| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-Finance 2 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-Finance 1st lowest | |
| 2 | L2₹3.0 L+₹19,284 (6.78%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹3.1 L+₹30,363 (10.7%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹5,729
Closing Date
10 Feb 2023, 12:30 pmClosed
Executive Engineer,Bankura Electrical Division,PWD
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Annual Maintenance of E.I. work at Main Hospital Building of Bankura Sammilani Medical College and Hospital, Bankura.-Repair a Renovation of 11-0.415 KV Indoor Sub-Station along with allied work at BSMCH in the District of Bankura- Gynee Portion
2023_WBPWD_466122_1
WBPWDTE/EE/BED/NIQ_129/Q of 2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Wise
7 days
Bankura Electrical Division
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,729
17 Feb 2023
3 Feb 2023
13 Feb 2023
3 Feb 2023
10 Feb 2023
3 Feb 2023
Amount
Gynee Sub-Station Transformer-1 Servicing of 11/.433 KV Step Down 250KVA ( Automatic Electro Gear) oil cool Transformer incl. H.T & L.T bushing incl. clening checking, testing etc as required incl. Testing the IR Value by Insulating testing Megger be for charging.
Lifting of core along with winding assembly by chain pully very precaousily incl. washing , cleaning by new transformer oil incl. drying properly by heat running for rising the IR Value.
Hiring charges of Chain pully incl. 3 nos GI pipe ialong with all required accessories.
S&F of Gasket to prevent the oil leakage 1no. for top cover LT & HT bushing incl. required accessories.
Dehydration and filteration of transformer oil of 2nos Transformer.
Di- electric test of transformer oil before filteration and after filteration as per direction of EIC.
Supplyand pouring of New Tranformer oil
Carrying charges of Transformer oil, filteration Machine, Testing machniary, Chain pully from Kolkata to work site and work site to kolkata
Supply of Silica Gel
Making End Termination of 3 core 300 sq.mm 11KV XLPE cable by Rachem Jointing Kits along with all required accessories
Testing of sub-station equipments such as 11KV/433V 250KVA Transformer and 11 KV HT OCB by special type testing instruments by scarching several hours detection to locate the fault of Sub-station equipments as per direction of E.I.C.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 3.5 core 240 sq.mm XLPE/PVC armoured cables
Finishing the end of 3.5 core 240 sq.mm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials
Supply and fixng Stud Bolt with Insulator at HT Side of the Transformer.
Gynee Sub-Station Transformer-2 Throughly servicing and overhauling of 1no. 800Amp HT VCB Panel Bus Bar ( PASCAL) and dismentling all components of electrical and mechnical portion incl. cleaning the dities, moisture of the BBC, HT bushing Spout, incl. V- contract, fingure contract by CTC oil and petrolium jelly after all necessary work and then testing of IR Value by 5000 Volt Insulating testing megger.
Servicing of 11/.433 KV Step Down 250KVA ( Automatic Gear) oil cool Transformer incl. H.T & L.T bushing incl. clening checking, testing etc as required incl. Testing the IR Value by Insulating testing Megger be for charging.
Lifting of core along with winding assembly by chain pully very precaousily incl. washing , cleaning by new transformer oil incl. drying properly by heat running for rising the IR Value.
Hiring charges of Chain pully incl. 3 nos GI pipe ialong with all required accessories.
S&F of Gasket to prevent the oil leakage 1no. for top cover LT & HT bushing incl. required accessories.
Dehydration and filteration of transformer oil of 2nos Transformer.
Di- electric test of transformer oil before filteration and after filteration as per direction of EIC.
Supplyand pouring of New Tranformer oil for washin of core
Carrying charges of Transformer oil, filteration Machine, Testing machniary, Chain pully from Kolkata to work site and work site to kolkata
Supply of Silica Gel
Supply , delivery and pouring of New Tranformer oil for washin of core
M/S N. C. HORE
GHANASHYAM ELECTRIC STORES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .