| Sl No | Description | Qty | Unit | GANGA ELECTRICALS L1 | M/S Ajay Tripathi L2 |
|---|---|---|---|---|---|
| 0.00Construction of 33 KV overhead line and 33 KV UG line for 33/11 KV New Beli Sub station for Mahakumbh Mela 2024-25 | |||||
| 1.00 | Cartage of 13/11 Mtr STP from Store to dump store/work Site Including loading and unloading | 40 | No | 400 ₹16,000 Lowest | 488 ₹19,520 |
| 2.00 | Cartage of 33 KV, 3x300 sq mm XLPE cable from Store to dump store/work Site Including loading and unloading | 6,624 | Mtr | 15 ₹99,360 | 8 ₹52,992 Lowest |
| 3.00 | Cartage of ACSR DOG conductor from Store to dump store/work Site Including loading and unloading | 1 | Km | 2,000 ₹2,000 Lowest | 10,000 ₹10,000 |
| 4.00 | Erection of 13 Mtr. double pole including fixing of necessary clamps, other accessories like M.S. channel, guarding angle, Cross Bracing Angle Set with clamps, disc insulator (B & S type 70 KN) with fitting, 33 KV pin insulator with Pin and Nuts etc. (All Material provided by contractor except ST Pole. | 2 | No | 35,000 ₹70,000 | 28,000 ₹56,000 Lowest |
| 5.00 | Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nuzzling (All required materials {Stay rod 20X1800 mm, Stay wire 10 KG, Stay clamp, Loop Insulator Bolt & nut and grouting material) will be arranged by the contractor) | 10 | Job | 2,000 ₹20,000 Lowest | 2,888 ₹28,880 |
| 6.00 | Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nuzzling (All require materials {Stay rod 16X1800mm, Stay wire 5 KG„ Stay clamp, Loop Insulator Bolt & nut and grouting material )will be arranged by the contractor} | 4 | Job | 2,000 ₹8,000 Lowest | 2,888 ₹11,552 |
| 7.00 | Erection of 13 mtr single support with fixing of necessary 33 KV V type x-arm, 33 Kv Pin Insulator, 33 KV G.I. Pin with nuts, F/E bracket of ST Poles, clamps and other accessories like one no. cross arm, one no. guarding angle, G.I wire for guarding. (as per RESSPO) (All material provided by contractor except 13 M Long ST Pole.) | 8 | No | 9,999 ₹79,992 Lowest | 16,888 ₹1,35,104 |
| 8.00 | Erection of 11 mtr double pole support with fixing of necessary clamps, Cross Bracing angle and other accessories like channel, insulator etc. (As per RESSPO) (All material provided by contractor except 11 M Long ST Pole.) | 14 | No | 9,999 ₹1,39,986 Lowest | 28,000 ₹3,92,000 |
| 9.00 | Grouting of ST Pole, grouting in ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr. with cement sand & bricks Ballast in ratio 1:4:8 and 12 mm thick plastering around the plinth in ration 1:2:4 with 12 mm thickness curing of plinth should be done properly. (as per RESSPO) (All material provided by contractor). | 40 | No | 599 ₹23,960 Lowest | 888 ₹35,520 |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
9 Jun 2023, 2:00 pmClosed
Superintending Engineer
Superintending Engineer, Temp. Maha Kumbh Mela 2024-25, Electricity Circle, Prayagraj
Refer to Tender Description
2023_PVVNV_808309_1
01/TMKM/EC/2023-24
Open Tender
Electrical Works
Lump-sum
180 days
Prayagraj
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
Yes
Account # 50200079575664
₹2.2 L
Yes
22 Jun 2023
2 Jun 2023
9 Jun 2023
2 Jun 2023
9 Jun 2023
2 Jun 2023
Amount
Construction of 33 KV overhead line and 33 KV UG line for 33/11 KV New Beli Sub station for Mahakumbh Mela 2024-25
Cartage of 13/11 Mtr STP from Store to dump store/work Site Including loading and unloading
Cartage of 33 KV, 3x300 sq mm XLPE cable from Store to dump store/work Site Including loading and unloading
Cartage of ACSR DOG conductor from Store to dump store/work Site Including loading and unloading
Erection of 13 Mtr. double pole including fixing of necessary clamps, other accessories like M.S. channel, guarding angle, Cross Bracing Angle Set with clamps, disc insulator (B & S type 70 KN) with fitting, 33 KV pin insulator with Pin and Nuts etc. (All Material provided by contractor except ST Pole.
Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nuzzling (All required materials {Stay rod 20X1800 mm, Stay wire 10 KG, Stay clamp, Loop Insulator Bolt & nut and grouting material) will be arranged by the contractor)
Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nuzzling (All require materials {Stay rod 16X1800mm, Stay wire 5 KG„ Stay clamp, Loop Insulator Bolt & nut and grouting material )will be arranged by the contractor}
Erection of 13 mtr single support with fixing of necessary 33 KV V type x-arm, 33 Kv Pin Insulator, 33 KV G.I. Pin with nuts, F/E bracket of ST Poles, clamps and other accessories like one no. cross arm, one no. guarding angle, G.I wire for guarding. (as per RESSPO) (All material provided by contractor except 13 M Long ST Pole.)
Erection of 11 mtr double pole support with fixing of necessary clamps, Cross Bracing angle and other accessories like channel, insulator etc. (As per RESSPO) (All material provided by contractor except 11 M Long ST Pole.)
Grouting of ST Pole, grouting in ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr. with cement sand & bricks Ballast in ratio 1:4:8 and 12 mm thick plastering around the plinth in ration 1:2:4 with 12 mm thickness curing of plinth should be done properly. (as per RESSPO) (All material provided by contractor).
Earthing of support complete with the help of M.S. rod 20 mm Dia and 2.54 Mtr. long, fastening of G.I. wire with clamps/X-arm/support to M.S. earth rod. As per RESSPO and Electrical safety rules. (All Material Provided by Contractor)
Spreading and stringing of 3 Phase 3 wire continuous conductor for Single circuit 33 KV line including binding of insulator complete in all respect. The work includes jumpering/connecting of conductor at sectional pole (All Material Provided by Contractor except ACSR Dog Conductor)
Spreading and stringing of 3 No. G.I. wire 8 SWG for guarding of 33 KV line and knitting with G.I. wire for making guard at an interval of 5 Meters. The lacing nearest to the support will be about 1.5 Mtr.(All Material Provided by Contractor)
Laying of 33 KV 3x300 sq mm XLPE cable by machine drilling method. The cable shall be laid at the depth of 1050 mm from the surface of road including cartage. The cable shall be laid strictly in compliance to RESSPO Norms.
Laying of 33 KV 3x300 sq mm XLPE cable by manual method. The cable shall be laid at the depth of 1050 mm from the surface with the help of sand, brick & Patiya of road including cartage. The cable shall be laid strictly in compliance to RESSPO Norms. (All required material except 33 KV cable provided by Contractor)
Laying of 33 KV 3x300 sq mm XLPE cable by manual buggi method. The cable shall be laid at the depth of 1050 mm from the surface of road including cartage. The cable shall be laid strictly in compliance to RESSPO Norms. (All required material except 33 KV provided by Contractor)
Drilling in all horizontally to cross the road/parallel to road, 1050 mm bellow from the surface for laying of HDPE Pipe and laying of 33 KV.3x300 sq m.m XLPE cable in 8'' dia HDPE Pipe including cartage. (All material proved by Contractor as HDPE Pipe except 33 KV Cable )
Drilling in all horizontally to cross the Railway Track, 4000 mm to 5000 mm bellow from the surface for laying of HDPE Pipe and laying of double 33 KV.3x300 sq m.m XLPE cable in 8'' dia HDPE Pipe including cartage. (All material proved by Contractor as HDPE Pipe except 33 KV Cable )
Fixing of H.S. type cable joints & end terminations suitable for 33 KV, 3x300 sq mm XLPE cable conforming to IS-15573 of 1992, VDE-0278, ESI-0913 & 7098 (All Jointing kit provided by contractor.
Outdoor/indoor jointing kit (Make Weasel/Raychem/3M)
Straight through jointing kit (Make Weasel/Raychem/3M)
Hoisting of 33 KV 3x300 sq mm XLPE cable providing GI pipe of size 6” dia 3 M long on double pole including its jumpering, complete with Channel and clamps, nut & bolts. As per RESSPO and Electrical safety rules. (All material provided by contractor except cable)
Dismantling of 33 kv /11 kv and L.T. over head line including poles conductor channel and clamps etc and carriage of material from site to Naini store.
Cutting of tree branches all along the route of 33 KV Line, which may obstruct the line.
Small branches.
Big Branches.
Painting of 11/13 ST Pole with Clamp and Channel 2 coat Red Oxide and 2 coat Aluminum Paint
Installation of Sign board at site after complition of work. Sign board size 3x4 feet with stand. (Writing material and sign board design will be provided by department and Sign Board, Stand and Grouting materials provided by contractor, Sing board will be provided by contractor as per sample provided by department.)
Photo and Videography before and after the work will be provided by the contractor in soft & hard colour copy (size 8x10" album) and soft copy video in minimum 1080 P quality in Pen drive in 3 set.
Restoration Charges of existing utilities
Telephone, Water Pipe Line, Sever Line etc.
LT/HT Line
M/S Ajay Tripathi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .