Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC SARJU VILLA 5A KHALISA KOTA PALLY KOLKATA 700051 | KOLKATA | KOLKATA | WEST BENGAL | 700051 | ₹2.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.7 LRejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 UDYAM WB 23 0013338 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | ₹2.7 L | L2 | Rejected-Finance Higher than L1 |
| 3 | L3₹2.7 LRejected-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | ₹2.7 L | L3 | Rejected-Finance Higher than L1 |
| 4 | L4₹2.8 LRejected-Finance 7G CORNFIELD ROAD KOLKATA 700019 | PASCHIM BARDHAMAN | WEST BENGAL | 713305 | ₹2.8 L | L4 | Rejected-Finance Higher than L1 |
| Sl No | Description | Qty | Unit | DEY ENTERPRISE L2 | EASTERN INDIA SALES AND SERVICE L3 | System Advance Technologies (P) Ltd. L1 | CONCORD ENGINEERING L4 |
|---|---|---|---|---|---|---|---|
| 1.00Supply and delivery of 4 Core Armoured Optical Fiber Cable as per following specifications :- | |||||||
| 2.00 | i) Fiber/Tube identification : Color coded Central Strength: Member : Glass Reinforced Plastic (GRP)
Fiber Protection (Tube) : Polybutylene Terephthalate (PBT)
Fillers : As required
Water Blocking : Thixotropic Gel (Tubes)/ Petroleum Jelly (Interstices)
Core Wrapping : Polybutylene Terephthalate Tape
Sheath : Polyethylene (UV Stabilised)
Jacket : Nylon (UV Stabilised)
Fiber Count (up to) : 6
Tube Diameter (mm) : 2
Nominal Diameter (mm) : 9.6
Nominal Weight (Kg/km) : 70
Maximum Tension (kN) Installation : 2.3, In Service : 1.3
Maximum Crush Resistance (kN/100mm) : 1.6
Minimum Bend Radius (mm) Under Load : 20 x OD
Storage Temperature : -40°C to +70°C
Operating Temperature : -40°C to +70°C
MFD @ 1310nm : 9.2 ± 0.4mm
Cladding Diameter (mm) : 125 ± 0.7
Fiber Coating Diameter (mm) : 250 ± 10
(Make-Molex/Legrand/Lapp/Approved Make) | 700 | Mtr | 50 ₹35,000 | 51 ₹35,700 | 49 ₹34,300 | 52 ₹36,400 |
| 3.00 | Repairing of Local Area Network by laying HDPE pipe at the damaged segments from nearest pith to pith, pulling the OFC cable through HDPE pipe and some through aerial root by hanging stay wire by supplying necessary sundry items followed by commissioning of 4 Core OFC by splicing with Pigtail of approved make. This includes the cost for OTDR Testing to be done during commissioning to check the Link Quality. (N.B - i) The OTDR Report should be submitted after commissioning of Link. ii) Vendor will be responsible to completely up the repair Link with the existing running Link and check the packet drop at specified Load.) | 650 | Mtr | 151 ₹98,150 | 150 ₹97,500 | 149 ₹96,850 | 149 ₹96,850 |
| 4.00 | Dismantling the Guy Mast Tower of 51 m Height and shifting to the store house by engaging competent manpower and using necessary T&P, ensuring proper safety precautions. The Tower should be dismantled section wise with proper precaution of safety and security of workers. | 1 | Item | 22,000 ₹22,000 | 25,000 ₹25,000 | 20,000 ₹20,000 | 30,000 ₹30,000 |
| 5.00Supply, delivery and fitting fixing of the following materials at site :- | |||||||
| 5.01 | 5 Port POE Switch with 100 MBPS Both end Media Converter.(Make-Digilink/D-Link/Optilink/Approved Make) | 3 | Eaxch | 19,500 ₹58,500 | 20,500 ₹61,500 | 19,500 ₹58,500 | 21,000 ₹63,000 |
| 5.02 | 1KVA Backup UPS with Battery. (Make-APC/Luminus/Approved Make) | 3 | Each | 3,100 ₹9,300 | 3,050 ₹9,150 | 2,600 ₹7,800 | 3,100 ₹9,300 |
| 6.00 | Add GST @ 18% | 1 | Item | - | - | - | - |
| 7.00 | Add CESS @ 1% | 1 | Item | - | - | - | - |
Tender Value
Refer Docs
EMD Value
₹5,500
Closing Date
12 Jul 2025, 4:00 pmClosed
Executive Engineer SMD PHE Dte
Chetla
Repairing/Replacement works in connection with retrieving the OFC links between different gates and the CCR at Dakshin Roypur Water Supply Project 34MGD under South 24-Pgs Mechanical Division, PHE Dte.
2025_PHED_862214_7
WBPHE/EE/SMD/NIeT-11 of 2025-26
Open Tender
Miscellaneous Works
45 days
Dakshin Roypur
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,500
27 Apr 2026
24 Jun 2025
14 Jul 2025
24 Jun 2025
12 Jul 2025
24 Jun 2025
Amount
Supply and delivery of 4 Core Armoured Optical Fiber Cable as per following specifications :-
i) Fiber/Tube identification : Color coded Central Strength: Member : Glass Reinforced Plastic (GRP) Fiber Protection (Tube) : Polybutylene Terephthalate (PBT) Fillers : As required Water Blocking : Thixotropic Gel (Tubes)/ Petroleum Jelly (Interstices) Core Wrapping : Polybutylene Terephthalate Tape Sheath : Polyethylene (UV Stabilised) Jacket : Nylon (UV Stabilised) Fiber Count (up to) : 6 Tube Diameter (mm) : 2 Nominal Diameter (mm) : 9.6 Nominal Weight (Kg/km) : 70 Maximum Tension (kN) Installation : 2.3, In Service : 1.3 Maximum Crush Resistance (kN/100mm) : 1.6 Minimum Bend Radius (mm) Under Load : 20 x OD Storage Temperature : -40°C to +70°C Operating Temperature : -40°C to +70°C MFD @ 1310nm : 9.2 ± 0.4mm Cladding Diameter (mm) : 125 ± 0.7 Fiber Coating Diameter (mm) : 250 ± 10 (Make-Molex/Legrand/Lapp/Approved Make)
Repairing of Local Area Network by laying HDPE pipe at the damaged segments from nearest pith to pith, pulling the OFC cable through HDPE pipe and some through aerial root by hanging stay wire by supplying necessary sundry items followed by commissioning of 4 Core OFC by splicing with Pigtail of approved make. This includes the cost for OTDR Testing to be done during commissioning to check the Link Quality. (N.B - i) The OTDR Report should be submitted after commissioning of Link. ii) Vendor will be responsible to completely up the repair Link with the existing running Link and check the packet drop at specified Load.)
Dismantling the Guy Mast Tower of 51 m Height and shifting to the store house by engaging competent manpower and using necessary T&P, ensuring proper safety precautions. The Tower should be dismantled section wise with proper precaution of safety and security of workers.
Supply, delivery and fitting fixing of the following materials at site :-
5 Port POE Switch with 100 MBPS Both end Media Converter.(Make-Digilink/D-Link/Optilink/Approved Make)
1KVA Backup UPS with Battery. (Make-APC/Luminus/Approved Make)
Add GST @ 18%
Add CESS @ 1%
DEY ENTERPRISE (BID ID -6645320)
EASTERN INDIA SALES AND SERVICE (BID ID -6647325)
CONCORD ENGINEERING (BID ID -6703536)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tendernotice_2.pdf
PDF • 1.13 MB
BOQ_1953990.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid