Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹35.4 L+₹1.6 L (4.61%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹35.6 L+₹1.7 L (4.99%)Rejected-Finance 2ND CROSS DEEN STREET M G ROAD JUNGLIGHAT POST SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹36.6 L+₹2.7 L (7.88%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹37.9 L+₹4.0 L (11.8%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
28 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo, Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
CLEANING, REPLACEMENT AND REPAIR OF SEPTIC TANK, SEWAGE LINE, MANHOLES AND REPAIR / MAINT WORK TO ATTEND DAY TO DAY COMPLAINTS UNDER AGE B/R-I OF GE HADDO
2023_MES_622374_1
8785/GE/H/PB
Open Tender
Civil Works
Item Rate
270 days
GE Haddo Port Blair
Class D and Category a(ii)
9 documents required · 9 mandatory
₹500
GE Haddo
₹68,000
Yes
27 Dec 2023
9 Oct 2023
4 Nov 2023
9 Oct 2023
28 Oct 2023
23 Oct 2023
10 Oct 2023 - 20 Oct 2023
Amount
Removing and Cleaning out blockage of Water Closet including WC trap of any description and in any position by removing sand / sludge / silt and other foreign material deposited in it (either manually or mechanically) upto first manhole and making the sewerage system functional to the entire satisfaction of Engg-in-charge complete all as specified and as directed
Removing and Cleaning out blockage from traps of bathrooms / kitchen sink / wash basin / Urinal point and gully traps of any description and in any position by removing sand / sludge / silt and other foreign material deposited in it (either manually or mechanically) upto first manhole and making the sewerage system functional to the entire satisfaction of Engg-in-charge complete all as specified and as directed
Taking out carefully the cover slab of gulley traps of any size, shape, depth and cleaning the block by removing the scum / sludge / any material to a distance exc 250m and n exc 500m and cleaning with fresh water including placing the cover slab / grating in position complete all as specified and as directed by Engg-in-Charge.
Cleaning of sewage line of any dia using passing rubber ball through line to ensure all blockage perfectly clear or split bamboo with a gunny bag piece tied with bamboo with binding wire and inserting the bamboo in sewage line through manhole/gully trap for clear flow of sewage in sewage pipe line complete all as specified and directed
Sucking of sewage water from septic tank / soakage well etc of any size and depth by mechanical means i.e., suction pumping sets etc and removing the muddy water in liquid or semi-liquid state and removing to a distance exc 500m and n.exc 5.0km. The muddy sewage water to be disposed off in closed container and to be burried under the ground complete all as specified and directed.
Taking out and removing waste materials/foreign materials from septic tank by manual labour or mechanical means of any size and burying the entire sludge under ground in a pit of suitable size and covering the pit with earth or earth mixed rubbish and removing surplus soil to a distance n.exc 500m including necessary earth work in pit complete all as directed by Engineer-in-Charge.
Cleaning of manhole of any depth, size and shape with spades or bucket and taking out sludge and disposed off aside by burying the entire sludge under ground in a pit of suitable size by putting earth on it. Again use water with bucket and put into manhole to clear the sludge and ensure the sludge is drain out complete all as specified and directed.
Making arrangement of scaffolding in the shafts height upto 10m, cutting holes around the bends, tees, junctions any description in the leakage/seepage and making good the cut portion with cement mortar 1:3 or PCC (1:2:4) (12.5mm graded stone aggregate) including two coats of acrylic emulsion antifungal paint with primer complete all as specified and as directed.
Making arrangement of scaffolding upto 10 meters in the shafts / spot / location of weed growth and removing the weed including root, making good with cement mortar 1:3 or PCC (1:2:4) (12.5mm graded stone aggregate) including two coats of acrylic emlsion antifungal paint with primer complete all as specified and as directed.
Removing vegetation/ small plants including uprooting completely lying on walls/roofs/chajjas/near service water tanks/along the soil pipes fixed on walls of buildings and making good to match with existing surface with PCC (1:2:4) type B1 (12.5mm graded stone aggregate) (or) in CM (1:3), covered area of each patch not exceeding 1 Sqm including necessary ladders/ scaffolding etc., complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth in hard / dense soil for foundation etc., or for shaft wells, cesspits, manholes, pierholes etc., not exc. 10 Sqm on plan and getting out complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 m but not exceeding 3m in depth in hard / dense soil for foundation etc., or for shaft wells, cesspits, manholes, pierholes etc., not exceeding 10 Sqm on plan and getting out complete all as specified and as directed.
M&L for returning filling in, hard/ dense soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
M&L for removing excavated material (any type of soil) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manholes including necessary formwork complete all as specified and as directed.
Demolition of Precast cement concrete block walling built in CM or Cement lime Mortar complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster on brick or stone masonry wall including racking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed.
M&L for 15mm thick plaster in CM (1:4) on fair face of brick walls or concrete surface including mixing of liquid water proofing complound @ 200ml per 50 Kg cement bag, finished the surface even and smooth using extra cement complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
SUPPLY ONLY liquid water proofing compound.
M&L for preparation of newly plastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for reinforced precast cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in landings, drain cover, cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary formwork, set in CM 1:4 complete all as specified and as directed. Note : Reinforcement shall be measured and paid for separately.
M&L for Mild steel TMT bars 10mm dia and over of grade Fe-500, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 6 to 8mm dia and over of grade Fe-500, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Demolition and breaking up 150mm dia (Salt glazed ware, AC or reinforced concrete) pipe jointed in cement mortar and disposed off the premises complete all as specified and as directed.
S&F 150mm bore PVC (SWR) pipes single socketed, in any length pipes with rubber ring joints, laid in trenches or or in floors using synthetic rubber adhesive cement solvent complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in bed with thickness of bed below the barrel of pipes as 100mm and width of bed as 450mm to sewage pipes of 150mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested complete etc. complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors using synthetic rubber adhesive cement solvent complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in bed with thickness of bed below the barrel of pipes as 100mm and width of bed as 410mm to sewage pipes of 110mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested complete etc. complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains for 150mm bore of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed
S&F PVC (SWR) 110mm dia, single socket, in any length with rubber bends, socket etc with reubber ring and jointed with approved adhesive and fixed to wall complete all as specified and directed
S&F in repair PVC (SWR) 110mm dia bend with access door of any radius and jointed with approved adhesive complete all as specified and directed
S&F in repair PVC (SWR) 110mm dia vent cowl with approved adhesive complete all as specified and directed
S&F PVC (SWR) 75mm dia, single socket, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed
S&F PVC (SWR) 75mm dia, single socket, in any length with rubber ring joints and jointed with approved adhesive laid in trenches or in floors complete all as specified and directed
S&F in repair PVC (SWR) bend 75mm dia with access door, any radius as required and jointed with approved adhesive complete all as specified and directed
S&F in repair 75mm outlet dia PVC (SWR) floor trap with grating including jointing with solvent cement to waste pipe complete all as directed
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed
M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for coloured glazed ceramic tiles as in vertical surfaces such as skirtings, wall, dados and risers to steps etc surface of size 350 x 250 x 7mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match designed including 10mm thick backing coat in CM (1:3) complete all as specified.
M&L for plain cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in levelling course, padding, sunken, coping portion rounded chamfered on edge complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
M&L anodized aluminium snap grid framework incl 4 mm thick non asbestos fibre cement building boards 600x600mm incl two coats OBD and preparation of surfaces over board inserted to framework with screws with hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone or steel/ aluminium frame concrete or brick surrounds, glazed complete all as specified
S&F plain sheet glass 4.0 mm thick ordinary quality and glazing with aluminum glazing clip in aluminum window shutter not exc 0.5 Sqm in each pane complete all as specified and directed.
Dismantling wood boarding, panels, beams or any description, fixed any position with nails complete all as directed.
S&F 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed complete all as specified and as directed.
S&F in repairs aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, fixed in repairs complete all as specified and as directed.
S&F in repairs double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and as directed.
S&F in repair PTMT cabinet mirror of size not less tha 500mm x 400mm x 100mm openable mirror shutter with suitable built-in -racks complete all as specified and directed. Make : Prayag (Cat Part No :556) or equivalent in Supreme / Nilkamal
S&F in repair curtain rods 25mm dia, mild steel, chromium plated with fixing brackets, stops, rollers etc.,complete all as specified and directed.
S&F in repairs door closer, aluminium (Die cast), hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, fixed in repairs with screws complete all as specified and as directed.
Taking up or down steel tubing 15mm bore and connections including cleaning and refixing or removal to store complete all as specified and as directed.
S&F 20mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting not exc 10 cm girth in PCC block masonry/RCC complete all as specified and directed.
M&L in repairs for vitreous China, wash down water closet pan (pedestal pattern), white including connection to drain (or out going pipe) and to flush pipe, antisypthonic (excluding flushing cistern and flush pipe) complete all as specified and as directed.
M&L in repairs for PVC water closet seat and cover, white, closed pattern with flat bottom and mild steel chromium plated or aluminium hinging device complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern) standard size with 'S' or 'P' trap and other connecting items approved brand including fixing with white cement complete all as specified. Make : Jaquar (Cat part No : LYS WHT 0314) or equivalent.
M&L for vitreous China water closet Orissa Pattern of size 580 x 440 mm white, ISI marked including provision of cement concrete bedding including connections to flushing cistern/pipe and making good disturbed portion to match existing surfaces complete all as specified and as directed.
S&F in repairs PVC white low level flushing cistern 10 litre capacity with all fittings syphonic action push type with inlet ball valve and float including flush pipe long 32mm dia, ball valve, handle, bracket etc complete all as specified and as directed.
S&F in repairs vitreous China counter wash hand basin oval shape, white of size 550mm x 400mm counter including brackets, 32mm dia waste coupling brass chromium plated, PVC waste pipe of suitable length, chain and plug, fixed complete all as specified and as directed.
S&F in repair vitreous China urinal half stall type (back or corner wall type), white complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in white cement fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
S&F 15mm dia brass CP Urinal Spreader complete all as specified and as directed.
S&F in repairs PVC connections 15mm bore dia 450mm long with 2 Nos PTMT nuts with washers complete all as specified and as directed.
S&F Iin repairs 32mm dia PVC flush pipe of polyethylene of low or high density for WHB, sink, urinal complete all as specified and as directed.
S&F in repairs 32mm waste coupling, brass, chromium plated for glazed ware sinks, basins, urinals etc with long screwed shanks and fly nuts, flange end bedded in red lead cement complete all as specified and as directed.
S&F in repairs 100mm CP waste coupling for sink complete all as specified and as directed.
S&F in repairs chromium plated brass shower roses with or without swivel joints square type 125mm size including shower arm complete all as specified and as directed.
S&F in repairs health faucet (ABS Body), MS, chromium plated with 15mm dia, 1.25 m long flexible tube, screwed for iron pipe or for brass ferrule 15mm dia or bore fixed in repairs complete all as specified and as directed.
S&F in repairs toilet paper holder complete all as specified and as directed. MAKE: JAQUAR Cat part No. ACN-1153N) or equivalent in PARRYWARE/ PRAYAG / GEM
S&F in repairs towel ring round Make Jaquar AQN -7721 or equivalent model in Parryware / Prayag / Gem
S&F in repair 20 mm dia brass stainless steel tubular towel rail D type 600mm long complete all as specified
S&F in repairs tubular towel rail, brass, chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs complete all as specified and directed. Make : Jaquar AQN 7711
S&F in repair chromium plated soap dish of size 120x80mm, fixed to plugs with chromium plated brass screws complete all as specified
S&F in repair 15mm dia cast copper alloy chromium plated long body bib tap fancy type with wall flange complete all as specified
S&F in repair bib tap, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed. Make : Jaquar Cat part No CON-107KN
S&F in repair 15 mm bore, cast copper alloy, chromium plated pillar tap long body swawn neck type fly nut capstan head screwed for 15mm bore dia of pipe complete all as specified and directed.
S&F in repair 15mm Stop valve angle cock cast copper alloy, fancy type, chromium plated with long shunk and cup high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified
S&F in repairs, CP angle cock 15mm dia. fancy type cast copper alloy with crutch or butterfly handle, screwed down of Make-Jaquar Cat. No. CON-053KN or equivalent model in Parryware / Prayag
S&F in repair 15mm concealed type angle cock cast copper alloy, fancy type, chromium plated with long shunk and cup high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified
Supply and fix in repairs CP WHB mixer cast copper alloy central hole for WHB and long shank fancy type 15 mm bore complete all as directed. Make - Jaquar Cat. No. CON-167KNB or equivalent model in Parryware / Prayag / Gem
Supply and fix in repairs CP brass hot and cold 15mm dia wall mixture 3-in-1 system with provision for both hand shower and overhead shower complete with 115mm long bend pipe, connecting leg & wall flange complete all as directed. (Make - Jaquar Cat. CON-281KN or equivalent model in Parryware/ Prayag / Gem
S&F in repairs 100mm size, 4 levers brass mortice lock, vertical type complete all as specified.
Sree Tirumala Enterprises
JD Construction
CARTWHEEL CONSTRUCTION
SKV Engineering
M/s Ramesh Lal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .