Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC AT GURUDWARA NEAR UCO BANK PO SOUTH BLANDA TALCHER DIST ANGUL | TALCHER | ANGUL | ODISHA | 759116 | L1 | Accepted-AOC techno-commercially eligible L-1 bidder. | |
| 2 | L2₹13.5 L+₹2.1 L (18.1%)Rejected-Finance AT BAGHUABOL CHHAK PO HATATOTA TALCHER ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L2 | Rejected-Finance Rejected due to not becoming techno-commercially eligible L-1 bidder. |
| Sl No | Description | Qty | Unit | M/s Evergreen Electrical Works L1 | M/S INDUSTRIAL ENGINEERING WORKS L2 |
|---|---|---|---|---|---|
| 1.00Item Description/ Heading | |||||
| 1.01Winding temperature indicator (WTI) (Department Supply) (Quantity: 02 Nos.) | |||||
| 1.02Oil temperature indicator (OTI) (Department Supply) (Quantity: 02 Nos.) | |||||
| 1.03Supply of resistor unit wound in cylinder porcelain insulator with steel clamps, Nuts, Bolts at both end having resistance value 6.5 ohm each. (Department Supply) (Quantity: 12 Set.) | |||||
| 1.04Vacuum Interrupter (Department Supply) (Quantity: 06 Nos.) | |||||
| 1.05IDMT Relay, 3 O/C & 1 E/F Relay, Aux. voltage 110 V AC/DC (Department Supply) (Quantity: 03 Nos.) | |||||
| 1.06Oil dash pot type overload relay (Department Supply) (Quantity: 10 Nos.) | |||||
| 1.07Single phase Preventer (Department Supply) (Quantity: 05 Nos.) | |||||
| 1.082.5 sq.mm PVC insulated flexible multi stranded copper cable(90mtrs/ Roll) (Department Supply) (Quantity: 05 Rolls.) | |||||
| 1.091.5 sq.mm PVC insulated flexible multi stranded copper cable(90mtrs/ Roll (Department Supply) (Quantity: 05 Rolls.) | |||||
Tender Value
₹21.6 L
EMD Value
₹27,100
Closing Date
13 Jun 2025, 5:00 pmClosed
STAFF OFFICER (ENM), HINGULA AREA
STAFF OFFICER(ENM), OFFICE OF THE GM HINGULA AREA, MCL, TALCHERPO NS NAGAR, ANGUL, ODISHA, 759148
Complete repairing, maintenance and attending Emergency breakdown of Electrical installation such as of 04 Nos. of 33 KV, 800 Amps MOCBs and all 33 KV CTs, PTs, all GOAB, Busbar etc. and 11 Nos. of 6.6 KV control panel VCBs , 02 Nos. of 400 Amps etc
2025_MCL_336390_1
MCL/GM/HA/EnM/ e-Tender/25-26/132 Dt.28.05.25
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
BALRAM OCP
AS PER NIT
5 documents required · 5 mandatory
₹27,100
16 Oct 2025
29 May 2025
16 Jun 2025
29 May 2025
13 Jun 2025
30 May 2025
29 May 2025 - 2 Jun 2025
Amount
Item Description/ Heading
Winding temperature indicator (WTI) (Department Supply) (Quantity: 02 Nos.)
Oil temperature indicator (OTI) (Department Supply) (Quantity: 02 Nos.)
Supply of resistor unit wound in cylinder porcelain insulator with steel clamps, Nuts, Bolts at both end having resistance value 6.5 ohm each. (Department Supply) (Quantity: 12 Set.)
Vacuum Interrupter (Department Supply) (Quantity: 06 Nos.)
IDMT Relay, 3 O/C & 1 E/F Relay, Aux. voltage 110 V AC/DC (Department Supply) (Quantity: 03 Nos.)
Oil dash pot type overload relay (Department Supply) (Quantity: 10 Nos.)
Single phase Preventer (Department Supply) (Quantity: 05 Nos.)
2.5 sq.mm PVC insulated flexible multi stranded copper cable(90mtrs/ Roll) (Department Supply) (Quantity: 05 Rolls.)
1.5 sq.mm PVC insulated flexible multi stranded copper cable(90mtrs/ Roll (Department Supply) (Quantity: 05 Rolls.)
Copper Flat/Busbar (Department Supply) (Quantity: 30 Meter.)
Aluminum lug socket & Copper lug Socket (Department Supply) (Quantity: 01 LS.)
Tripping coil,50 Volts DC
Closing coil ,50Volt DC
Gasket
Crank Assembly
Dual Lever
Releasing lever Assembly
Upper Terminal (New type)
Lower Terminal (New type
Moving contact rod assembly
Upper fixed contact assembly
Trip Catch Assly.
Closing spring Assembly
Rupturing chamber cylinder
Closing Catch Lever Frame Assly.
Tripping coil Assly. (50 V DC)
Lower Housing Assly. Old type
Catch Lever Assembly
Complete set of Baffles with Tubular sleeves and Partition(in sets) consisting of (a) Top baffles assly. (b) Partition (c) Lower Baffle (d) Intermediate baffle (e) Tubular sleeve
HT aluminum bushing connector for CT
HT rubber seal bushing for CT secondary
Heavy duty Aluminum pad for 50mm Dia. Busbar to CT bushing stud.
HT oil seal for PT
Neoprine type oil cork sheet of size 900 mm× 600 mm, 8mm thick
Rubber bush
Bushing stud with Nuts and washers(For 33 KV Side)
Bushing stud with Nuts and washers(For 6.6 KV Side)
Neoprine type oil cork sheet of size 900 mm× 600 mm, 10 mm thick
Buch-holtz Relay complete set
Breather
Silica Gel
Mercury switch for WTI and OTI
Fiber Display cover
Glass plate for WTI & OTI
Twin core cable
Core balance current Transformer(CBCT) (Required for NGR, Field switch and VCB control panel)
Auxiliary contactor Relay, Coil voltage 24 V DC, 3 NO+1NC type
Support insulator
Push Buttons with accessories (Required for NGR control panel, VCB control panel and Field switches )
Indication lamp Assembly (for NGR control panel, VCB control panel and Field switches )
Supply of 45 Amps ,6.6 KV Grade HRC fuse
Copper Pig tail with sockets fitted at both ends for GOAB, Each 2.5 ft long
High tension bolt with Nut size 3’’ long for GOAB switches.
Aluminum pad(pipe to pipe) straight type 50 mm dia. (08 bolt Type)
Aluminum pad(pipe to pipe) 90 ˚ bend 15 mm dia. (08 bolt Type)
Aluminum pad connecting pipe 50mm Dia. to DOG conductor, 10 Bolt type
Aluminum pad connecting 33 KV GOAB to 50mm Dia. Busbar straight (08 Bolt Type)
Aluminum pad connecting 33 KV GOAB to 50mm Dia. Busbar 90 ˚ bend (08 Bolt Type)
Female/Fixed contact of 33KV, 1200 Amps, Double break knife type
Male/Moving contact of 33KV, 1200 Amps, GOAB switch
Post insulator of 22 KV grade
Female/Fixed contact of 11KV, 800 Amps, Double break knife type
Male/Moving contact of 11KV,800 Amps, GOAB switch
33 KV 1200 amp Rotating unit spindle
11 KV 800 amp Rotating unit spindle
Petroleum jelly, Emery paper and Cotton waste etc. for GOAB switch maintenance
Fixed contact Block Assembly, 400Amps with tip for OCB
Moving contact(poker), 400 Amps for OCB
HT fiber Arc chute for OCB
HT fiber connecting bar for OCB
Auxiliary switch Assembly
Shunt trip coil Assembly
Electrical release coil Assembly
Earth Leakage Relay
Rectifier capacitor unit, 63 Amp
Auxiliary contactor ,110V AC, 2 NO +2 NC
Ammeter, 96 sq.mm
Voltmeter, 96 sq.mm
Fuse base & carrier
TNC switch
Control Fuse
Master Trip Relay, 110 V DC
Auxiliary spares such as ferrules, control lugs, sleeves, cotton waste etc.
Resistance
PLA Relay
HT HRC fuse for PT
Nuts, Bolts, washers, PVC tape, dendrite etc.
Fibre Glass barrier set for Isolator
Complete checking, dismantling, oil draining (wherever required), repairing, re-assembly, maintenance and attending Emergency breakdown of Electrical installation such as of 04 Nos. of 33 KV, 800 Amps MOCBs and all 33 KV CTs, PTs, all GOAB, Busbar etc. and 11 Nos. of 6.6 KV control panel VCBs , 02 Nos. of 400 Amps OCBs with all capacitors, all Power Transformers and their NGRs, all Lightning arresters and 11 Nos. field switches (in mines pump house and other locations) including checking of all faulty equipments, checking their connections & rewiring of control circuits and all other electrical equipment & accessories related to 33 KV, 14 MVA main Sub-station of Balram OCP for one Calendar Year. (Requirement of 1 (One) skilled, 1 (One) Semi-skilled, 2 (two) un-skilled persons for a period of one year excluding Sundays and Paid Holidays).
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S INDUSTRIAL ENGINEERING WORKS (BID ID -1159276)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .