| 1 | L1₹33.1 LAccepted-AOC NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.1 L+₹1.7 L (5.03%)Rejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹42.0 L+₹7.6 L (22.0%)Rejected-Finance HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Utilities) Udhampur
GE (Utilities) Udhampur, PO- Garhi, Pin-182121
Repair/Maint of Summer Appliances along with allied work in AOR of RAC section under GE (Utilities) Udhampur
2025_MES_712530_1
GE/U-31/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹96,000
22 Jul 2025
4 Jun 2025
4 Jul 2025
4 Jun 2025
2 Jul 2025
18 Jun 2025
Amount
M&L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manufacturer with high pressure pump of 1.0/1.5/2.0 ton capacity,complete all as specified and directed by Engr-in-Charge.
M & L for cutting of suction line and discharge line tubing of AC, de-scaling of front scaled unit flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.0/1.5/2.0 ton Split/W/T type AC, complete all as specified and directed by Engr-in-Charge.
M&L for detection/rectification of leakage of gas by vacume the system, charging with Nitrogen gas and vacume the system after detaction of lekage and gas charging in the system with appropriate quantity of gas as per OEM Recomentation including testing for smooth functioning of Split type/ Window type AC of capacity 1.0/1.5/2.0 Ton, complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-22 in Split/Window air conditioner,of capacity 1.5/ 2 TR, complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-32 in Split/Window air conditioner of capacity 1.5/ 2 TR, complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-410A in Split air conditioner of capacity 1.5/ 2 TR, complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-600A in refrigerantor, complete all as specified and directed by Engr-in-Charge.
Supply only Butane Gas suitable for torch, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new indoor unit of split AC of capacity 1.5 ton with compitable for existing out door unit from authorized dealers of company, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new indoor unit of split AC of capacity 2.0 ton with compitable for existing out door unit from authorized dealers of company, complete all as specified and directed by Engr-in-Charge.
S&F in outer unit frame/stand sutable for 2.0 TR split ac outdooer unit inclding grouting nut, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new universal PCB with remote and display, complete all as specified and directed by Engr-in-Charge.
Repair/replacement PCB for any make and model window/Split type AC 1.5 ton / 2Ton, capacity complete all as directed by Engr-in- charge .
Repair/replacement inverter technology PCB complete with indoor /outdoor unit and sensor for any make and model split type AC 1.5ton/2Ton cap, complete all as directed by Engr-in- charge .
Supply and fix in replacement coil senser of existing shape and size suitable for 1.5/2 Ton Split Type AC, complete all as specified and directed by Engr –in – charge.
Supply and fix in replacement heating senser of existing shape and size suitable for 1.5/2 Ton Split Type AC, complete all as specified and directed by Engr –in – charge.
Supply & fixing in replacement of thimble brass suitable for all type of AC,Water cooler, Referigerator,Deep freezer in pkt, complete all as specified and directed by Engr-in- charge.
S&F in replacement blower motor of Split type AC 1.5/2.0 Ton of existing make & model, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement blower(plastic body) of 1.5/2.0 Ton Split/Window type AC, complete all as specified and directed by Engr-in- charge.
Supply and fix in replacement cooling coil of existing shape and size suitable for 1.5/2 Ton Split/Window type AC , complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement condenser coil of existing shape and size suitable for 1.5/2Ton Split/Window type AC, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement & testing of Fan Motor of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motor of capacity 1/8 HP double shaft for 1.5 /2.0 Ton window type AC including base, frame, side clamps complete in all respect, complete all as specified and directed by Engr-in-Charge.
Description all as per Srl item No 22.00 above here-in-before but Fan motor 1/7 HP of split type AC any make & model complete with base, frame, clamps, side holders, rubber bushes with main lead suitable for Voltas/ LG, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement front show grill for LG/Voltas /Sidwal/Godrej window type AC 1.5 Ton, complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unsv Reverse cycle valve for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing, complete all as specified and directed by Engr –in –charge.
Supply & fixing flexible drain pipe for Window type/Split Type AC with clamp of any capacity complete all as specified and directed by Engr-in- charge.
Supply and fix in replacement swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new outdoor unit inverter model with all accessories, without Compressor for split AC of capacity 1.5 ton from authorized dealers of company, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new outdoor unit with inverter model all accessories, without Compressor for split AC of capacity 2.0 ton from authorized dealers of company, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Fan Blade of 1.5/2 ton window type AC of any capacity, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement Fan Blade of 1.5/2 ton split type AC of any capacity, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement discharge valve of 1.5/2 ton split type AC of any capacity, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement suction valve of 1.5/2 ton split type AC of any capacity, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement bush of 1.5/2 ton split type AC .of any capacity makle LG/ Voltas, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement capillary of 1.5/2 ton split type /window type AC .of any capacity, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement dead nut of 1.5/2 ton split type /window type AC .of any capacity, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement NRV of 1.5/2 ton split type /window type AC .of any capacity, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement of unserviceable remote control unit Suitable for 1.5 / 2.0 Ton split/window type AC, complete all as specified and directed by Engr-in- charge.
Supply & fix in replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump, complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable foam insulation and supply and fix new foam insulation with white taping fixing with clamp of 1.5 / 2 ton split type /window type AC of any capacity, complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)
S&F in replacement new rotary type AC compressor of existing split type/window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton, complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No.41.00 here-in-before but of size 2.0 ton capacity, complete all as specified and directed by Engr-in-Charge.
S&F in replacement new Reciprocating type AC compressor of existing split type /window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton, complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No.43.00 here-in-before but of size 2.0 ton capacity, complete all as specified and directed by Engr-in-Charge.
Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement metal plug and socket board complete enclosure with single pole & neutral and earth plug with MCB SP 32/40 Amps, 220 Volts, complete all as specified and directed by Engr-in- charge.
Supply and fix in replacement Sheet Metal Enclosure with DBs single pole and neutral 2 Way, 240 volts, complete all as specified and directed by Engr-in- charge.
Supply and fixing in replacement MCB SPN 32 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCB SP 20 to 32 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engr-in-Charge.
S&F in replacement Sub main wiring with two single core PVC insulated FRLS unsheathed copper conductor multistranded cable 1100 volts grade 6 sqmm size in PVC Conduit heavy duty ISI marked with 6sqmm PVC insulated FRLS copper coductor multistranded cable as earth lead to connecting to earth dolly, complete all as specified and directed by Engr-in-Charge.
S&F in replacement Wiring for connection between outer and inner unit of split AC with four single core PVC insulated FRLS unsheathed copper conductor multistranded cable 1100 volts grade 2.5sqmm size in PVC conduit heavy duty ISI marked with 2.5 sqmm PVC insulated FRLS copper conductor multistranded cable as earth lead/single to connecting to earth dolly, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement water tap internal threaded /external threaded suitable for water cooler, complete all as specified and directed by Engr-in - Charge.
Supply and Fix in replacement Fan motor1/20 HP single shaft for water cooler as per the original make of, complete fan motorcomplete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement Fan motor1/35 HP single shaft for water cooler as per the original make of, complete fan motorcomplete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement Fan motor1/70 HP single shaft for water cooler as per the original make of, complete fan motorcomplete all as specified and directed by Engr-in-Charge.
S&F compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler, complete all as specified and directed by Engr-in-Charge.
S&F compressor reciprocating type (hermetically) sealed for capacity 60/120 litre water cooler, complete all as specified and directed by Engr-in-Charge.
S&F compressor reciprocating type (hermetically) sealed for capacity 150 litre water cooler, complete all as specified and directed by Engr-in-Charge.
Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance, complete all as specified and directed by Engr-in-Charge.
Replacement of 'T' junction for desert cooler for watering the three side of the desert cooler with nozzels, complete all as specified and directed by Engr-in-Charge.
Replacement of Khas khas set for the doors of desert coolers for different size and make, complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement overload/PTC relay for water cooler ,Deep freezer and referigerator supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigerator satisfactory performance commissioning, complete all as specified and directed by Engr-in-Charge.
Supply & fixing flexible drain pipe for Water Cooler of any capacity any size, complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable spare parts from air curtain such as Air Curtain motor, Air curtain door sensor, Air curtain blower, blower wheels replacement with new and fix of any capacity or siz,e complete all as specified and directed by Engr -in- Charge (as per sample approved by GE).
M&L for repair /repalcement of broken /water leakage from connection of water cooler of capacity 40/80ltr to 150/150ltrs capcity by dismatiling the front sheet of the water cooler tank, removing the thermocol sheet and doing necessary cutting /welding /brazing work to stop the leakage and make good the damaged portion and fixing of tap connection and reassembling the front sheet including provinding the thermocol as a thermal insulation to the water coolers and testing the coolers for no leakage as, complete all as specified and directed by Engr- in- Charge.
Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA,5KVA,2KVA,1KVA,0.5KVA thoroughly checking,cleaning all parts by brushing and assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair / replacement of components as below, complete all as specified and directed by Engr-in-Charge:-
M&L rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA, complete all as specified and directed by Engr-in-Charge.
Description all as per ser item No.67.00 here-in-before but of capacity 5KVA, complete all as specified and directed by Engr-in-Charge.
M&L in replacement of relay for 7.5KVA & 5KVA,30amp 24volts DC, complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Step down transformer 24 volts 2Amp for 7.5 KVA & 5KVA, complete all as specified and directed by Engr-in-Charge.
M&L in replacement of plug top 15 Amp, complete all as specified and directed by Engr-in-Charge.
M&L for Refrigerator/deep freezer of any make and capacity finding the leakage /damage portion. Rectify the leakage and damaged parts and vaccume leakage the whole system. Then charging the refrigerent Gas and confroming no leakage . The reassembling the same deep freezer by provinding proper insulation material at the disturbed area all as per entire satisfaction of Engineer-in- Charge, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Fan motor with fan suitable for any make & model refrigerator 286ltr / 310 Ltr, complete all as specified and directed by Engr-in-Charge.
Description all as per Srl item No 73.00 above here-in-before but suitable for 165 to 195 litre Refrigerator, complete all as specified and directed by Engr-in- Charge .
Description all as per Srl item No 73.00 above here-in-before but suitable for 320 litre Deep freezer, complete all as specified and directed by Engr-in- Charge .
Taking out old unserviceable Condensing coil for 165/170 to 310 Litre Referigerator and supply and fix new condenser coil of existing make shape and size, complete all as specified and directed by Engr-in-Charge.
Supply and fix new thermostate for Refrigerator/Deep freezer of any capacity any make, complete all as specified and directed by Engr –in- charge.
S&F in replecement new sealed compressor suitable for Deep Freezer of single phase, 230 Volt, 50 Hz of Deep Freezer of any Size in and including refrigerant gas filling up to required level, complete all as specified and directed by Engr-in-Charge.
S&F in replecement new sealed compressor of suitable for Refrigerator of single phase, 230 Volt, 50 Hz of Refigerator of any Size in and including refrigerant gas filling up to required level, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Cabin Display of lift , make as per sample, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Landing circuit Unit ((LOP/LCU) of lift, make as per sample, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Capacitor of capacity 50+6 mfd for window /split type AC, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement Capacitor of capacity 45+5 mfd for window /split type AC, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement Capacitor of capacity 80+100 mfd for water cooler, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement Capacitor of capacity 10 mfd for water cooler, complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement diffrerent make and size shelf of refrigerator, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of dran water motor for split/window AC, complete all as specified and directed by Engr-in-Charge.
Servicing of Pillar AC 1.5/2 Ton carried out by cleaning, greasing and oiling from authorised rep of Service Engineer of manufacturer.
M/S M P Construction Co (BID ID -3336760)
slathia construction works (BID ID -3336444)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .