| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹10.4 L+₹66,202 (6.78%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹11.0 L+₹1.2 L (12.6%)Rejected-AOC 397 JASPREET SALUJA INDORE VISHNUPURI ANNEX INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹11.1 L+₹1.3 L (13.2%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹11.3 L+₹1.6 L (16.2%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
11 Mar 2020, 5:00 pmClosed
GE of GE (SOUTH) AKHNOOR
GE SOUTH AKHNOOR C/O 56 APO PIN- 900234
REPAIR TO INTERNAL ELECTRIFICATRIONS/ WIRING, FANS, GEYSERS AND SUMMER APPLIANCES WITH CONNECTED ITEMS AT PALLANWALA AREA UNDER GE (SOUTH) AKHNOOR.
2020_MES_328548_1
NIT-41
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PALLANWALA AREA
Class E and Category b(i)
8 documents required · 8 mandatory
₹500
GE SOUTH AKHNOOR
₹20,000
Yes
27 Apr 2020
25 Feb 2020
12 Mar 2020
25 Feb 2020
11 Mar 2020
6 Mar 2020
Amount
SCHEDULE 'A' PART-I : BOQ OF WORKS FOR INTERNAL ELECTRICFICATIONS (WIRING) WORKS.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed by Engineer-In-Charge.
Taking down unserviceable any type of submain wiring etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface, complete all as specified and as directed by Engineer-In-charge.
Point wiring (in existing concealed conduits to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in exisiting any type of conduit, of any dia including all accessories concealed in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 4.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Description all as serial item No- 4.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 4.00 here-in-before but for one light point controlled by two way switches.
Sub main wiring (in existing concealed conduits to surfaces) for circuits/ sub main wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 8.00 here-in-before but for sub main wiring (in existing concealed conduits to surfaces) alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts.
Point wiring (in existing concealed conduits to surfaces) for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including any type of conduit, any dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, two way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
Bell push switch, single pole, one way, flush type, 5-Amps, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Door bell, AC, 230 Volts, single pole, ding-dong type sound, completeall specified and as directed by Engineer-In-charge.
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
LED retrofit lamp, T-shape, capacity 12 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ white light, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- NU Bulb Plus 12 W 865 B22 3 Star (Ordering code-LHLDEUECNL8R012)/ Philips/ Osram/ Crompton.
LED tube light fitting, 20 watt, indoor decorative high lumen batten, including LED lamp 20 Watt (yellow/white) and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- E-Lite LED Curve LHEXACP7IN1W020 or equivalent in Cromtopn/ Philips.
Environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt, complete all as specified. Make: Compact ordering cat part No- HEXAFT10WLED857SSYMBOPC or equivalent in Crompton/ C&S/ Bajaj.
LED tube light fitting, 1-feet long, indoor decorative high lumen batten, including LED lamp 5 Watt (yellow/white) and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed. Make: C&S cat part No- LTTB1F5WLED/W or equivalent in Bajaj/ Philips/ Wipro.
Ceiling light, size 600x600mm, with bright LEDs of 36 Watt, having superior illumination, complete all as specified and directed by Engineer-In-Charge. Make: Crompton cat part No- CCR-127-36-57-SL-NWH (Aura-I) or equivalent in Phillips/ Havells/ Wipro.
Street light fitting, Pressure die-cast IP 66 LED street light, including LED lamps of 30 to 36 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- Endura Pearl SL30WLED757SASYTOPCMP/ Philips ordering code No- 910925863567 (Product Code: 871869637692800)/ Bajaj cat part No- 169913 .
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 20 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Triple Pole and Neutral, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Triple Pole and Neutral, 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for laying electric cables or foundation of poles etc, complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 41.00 here in before but for cross-sectional area 16.0 Sqmm, 2.0-core,.
Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 16.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
Sheet metal enclosures for Triple Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
Modular switch piano, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Modular socket outlet, 2-in-1, 3-pin, 5-Amps, complete all as specified and as directed by Engineer-In-Charge.
Modular Switch socket combination 6Amps/ 16Amps, 2/3-pin combined, one-module, complete all as specified and as directed by Engineer-In-Charge.
Modular white cover plate, 2 to 4 module, complete all as specified and as directed by Engineer-In-Charge.
Modular metal boxes suitable for modular wiring, 2 to 4 module, complete all as specified and as directed by Engineer-In-Charge.
Taking down the existing geyser, of any capacity and any make/ design (Vertical or horizontal) for repair/ servicing by disconnecting the electric and water supply connections including cleaning the inner tank of geyser and re-installing after repair/ servicing including making electric and water supply connections and making good to the disturbed portion of the wall including testing and checking for proper functioning of thermostat, heating element, indication lamps, cable connections, 15 Amps socket and plug top, inlet and outlet water pipes etc, complete all as specified and as directed by Engineer-In-Charge. Note: Spare parts shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, repairing, tools and plants shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs geysers (capacity as mentioned) :-
Copper inner tank of existing shape, size and specifications including filling glass wool as insulating material, for geysers of 25 liters capacity, complete all as specified and directed by Engineer-In-Charge.
Copper inner tank of existing shape, size and specifications including filling glass wool as insulating material, for geysers of 50 liters capacity, complete all as specified and directed by Engineer-In-Charge.
Geyser water heating elements 1.50 KW, ISI marked, as per existing pattern fitted in the geyser, complete all as specified and as directed by Engineer-In-Charge.
Geyser water heating elements 2.00 KW, ISI marked, as per existing pattern fitted in the geyser, complete all as specified and as directed by Engineer-In-Charge.
Thermostat switch of existing specifications and having automatic cut off system, for geysers of 25/ 35/ 50 liters capacity, ISI marked, complete all as specified and directed by Engineer-In-Charge.
Safety brass valve, fusible, as per ISI specifications, suitable for geysers of 25/ 35/ 50 liters capacity, complete all as specified and directed by Engineer-In-Charge.
Non return valve, as per ISI specifications, suitable for geysers of 25/ 35/ 50 liters capacity, complete all as specified and directed by Engineer-In-Charge.
Dead nut for drain point, suitable for geysers of 25/ 35/ 50 liters capacity, complete all as specified and directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC connections with new PVC connections steel wire spirally reinforced, 15mm size, 450mm long with brass union at both ends, for outlet water supply, complete all as specified and directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC connections with new PVC connections steel wire spirally reinforced, 15mm size, 600mm long with brass union at both ends, for outlet water supply, complete all as specified and directed by Engineer-In-Charge.
Internal water assembly of existing shape, size and specifications including required rubber gaskets, nuts, bolts and washers, for geysers of 25 liters capacity, complete all as specified and directed by Engineer-In-Charge.
Internal water assembly of existing shape, size and specifications including required rubber gaskets, nuts, bolts and washers, for geysers of 50 liters capacity, complete all as specified and directed by Engineer-In-Charge.
Water heater storage type (geyser), wall hanging, capacity 25 Litres, energy saving high density PUF insulation, BEE rating Five (5) Star, 230 Volts, single-phase, 50 Hz AC, rated power input not less than 1000Watt, complete all as specified. Make: Havells cat part No- Monza DX (GHWAMGSIB025)/ Bajaj cat part No-Calenta/ Jaquar cat part No- EPM-WHT-V025 (Elena Prime)
Spray painting of geysers with two coats of synthetic enamel paint of white colour by spraying machine including repairing by gas welding, filling cavities with filler, after cleaning all dusts and removing of dent from surfaces of outer metallic body including writing of MES Nos. with synthetic enamel paint of black colour on peripheral of geysers capacity of 25 litrs, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of geysers with two coats of synthetic enamel paint of white colour by spraying machine including repairing by gas welding, filling cavities with filler, after cleaning all dusts and removing of dent from surfaces of outer metallic body including writing of MES Nos. with synthetic enamel paint of black colour on peripheral of geysers capacity of 50 litrs, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections and transporting water coolers of any type and of any capacity, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the water storage tank, compressor and outer body, tightening the hinges/ screws and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required of water coolers, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of water coolers (capacity as mentioned) :-
Hermetic sealed unit, for water cooler capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.
Hermetic sealed unit, for water cooler capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.
Condensor fan motor of 1/8 HP for water cooler, capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.
Condensor fan motor of 1/8 HP for water cooler, capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.
Over load protection relay for water cooler of any capacity, complete all as specified and as directed by Engineer-In-Charge.
Starting relay/ open type relay for water cooler, capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.
Starting relay/ open type relay for water cooler, capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.
Automatic thermostat suitable for water cooler any descriptions and of any capacity, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 40/80 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 60/120 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections and transporting refrigerator of any capacity and any type, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the internal surfaces and racks, compressor and outer body and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and spare parts such as lubricating oil/ grease of refrigerator required being repair/ replaced, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of refrigerator (capacity as mentioned) :-
Hermetic sealed unit uncut, capacity 1/8 HP, suitable for refrigerator of 165 to 210 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 285 to 330 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
Starting relay for refrigerator capacity 310 Litres, complete all as specified and as directed by Engineer-In-Charge.
Over load protection relay, 1/6 HP for refrigerator of 300/310 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
Thermostat with auto defrost button for refrigerator of any size and any descriptions, capacity 310 Litres, complete all as specified and as directed by Engineer-In-Charge.
Freezer chest including door with proper insulation, rubber seal and spring system, for refrigerator of 165 to 330 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
Crisper tray suitable for refrigerator of 300/310 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
Evaporator coil for refrigerator, capacity 165 to 180 liters, complete all as specified and as directed by Engineer-In-Charge.
Evaporator coil for refrigerator, capacity 210 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
Condensor fan motor of 1/8 HP for refrigerator, capacity 210 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
De-frost timer TMDE706 SC cycle time 6H35M, 60 Hz/ 7H54M, 50 Hz, single phase, 220- 240 Volts, suitable for deep freezers, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for refrigerator, capacity 165 to 210 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for refrigerator, capacity 285 to 330 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections of Deep freezer of any type and any capacity, for repairing and servicing, by cleaning/ washing the internal chamber, compressor, evaporator (indoor unit), condenser and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site, labour for repairs, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of Deep freezer :-
Hermetic sealed unit (compressor unit), capacity 2.50 Ton, uncut, suitable for deep freezer, complete all as specified and as directed by Engineer-In-Charge.
Printed Circuit Board, three phase, suitable for walk in freezer, any type, and as per existing specifications, complete all as specified and as directed by Engineer-In-Charge.
Condensor fan motor of 1/8 HP for Deep freezer, capacity 250 to 350 liters, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for air conditioner of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified.
Disconnecting all electric connections and taking down of air conditioner of any capacity, split type, installed at the site or mounting at any height and transport to MES store yard/ workshop for servicing, cleaning/ removing the dust internally and externally, replacement of defective spare parts, as required including washing/ cleaning the outer surfaces, evaporator, condensor, air filters, ground chassis including making dry after washing, lubrication to rotatory parts, testing after repairs including making necessary connection to the power point (if required), complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, labour required for repairs/ replacement of spare parts being repair/ replaced, shall be deemed included in quoted rate.
Description all as serial item No- 70.00 here-in-before but for air conditioner of any capacity, window type.
Supply only following new spare parts required to replacement for repairs of air conditioner (capacity as mentioned) :-
Hermetic sealed unit (compressor) suitable for window type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 2.0 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
Printed circuit board suitable for split type, uncut, for air conditioner of 1.50/ 2.0 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
Motor for condensor of air conditioner, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
Condensing coil for air conditioner of 1.50 Ton capacity, window type, complete all as specified and as directed by Engineer-In-Charge.
Condensing coil for air conditioner of 1.50 Ton capacity, split type, complete all as specified and as directed by Engineer-In-Charge.
Evaporator coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
Over load protection relay, air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
Starting relay for air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
Starting relay box for air conditioner, capacity 1.50 Ton, split type, complete all as specified and as directed by Engineer-In-Charge.
Front grill for air conditioner of 1.50 Ton capacity as per existing specifications, for split type, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for air conditioner of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified.
Copper tubes, size 3/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
Taking down existing desert cooler of any capacity, mounting in any locations and transporting to MES store yard/ workshop for carrying out necessary repairs, servicing, oiling/ lubricating, cleaning the water tank, motor, blades and testing, return the same after carrying out necessary repair work installation at site or other location, including repairs of defective cable connections and making connections of indicating lamps, PVC water pipes and elbow etc, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Spare parts shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, repairs shall be deemed included in quoted rate. (ii) Cost of minor spare parts such as PVC elbows, flexible pipes, lubricants, rubber pads and wire mesh shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of desert cooler (capacity as mentioned) :-
Submersible water pump (tullu pump), AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size, specified and as directed by Engineer-In-Charge.
Fan motor, AC operated, single phase, three wires, capacity 1/7 HP, 240 volts suitable for desert cooler and making necessary electric connection and fixing mild steel arms, specified and as directed by Engineer-In-Charge.
Fan blade (Set of three), mild steel, existing size, with fixing screws with motor, suitable for dessert cooler, specified and as directed by Engineer-In-Charge.
Mild steel front grill of 20 gauge thick metal sheet including movable louvers fins, powder coated paint, for desert cooler of any descriptions, specified and as directed by Engineer-In-Charge.
Mild steel side, back grill of 20 gauge thick metal sheet including louvers fins, powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, specified and as directed by Engineer-In-Charge.
Wooden wool/ grass pads for three sides including binding with GI wire tightly, for desert cooler of any specifications, complete all as specified and as directed by Engineer-In-Charge.
Desert cooler, electric driven copper wounded motor, single phase, 500mm metallic sweep cooler fan, 1400 rpm, 230 Volt, 50 Hz, air delivery capacity 4500 Cum/Hr, three speed regulator (high/medium/low) with metallic blade and mild steel body, duly painted with synthetic anti-corrosive oven cured paint, submersible pump 40 Watt (approx.), speed 1300 rpm, 230 Volts, 50 Hz and including wood wool pad of proper thickness and 2.50Sqmm three core copper wire with connecting top plug, complete all as specified and as directed. Make of motor: Khaitan/ Usha Lexus/ Orient/ Crompton.
Disconnecting all electric connections from mains and transporting voltage stabilizer of any type and of any capacity, to MES store yard/ workshop for repairing/ servicing, by cleaning the outer body and replacement of defective spare parts including testing after repairs and making necessary connection with power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required to replaced shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required being replaced of voltage stabilizer, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of voltage stabilizer (capacity as mentioned) :-
Printed circuit board with condesor choke and time delay relay, suitable for voltage stabilizer capacity 2.0 to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
Replacement of unserviceable voltage stabilizer with new voltage stabilizer, single phase, naturally air cooled, indoor type, working voltage range (input), 170 Volts to 270 Volts, current capacity upto 12 Amps, 3.0 KVA capacity, with accuracy of ±2.50%, complete all as specified and as directed by Engineer-In-Charge.
Replacement of unserviceable voltage stabilizer with new voltage stabilizer, single phase, naturally air cooled, indoor type, working voltage range (input), 170 Volts to 270 Volts, current capacity upto 12 Amps, 5.0 KVA capacity, with accuracy of ±2.50%, complete all as specified and as directed by Engineer-In-Charge.
Rewinding of transformer of voltage stabilizer capacity 02 KVA to 03 KVA, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge. Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of transformer of voltage stabilizer capacity 05 KVA, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge. Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Taking down carefully existing ceiling fans, of any make and size from existing positions after disconnecting electric connections, sealing cable end, dismantling/ removing blades carefully after un-screwing nuts, bolts, washers and removing fan and blades to store for repairs, overhauling, oiling, cleaning all dusts and inspaction for burnt coils including minors items as required for smooth functioning of fans, complete all as specified and as directed by Engineer-In-Charge. Note: Spare parts like ball bearings, gun metal bush, capacitors, canopy and rewinding/ painting shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, tools and plants shall be deemed included in quoted rate.
Supply only following new spare parts required for replacement for repairs fan of any sweep size :-
Ball bearing suitable for ceiling fans of any type and size as existing, complete all as specified and as directed by Engineer-In-Charge.
Bush made out of Gun metal suitable for ceiling fans of any type and size as existing, complete all as specified and as directed by Engineer-In-Charge.
Capacitors, capacity 2.50 mfd, suitable for ceiling fans of any type and size, complete all as specified and as directed by Engineer-In-Charge.
Canopy suitable for ceiling fans of any type and size as existing, complete all as specified and as directed by Engineer-In-Charge.
Aluminium blade (sweep) for ceiling fan of 1200mm sweep, complete all as specified and as directed by Engineer-In-Charge.
Hanging arrangement for ceiling fan, where ever required, made of mild steel hook, 15/ 16mm bore, 600mm long, hollow pipe as down rod, including flat iron clamps, nuts bolts and washers at upper end, complete all as specified and as directed by Engineer-In-Charge.
Mild steel clamps with rubber reels, nuts, bolts and locking pin of any type and size suitable for ceiling fans for hanging, complete all as specified and as directed by Engineer-In-Charge.
Hanging only ceiling fans after repairing at any location as required and making connecting from ceiling rose to connector of ceiling fan including provision of cable from ceiling rose or connector to fan, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of ceiling fan sweep size1200mm/ 1400mm, with synthetic enamel paint of white colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. on bottom of fan with synthetic enamel paint of black colour, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of worn out/ burnt out windings of ceiling fan 1200 mm sweep and re-winding the ceiling fan with the super enamelled copper wire of same size and same specifications including varnishing with approved quality, insulating materials and replacement of split/ safety pins, locking nut, check nuts, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of worn out/ burnt out windings of ceiling fan 1400 mm sweep and re-winding the ceiling fan with the super enamelled copper wire of same size and same specifications including varnishing with approved quality, insulating materials and replacement of split/ safety pins, locking nut, check nuts, complete all as specified and as directed by Engineer-In-Charge.
Ceiling fan, mettalic, sweep 1200mm, five star rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHCVESTWHT48 (Velocity)/ Crompton Greaves Entrust 50/ Usha Ergo/ Bajaj Electra 50/ Orient Electric energy star
Ceiling fan, mettalic, sweep 1400mm, five star rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHCSSSTWHT56 (SS 390)/ Crompton Greaves/ Usha/ Bajaj/ Orient.
Taking down carefully existing exhaust fans of any make and sizes from wall, cleaning externally, checking for defects and overhauling complete by opening, cleaning of bearing, stator, rotor winding, providing new fresh proper grade lubricants oil/ grease after cleaning and re-assembling after replacement of split/ safety pins, mild steel nuts and bolts, including replacement of old existing flexible cord connected from ceiling rose to fan, re-fixing the same in existing position or any other location, complete all as specified and as directed by Engineer-In-Charge. Note: Spare parts like ball bearings, gun metal bush, capacitors and rewinding/ painting shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, tools and plants shall be deemed included in quoted rate.
Supply only following new spare parts required for replacement for repairs exhaust fan of any sweep size :-
Ball bearing suitable for exhaust fans of size from 275mm to 375mm sweep, complete all as specified.
Description all as per serial item No- 93.01 here-in-before but for Exhaust fan of 375mm to 450mm sweep size.
Louver shutters including nuts, bolts and washers suitable for exhaust fans of size 275mm to 375mm sweep, complete all as specified.
Louver shutters including nuts, bolts and washers suitable for exhaust fans of size 375mm to 450mm sweep, complete all as specified.
Dismantling of worn out/ burnt out windings of Exhaust fan of 275mm to 375mm sweep and re-winding the exhaust fan with the same size of super enamelled copper wire, varnishing with approved quality insulating varnish including replacement of split/ safety pins, rusted nut, bolt and washer, complete all as specified.
Description all as per serial item No- 94.00 here-in-before but for Exhaust fan of 375mm to 450mm sweep size.
Spray painting of Exhaust fan of any size sweeps, with two coats synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on motor of exhaust fan, complete all as specified and as directed by Engineer-In-Charge.
Exhaust fan, mettalic, sweep 300mm, five star rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHVVEMTDBB12 (Ventilair DB)/ Crompton Greaves/ Usha/ Bajaj/ Orient.
Exhaust fan, mettalic, sweep 250/ 230mm, five star rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHVDBMTGRY09 (Ventilair DB Neo)/ Crompton Greaves/ Usha/ Bajaj/ Orient.
PVC insulated FRLS cable with PVC insulated, unsheathed, multi-stranded copper conductor 1100 volt grade, size 2.50 Sqmm, three core for connection, complete all as specified and as directed by Engineer-In-charge.
Replacement of old unserviceable/ damaged plug top with new plug top, 15 Amps, 3-pin, 240 volts, metal clad, complete all as specified and as directed by Engineer-In-Charge.
Bib taps, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable ball valves with new ball valve, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified.
Replacement of old unserviceable push button bib tap with new push button bib tap, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, complete all as specified.
Electrical power tool kit having different type of tools as per Bosch cat part No- GSB13 RE, complete all as specified and as directed by Engineer-In-Charge. Make: Bosch/ Taparia/ Y-king.
Digital earth resistance meter (earth tester) with tool kit, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 4.0mfd, suitable for dessert cooler, exhaust fan, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged capacitor with new capacitor, 36mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged capacitor with new capacitor, 45mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 40/ 60mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 80/ 100mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 100/ 120mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged plug top with new plug top, 15 Amps, 3-pin, 240 volts, bakelite, complete all as specified and as directed.
Plug and socket board, metal enclosure with 2-pole and earth, including MCB 20 Amps Single Pole and Neutral and all internal wiring with copper wire, making necessary connections, complete all as specified. Make: Havells cat part No- DHDPUSN020/DHDPUDP020 or equivalent in ABB/ Legrand/ L&T.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 4.0mm dia GI wire as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Amount of Schedule of credit of for Rs 34,264.50 shall be deducted from quoted amount.
M/S BIJRAL ENTERPRISES
M/S ANMOL TRADING CO
M/S NISSAR ALI
M/S SHARMA ENTERPRISES
M/S CJ CONSTRUCTIONS
M/S SWARN ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .