GE NAMS
GE NAMS AMRITSAR
IMPROVEMENT TO LT DISTRIBUTION SYSTEM, LT PANELS, LT OH LINES AND UG CABLE AT GE NAMS
2022_MES_570144_1
GE NAMS-74/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NAMS
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹90,000
Yes
17 Feb 2023
20 Dec 2022
19 Jan 2023
20 Dec 2022
17 Jan 2023
3 Jan 2023
Amount
Supply install, testing and commissioning in replacement LT Distribution Panel, Cubicle type, IP-56, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars of suitable size dully insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/ interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 90 CM long four legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:2:4, 15 CM thick in foundation, Brick (sub class B) work in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel 30CM below ground level and 60 CM above ground level, Rate for platform shall be included in the quoted rate, all as directed by Engr-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands.
The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :- Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.) Make of panel boards: Legrand, L&T, Shalabh, Schneider & ABB
Note :- (i) The panel Make should be CPRI approved. (ii) Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6, rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel. The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
Supply install, testing and commissioning in replacement LT Distribution Panel, Cubicle type,IP-56, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars of suitable size dully insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/ interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 90 CM long four legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:2:4, 15 CM thick in foundation, Brick (sub class B) work in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel 30CM below ground level and 60 CM above ground level, Rate for platform shall be included in the quoted rate, all as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,
The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.) Make of panel boards: Legrand, L&T, Shalabh, Schneider & ABB
Supply install, testing and commissioning in replacement LT Distribution Panel, Cubicle type,IP-56, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars of suitable size dully insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 90 CM long four legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:2:4, 15 CM thick in foundation, Brick (sub class B) work in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel 30CM below ground level and 60 CM above ground level, Rate for platform shall be included in the quoted rate, all as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,
The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.) Make of panel boards: Legrand, L&T, Shalabh, Schneider & ABB
Supply install, testing and commissioning in replacement LT Distribution Panel, Cubicle type,IP-56, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars of suitable size dully insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 90 CM long four legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:2:4, 15 CM thick in foundation, Brick (sub class B) work in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel 30CM below ground level and 60 CM above ground level, Rate for platform shall be included in the quoted rate, all as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,
The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.) Make of panel boards: Legrand, L&T, Shalabh, Schneider & ABB
APFC Panel Board 120 KVAR:- INCOMMING:- a) Busbar 4 Pole, Aluminum, 400 Amps-01 Set (b) MCCB 250 Amp 4 Pole, 36KA,with adjustable thermal setting alongwith spreader terminal -01No. (c) LED type Phase indicator lamp(RYB)-03 Nos d) Digital type multi function meter to measure V,A,F,PF with 250/5 CTs - 01 set. ( Make :- L&T/Legrand/AE/SIEMENS.) As outgoing :- (a) MCCB 63 Amp 3 Pole, 16/18KA,with adjustable thermal setting with spreader terminals -04 Nos. (b) MCB 32 Amp TP, 10KA, C Series- 02 Nos. APFC Relay 06 Steps with suitable CTs.- 01 Set. Capacitor, 480 volts, Heavyduty, Cylindrical type :- i) 25 KVAR- 04Nos, ii) 10 KVAR- 02Nos KVAR contactor suitable for Capacitor, 480 volts :- i) 25 KVAR- 04Nos, ii) 10 KVAR- 02Nos Auto / Mannual switch - 01 No ON - Indicating Lamp LED type 240 V AC, Red colour -06 Nos. ON - OFF push button, 240 V AC, Red / Green colour -12 Nos. Axial air circulation fan, 150 mm dia - 02 Nos. (b) MCCB 63 Amp 4 Pole, 16/18 KA,,with adjustable thermal setting alongwith spreader terminals & ROH -01No.
Note:- (i) The panel Make should be CPRI approved. (ii) Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
Supply install, testing and commissioning in replacement LT Distribution Panel, Cubicle type,IP-56, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars of suitable size dully insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 90 CM long four legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:2:4, 15 CM thick in foundation, Brick (sub class B) work in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel 30CM below ground level and 60 CM above ground level, Rate for platform shall be included in the quoted rate, all as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,
The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.) Make of panel boards: Legrand, L&T, Shalabh, Schneider & ABB
APFC Panel Board 160 KVAR:- INCOMMING:- a) Busbar 4 Pole, Aluminum, 600 Amps - 01 Set (b) MCCB 400 Amp 4 Pole, 36KA,with adjustable thermal setting alongwith spreader terminal -01No. (c) LED type Phase indicator lamp(RYB) = 03 Nos d) Digital type multi function meter to measure V,A,F,PF with 400/5 CTs - 01 set. ( Make :- L&T/Legrand/AE/SIEMENS.) As outgoing :- (a) MCCB 63 Amp 3 Pole, 16/18KA,with adjustable thermal setting with spreader terminals -06Nos. (b) MCB 16 Amp TP, 10KA, C Series- 02 Nos. APFC Relay 08 Steps with suitable CTs.- 01 Set. Capacitor, 480 volts, Heavyduty, Cylindrical type :- i) 25 KVAR- 06Nos, ii) 5 KVAR- 02Nos KVAR contactor suitable for Capacitor, 480 volts :- i) 25 KVAR- 04Nos, ii) 5 KVAR- 02Nos Auto / Mannual switch - 01 No ON - Indicating Lamp LED type 240 V AC, Red colour -08 Nos. ON - OFF push button, 240 V AC, Red / Green colour -16 Nos. Axial air circulation fan, 150 mm dia - 02 Nos.
Note:- (i) The panel Make should be CPRI approved. (ii) Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
Supply install, testing and commissioning in replacement LT Distribution Panel, Cubicle type,IP-56, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars of suitable size dully insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 90 CM long four legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:2:4, 15 CM thick in foundation, Brick (sub class B) work in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel 30CM below ground level and 60 CM above ground level, Rate for platform shall be included in the quoted rate, all as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,
The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.) Make of panel boards: Legrand, L&T, Shalabh, Schneider & ABB
Note:- (i) The panel Make should be CPRI approved. (ii) Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
Supply install, testing and commissioning in replacement LT Distribution Panel, Cubicle type,IP-56, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars of suitable size dully insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 90 CM long four legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:2:4, 15 CM thick in foundation, Brick (sub class B) work in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel 30CM below ground level and 60 CM above ground level, Rate for platform shall be included in the quoted rate, all as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,
The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.) Make of panel boards: Legrand, L&T, Shalabh, Schneider & ABBINCOMMING:-
Note:- (i) The panel Make should be CPRI approved. (iii) Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iv) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
Supply install, testing and commissioning in replacement LT Distribution Panel, Cubicle type,IP-56, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars of suitable size dully insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 90 CM long four legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:2:4, 15 CM thick in foundation, Brick (sub class B) work in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel 30CM below ground level and 60 CM above ground level, Rate for platform shall be included in the quoted rate, all as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,
The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.)
Note:- (i) The panel Make should be CPRI approved. (ii) Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate for Platform shall be included in the quoted rate.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed.
Description all as per srl item No 9 here-in-before but of size 120 Sqmm 3.5 core.
Description all as per srl item No 9 here-in-before but of size 95 Sqmm 3.5 core.
Description all as per srl item No 9 here-in-before but of size 70 Sqmm 3.5 core.
Description all as per srl item No 9 here-in-before but of size 50 Sqmm 3.5 core.
Description all as per srl item No 9 here-in-before but of size 35 Sqmm 3.5 core.
Description all as per srl item No 9 here-in-before but of size 25 Sqmm 4 core.
Description all as per srl item No 9 here-in-before but of size 16 Sqmm 4 core.
Description all as per srl item No 9 here-in-before but of size 16 Sqmm 2 core.
Supply, laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) of size 50mm outer dia and 38mm inner dia with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc all as specified and directed by Engr in Charge. Make;-Telerex/Tirupati or E-in-C approved Make
Description all as per srl item No 18 here-in-before but of size 90mm outer dia and 76mm inner dia.
Description all as per srl item No 18 here-in-before but of size 77mm outer dia and 63mm inner dia.
Material and Labour in replacement straight through joint Cold shinkable suitable for 50 to 185 sq mm 3.5 core 1100 volts XPLE cable type complete all as specified and directed.
Exacavation for cable loops near the poles LT Panels transformers, cutting the damages/ burnt parts of cable and reconnecting to its positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip or strip to earth plate to be fixed with welded joints.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009.
M & L in replacement of MCCB Capacity 400 Amp 36 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 250 Amp 36 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 160 Amp 36 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 100 Amp, 16 ka, 3 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M & L in replacement of MCCB Capacity 200 Amp, 36ka, 4 pole adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existing LT Panel.
M&L in replacement for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with numeric, letters in \hindi, English and including local language and conventional skull and bones in signal red and fixed with MS Clamps, bolts and nuts of approved size for LT, 20x 15 cm complete all as specified and as directed.
Restrainging of ACSR conductor HT/LT by providing suitable proper sag all as specified and directed.
Supply & fixing in repair of LT stay assembly comprising of 7/3.15mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm incl necessary Excavation and PCC all as specified and directed by Engr-in charge
Supply and laying in repair GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete all as specified and directed.
Excavation trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in type of soil all as specified and directed.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
M & L in replacement of out door type aluminium bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts of size 90 x 60 x 45 cm including incommer MCCB 300 Amp 4 Pole with extended front operating rotary handle, made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.60 mtr high from ground level and 0.40 M below the ground level all as directed by Engr-In-Charge. Note : Contractor is responsible to produce drawing and take approval before placing order.
M & L in replacement of out door type aluminium bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts of size 90 x 60 x 45 cm including incommer MCCB 250 Amp 4 Pole with extended front operating rotary handle, made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.60 mtr high from ground level and 0.40 M below the ground level all as directed by Engr-In-Charge. Note : Contractor is responsible to produce drawing and take approval before placing order.
UNITED ENGINEERING CORPORATION
kailu construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .