Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 CrAccepted-AOC | ₹10.2 Cr Quoted ₹10.3 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹10.6 CrRejected-Finance LIG FLATS 29 B RAMPURA DELHI NORTH WEST DELHI DELHI 110035 UDYAM DL 11 0082911 | NORTH WEST DELHI | DELHI | 110035 | ₹10.6 Cr | L2 | Rejected-Finance Higher rate to the contractor |
Tender Value
₹9 Cr
EMD Value
₹18 L
Closing Date
9 Jun 2022, 5:00 pmClosed
Executive Engineer (Const.)
CCS HAU, Hisar
Establishment of Nutri-cereal Research Station, Gokulpura (Bhiwani) (i.e. construction of main building, stores, boundary wall, open parking area, approach road, cycle stand and main gate etc.)
2022_HRY_223182_1
3306-C
Open Tender
Civil Works
450 days
CCS HAU
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,000
₹18 L
Yes
22 Jul 2022
24 May 2022
10 Jun 2022
24 May 2022
9 Jun 2022
24 May 2022
Amount
Civil work 1 to 141:- Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil (HSR 4.4.1)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. All kinds of soil (HSR 4.12.1)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (HSR 4.14.1)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. (HSR 4.32)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) (HSR 6.1.6)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor four level, excluding the cost of centering, shuttering and finishing: 1 :2:4 (1 Cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 20 mm nominal size) (HSR 6.2.2)
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) 40mm thick (HSR 6.8.2)
25 mm thick (HSR 6.8.3)
Providing & applying a coat of residual petroleum bitumen of grade of VG-1 O of approved quality using 1. 7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. (HSR 6.10)
12 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded: Vertical (HSR 6.11.1)
Horizontal (HSR 6.11.2)
20 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded Vertical (HSR 6.12.1)
Horizontal (HSR 6.12.2)
Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR 6.13)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size) (HSR 6.15.1)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1 ½ coarse sand(zone-111) : 3 graded stone aggregate 20mm nominal size). (HSR 6.21)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). All works up to plinth level (HSR 6.25.1)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (HSR 6.30.1)
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (HSR 6.30.2)
Suspended floors, roofs, landings, balconies (HSR 6.30.3)
Shelves (Cast in situ) (HSR 6.30.4)
Lintels, beams, plinth beams, girders, bressumers and cantilevers (HSR 6.30.5)
Columns, Pillars, Piers, Abutments, Posts and Struts (HSR 6.30.6)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diaMeters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D kg or more. (HSR 6.33.6)
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1 :3 (1 Cement : 3 coarse sand), including the cost of required centering, shutteringcomplete. 1:1½ :3 (1 Cement: 1½ coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.39.1)
Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.21.1)
Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.21.2)
Brick work with common burnt clay non-modular bricks of class designation 10 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.22.1)
Brick work with common burnt clay non-modular bricks of class designation 10 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in foundations and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.27.2)
Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. Cement mortar 1 :4 ( 1 cement :4 coarse sand) (HSR 7 .28.2)
Extra for providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of half brick masonry. (HSR 7.30)
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor IV level in cement mortar 1 :4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of masonry work. (HSR 7.50)
Providing and laying autoclaved aerated cement blocks masonry with 150mrn/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in- Charge. (The payment of RCC band and reinforcement shall be made for separately). (HSR 7.51)
Wall lining butch work up to 10m height with Dholpur stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width, including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75 mm and by providing layer of 75 mm thick strips i/c 12 mm thick bed of cement mortar 1 :3 (1 Cement : 3 coarse sand) i/c ruled pointing in cement mortar 1 :2 (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in-charge. (HSR 8.12)
Providing & fixing factory manufactured jali of reinforced cement concrete consisting of cement , coarse sand and 10mm & down gauge bajri in ratio of 1: 1 :2 with Bmm dia tor steel. Outer frame of the jail will be 50mm wide & 25mm thick & inner frame of jali will be 25mm wide and 25mm thick with smooth finish as per design approved by the Engineer-in-Charge including fixing in position up to any height with cement sand mortar 1 :4 complete in all respect. (HSR 8.17)
Painting top of roofs with bitumen of approved quality @ 17kg per 1 O sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete With residual type petroleum bitumen of grade VG -1 O (HSR 9.10.1)
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (HSR 9.11.1)
Providing gola 75x75 mm in cement concrete 1: 2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase (HSR 9.17.1)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant board (HSR 9.46.3)
Providing and Fixing 15 mm thick densifled tegular edged eco friendly light weight calcium silicate false celling tiles of approved texlure of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densifled edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixlures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ·r, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (HSR 9.48) Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diaMeter (HSR 9.57.2)
150 mm diaMeter (HSR 9.57.3)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single push fit Coupler 110 mm (HSR 9.58.2.2)
150 mm (HSR 9.58.2.3)
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
Providing and laying of screed of 50 mm thick cement concrete 1 :8:16 to be laid below the topping. (HSR 10.4)
Providing and laying of conglomerate floor 40mm thick cement concrete topping 1 :2:4 (HSR 10.8)
Providing and laying of 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1 :2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. (HSR 10.11)
Providing and laying cement plaster skirting up to 30 cm height, with cement mortar 1: 3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick (HSR 10.13.1)
Providing and laying cement concrete pavement with 1: 2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (HSR 10.16)
Brick on end in soil/edging in required pattern with bricks of class designation (HSR 10.36)
Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete. (HSR 10.56)
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (HSR 10.60)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.62)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)
Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (HSR 10.70.2)
Providing and laying 60mm thick factory made cement concrete inter1ocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006) and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (HSR 10.76)
Cement Concrete 1 :8:16 Flooring Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)
12 mm cement plaster of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.5.3)
1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.6.1)
1 :6 (1 cement: 6 fine sand) (HSR 11.6.2)
Pointing on tile brick work with cement mortar 1 :3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing (HSR 11.26.1 )
Pointing on stone slab ceiling with cement mortar 1 :2 (1 cement : 2 fine sand): (HSR 11.29.1) Flush/ Ruled pointing
Rough cast plaster up to 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 1 O mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1 :4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement (HSR 11.32.1)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)
Distempering with 1st quality acrylic distemper (ready mixed) having voe content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work (HSR 11.65.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (HSR 11.68.3)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied@ 3.84 kg/10 sqm) (HSR 11.93.1)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (HSR 11.95.1)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws. Kiln seasoned and chemically treated Hollock wood 35 mm thick (HSR 12.10.2.1)
Providing & Fixing decorative high pressure laminated sheet of plain/ wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick (HSR 12.12.2)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright Kiln seasoned and chemically treated Hollock wood (HSR 12.19.2.1.2)
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws (HSR 12.37.1)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. (HSR 12.37.3)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (HSR 12.50.1)
Providing and fixing aluminium e xtruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS: 3564, embossed on the body, door weight up to 3 6 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (HSR 12.89)
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm (HSR 12.98.2 )
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 100 mm (HSR 12.102.2)
75 mm (HSR 12.102.3)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) (HSR 12.157.1.2)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass /stainless steel screws, all complete as per architectural drawings and thedirections of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Powder coated aluminium (minimum thickness of powder coating 50 micron(HSR 12.157.2.2 )
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides (HSR 12.158.2 )
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (HSR 12.159.2 )
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness (HSR 12.160.1)
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminium (HSR 12.167.2)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.1.1)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.3.1 )
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes (HSR 13.10.1)
Providing & fixing glazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of Gasket I beading shall be paid as per respective item) Float glass panes of 5.5mm thickness (HSR 13.24.1)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (HSR 13.29.2)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1 .25 mm M.S. laths with 1.25 mm thick top cover (HSR 13.37.1)
Compacting Original Ground Compaction of Earthwork Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications (in case of link roads earthwork to be done by villagers) (HSR 17.5.3)
Granular Sub-Base with Close Graded Material· (Table:- 400-1) Plant mix method Construction of granular sub-base by providing Material as per Grading Ill (Table 400-1 of MORT&H 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications. Grading II material (HSR 17.14.2)
Grading Ill material (HSR 17.14.3)
Water Bound Macadam Gr I Water Bound Macadam Grading I with screening Type 'A' Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-1 0 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (HSR 17.22.2)
Water Bound Macadam Grading -II Water Bound Macadam - II with Screening Type 'A' / Type B Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-1 0 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (HSR 17.23.2)
Tack Coat Providing and applying tack coat with penetration grade bitumen VG - 10 using bitumen pressure distributor at the rate of 0.30 kg per sqm on the prepared bituminous/ granular surface cleaned with mechanical broom as per technical clause 503 of MORT&H specifications (HSR 17.26.2)
Surface Dressing Providing and laying surface dressing as wearing course in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG - 10 laid on prepared surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 509 of MORT&H specifications. 19 mm nominal chipping size, with Bituminous emulsion Note:- 1.Where the proposed aggregate fails to pass the stripping test, an approved adhesion agent may be added to tt,e binder as per clause 510.2.4. Altematively, chips may be pre-coated as per clause 510.2.5. 2.lnput for the second coat, where required, will be tt,e same as per tt,e 1st coat mentioned above (HSR 17.32.2)
Open - Graded Premix Surfacing 20 mm U,ickness Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of crushed stone aggregates of specified grading premixed in a continuous type of hot mix plant of appropriate capacity not less not less than 75 tonne per hour, with bituminous binder VG - 10 @ 1.46 kg per sqm, laid with Paver Finisher Mechanical and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 510 of MORT&H specifications (HSR 17.33.1)
Type B with VG -10 bituminous binder Providing and laying of premix sand seal coat premixed in continuous type HMP of appropriate capacity not less than 75 tonnes/ hours using specified fine aggregates and penetration grade bitumen @0.68 kg/sqm laid to specified levels, grade and cross fall complete as per technical clause 511 of MORT&H specifications. (HSR 17.36.3)
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 1 O cm. (c) third layer of 1.5 mm thickness consisting of sluny of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. (HSR 28.16)
Providing and laying cinder concrete in cement 1 :15 (1 cement and 15 cinder) on terraced roofs & (up to three Storeys), laid to slope, including consolidating the same. (HSR 28.27)
Earth filling under floors with dune sand (tiba sand), brought from outside (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete (NS)
Earth filling under road/parking with dune sand (Tibba sand) brought from outside (any lead) in 25 cm. layer including laying, dressing, watering, rolling with road roller to specifications/ consolidating, excavation, carriage, compensation, loading and unloading, complete in all respects. (NS)
Providing and fixing 15 mm to 18 mm thick Sardar Ali granite stone (polished) in flooring including matching grains laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing 15 mm to 18 mm thick Sardar Ali granite stone (polished) in skirting including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing marble strips of size 14 mm to 17 mm thick and 35 mm wide in cement concrete/ terrazzo flooring fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
Providing and fixing marble strips of size 14 mm to 17 mm thick and 40 mm wide in cement concrete/ terrazzo flooring fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
Providing and fixing marble strips of size 14mm to 17 mm and 125 mm wide in cement concrete pavement and road, complete in all respects as per drawing and design or as directed by Engineer-in-Charge.. (NS)
Providing and fixing 15 mm to 18 mm thick Z-black granite stone (polished) on worktop including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing stainless steel stair case railing 304 grade consisting of stainless steel tube as hand rail, internal members (Horizontal/vertical) of required size including cutting, welding, grinding, buffering etc., complete in all respect as per architectural drawing and design. (NS)
Providing and fixing 12mm thick toughened glass (AIS, Modi Guard or Saint Gobion make) as fixed panels, all height, in powder coated aluminium sections & beadings for glazing, fixed in position, complete in all respects as per architectural drawing and design, but excluding element of aluminum sections and beadings which shall paid separately. (NS)
Providing and fixing Glass Accessories i.e. handle of size 600 mm x 30 mm of DORMA make (Model XL-C-3004 ) including cost of stainless steel screws etc. complete in all respect as directed by Engineer-In-charge. (NS)
Providing and fixing Glass Accessories i.e. glass door package with lock (floor machine) of DORMA make (Model XL-C-4001) including cost of stainless steel screws etc. complete in all respect as directed by Engineer-In-charge. (NS)
Providing and fixing 25 mm dia stainless steel curtain rods weighing 0.560 kg/meter with brackets & side covers (balls) of vista make, clamps, plastic gutties/rawl plugs etc., complete in all respects. (NS).
Providing, diluting and injecting chemical emulsion for pre-constructional anti-termite treatment and creating a continuous chemical barrier under and all around the column pits, wall trenches, basement excavation, top surface of plinth filling junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits etc., complete as per PWD specifications (plinth area of the building at ground floor only shall be measured of payment) (NS) (The material i.e. Chlorpyriphos Emulsifiable concentrate 20% with 1% conentration).
Providing and fixing C.I. grating over 100 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Providing and fixing C.I. grating over 150 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Providing and fixing factory manufactured cement concrete 1:2:4 kerb finished smooth and of size 1’-0” x 1’-0” x 0’-6” with rounded edge, fixed at ground level along with road/cement concrete payments, complete in all respect but excluding cost of cement pointing. (NS)
Providing and fixing factory manufactured cement concrete 1:2:4 channel finished smooth and of size 1’-0” x 1’-0” x 0’-3” of required shape and design fixed at ground level along with road, complete in all respect as directed by the Engineer-in-Charge but excluding cost of cement pointing. (NS)
Providing and fixing 19 mm thick BWR grade-II block board (ISI mark) of approved make shutters for cabinet including cost of iron hinges, screws etc. complete fixed in position but excluding cost of primer and paint. (NS)
Providing and fixing 4mm thick aluminium composite panels (ACP) of ALSTONE or ALUDECORE make of approved colour fixed on aluminium tube frame of size 50mm x 25 mm x 2.0mm @ 2’-0” c/c (horizontal/vertical as required), including sealent, tape, nails, screws etc. complete in all respects as per drawing and design. (NS)
Providing and fixing G.I. barbed wire fencing (made of wires of TATA make), weighing 13.60 kg to 15.50 kg per 100 metres (Horizontal/ diagonal) and fixed with G.I. wire of 12 gauge or by providing cut including drilling holes in the posts, complete in all respects as directed by Engineer-in-Charge (including the cost of G.I. wire used for binding which shall not be measured for payment but excluding the cost of posts, struts, earth work and concrete which are payable separately) (NS)
Providing and fixing concertina spiral G.I. wire fencing of 2’-0”/1'-6" dia on Y-shape angle iron posts and barbed wire fencing (excluding cost of angle iron posts & barbed wire fencing) weighing 150 kg to 160 kg per 100 meter, ( of make as approved by Engineering In charge and confirming to IS specifications) fixed with plain GI wire of 16 gauge, complete in all respect as directed by Engineer-in-Charge (plain GI wire used for binding shall be not be measured for payment). (NS)
Providing and fixing 6 mm thick High pressure Laminated (HPL) sheets, at all height of Green, century Alstone or Sunderk of approved colour fixed on aluminium tube frame of size 25 mm x 38.10 mm x 2.00 mm @ of 2'-0'' C/C on wall cladding including sealent, tape, rawl plugs, nails, screws etc., complete in all respect as directed by Engineer-in-Charge. (NS)
Providing and fixing University round Logo of 30'' dia made of 3 mm thick acrylic sheet with LED light, complete in all respect as directed by Engineer-in-Charge. (NS)
Providing and fixing acrylic words of 15'' & 18'' height with LED light including cost of electric wires & connectors, tape, screws, gutties, nuts, bolts etc, complete in all respect as directed by Engineer-in-Charge. (NS)
Providing and fixing double leaf stainless steel gates made of 304 Grade stainless steel tobes of size 40 mm x 40 mm & 25 mm x 25 mm or any other size as frame, both sides finished with 1.5 mm thick/ any other thick stainless steel sheet including bottom pivots, hold fasts, 18'' long stainles steel tube handle, 1'-2'' long stainless steel sliding bolts (16 mm dia), etc., fixed in position, complete in all respect as directed by Engineer-in-Charge. (NS)
Providing and fixing PVC wall paneling consisting of 7mm thick cactus make hollow PVC section, PVC U section beading of size 25mmx8mmx12mm and PVC angle nosing of size 25mmx25mmx1.5mm including cost of PVC gutties, screws, jointed with polyfix (instant glue), complete in all respect as per drawing or as directed by Engineer-in-Charge. (NS)
Chamfering of granite stone fixed on worktop to required shape, complete in all respects as directed by Engineer-in-charge. (NS)
Public Health work 142 to 246:- Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (HSR 4.14.1)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc, not exceeding 80 metre (HSR 4.16.1.1)
Pipes, cables etc. exceeding 80 mm metre (HSR 4.16.1.2)
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). (HSR 4.17)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) : 6 graded stone aggregate 20 mm nominal size) (HSR 6.1.4)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.14.2)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies (HSR 6.30.3)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diaMeters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D kg or more. (HSR 6.33.6)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)
Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.20.1)
Brick work with common burnt clay non-modular bricks of class designation 10 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in foundations and plinth in: Cement mortar 1:3 (1 cement: 3 coarse sand) (HSR 7.27.1)
Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado/worktop/risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51)
12 mm cement plaster of mix : 1 :4 (1 cement: 4 coarse sand) (HSR 11.8.1)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (HSR 13.27)
Providing and laying of conglomerate floor 50mm thick cement concrete topping 1 :2:4 (HSR 10.7)
Cement Concrete 1 :8:16 Flooring Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)
12 mm cement plaster of mix : 1 :2 (1 cement: 2 fine sand) (HSR 11.5.1)
1 :3 (1 cement: 3 fine sand) (HSR 11.5.2)
Cement rendering on plaster 1 mm thick (HSR 11.52)
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 25 mm internal diameter (HSR 20.23.3)
32 mm internal diameter (HSR 20.23.4)
50 mm internal diameter (HSR 20.23.6)
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required 11.43 cm thick wall (HSR 20.26.1)
22.86 cm thick wall (HSR 20.26.2)
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside buildings, including cartage from divisional stores or nearest railway station to site of works 25 mm internal diametre (HSR 20.31.3)
32 mm internal diametre (HSR 20.31.4)
50 mm internal diametre (HSR 20.31.6)
Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 20.36)
Providing GI pipes class B marked with IS: 1239 in 3.05 m length, their threading and welding with flanges (Heavy Duty) on both sides, jointing with nuts and bolts ( 'W make), rubber gaskets, lowering into Tube wells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. (30 x 4) 80 mm i/d (HSR 20.54.3)
Providing and fixing Ductile Iron Double seal manhole covers and frames of 610 mm x 610 mm with locking arrangement on clear water tanks including cost of setting in Cement concrete 1 :2:4 to correct alignment and levels including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. (HSR 20.61)
Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of O to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in fal respect. (1 x 4) Make:- L&T, SIEMENS, BCH, SCHNEIDER. 30 HP Motor (HSR 20.114.5)
Providing & fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS: 1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1 :2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge (HSR 21.28)
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benchingb 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) (HSR 21.84.3)
Extra for every 0.30 metre depth of Inspection chamber 600 mm x 900 mm inside (HSR 21.85.3)
Providing salt glazed stone ware pipes grade 'A' in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. (HSR 21.94.2) 150mm i/d
200mm i/d (HSR 21.94.3)
Providing and fixing white vitreous chinaware laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm (HSR 22.6.2)
Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). Two way (HSR 22.8.2)
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 610x460 mm bowl depth 200 mm (HSR 22.10.2.2)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15)
Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint. (HSR 22.16)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (HSR 22.22.1)
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required. Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern (HSR 22.26.3)
Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (HSR 22.33)
Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (HSR 22.34)
Providing and fixing 8 mm dia C.P.S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)
Providing and fixing partitions for different type of urinals. Large size 835mm x 355 mm White (HSR 22.50.1.2.1)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (HSR 22.86.2)
25 mm nominal outer dia Pipes (HSR 22.86.3)
32 mm nominal outer dia Pipes (HSR 22.86.4)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal outer dia Pipes (HSR 22.87.6)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (HSR 22.103.3)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore (HSR 22.106.1)
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181)
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. C.P Brass Two Way (HSR 22.212.1.2)
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 110 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.2)
90 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.3)
EARTHING AND LIGHTENING ARRESTOR Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (1 x 4) (HSR 24.1.1)
Extra for using salt and char coal/coke for pipe earth electrode as required. (1 x 4) (HSR 24.1.2)
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (4 x 4) (HSR 24.1.11)
Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. (213.36 x 4) Submersible Copper Cable 3 Core 16 sqmm (HSR 24.5.1.6)
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yieldwithout sand content (beyond permissible limit), with requiredcapacity air compressor, running the compressor for requiredtime till well is fully developed, measuring yield of well by "V''notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (8 x 4) (HSR 33.19)
Providing and fixing in position v.chinawarwe W.H.B (Table top) (Aviator) Italian, white of Hindware make of size 59.50 x 42 x 15.5 cm, cat No. 91207, Star white (NS)
Supply and fixing of PVC floor traps (Heavy duty) of 90 mm o/dia outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)
Providing and fixing CP brass Piller tap of Jaquar make cat No. KUP-35021, white 190 mm (NS)
Supply of CPVC Union Couplings with brass internals of Prince/Supreme/Skipper make . (NS) (a)25 mm dia
(b) 32 mm dia
(c) 50 mm dia
Supply of CPVC Control valves with brass internal fittings, complete in all respect. (NS) (i) For 25 mm nominal outer dia Pipes
(ii) For 32 mm nominal outer dia Pipes
(iii) For 50 mm nominal outer dia Pipes
Supply of CPVC waste pipes embeded in wall, complete in all respect. (a) 40 mm i/dia size Make:-Skipper/Supreme/Prince (NS)
Providing and fixing looking mirror 5.0 mm thikc of size 3'-0" x 2'-6" mounted on asbestos sheet ground fixed in position by means of 4 Nos. C.P. brass screws and washers on rubber washers and rawl plugs embeded in wall or CP brass clamps with CP brass screws etc. complete in all respect. Make:- Saint Gobin/MODI/ATUL (NS)
Providing and fixing CP Grating 5" dia size of best quality, complete in all respect. (NS)
Providing and fixing PVC specials of Prince/Supreme/Skipper make of following sizes. (NS) (a) Elbows 3" i/dia size
(b) Elbow 4" i/dia size
(c) Door Elbow/bend 3" i/dia size
(d) Door Elbow/bend 4" i/dia size
(e) Door junction 3" i/dia size
(f) Door junction 4" i/dia size
(g) Cowl 3" i/dia size
(h) Cowl 4" i/dia size
(i) H.R. bend 4" i/dia size
Providing and installation of self contained drinking water cooler of fully stainless steel body (FSS) with refrigerant R-134 A, cooling capacity 150 liters per hour and storage capacity 150 liter suitable on operating power supply 230 ± 10 %, 50-Hz single face AC complete in all respect. Make = Usha/Voltas/Blue star as approved by the Engineer Incharge. (NS)
Providing and fixing in position R.O.water purifier (to be fixed with water cooler) having at least 50 ltrs./hour purification capacity and fully automatic operation with auto start and auto off system and as per complete specification of the manufacturer complete in all respect. (NS) Make:- KENT-ELITE Model or equivalant from Aqua guard.
Providing and laying brick ballast and brick bats of required size in the soak pit complete in all respect to the directions of the Engineeer-In-Charge. (NS)
Drilling of 250 mm dia bore with suitable boring system including cost of all cousumable stores and transportations and other accessories etc. complete in all respect. (137 x 4) (NS)
Supply, lowering & fixing of 225 mm o/dia PVC pipe 6kg/cm2 pressure ISI marked of Supreme/Skipper/Prince make, complete in all respect. (75 x 4) (NS)
Supply, lowering & fixing of Filter pipe of 225 mm o/dia, 6kg/cm2 pressure ISI marked (with filter Jali etc.) of Supreme/Skipper/Prince make, complete in all respect. (62 x 4) (NS)
Supply, lowering & fixing of submersible motor with pump set of 30 HP capacity 3 stages complete in all respect of KSB/LUBI/Kirloskar Make (1 x 4) (NS)
Providing and fixing PVC Socket 225 mm dia size of Supreme/Skipper/Prince Make. (22 x 4) (NS)
Providing and fixing Copper rivetts of best quality, complete in all respect. (160 x 4) (NS)
Providing and fixing M.S. base plate 250 mm dia size of best quality, complete in all respect. (1 x 4) (NS)
Supply and fixing of G.I. bend with welding flanged complete with nuts & bolts etc., complete in all respect. (1 x 4) (NS) 3" i/dia size
Supply of solvent (for jointing of PVC pipes and specials) of best quality, complete in all respect. (4 x 4) (NS)
Providing and fixing PVC end cap for 225 mm dia pipe 6 kg/cm² pressure of Supreme/Skipper/Prince make. (NS)
Electrical work 247 to 385:- Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.1.2)
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B (HSR 23.4.4.2)
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2)
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B (HSR 23.4.3.2)
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1)
1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.5.6.2)
1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.3)
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed inwalVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2)
PVC pipe of 40 mm dia. (HSR 23.7.6.4)
Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm each 106 long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4 )
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data. (HSR 23.8.10.1)
4 Modules (HSR 23.8.10.3)
6 Modules (HSR 23.8.10.4)
12 Modules (HSR 23.8.10.6)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7)
Telephone Socket outlet modular type (HSR 23.8.11.8)
Blanking plate (HSR 23.8.11.10)
RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11)
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9)
4 pole MCCB 300 to 400 amp , 50 KA (HSR 23.22.1.12)
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing) (HSR 23.22.4.1)
TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) (HSR 23.22.4.5)
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) (HSR 23.22.4.7)
TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) (HSR 23.22.4.8)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1)
6 amp. to 32 amp MCB's FOUR POLE (HSR 23.22.5.7)
40 amp to 63 amp. MCB's FOUR POLE (HSR 23.22.5.8)
Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia (HSR 23.23.2.1)
Supply and erection of blanking sheet in existing distribution board. (HSR 23.22.7)
SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 300 amp 415 volts (HSR 23.22.8.4)
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1)
Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required. (HSR 23.23.9)
Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current. The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1: 2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer- in-charge of the work:- M.S. pedestal of size 1500 mm wide , 1800 mm high ,450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1650 mm x 600 mm x 200 mm above ground level , having a base of size 1 BOO mm x 750 mm x 250 mm below ground level. (HSR 23.27.6)
RCC FOUNDATIONS FOR DG SET Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1. Bx1 .Om) 125 KVA OG Set (HSR 24.7.4)
EARTHING AND LIGHTENING ARRESTOR Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1)
Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2)
Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including each 3772 accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3)
Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode. (HSR 24.1.5)
Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. (HSR 24.1 4)
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7)
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8)
Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.9 )
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.10)
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. (HSR 24.1.13)
Laying of underground cable 0. 75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 16 Sq mm to 35 sqmm 2 to 4 Core (HSR 24.2.2.2)
50 Sq mm to 150 sqmm 2 to 4 Core (HSR 24.2.2.3)
300 sqmm to 400 sqmm 3 to 3½ Core (HSR 24.2.2.5)
Laying of underground cable in pipe /existing open/closed trench etc as 16 Sq mm to 35s qmm 2 to 4 Core (HSR 24.2.3.2)
50 Sq mm to 150s qmm 2 to 4 Core (HSR 24.2.4.3)
300s qmm to 400 sqmm 3 to 3½ Core (HSR 24.2.4.5)
Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16s qmm Cable 2 to 4 Core (HSR 24.2.7.2)
25 sqmm to 50s qmm Cable 2 to 4 Core (HSR 24.2.7.3)
70s qmm to 95s qmm Cable 3 to 3½ Core (HSR 24.2.7.4)
300s qmm to 400 sqmm Cable 3 to 3½ Core (HSR 24.2.7.7)
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm (HSR 24.2.8.4)
25sqmm (HSR 24.2.8.5)
50sqmm (HSR 24.2.8.7)
95 sqmm (HSR 24.2.8.9)
300sqmm (HSR 24.2.8.14)
Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 1 O A SP MCB, end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1 :5: 1 O of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge. 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm (HSR 24.4.8.5)
S/E of underground cable XLPE CABLE aluminium conductor armoured .(NS) 16 sqmm 4 core cable (armoured)
25 sqmm 4 core cable (armoured) (NS)
50 sqmm 4 core cable (armoured) (NS)
95 sqmm 3.5 core cable (armoured) (NS)
300 sqmm 3.5 core cable (armoured) (NS)
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe (NS) (i) Size 1.5 sqmm(3/0.81mm)
(ii) Size 2.5 sqmm(3/1.05mm) (NS)
(iii) Size 4 sqmm(7/0.85mm) (NS)
v) Cable size 6 sqmm(7/1.05mm) (NS)
(v) Cable size 10 sqmm(7/1.35mm) (NS)
Designing, Supply & erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 v. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT's) h) Metering set 60/5A/11 OV (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size I) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, De control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge 125 KVA (HSR 20.89.7)
Supply, installation testing and commissioning of wall/free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware 3mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet 3mm thick for separately cable alley to BBC from switch chamber extended solid copper bars upto cable alleys shall provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection (Only outer area on all sides shall be measured) (NS)
Supplying and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. (NS)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator . {NS} i) 1200mm sweep. Make: Usha, Orient, Crompton.
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator {NS} i) 1400mm sweep. Make: Usha, Orient, Crompton.
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor >0.95, CRI >80, Average life >50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial) Make: Philips, Havells, Wipro, Bajaj. (NS)
Supply of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangements of fan with shutter complete in all respects Size 300mm(12”) sweep Make: Orient, Usha, orient, Havells. (NS)
S/E of recessed type 42 Watt full window glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600K to 6500K), Power factor >0.95, CRI (Ra) >80, LED Lamp efficiency ≥ 140 lm/w, Average life > 50000 hours, complete with all accessories as required with connections (Industrial) Make: Havells /Bajaj/Wipro/Philips(NS)
S/E of LED Street Light of system voltage < 70/72watt IP66 Multiple LED with Lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen < 72watt LED should be 8400 or above in cool day light 5700K Lumen efficency > 120lm/w. Power Factor >.95 with connections on existing street light / PCC Poles i/c 3 year defect liability period and free replacement in case of non functioning of the light fixture Make Philiphs , Havell's , Wipro,Bajaj , HPL (NS)
S/E of Single Arm bracket 1.5mtr Long 40mm dia G.I bracket with suitable seelve as per pole top dia galvanised with all petty material required to complete the job for satisfaction of Enginneer in charge. (NS)
S/E of Double Arm bracket 1.5mtr Long 40mm dia G.I bracket with suitable seelve as per pole top dia galvanised with all petty material required to complete the job for satisfaction of Enginneer in charge. (NS)
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-32/R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:-(i) Cooling coil row -3 Nos.(ii) Air flow (CMH) - 800 to 1400 cum/ hr.(iii) Sound level (H/M/L)- 41/38/34/25(silent mode)(iv) Louvers swing- 3D + 3D Auto etc. complete in all respectMAKE :- O General/Mitsubishi (Heavy Industries)/Hitachi (five star rating) Model as approved by the Engineer-in-Charge. (NS)
S/I/T/C of 2.0 Ron Cassette AC indor unit 4 way cassette power supply in outdoor unit single phase 50Hz 220-240V ,Cooling capacity rated kw 5.5 rated power consumption rated kw 1.5 ISEER rated 5.05 air flow m3/s indoor unit 0.29/0.24/0.22,outdoor unit 0.64,CFM indoor unit 700/615/520 ,sound pressure (db) 38/32/30 ,pipe length(m) outdoor unit 32 m charge less 15,minimum pipe length 2,maximum pipe length 25 ,maximum pipe height 10,operating range (c) 15-46 GAS-R-410/R-32. Make:-Mitsubishi (Heavy Industries)/Hitachi (five star rating) Model as approved by the Engineer-in-Charge. (NS)
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge of Voltstar / microtek make ISI marked complete in all respect. (N.S.)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
S/I/T/C of CPVC/UPVC Pipe for Drainage System of Air Conditioners 25mm dia including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Finolex/Ravindra/Supreme
Supply of PVC pipe 6 kg/cm² pressure of ISI marked of Prince / Supreme/Skipper make (as approved by the Engineer-in-Charge). (NS) a) 110 mm o/dia size
b) 65 mm o/dia size
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Schneider/Crabtree/Athena
Supply, erection of 0.51 mm jelly filled armored telephone cable laid one mtr. below ground level including the cost of digging, bricks, rawl & laying charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS) (i) 20 Pair Make:- DELTON/ FINOLEX/ HAVELLES
Supply, erection of 0.51 mm jelly filled armored telephone cable loose in existing pipe/tranches including testing & commissing charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS) (i) 20 Pair Make:- DELTON/ FINOLEX/ HAVELLES
Supply, erection, laying and testing of D.P. including the cost of krones, base plate, 40mm dia G.I. pipe for incoming and outgoing cable and main box having locking arrangement. (NS) (i) 10 pair DP Make:- DELTON/ FINOLEX/ KONE
20 Pair DP,Make:- DELTON/ FINOLEX/ KONE
CCTV:-Supply Installation testing & commissioning of 4MP IP Network Dome Camera with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Image Sensor : 1/3” 4 Megapixel Progressive scan CMOS sensor or better ,Effective Pixels : 2688(H)x1520(V)) or better , Electronic Shutter : Auto/Manual, 1/3(4)~1/100000s, Scanning System : Progressive , Mini. Illumination : 0.08Lux/F2.0(Color); 0Lux (IR on), S/N Ratio : More than 50dB , Min. IR LEDs Length ≥50m, Day/Night : Auto(ICR) / Color / B/W,Back Light Compensation : BLC / HLC / WDR(120DB) ,White Balance : Auto/Natural/Street Lamp/Outdoor/Manual ,Motion Detection : Off/On (4Zone, rectangle),Focal Length : 2.8mm,Angle of View : H: 104° ,V: 57° ,Video Compression : H.265+/ H.265 ,Resolution : 4MP (2688x1520)/3MP(2304x1296)/ 2MP(1920× 1080)/720P(1280× 720),Frame Rate (3 Stream) : Main stream (4MP (1 ~ 25/30fps)) & Sub stream : D1(1 ~ 25/30fps)& Third Stream : 720P (1 ~ 25/10fps),Digital Zoom : 16x,Bit Rate : H.265: 14 ~ 9984Kbps,Network Ethernet : RJ-45 (10/100Base-T) ,Protocol : HTTP; HTTPs; TCP; ARP; RTSP; RTP; UDP; SMTP; FTP; DHCP; DNS; DDNS; PPPOE; IPv4/v6; QoS; UPnP;NTP; Bonjour; 802.1x; Multicast; ICMP; IGMP; SNMP,SD Card : Min 128GB SD card support,Power Supply : DC12V, PoE (802.3af),Working Environment : -30°C~+60°C / Less than 95%RH (no condensation),Ingress Protection : IP67 ,Audio Interface : Built-in-Mic,Intelligence (IVS) : Tripwire, Intrusion, Object Abandoned/Missing ,Advanced Intelligent Functions : Face Detection MAKE : DAHUA/HONEYWELL/HYUNDAI (NS)
Supply Installation testing & commissioning of 6TB surveillance hard disk with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : WD-PURPLE/SEGATE
Supplying, Installation,Testing & Commissioning of 43 " LED /LFDFull HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 4000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-S with Mounting Brackets/stand as per Technical Specification complete in all respect. (NS) MAKE :- Sony / Samsung / LG
Supply Installation testing & commissioning of 24 Port POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Switch should offer Wire-Speed and Non-Blocking Switching with 24 10/100/1000 RJ45 PoE/PoE+ Ethernet ports and additional 4 SFP+ (1G/10G ) fiber based ports, Minimum 2 port Populated with 10G MMF,Access Switches should support non-blocking switching fabric capacity of minimum 88 Gbps and minimum line-rate forwarding capacity of 57 Mpps, Access switch should support minimum 16K MAC addresses and minimum 4K active VLANs, Access Switch should have stacking capability with minimum stacking bandwidth of 40Gbps and should support a minimum of 8 units in a stack. Minimum one meter Stacking cables should be included in supplied material, Access switch should support up to 8 hardware queues per port, Access Switch should support full Layer 2 features like STP, RSTP, LACP, ACL, QoS, IGMP v1/v2, Access Switch should support basic L3 features like IPv4 & IPv6 static routing, Layer 3/4 ACLs, ECMP, virtual interfaces and routed interfaces from day 1, Access Switch should be upgradable to support advance Layer 3 features like, RIPv1/v2, OSPF v2, OSPFv3, and HSRP/VRRP in future with an additional software license upgrade,Access Switch should support minimum 1K IPv4 routes, The Access Switch should support IPv6 management features like IPv6 ping, IPv6 trace route, IPv6 Telnet, IPv6 TACACS, IPv6 and IPv6 RADIUS, All Switches and Transceivers should be of same OEM make,Access switch should support minimum 4K ACL rules ACL per Switch, Access switch should support SNMP v1/v2/v3, SSH, NTP and web management, Access switch should have 1G of RAM and 2G of Flash Memory.(NS) MAKE : RUKUS/CISCO/HP
Supply Installation testing & commissioning of 48 Port Non POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support having following technical specifications :Switch architecture should be Fixed Form factor/ stackable based.Switch should have wire-speed, non-blocking and fanless designe Architecture.Switch should have minimum of 48 x 10/100/1000 Mbps RJ45 ports and additional 4 SFP+ (1G/10G ) fiber based ports, Minimum 2 port Populated with 10G MMF.Switch should have minimum of 136 Gbps or more data switching capacity and 95 Mpps or more forwarding throughput.Access Switch should have stacking capability with minimum stacking bandwidth of 40Gbps and should support a minimum of 8 units in a stack Minimum one meter Stacking cables should be included in supplied material.Switch should support min 16 K MAC addresses and min 4000 active VLANs.Switch should have full Layer 2 features like STP, RSTP, MSTP/PVST, LACP/IEEE802.3ad, ACL, QoS and IGMPv1/v2/v3.Switch should have Static Routing for IPv4 & IPv6.Access Switch should be upgradable to support advance Layer 3 features like, RIPv1/v2, OSPF v2, OSPFv3, and HSRP/VRRP in future with an additional software license upgrade.Should support 4K IGMP Groups.Should support 8 queues per port and security protocols like RADIUS, TACACS/TACACS+, AAA & SSH.Switch should be quoted with 3 years direct OEM TAC support and Next Business day hardware shipment.Proposed switch should be IPv6 logo certified, including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUKUS/CISCO/HP
Supply Installation testing & commissioning of Category 6 Patch Cord 6.5 feet, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M
Supply Installation testing & commissioning of 24Port loaded Straight Jack pannel, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M
Supply Installation testing & commissioning of Horizontal PVC Cable Manager - 1U , including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M
Supply Installation testing & commissioning of 10GBASE-SR,SFPP MMF LC CONNECTOR with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUKUS/CISCO/HP
Supply Installation testing & commissioning of DIRECT ATTACHED SFPP ACTIVE COPPER with 10G speed, 1M with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUKUS/CISCO/HP
Supply Installation testing & commissioning of Video Management Recorder with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Main Processor : Intel Quad-core Processor or better, Operating System :Embedded LINUX,IP Camera Input : 32 Channel or More, Two-way Talk : 1 Channel Input, 1 Channel Output/RCA, Interface : ≥2 HDMI (up to 3840 x 2160 , Different Source), ≥1 VGA, Compression : H.265/H.264, Resolution : 12MP, 8MP, 6MP, 5MP, 4MP, 3MP, 1080P, 1.3MP, 720P etc., Bandwidth : >320Mbps,Record Mode : Manual, Schedule (Regular, MD (Motion Detection), Alarm, Analytics), Holiday, Stop, Video Detection : Motion Detection/ Video Loss and Tampering/ Multiple VCA Event, Alarm input : ≥16 Channel, Relay Output : ≥8 Channel, Search Mode : Time /Date, Alarm, MD / Smart Search, Backup Mode : USB Device/Network/eSATA Device, Network Interface : 4 RJ-45 Ports (10/100/1000Mbps), Ethernet Port : 4 Ethernet Ports Joint Working or 4 Independent 1000Mbps Ethernet Ports, Network Function : HTTP, HTTPs, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE,DDNS, FTP, Alarm Server, IP Search etc., Optical Fiber Interface : ≥2 Giga Optical Fiber Interface, User Access : ≥128 users, Smart Phone : iPhone, iPad, Android, Interoperability : ONVIF 2.4, CGI Conformant, Internal HDD : 16 SATA III Ports, Up to 8 TB capacity for each HDD, HDD Mode : Single, Raid 0/1/5/6/10, Support Global HDD Hot-spare, eSATA : 1 eSATA Port, SAS : 1 Mini SAS Port, for Storage Expansion,Front Cover : Support Hot-swap, USB : 4 USB Ports (2 USB 2.0 , 2 USB 3.0 ), RS232 : 1 Port, for PC Communication and Keyboard, RS485 : 1 Port, for PTZ Control, Power Supply,Redudant Power supply : Support, Operating Conditions : -10°C ~ +55°C, Certifications : CE,UL,FCC (NS) MAKE : DAHUA/HYUNDAI/HONEYWELL
Supply Installation testing & commissioning of 17 U Wall Mount rack with front glass door lockable, Fans 90 Cfm 230 Vac, PDU Horizontal 5Amp with 6 Schokets, Cantilever Tray-1U, Horizontal PVC Cable Manager and Hardware front panel Mtg. including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M
Supply Installation testing & commissioning of 6 U Wall Mount rack with front glass door lockable,. including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M
Supply Installation testing & commissioning of AP Management License with 3 years comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUCKUS/CISCO/ARUBA
Supply Installation testing & commissioning of 12-core Singlemode OM3 OFC including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.(NS) (MAKE : Molex/Siemon/Dlink)
Supply Installation testing & commissioning of Single mode Fibre Patch cord including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) (MAKE : Molex/Siemon/Dlink)
Supply Installation testing & commissioning of Black, 12F, L1U, Loaded with, Splice tray, Couplers & Pigtails including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) (MAKE : Molex/Legrand/Dlink)
Supply Installation Testing and Commissioning of Digital central controller for powering and controlling of discussion devices. The controller should have connections at rear to connect audio peripherals or conference dome cameras. The system settings such as microphone management should be configurable from software on a PC/tablet using web browser. The number of open microphones should be controllable from either the control unit itself or web based software. The controller should be able to accommodate upto 10 number of open microphones. The control unit should be capable of connecting to cameras for conference room, external wired/wireless microphone, sound reinforcement systems, audio equipment, external audio processor, telephone coupler, external recorder or computer. The control unit should have the following modes : Open mode - Participants speak by pressing their PTT button. When max no. of open mics reached the next participant is automatically waitlisted. Over ride mode - when max no. of open mics reached the first mic to be switched on is automatically switched off. Voice activated mode - mics switch on their own when participant speaks near the mic. PTT mode - Participant presses his PTT button and the mic is switched on till the time button is pressed. • Inbuilt MP3 recorder which can support upto 128GB flash drive or 4000 hours of discussion. • Inbuilt digital acoustic feedback suppressor to control acoustic feedback or howling in the system. • No. of discussion devices - max 40 per trunk line. • Sample rate 44.1kHz. • Frequency response - 30Hz - 20kHz. • S/N > 94dBA. Make:-Bosch/Brahler /Beyar Dynamic (NS)
Supply Installation Testing and Commissioning of digital chairman unit with priority, inbuilt speaker, PTT button and 48 cm long gooseneck microphone. The unit should have following features: • Possible to speak indicator - The microphone should have a white LED indication which shows when the microphone can be activated; • Request to speak indicator - the microphone should have a green LED indicator when the microphone is in queue to be activated; • Built in loudspeaker with volume controller; the unit shoul dhave built in head phone socket with volume control for the same. • The discussion unit should have immunity from mobile phone signals. • Frequency response - 200Hz-12.5kHz; • Loud speaker output - 72dB SPL Make:-Bosch/Brahler /Beyar Dynamic (NS)
Supply Installation Testing and Commissioning of digital delegate unit with inbuilt speaker, PTT button and 48 cm long gooseneck microphone. The unit should have following features: • Possible to speak indicator - The microphone should have a white LED indication which shows when the microphone can be activated; • Request to speak indicator - the microphone should have a green LED indicator when the microphone is in queue to be activated; • Built in loudspeaker with volume controller; the unit shoul dhave built in head phone socket with volume control for the same. • The discussion unit should have immunity from mobile phone signals. • Frequency response - 200Hz-12.5kHz; • Loud speaker output - 72dB SPL Make:-Bosch/Brahler /Beyar Dynamic (NS)
Supply Installation Testing and Commissioning of DSP with USB THD+N (22Hz to 22kHz) 0.002% (1kHz @ +4dBu)EIN <125dBu, unweighted (20Hz to 20kHz)Dynamic Range 110dB, unweighted,Propagation Delay 4ms, Crosstalk, input to input, 1kHz <110dB Sampling Rate 48kHz A/D-D/A Converters 32-bit Acoustic Echo Cancellation Requires HearClear™ license; 250ms latency at eight channels, 100ms at 16 channels BTU/Heat Load 44 BTU/hr, Processor Type 40-bit floating point Phantom Power +48VDC (with XC-SML) up-to 75mA maximum Power Supply IEEE 802.3af, Class 0 Power-over-Ethernet Power Consumption 13W maximum Ambient Operating Temperature 32-104°F (0–40°C) Humidity 0–98%, non-condensing Altitude 0-6,600 feet (0–2000 Meters) MSL Network Connections 2x RJ45 (≥Cat 5e) including dedicated 1000Mbps Dante™ connection and, separate Ethernet port for control and Power-over-Ethernet USB (with XC-SUB) Bit depth: 16-bit, Number of channels: 2x2, send and receive, Driver sample rate: 48kHz Card sample rate: follows DSP settings, Connector: USB B, female Dante™ 4x4 bi-directional; AES67.MAKE:- Xilica/Audio Technica/BSS/Bosch/Brahler /Beyar Dynamic (NS)
Supply Installation Testing and Commissioning of Amplifier Channels 4 Sensitivity (for full rated power at 8 ohms) 0.7V RMS Rated Power Output (per channel @ 4 ohms) 300W Analog Input Signal to Noise Ratio (ref. rated power, 100V, 20Hz - 20kHz) at 8 ohms) > 104dB THD (full rated power, 20 Hz - 20 kHz) 0.35% Damping Factor (20 Hz to 100 Hz) > 1000 Frequency Response (8Ω, 20 Hz - 20 kHz) +/-0.5dB Crosstalk (below rated power) 20 Hz to 1 kHz > 80dB Input Impedance (nominally balanced, nominally unbalanced) 20 kΩ balanced, 10 kΩ unblanced Dimensions (inches) (W x H x D) (depth not including 1.3 inch front panel protrusion) 19 x 3.5 x 12.25 Weight 16.13 lbs (7.31 kg) Power Supply Connector "Standard IEC type 320 inlet for detachable connector 100 – 240V~".Make:-Bosch/Brahler /Beyar Dynamic (NS)
Supply , Installation , Testing & Commissioning of Full HD 20X Optical Zoom Camera With HDMI, USB,,LAN ports features advanced ISP processing algorithms and exceptional Pan-Tilt mechanism to provide high resolution, vivid performance and smooth moves. HD Pan/Tilt/Zoom (PTZ) camera has USB 3.0 and HDMI and IP video output interface , equipped with a high performance imaging, fine detail, and color rendering with 1/2.8″ low-noise, HD CMOS image sensor with Full HD 1080p output resolution and a high dynamic image of 60 fps. The superior 20x optical zoom lens,wide shooting angle and achieves high-speed, quiet, and precise positioning with smooth PTZ operations. There are up to 255 preset setting movements and stable remote controlling for displaying effective and efficient presentations supports VISCA, Pelco-D, and Pelco-P camera control protocols TCP/IP, RS-232, USB, and IR control,remote control ,Minimum Illumination 0.5 Lux @ F 1.8 (AGC ON) ,Focal Length 5.5 – 110 mm (20x), F Number F1.6-F3.5, Field of View 55.8° (wide) – 3.2° (tele) , Pan/Tilt Rotation -170°∼+170°, -30°∼+90° , Network Protocol RTSP, RTMP, ONVIF , GUI-based configuration. Make:-Solvision/Panasonic/Sony (NS)
S.I.T.C. of 55" 4k Display panel for viewing content- LED display, HDMI X 2, DVI X 1, DP X 1, VGA X 1, Video IN X 1, Component x 1, USB X 2, RS232 X 1, Audio IN X1, 20W in built speaker, IPS LED display, USB media player, Auto Input search, Auto sleep, Auto wakeup, Auto source detect Make:-Panasonic/LG/Samsung (NS)
S.I.T.C. of 86" Intractive flat Panel, IR touch technology, IPS Panel UHD Native Resolution ( 3849 x 2160 ), Brightness 330 Nits; Contrast ratio 1100:1, response time :8ms, Orientation Landscape Connectivity. ( Input ) Video / Audio HDMI (3), RGB / Audio in(input) External Control rS232C In,RJ45 (Input) USB USB 2.0 (3, Front : 2ea, Bottom side :1ea Only for software. Audio HDMI (1), Optical Output / Audio Out with OPS i5 system Touch type IR. Available object size for touch Ø3 mm ↑ Response Time 60ms ↓ (Andriod) / 100ms ↓ (Windos) Accuracy 1.5mm Unreface USB 2.0 Protection Glass Thickness 4T (Anti - Glare) Make Panasonic,Samsung,LG, Sony, View Sonic etc. (NS)
Supply, Installation, Testing, Commisioing of Interactive Digital Podium system with 16" interactive screen EMR technology, also available Gooseneck Microphone inbuilt Aluminium plated system Interface : USB, Pressure sensitive. Still image Resolution: XGA,SXGA,720P, 1080P, FRAME RATE 20 FRAMES/SEC. Image Mode: Normal/photo/Text/Slide/Film/Gray. Inputs- VGAx 2, HDMIX 1, Video x 2, Audiox 2 Outputs- VGA x 2, hHDMIX 1 VIDEOX1 AUDIO X1. Make:-AHA/Digital Podium Media (NS)
Power Mixer - SITC of Powered Mixer ideal for installs with inbuilt class D amplifier , max. midband output power, 1 khz, THD = 1%, dual channel into 4Ω : 2 x 450 W into 8Ω : 2 x 270 W, also capable of Direct - Drive option for 100V speaker lines. Frequency reponse, -3db, ref. 1khz, any input to any Mixer output 15-22000 Hz. Crosstalk , 1khz Ampifier Ch1/Ch2˂ -85 db. 5 MIC/LINE input channels with compressor / limiter and talk over function, 3 Stereo inputs including jack, RCA and USB connecters, onboard player for MP3 or WAV audio files, high quality effects section with 32 editable presets, 3 master outputs with 7-bands EQ each and flexible signal routing options, delay line for Master-B (150msec) / 50m), Auxiliaries (FX,AUX) 1 Post 1 Pre, Input impedences MIC 2kΩ Cd 10kΩ All other inputs ˃ 15kΩ, headphones control, LPN speaker processing, comprehensive protection package, optional rack ,ount kit. Make Bosch /Bayerdynamics / Senneheiser etc. (NS)
Supply, Installation, Testing and Commissioning of XLR cables -of different sizes : Male,females, Speakon connectors, conducting, solding etc . (NS)
Supply, Installation, Testing and Commissioning of HDMI Cable 10 Meters For Lecture Hall : High Speed HDMI Cable; Ethernet, 3D, 4K, Audio Return Supported;Gold Plated Connector; Bare Copper Connector for high quality transmission; full metal jacket with shielding; 0% transmission loss. (NS) MAKE : Stacker/Aten/Kramer/TEKWIN/WBOX
S/I/T/C of 250KVA outdoor type non sealed three phase 50Hz 11/430/250 copper wound oil imersed naturally cooled distribution transformer complete with fitting and accessories inclusive of first filling of oil and confirming IS 1180/1989 ( Part-1 ) level 2 ISI Mark with Off Load Tap Changer. latest amendments BIS specifications complete in all respect Make Jaybee/Nucon/Kiroslker (NS)
Pdg. Platform for placing tranformer of size 10'x10'x4' consisting of 4" thick brick laid in cement sand mortar 1:6 and 6" thick cement concrete 1:1 1/2 :3 with stone agreegate 20mm nominal size for reinforced concrete work i.e steel reinforcement ,shuttering .6' high fencing/enclosure around platform cosisting of angle iron post of size 50mmx50mmx6mm thick embeded in cement concrete 1:2:4 block of sizes 1'-6x1'-6'x1'-6",3"x3" interlocking fencing made of 10 guage wire , 10mm dia plain wire on both (top & bottom) and openable door with locking arrangement etc. complete the job in all respect as directed bt Engineer-in-Charge. (NS)
S/E of 11 KV Gang operated switch i/c suitable size of copper blade & erection of the same on the existing H pole with the help of channels of size 75x40x6mm ( Heavy Duty )etc.Make Isotech/Rashtriya. (NS)
S/E of fabricated M.S. channel / M.S. angle iron / M.S. flat on PCC poles 11 mtr long as per ISI specifications etc. (NS)
S/E of nut and bolts of all sizes as per IS:1363/1966 nitch screw thread as per ISS:4218/1567. (NS)
S/E of 11 KV disc insulator with fitting on PCC pole as per HVPNL requirment complete in all respects. (NS)
S/E of pin insulator polymer type with 11 KV complete on PCC poles of approved make by HVPNL complete in all respects to the entire satisfaction of Engg-in-charge confirming to IS Part-II 1974 and IS : 2486 Part-I 1971 with 150mm threaded portion of 100 mm of GI pin to hold the insulator. (NS)
S/E of Disc type insulator polymer type with 11 KV complete on PCC poles of approved make by HVPNL complete in all respects to the entire satisfaction of Engg-in-charge confirming to IS Part-II 1974 and IS : 2486 Part-I 1971 with 150mm threaded portion of 100 mm of GI pin to hold the insulator. (NS)
S/E of stay set complete in all respects with stay wire and disc insulator comprising of MS rod of 18mm dia 1.8 mtr long to withstand 1000Kg load etc. (NS)
S/E of lighting arrestor set for 11 KV disribution system 5 KVA sets IS : 3870/1963 (NS)
S/E of LT fuse board with aluminium strip on Acrylic sheet (NS)
Mohit Construction Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid