Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.0 L+₹60,324.75 (2.38%)Rejected-Finance | L2 | Rejected-Finance Higher Rate Quoted | |
| 3 | L3₹27.4 L+₹2.0 L (8.06%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L3 | Rejected-Finance Higher Rate Quoted | |
| 4 | L4₹28.4 L+₹3.1 L (12.2%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Higher Rate Quoted | |
| 5 | L5₹31.5 L+₹6.2 L (24.4%)Rejected-Finance | L5 | Rejected-Finance Higher Rate Quoted |
Tender Value
Refer Docs
EMD Value
₹61,000
Closing Date
19 Sept 2020, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Provn of Pipe Line for connecting CSTP to District Sewage collection Sump and certain sanctioned works at Air Force Station Jaisalmer
2020_MES_371546_1
8679/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹61,000
Yes
22 Oct 2020
24 Aug 2020
21 Sept 2020
24 Aug 2020
19 Sept 2020
7 Sept 2020
Amount
Supply, install, connecting & testing electric driven centrifugal monoblock pump set of capacity 20 HP, Three Phase, 50 Hz, 415 Volts, including necessary foundation and fixing arrangement complete all as directed. Make : Kirlosker/CG/Havells
S&F cast iron body sluice valve heavy duty class ‘PN-1.6’, 100mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing complete all as specified & directed. Make : Kirloskar/ L&T/ Leader /Venus/ Sant
S&F cast iron body sluice valve heavy duty class ‘PN-1.6’, 150mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing complete all as specified & directed. Make : Kirloskar/L&T/Leader/Venus/Sant
Supply, laying, jointing and testing centrifugally cast Ductile Iron spun pressure pipes (Class K-7) of 150mm bore with internal cement mortar lining and external zinc coating (130 gm/sqm minimum) and bituminous finish layer (minimum thickness 70 microns) with socket & spigot ends (ISI marked) conforming to IS 8329-2000 (latest revision) suitable for push on rubber gasket joint complete laid in trenches including taking down old unserviceable CI/DI pipe complete all as specified & as directed. Make: JINDAL/ELECTROSTEEL/ELECTROTHERM/TATA METALINKS.
M&L for galvanized steel water tubing medium grade of 150mm bore with & including all necessary fittings complete, laid in trenches, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for Mild steel water black tubing medium grade of 100mm bore with & including all necessary fittings complete fixed in opened, complete all as specified and directed.
Supply, laying and joing 160mm dia HDPE Pipe (By butt fusion welding method) in standard length BIS marked (high density polyethylene Pipe) HDPE pipe suitable for potable water as per IS specification No 4984/1995 (Pressure rating 10 Kg/Cm2 PE-100) and fittings (HDPE specials suitable to HDPE pipes) complete all as specified and directed by Engr-in-Charge.
S&F CI/DI special K-9 fittings (ISI marked) upto 150mm bore such as bends (any type, radius & angle), tapers any type (straight, bend, increasing, decreasing or double end socket etc), Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket & spigot), collars, caps & plugs suitable for spigot & socketed pipes, fixed, complete all as specified & directed.
Supply and Fixing cast iron Air valve flanged of class PN-1.6, 80mm dia ISI marked conforming to IS-14845-2000 heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint complete all as specified and as directed.
S&F CI reflex valve/Non return valve (NRV) of size 100mm bore, cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed by Engineer-in-Charge.
S&F Cast Iron foot valve of size 80mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed.
M&L for Constraction of brick masonary valves pit of size 900mm x900mm x90cm (internal dimention of chamber) made with sub class 'B' old size bricks, compressive strength not less than 75 Kg/sqcm bulit in cement mortar 1.6 for sluice valve chamber including necessary excavation, foundation concrete in PCC 1:3:6 type C1 using 20 mm graded stone aggregate and 15mm thick inside cement plaster with cement mortar 1:4 with floating coat of near cement, PCC coping type B1 (1:2:4) using 20mm graded stone aggregate with MS frame with angle iron 40x40x6 mm and cover of MS sheet 3.15mm thick including tarring and painting (where required ) the steel surface with two coats of synthetic enamel paint over a coat of red oxide prime complete as specified and locking arrangement directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 23 mm thick sand stone slab pit cover complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for Sub main wiring with 2x4 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour including drawn through PVC conduit suitable size complete all as specified and directed. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run PVC conduit suitable size shall be measured & paid as one unit.
M&L for Sub main wiring with 2x6 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 6 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour including drawn through PVC conduit suitable size complete all as specified and directed. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor and one run PVC conduit suitable size shall be measured & paid as one unit.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators including taking down old unserviceable point wiring complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly and including taking down old point wiring complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 16.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 16.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on same board.
All as per serial item No. 16.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board.
M&L for point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators including taking down old unserviceable point wiring complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly and including taking down old point wiring complete all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type, single pole, one way, 15 Amp, 230 Volts (ISI Marked) complete all as specified.
S&F socket outlet 2 in 1, 3 pin, 15 Amps flush type, (ISI Marked), 240 Volts complete all as specified.
S&F Modular switch 6 Amps, 250 Volt, AC, one way, one module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 00 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F Modular switch 16/20 Amps, 250 Volt, Single Pole, AC, one way with indicator one module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5720 63 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F Modular Socket shuttered, 6 Amps, 250 volts, 2/3 Pin combined, Single Pole, universal India two module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 70 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F Modular Socket shuttered, 6/16 Amps, 250 volts, 3 Pin combined, Single Pole, Indian two module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 71 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing ceiling rose surface bakelite 65mmx17.5mm with two or three terminal PVC/Polycarbonate, isolated body (ISI Marked) complete all as specified. Make : Havells/ABB/Philips
Supply and fixing Modular Metal flush mounting box of 3 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 08 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing Modular Metal flush mounting box of 4 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 09 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing Modular Metal flush mounting box of 6 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 10 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing Modular Metal flush mounting box of 8 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 42 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F white colour modular blanking plate, one module blank complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 5736 49 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing white colour plates with frame for modular switch of 3 module complete all as specified and as directed. Make : Legrand (Arteor) Cat Part No 5757 20 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing white colour plates with frame for modular switch of 4 module complete all as specified and as directed. Make : Legrand (Arteor) Cat Part No 5757 30 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing white colour plates with frame for modular switch of 6 module complete all as specified and as directed. Make : Legrand (Arteor) Cat Part No 5757 40 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing white colour plates with frame for modular switch of 8 module complete all as specified and as directed. Make : Legrand (Arteor) Cat Part No 5757 50 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT electric power cable (ISI marked) with aluminium stranded conductor 1100 volt grade cross sectional area 10 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cables 4 Sqmm complete all as specified.
M&L for dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
M&L for stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
S&F Ceiling Fan 1200mm sweep, Single Phase, AC supply, 240 Volt, including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 mfd, and including PVC insulated PVC sheathed copper conductor flexible 3 core cable 23/0.0076 from ceiling rose or connector to fan including marking of MES number complete all as specified and as directed by Engineer-in-Charge. Make : Crompton Greaves/ Bajaj/ Orient/ Havells. (Note : Length of suspension rod shall be adjusted by cutting, threading as directed and its cost is deemed to be included in rate of hanging of ceiling fan).
S&F Exhaust Fan 300mm sweep, BEE approved, ISI Marked with mounted in suitable opening arrangement with louvers and shutters suitable for operation on 240 volts, Single Phase, AC supply and connecting upto including three core PVC insulated PVC sheathed copper conductor flexible cable 23/0.0076 from ceiling rose or connector block including marking of MES number complete all as specified and directed. Make : Crompton Greaves /Usha/Bajaj/Orient/Havells.
S&F Flameproof LED Tube Light Fixture for 2 Piece Tube Light, EXTN2LT8-16/20, including 2 tube lights, batten suitable for Single Phase and twin T8 tube of 16W/20W and recommended for gas/vapor group of IIA & IIB and Zone 1 & 2, including integral reflector made of aluminium alloy expoy finish housing with die cast Aluminium, connector block, etc and all accessorie and incuding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make : Crompton Greaves Cat Part No. EXTN2LT8-16/20 or equivalent Havells/Polycab/Bajaj.
S&F and connecting LED flood light fittings on high mast pole pressure die cast housing with toughened glass and high power LEDs and secondary lanses with IP 66 protection high resistant tempered glass for protection with 5 KV surge protection applicable for large area lighting with efficient high output emitter LED for better distribution of capacity 80 watt (3000K 10 KV SPD included) complete all as specified. Make : Cat Part No LFL-80-CDL/60-M of Crompton Greaves or Orient/ Wipro /Bajaj/ Havells.
S&F capacity 20 Amp, metal clad box with top plug and socket, including 20 Amp, MCB SPN complete all as specified and directed by Engr-in-Charge. Make Siemens Cat Part No. 8GB0501RC and equivalent Havells.
S&F MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic protection type and making connections using suitable size copper lugs/thimbles and crimping tool, complete all as specified and directed. Make : Legrand Cat Part No. 4200 13 or Havells/Siemens/ABB/Indoasian.
S&F Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 415 Volts, 4 way, TPN DB, suitable for fixing MCB as outgoing and MCCB Triple Pole 100 Amp, rupturing capacity 25 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces and including taking down old unserviceable complete all as specified and directed. Make : Standard Cat Part No DSDNTHODIW04 equivalent in Legrand/ Indoasian/ Siemens/Schneider.
S&F Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 240 Volts, 8 way, SPN DB, suitable for fixing MCB as outgoing and MCCB Triple Pole 100 Amp, rupturing capacity 25 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces and including taking down old unserviceable complete all as specified and directed.
S&F Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 415 Volts, 8 way, TPN DB, suitable for fixing MCB as outgoing and MCCB Triple Pole 100 Amp, rupturing capacity 25 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces complete all as specified and directed. Make : Standard Cat Part No DSDNTHODIW04 equivalent in Legrand/ Indoasian/ Siemens/Schneider.
S&F MCB, TPN 40 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, and including taking down old unserviceable complete all as specified & directed. Make : Legrand/ Seimens/ Havells
S&F MCB, TPN 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 415 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, and including taking down old unserviceable complete all as specified & directed. Make : Legrand/ Seimens/ Havells
S&F MCB, SPN 10 to 40 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, and including taking down old unserviceable complete all as specified & directed. Make : Legrand/ Seimens/ Havells
S&F MCB, SP 10 to 40 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC, 50 Hz and making connections using suitable size copper lugs/thimbles, and including taking down old unserviceable complete all as specified & directed. Make : Legrand/Seimens/Havells
Supply, installation, hi wall Split type Air conditioning unit indoor/outdoor, electric driven single phase of capacity 2.0 TR (5 Star EER) complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality and connecting up all as per manufacturer’s instructions & as directed. Note :- Cost of cutting chases/cutting holes etc in walls/floors including making good in cement mortar 1:4 and other necessary arrangement for fixing indoor & outdoor unit & other minor extras shall be deemed included in quoted rate of this item.
Supply, installation, hi wall Split type Air conditioning unit indoor/outdoor, electric driven single phase of capacity 1.5 TR (5 Star EER) complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality and connecting up all as per manufacturer’s instructions & as directed. Note :- Cost of cutting chases/cutting holes etc in walls/floors including making good in cement mortar 1:4 and other necessary arrangement for fixing indoor & outdoor unit & other minor extras shall be deemed included in quoted rate of this item.
Supply, installation, window type Air conditioning, electric driven single phase of capacity 1.5 TR (5 Star EER) complete with cordless remote control and with in built air ioniser and plasma filter for better indoor air quality and connecting up all as per manufacturer’s instructions & as directed. Note :- Cost of cutting chases/cutting holes etc in walls/floors including making good in cement mortar 1:4 and other necessary arrangement for fixing indoor & outdoor unit & other minor extras shall be deemed included in quoted rate of this item.
Supply, installation and testing desert cooler electric driven single phase having normal air flow capacity 4000 Cum per Hour made out of GI plain sheet of 20 SWG and side panels of 22 SWG, front grill heavy duty having minimum weight 3.0 Kgs made out of GI sheet, wood wool pads (set of three) weight not less than 500 gms superior quality, including suitable motor, water pump, PVC pipe, PVC elbow, PVC distributor three way superior quality for desert complete all as specified and directed Make: Khaitan/CG/Polar/Symphony
Supply & fixing sheet metal enclosure with socket plug top and MCB Single Pole enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed. Make : Legrand/Indoasian/Siemens/Schneider.
M&L for 20mm bore Unplasticised PVC pipes of pressure rating 10 Kgfeet/Sqcm fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
M&L for Pre Stressed concrete Pole 9.00 mtr long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles complete all as specified and directed.
M&L for 25mm bore Unplasticised PVC pipes of pressure rating 10 Kgfeet/Sqcm fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
M&L for 40mm bore Unplasticised PVC pipes of pressure rating 10 Kgfeet/Sqcm fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
M&L for 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe complete as specified in SSR Part-I complete all as specified.
M&L for automatic chlorine dosing system with following arrangement Make : Declibac Model : ADS-Pro or equivalent. (a) Water inlet valve (b) Overflow valve (rubber guard included) (c) Outlet valve for standalone gravity flow (d) Outlet valve with automated flow (e) Drain valve (f) Level Controller (g) Level Gauge (h) Capacity 200 Litre (j) Shape Cylinderical
S&F 5 KVA Voltage Stabilizer complete all as specified and directed.
Supply and fixing 32 Amp industrial type socket three Phase, 440 volts complete all as specified.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out soft/disintegrated complete all as specified and directed.
Excavating in post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
M&L for 100mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in flooring, finished even and smooth with using extra cement complete all as specified and directed).
M&L for plain cement concrete (1:2:4) Type B-2 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete (1:3:6) Type C-2 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for Plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in plinth cources, parapets, copings, bed plates, surfaces channels, drains and like including weathering slightly rounded or chamfered angles and throating, necessary formwork as required etc complete all as specified
M&L for precast cement concrete 1:3:6, type C-1 using 20 mm graded stone aggregate solid block, exceeding 10cm in width as in block masonry built in cement mortar 1:6 complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in plinth protection, sub bases of floor or hard standing and finished even and fair surfaces complete all as specified and directed.
M&L for plain cement concrete (1:4:8) Type D-2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
S&F rolled mild steel work as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc. conforming to Gde E-250 (Fe 410-W) quality `A’ complete all as specified and as directed.
M&L mild steel work as in wind ties for roof covering including securing bolts etc. including all necessary drilling, bolting or riveting etc and similar work conforming to Gde E-165 (Fe-290) complete all as specified and directed.
S&F mild steel rolled sections as in column, vertical posts, main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle iron cleats or other connecting plates etc. conforming to Gde E-250 (Fe 410-W) quality `A’ complete all as specified and directed.
S&F mild steel in hollow section for trusses, rafters, stanchions and purlins trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 necessary welding, bolting, special shaped washer, clamps, cleats complete all as specified & as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) complete all as specified and directed by Engr-in-charge.
M&L for 10mm thick ceiling plaster in cement (1:4) on brick work or stone masonary surface on fair face of brick work or concrete surfaces or stone masonry surfaces of ceiling complete all as specified and directed.
M&L for 15mm thick plaster in cement (1:6) on stone masonary surface on other than fair face of brick work or on one side of lathing or concrete surfaces or stone masonry surfaces of wall complete all as specified and directed.
M&L for 15mm thick plaster in cement (1:4) on stone masonary surface on other than fair face of brick work or on one side of lathing or concrete surfaces or stone masonry surfaces of wall complete all as specified and directed.
Taking down cement plaster or cement lime plaster of any discription on brick or stone walls etc. including raking out joints hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for dubbing out average 10mm thick in cement plaster 1:4 on irregular surface of ceilings (when specifically ordered in writing) complete all as specified and directed. Note:- Plastering (if ordered) after dubbing out shall be measured & paid for under respective item.
M&L for Hardcore of guage not exceeding 63mm deposited spread and leveled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in flooring, plinth protection finished even and smooth with using extra cement complete all as specified and directed).
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:6 for storm water drains complete all as specified and as directed.
All as per serial item No. 94.00 but above except stone
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm in granite or trap stone work for random rubber walling uncoursed or brought upto courses complete all as specified.
M&L for Keyed pointing in cement mortar 1:4 to random or polygonal rubble walling, uncoursed or brought upto course stone masonry all as specified & directed.
M&L for plain cement concrete (1:2:4) Type B-1 (using 20 mm graded granite stone aggregate) as in surface channels and drains complete all as specified and directed by Engineer-in-charge.
M&L for providing cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping, plinth courses, kneelers, apex, stones, bed plates, water through, kerbs and the likes including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated wall surfaces of any description and applying one coat of oil emulsion distemper of any tint etc complete complete all as specified and directed by Engr-in-charge.
M&L for complete removal of existing treatment & preparation of old plastered surfaces or unplastered surfase of walls and applying two coats of distemper oil emullsion over a coat of chalk whitening complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces or unplastered surfase of walls and applying two coats of distemper oil emullsion over a coat of chalk whitening complete all as specified and directed.
M&L for preparation of newly plastered surfaces or unplastered sufaces and applying two coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of old treated/decorated wall surfaces and applying one coat of cement based paint in different tints in sigma/camouflage pattern as approved complete all as specified and directed.
M&L for preparation of newly plastered or unplastered of wall surfaces and applying two coats of cement based paint of different tints in sigma/camouflaging pattern as approved complete all as specified and directed by Engr-in-charge.
M&L for preparation of old painted wooden surfaces of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint any colour as approved complete all as specified and directed
M&L for preparation of old painted steel surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint any colour as approved complete all as specified and directed.
M&L for prepariation of newly or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for complete removal of existing treatment of wooden ply surfaces on wall including cleaning of old paints etc and preparation of surfaces any discription over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer any colour as approved complete all as specified and directed.
M&L for preparation of old treated/decorated wall/roof surfaces of any description by brooming down or steel wire brushing, scrapping down smoke soot and greasy spots and applying one coat of exterior emulsion paint (weather coat) 1st quality in different tints/shades sigma pattern/camouflage pattern any colour as approved complete all as specified & as directed.
S&F 0.60mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with J type hook and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified & as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing, culverts and similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs, culverts and sides of RCC/PCC bands in walls, horizontal or sloping and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Demolition of brickwork or stone/boulder masonry built in cement mortar for monsoon drain walls in portions including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
Demolition of plain cement concrete (unreinforced) in ground floors, wall and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced cement concrete as in culverts slabs, roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for 15-18mm thick green marble machine cut on vertical surfaces such as in treads, dado, skirting etc. jointed with grey cement slurry and pointing in green cement including cutting and mirror polishing over & including screed bed or bedding layer of 15mm thick in cement and sand mortar 1:4 complete all as specified & as directed.
Dismantling floor, hearth or wall tiling, stone partitions including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
S&F for joint free coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors over 15mm thick in cement and mortar (1:6) bedding set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified.
S&F for joint free coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm on vertical surfaces such as dado, skirtings and riser to steps over 10mm thick in cement and mortar (1:4) bedding set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified.
S&F 3mm thick sheet glass plain ordinary quality and glazing not exceeding 0.5 sqm in each pane without or securing with beads including Hacking out broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all necessary fittings complete to walls and ceilings or laid in floors, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all necessary fittings complete to walls and ceilings or laid in floors, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all necessary fittings complete to walls and ceilings or laid in floors, complete all as specified and directed.
S&F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 25mm bore galvanised iron pipe and fixed complete all as specified.
S&F Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 20mm bore pipe line complete all as specified & directed by Engr-in-charge.
S&F Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 25mm bore pipe line complete all as specified & directed by Engr-in-charge.
S&F Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all as specified & directed
S&F waste coupling of PTMT (half or full threaded) (minimum weight 60gms) suitable for 40mm bore pipe complete all as specified.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified.
S&F 15mm bore Stop valve fancy type of cast copper alloy chromium plated screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified.
S&F 15mm bore fancy type chromium plated Bib taps, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified
S&F 40mm bore of pipe low density polythylene pipes (LDPE) with fittings as required of pressure rating 6 kgf/cm2 and fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
Supply and fixing PVC connection 600 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
star electricals
M/s Shree Construction Company
SANJOLI CONSTRUCTION COMPANY
S.G.ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .