Kvar capacitor Complete all as specified and as directed.
Supply only duty contactor suitable for 12.5 Kvar capacitor complete all as specified and as directed.
S & F switch piano flush type, single pole, one way 5 Amps complete all as specified and as directed.
S & F in repair Switch socket combination 2 -in-1, 3 pin/5 pin, 5 Amps 230 volts complete all as specified and as directed.
S & F in repair Switch Socket Combination 2 in 1, 3 pin 5 Amps and 15 Amps flush type , 230 volts complete all as specified and as directed.
S & F in repair Modular Switch 1 way 6 Amps 1 Module complete all as specified and as directed.
S & F in repair Modular Socket,6 Amps- 2/3 pin combined 2 Moduler complete all as specified and as directed.
S & F in repair Modular Switch 1 way 16 Amps 1 Moduler complete all as specified and as directed.
S & F in repair Modular Socket,6 A/16A,2 Moduler complete all as specified and as directed.
S & F in repair Modular type Fan step regulator 120W type 2 moduler complete all as specified and as directed.
Supply and fixing LED light fitting 40 W recessed & surface LED 1X4 Flat Panel ceiling light with high performance, with in built driver, complete with all accessories and including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed.
Supply and Fixing in repairs Aesthetically designed linear mirror light with high output PMMA diffuser for glare free light LED light fitting 1 x 10 W with all accessories and including connecting up complete all as specified and as directed.
Supply and Fixing in repairs retro type LED in built driver,linear T8 tubler lamp 20 W complete all as specified and as directed.
Supply and Fixing in repairs retro type LED in built driver, linear T8 tubler lamp 9 W complete all as specified and as directed.
Supply and Fixing in repairs LED linear T5 tubler lamp 18 W complete all as specified and as directed.
Supply and Fixing in repairs MCB DB TPN 4 way, double door,415 V, AC, 50 Hz, complete all as specified and as directed.
Supply and Fixing in repairs MCB TP 25- 63 Amps rating, , 10 KA Ç' crve 415V, 50 Hz AC complete all as specified.
Supply and Fixing in repairs MCB TPN 63 Amps rating,, 10 KA Çcurve , 415V, 50 Hz AC complete all as specified and as directed.
Taking out and dismantling all components from ceiling fan existing any make 1200mm sweep, cutting and removing burnt out copper wining from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling , greasing to bearing , replacing bushes, replacement of capacitor,inculding fixing in existention of required length of rod for false ceiling addition position painting of fan with orginal manufactures colour, extesion of rod completely testing all as directed. Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan will be measured and paid separately under respective item. (b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and fro from site to work place are deemed to be included in rate quoted.
Taking down dismantling all components Exhaust fan 250mm to 300mm complete of any type and size , cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor, painting of fan with orginal manufactures colour, complete testing including , fixing in its existing position with all new fitting & fixtures, complete all as specified and as directed. NOTE:- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bolts/nuts and transportation to and from site to work place are deemed to be included in rate quoted
Disconnecting the power supply and taking down the exhaust fan dismantling the defective fans motor up 400 to 450 mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, and other petty items required for making motor functional, fixing in its existing position with all new fitting & fixtures, complete all as specified and as directed.
Supply and fix wall mounting fans complete with all its orginal acessories in put 90 to245V,400 mm sweep RPM 1350 energy efficent. directed current motor (BLDC) all as secified and directed
Disconnecting the power supply and taking down the wall mounting fan 300 to 450 mm , taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, and other petty items required for making motor functional , fixing in its existing position with all new fitting & fixtures, complete all as specified and as directed. Note: Item No -99 to 100 - Servicing of Exhaust fans and Spares will be measured and paid separately under relevant items of this schedule.
Supply Only GM bush & clamp assembly suitable for Ceiling fan 1200 Sweep complete all as specified and as directed.
Supply only ball bearings suitable for Ceiling fans / Exhaust fans / Wall mounting fans of 1200 Sweep complete all as specified and as directed.
Supply Only 2.5 MFD Capacitors for the fan in position Complete all as specified and as directed.
Supply Only 4 MFD Capacitors of the fan in position complete all as specified and as directed.
Taking out old unserviceable UG cable including supply and laying 95 Sqmm, 3.5 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning complete all as specified and as directed.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size Upto 35, Sqmm 3.5 / 4 core complete all as specified and as directed.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 50 to 95, Sqmm 3.5 / 4 core Complete all as specified and as directed. Note for ser item No.106 & 107 (i) Earth work excavation, sand cushioning, bricks for protection, GI pipe etc shall be measured and paid for separately under relevant items of this schedule.
Supply and Fixing in repairs MCCB 4Pole, 415 volts 50 HZ AC suitable for current carrying capacity 250 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA complete all as specified and directed.
Supply Only in repairs of 25 KVAR Capacitor heavy duty existing make and type 440 volts with inrush current Limiting Coil complete all as specified and as directed.
RRK PROJECTS
Chandana Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .