| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | ₹7.1 L | L1 | Accepted-AOC BeingL1 |
| 2 | L2₹7.4 L+₹25,051 (3.51%)Rejected-Finance | ₹7.4 L+₹25,051 (3.51%) | L2 | Rejected-Finance quoted amount is higher than 1st lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not recommended since does not have required category. |
Tender Value
₹8.1 L
EMD Value
₹16,200
Closing Date
16 Dec 2024, 6:00 pmClosed
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
COMPREHENSIVE MAINTENANCE TO ETP (EFFLUENT TREATMENT PLANT) AND MECHANICAL LAUNDRY AT 6 AIR FORCE HOSPITAL
2024_MES_685397_1
8022_E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Coimbatore
Class-E category-c (vii) or d (v) (see NIT for detail)
8 documents required · 8 mandatory
₹500
AGE I AF Coimbatore
₹16,200
Yes
24 Jan 2025
23 Nov 2024
18 Dec 2024
23 Nov 2024
16 Dec 2024
2 Dec 2024
23 Nov 2024 - 30 Nov 2024
Amount
M&L for Comprehensive maintenance, preventive / periodical, routine and corrective (break down), maintenance, servicing, cleaning, inspection and testing of 10 KLD Effluent Treatment plant of Make : Gram including regular operation and maintenance, water & electricity operation, complete set of tools required for maintenance and operation, first aid kit box, casual labour for house keeping, damaged and broken spares of plant such as LDPE tank, diaphragm dosing pump, reaction tank with agitator, pressure sand filter, Carban filter, maintaning lab analysis reports every month, chemical, consumbles and all other things which is required for ETP and operators for ETP complete all as specified and directed.
M&L for collection of analysis of effluent sample from 10 KLD ETP plant and testing the sample by Govt Approved lab as per IS-10044 complete.
Supply only cationic polymer. Make : As recommended by OEM.
Supply only Anionic polymer. Make : As recommended by OEM.
Supply only Caustic soda. Make : As recommended by OEM.
Supply only Hypo. Make : As recommended by OEM.
Labour for Comprehensive maintenance, preventive / periodical, routine and corrective (break down), maintenance, servicing, cleaning, inspection and testing and including replacement of defective components, parts, fittings, sensors, control & power wiring,mechanical drives, doorlock & Laches, drianhose with sensor of Industrial washer extractor and Drying tumblers system Make : M/S Star White (Model No SWE 30), 30 Kg capacity including checking the funtioning of Mechanical Laundry unit, including replacing charges of all spares, Technician and helper visiting charges permonth including transportaion logging boarding and submite the service report and required spareparts for made serviceable all as directed for industrail washing machines comprising the following all as specified and directed :- (i) Industrial Washer Extractor - 02 No of M/S Star White (Model No SWE 30), Capacity of Plant 30 Kg driven by Electric Motor of Capcity - 7.5 HP, 1440 RPM. (ii) Drying Tumbles system - 02 Nos of M/S Star White (Model No STD 30), Capacity of plant 30 Kg, driven by electric motor of capacity of 1 HP - 02 Nos, 935 to 1440 RPM (iii) Flat work ironer with roolers motors,feed conveyar with tray - 2 Nos (iv) Ironing table with aytomatic stam iron electric - 2 Nos (v) Dry and wet trolly and shelf - 6 Nos .
Meterail for Comprehensive , preventive / periodical, routine and corrective (break down), maintenance, servicing, cleaning, testing and including repair and replacement of defective components parts, fittings, sensors, control & power wiring,mechanical drives, doorlock & Laches, drianhose with sensor for all plant and machinereys as mention in item No 7, including checking the funtioning of Mechanical Laundry, worn out parts with new one such as V belt of size B-96, B-98 & B-72 or suitable size of existing plants, assessment, including repairing of 1 & 7 HP three phase 440 volts capacity electric motor of Mechanical Laundry such as rewinding of motor, replacement of defective parts of motor, replacement of bearing, greasing of motor bearing, replacement of PCB, control wiring and canister whees of trolly's, etc and any other parts requird for maintain the serviceability of complete set of plant all as specified and directed
S&F themostatically controlled 2 KW heating element, 230 Volts, ISI marked with rotary ON / OFF switch with light indicator on the site complete.
S&F thermostate for 2 KW heating element, 230 Volts, ISI marked for food warmer complete.
S&F in replacement of 6 Sqmm 3 Core PVC insulated and FR PVC round sheathed, Copper conductor (Flexible) industrial cable, 1100 volt, confirming to IS : 694 incl connection to existing equipment complete.
S&F in replacement of 16 Amp, 3 Pin plug top Heavy duty ISI marked complete.
S&F in replacement of 6 Amp, 3 Pin plug top Heavy duty ISI marked complete.
p.chinnasamy (BID ID -3184276)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .