Garrison Engineer (Maint) Infantry School , Mhow - 453441
REPAIR TO GATES BOUNDRY WALLS FENCING HARD STANDING AND PATHS INSIDE HQ INF SCHOOL AREA UNDER AGE BR II OF GE MAINT INF SCHOOL MHOW
2023_MES_622938_1
8600/GE(MIS)/MHOW
Open Tender
Civil Works
Item Rate
150 days
INFANTRY SCHOOL MHOW
All as per Tender document
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (Maint) Inf School
₹40,000
Yes
6 Dec 2023
12 Oct 2023
11 Nov 2023
12 Oct 2023
9 Nov 2023
26 Oct 2023
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/dense soil
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation,shafts, wells, cespits, manholes pier hold etc n.exc 10 Sqm on plan and getting out in Hard/dense soil complete all as specified
Returing, filling soil in trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified
Dismantling fencing wire mesh, any type
Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete ,any section, including taking out embedded portion and making good disturbed ground complete all as specified
Excavating post holes or similar holes, each not exceeding 0.5 cum , getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified
M&L for PCC 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate as in sub base, levelling course, etc complete all as specified
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire. complete all as specified
Supply only Chain link MS galvanised fencing of size or type
S & F 11 to 15mm dia of neck MS Screw bolts(Machine made ) with hexagonal or square heads at one end and screwed at other end or both end, and screwed end to be fitted with washer and one hexagonal or square n.exc 20 cm long etc complete all as specified
S&F Mild steel framed work as in doors or gates of angle iron, door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to fe 290 Gde E-165 complete all as specified
Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water etc complete all as specified
Demolition of brick work built in cement mortar including all quions ,arcches , pillars etc complete all as specified
M & L for Brick work with sub class 'B' modular bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 in any position complete all as specified
All as per item No 15 above but except brick. Note : Serviceable bricks obtain from demolition shall be re-used.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement complete all as specified
M&L for preparation of new plastered surfaces of walls and applying two coats of Acrylic Smooth exterior paint of required shade over a coat of primer of same make complete all as specified
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint all as specified
M&L for preparation of old surface of wall and applying two coats of cement base paint all as specified Note:- Before application of cement base paint , putty shall be carried out if required and putty shall be measured and paid seperately under relevant item .
M&L for providing and applying minimum 1mm thick wall care putty over prepared surface to achive the surface even and smooth for painting.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick ( below or above ground level ) complete including removal of debries out side MD land all as specified
M&L for PCC 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate as in sub base, levelling course, complete all as specified
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified
M&L for 75mm thick cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in floor/ plinth protection finish the surface even and smooth with using extra cement including filling the expansion joints with bitumen filler / filler boards and necessary form work etc complete all as specified
Demolition of Stone slabs and tiles of any description or thickness in floors complete all as specified and as directed.
M&L for chequered cement concrete tiles with grey cement and pigment of size 25cmX25cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified
M&L for chequered cement concrete tiles with grey cement and pigment of size 40cmX40cmX40mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified
M&L for machine cut kota stone slab in flooring 20-25mm thick laid over and including 15mm thick screed bed in CM 1:6 & cement mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified
M&L for 60mm thick machine pressed rubber moulded precast concrete interlocking paver block (glossy finish) of M35 Grade of approved shape, size and colour conforming to IS 15658-2006 and including joints filled with sand and 30mm thick stone dust as in levelling course of interlocking complete all as specified
M&L for 80mm thick machine pressed rubber moulded precast concrete interlocking paver block (glossy finish) of M40 Grade of approved shape, size and colour conforming to IS 15658-2006 and including joints filled with sand and 30 mm thick stone dust as in levelling course of interlocking complete all as specified
M&L for providing precast cement concrete louvers and jallies 50mm thick (measured solid) with cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate , set in cement mortar (1:4) including all mouldings but excluding frame complete all as specified
Dismantling of Asbestos cement (corrugated / semicorrugated etc.) sheets in roof coverings complete all as specified
S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified
Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in un-framed work complete all as specified
S&F Mild steel Hollow Section work in tubular trusses, purlins, rafter, tublar column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified
S&F Mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming IS-1161-1979 grade ST-240 complete all as specified
S&F Mild steel plates (Plain or chequered) as in shoe plate, base plate and gusset plates forming holes for roof frame work, trusses, rafters etc of grade Fe 410 WA. complete all as specified
S&F Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Preparation of new steel surface of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete complete all as specified
M&L for (SGSW) drain pipe of 150mm internal dia laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed including demolition ,breaking up drain pipe of any type ,any description ,earth work excavation in any type of soil , removing the debris and concrete bed and haunching from the trenches complete all as specified
M&L for PCC (1:3:6) type C 2 using 40mm graded aggregate as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested internal dia of pipe 150mm with specified bedding thickness, etc complete all as specified
Demolition of reinforcement cement concrete of any description and in any position in ground floor and pavings n.exc 15cm thick (below or above GL) complete
M&L for reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in Column, pillar, pies, post and strut complete all as specified and directed.Note: Reinforecement shall be measured and paid separately under relevant item.
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions finished fair complete all as specified
S&F in repairs precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate) as in coverslab of manholes and soak well cover slab etc set in cement mortar (1:4) etc with and including necessary form work complete all as specified and directe.Note:-Reinforcement shall be measured & paid separately under relevant item.
S&F TMT bars of 6 mm to 8 mm dia cut to length bent to shape required including cranking bending and binding with mild steel annealed wire not less than 0.90 mm dia or securing with clips complete all as specified
All as per Item No 47 here-in-before but 10 mm dia and over complete all as specified
M/S Sunshine Construction
NIDHI CONSTRUCTION
Chitragupta Construction
ss construction
sunrise enterprises
BHATIA ASSOCIATES
ram prashad chotelal batham
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .