Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹8.7 L+₹66,923 (8.31%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹9.0 L+₹94,273 (11.7%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L3 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
10 May 2025, 6:00 pmClosed
AGE (I) Fatehgarh
AGE (I) Fatehgarh
REPAIR/MAINT AND REPLACEMENT OF GI PIPE LINES CONTROL VALVES AND OTHER MISC WORK OF OTM AND MD ACCN AT SIKH LI FATEHGARH
2025_MES_703530_1
AGE(I)/FAT/ET-70 OF 2024-2025
Open Tender
Miscellaneous Works
Works
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Fatehgarh
₹20,000
Yes
11 Jun 2025
4 Apr 2025
16 May 2025
4 Apr 2025
10 May 2025
18 Apr 2025
4 Apr 2025 - 17 Apr 2025
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth and getting out for taking up and laying of pipe in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 Cms in soft/loose soil all as specified and directed
Removing excavated material (soil) n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
Taking up or down 15 mm bore steel water tubing and connections from trenches/floor /walls /Ceiling of following sizes and grade, including cleaning for re-fixing or removal to store,complete all as specified and as directed.
All as per item above here-in-before but for size 20 mm bore….ditto as above
All as per item above here-in-before but for size 25 mm bore…ditto as above…
All as per item above here-in-before but for size 40 mm bore…ditto as above….
All as per item above here-in-before but for size 50 mm bore…ditto as above…
Supply & Fixing 15 mm bore galvanized steel tubing , medium grade with all fittings and fixed to walls , ceilings or laid in floors, trenches complete as per IS 1239 Part-II complete all as specified and as directed.
All as per item above here-in-before but for size 20 mm bore…ditto as above…
All as per item above here-in-before but for size 25 mm bore …ditto as above…
All as per item above here-in-before but for size 40 mm bore …ditto as above…
All as per item above here-in-before but for size 50 mm bore …ditto as above…
Re-fixing only 15 mm bore galvanized steel tubing , medium grade with all fittings in trenches,ceilings,walls, floors complete all as specified and as directed.
All as per item above here-in-before but for size 20 mm bore …ditto as above…
All as per item above here-in-before but for size 25 mm bore …ditto as above…
All as per item above here-in-before but for size 40 mm bore…ditto as above…
All as per item above here-in-before but for size 50 mm bore …ditto as above…
Supply and mixing of Calcium Hypochlorite (65-70%) in plastic container complete all as specified and as directed.
Supply and mixing of Sodium Hypochloride in plastic container complete all as specified and as directed.
Supply and mixing of Poly Aluminium Chloride complete all as specified and as directed.
Supply and mixing of Poly Electrolite complete all as specified and as directed.
Supply and mixing of Alum Ferric complete all as specified and as directed.
Supply and mixing of Soda Ash complete all as specified and as directed.
Supply and mixing of Trichloroisopsynuric Acid (TCCA) (90%) complete all as specified and as directed.
Supply and mixing of Bleaching Powder complete all as specified and as directed.
Supply and mixing of Copper Sulphate complete all as specified and as directed.
M&L in replacement of 100 mm dia sluice valve class PN-1.6 heavy duty flanged ends drilled , ISI-marked confirming to IS:14846 suitable for following bore pipe, wheel oprated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve incl. making arrangement for safe working complete all as specified and as directed.
All as per item above here-in-before but for size 150 mm dia…ditto as above…
Supply & fixing in replacement 15 mm dia of Gun-metal , globe or gate Valves, with iron wheel head , screwed both ends for iron pipe and fixed complete all as specified and as directed.
All as per item above here-in-before but for size 20 mm dia…ditto as above…
All as per item above here-in-before but for size 25 mm bore…ditto as above…
All as per item above here-in-before but for size 40 mm bore…ditto as above…
All as per item above here-in-before but for size 50 mm bore…ditto as above…
S & F for drilling hole in existing CI/GI water main (in any position) and making arrangement for tapping water connection for 15 /20/25 mm with and including mild steel clamp of size 50 x 6 mm in existing CI/DI/GI pipeline any size,dia. with necessary nut bolts,GI tubing up to 1.5 metre long with required fittings and necessary welding works ,gasket etc complete all as specified and as directed.
Leakage detection in GI water mains 15/20/25 mm bore and carrying out necessary repairs including cutting, reducing for insertion of GI fittings such as Tee, Bends, reducer, elbow, nipple, union, long screw etc incl welding, all as required at site including Excavation, returning, filling in and removal of excess spoil complete all as specified and as directed. Note :- Rates quoted will be deemed to be inclusive of all fittings and nothing extra will be paid.
Leakage detection in GI water mains 40/50 mm bore and carrying out necessary repairs including cutting, reducing for insertion of GI fittings such as Tee, Bends, reducer, elbow, nipple, union, long screw etc including welding, all as required at site including Excavation, returning, filling in and removal of excess spoil complete all as specified and as directed. Note :- Rates quoted will be deemed to be inclusive of all fittings and nothing extra will be paid.
Leakage detection in GI water mains 80 mm bore and carrying out necessary repairs including cutting, reducing for insertion of GI fittings such as Tee, Bends, reducer, elbow, nipple, union etc including welding, all as required at site including Excavation, returning, filling in and removal of excess spoil complete all as specified and as directed. Note :- Rates quoted will be deemed to be inclusive of all fittings and nothing extra will be paid.
M/S S P CONSTRUCTION (BID ID -3294493)
M/S CHAUHAN ELECTRIC WORKS (BID ID -3286168)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .