Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹49.5 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹52.2 L+₹96,540 (1.89%)Rejected-AOC | 2 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
31 Jan 2020, 6:00 pmClosed
GE SATWARI
GE SATWARI
REPAIR/MAINTENANCE TO CENTRAL AC PLANT, ACs AND REPAIR/REPLACEMENT OF WATER SUPPLY PIPE LINE UNDER GE SATWARI
2019_MES_306327_2
GEJM-73/19-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE SATWARI
₹1 L
Yes
1 May 2020
24 Jan 2020
3 Feb 2020
24 Jan 2020
31 Jan 2020
25 Jan 2020
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,cables,pipe line,pole etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out, in any type of soil, complete all as specified and as directed by Engineer-In-Charge.
Returning filling in, trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified.
Removing excavated surplus materials to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. Note for item No 1 to 3 :- During the excavation any damage to the existing services like telephone cable,electric cable, sewage line etc will be repaired by the contractor at his own risk & cost. No extra payment will be born by the dept. on this account.
Taking out unservicable GI/CI/DI/MS tubing 20 /25/40/50 mm bore from the trenches/over ground Complete with fittings as directed by Engr-in-Charge
Description all as per srl item No 4 here in before but for 80/100/150/200 mm bore pipe.
Supplying,laying,jointing & testing in replacement of galvanised steel tubing 15 mm bore medium grade with screwed /flanged joint together with all fitting such as bends, elbows,tees,short pieces and union etc laid in trenches complete all as specified and directed
Description all as per Srl item No 6 here in before but for 20mm bore pipe.
Description all as per Srl item No 6 here in before but for 25mm bore pipe.
Description all as per Srl item No 6 here in before but for 40mm bore pipe.
Description all as per Srl item No 6 here in before but for 50mm bore pipe.
Description all as per Srl item No 6 here in before but for 80mm bore pipe.
Description all as per Srl item No 6 here in before but for 100mm bore pipe.
Description all as per Srl item No 6 here in before but for 150mm bore pipe.
Supply Fixing & Laying in trenches,, jointing and testing in replacement of Ductile Iron pipe with socket & spigot end of bore 200 mm specials Class K-9 suitable for tyton joint including jointing material/joints complete as specified and directed.
Description all as per Srl item No 14 here in before but for 150 mm bore pipe.
Description all as per Srl item No 14 here in before but for 100mm bore pipe.
M & L for welding the existing leakage GI /MS/DI Pipe line any size laid in trenches / along with overhead in vertical position by using electric welding machine & welding electrode complete all as directed by Engr-in-charge.Note :Earth work shall be measured and paid separately under respective item of shedule
Supply and fixing in replacement of cast iron body sluice valve heavy duty class PN 1.6 flanged ends any pattern with cast iron wheel & mild steel spindle ISI marked confirming to IS-14846 of 2000 for 50 mm bore pipe with jointing material ,flanged joint,rubber gasket 6mm thick, nuts & bolts, washer complete all as specified and directed.
Description all as per Srl item No 18 here in before but 80 mm bore pipe
Description all as per Srl item No 18 here in before but 100mm bore pipe
Description all as per Srl item No 18 here in before but 150mm bore pipe
Description all as per Srl item No 18 here in before but 200 mm bore pipe
Supply and fixing in replacement of Gun matel gate /globe valve , screwed both ends for iron pipe of 15 mm bore ISI marked all as specified and directed.
Description all as per Srl item No 23 here in before but 20 mm bore pipe
Description all as per Srl item No 23 here in before but 25 mm bore pipe
Description all as per Srl item No 23 here in before but 40 mm bore pipe
Description all as per Srl item No 23 here in before but 50 mm bore pipe
Supply and fixing in replacement of cast copper alloy bib Tap , for iron pipe of 15 mm bore ISI marked all as specified and directed.
Description all as per Srl item No 28 here in before but 20 mm bore pipe
Burning out old leaking lead joints in position and removing old lead from 80mm bore CI pipe/ fittings and keeping aside for further disposal (earth work shall be measured and paid separately).
Description all as per Srl item No 30 here in before but for 100mm bore pipe.
Description all as per Srl item No 30 here in before but for 150mm bore pipe.
Description all as per Srl item No 30 here in before but for 200 mm bore pipe.
Material and labour for run lead joint including all jointing material such as lead, spun yarn etc for 80mm bore cast iron spigot & socketed pipe & fittings. (Exc earth work will be measured & paid for separetely.
All as per item No 34 here in before but for 100mm bore cast iron spigot & socketed pipe & fittings.
All as per item No 34 here in before but for 150mm bore cast iron spigot & socketed pipe & fittings.
All as per item No 34 here in before but for 200 mm bore cast iron spigot & socketed pipe & fittings.
Drilling and tapping (15mm to 25mm dia) in existing 150mm/100mm/80mm bore GI/CI pipe line for taking branch connections including providing brass ferule (15mm to 25mm dia) & required fitting (excavation and earth work will be measured & paid for separetly) complete all as specified and directed.
Cutting of existing cast iron pipe line of 150 mm bore in position for inserting of CI Special such as tees,bend,coller,tail piece etc for fixing of sluice valves/for branch connection etc. Note:- Exc & earth work,CI Special & sluice valves of size & lead joint shall be measured and paid separately under respective item of shedule 'A'.
Description all as per Srl item No 39 here in before but size of pipe 100mm/80mm bore.
Dismentaling broken valve pit chamber and Material and labour in replacement of construction of brick masonary valve pit built in cement mortar 1:6 of size 120cm x 120cm x110cm (internal dimension) over 15cm thick PCC 1:3:6 type C-2 sub base extended alround 15cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:4 internally and plus pointing to brick wall surfaces externally as work proceeds complete with MS sheet cover 3.15 mm thick with handle and locking arrangement, angle iron frame 40mm x 40mm x 6mm (grouting with anchor fastenore length not less than 15cm - 04 Nos) and painting with a coat of synthatic enamel paint over a coat of red oxide, complete all as specified and directed.
Description all as per Srl item No 41 here in before but of size 100cm x 100cm x 100cm (internal dimension).
Material and labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate for supporting of CI/GI pipes,header etc all as specified and directed.
Supply and fixng in replacement Cast iron Non return valve (NRV) 150 mm bore complete conforming to IS 1969 double flanged and drilled including bolts, nuts, washers, gasket etc complete and dismantling of old one complete all as specified and directed. make : SIR/VENUS/ SANT
Supply only Altoc GP ( Calcium based granullar disinfectant for water treatment) in platsic drum packing of 45 KG all as specified and directed. Make: Declibac Technologies Pvt Ltd/ Pearl
Material and labour for tyton joint for DI Pipe line including all jointing material of size 100 mm bore complete as directed by Engr-in-Charge (Exc earth work will be measured & paid for separetely.
Description all as per Srl item No 46 here in before but size of pipe 150 mm bore.
Supply and fix in replacement of GI union ISI marked of 15 mm bore all as specified and directed.
Supply and fix in replacement of GI union ISI marked of 20 mm bore all as specified and directed.
Supply and fix in replacement of GI union ISI marked of 25 mm bore all as specified and directed.
Supply and fix in replacement of GI union ISI marked of 40 mm bore all as specified and directed.
Supply and fix in replacement of GI union ISI marked of 50 mm bore all as specified and directed.
Supply and fix in replacement of GI elbow ISI marked of 15 mm bore all as specified and directed.
Supply and fix in replacement of GI elbow ISI marked of 20 mm bore all as specified and directed.
Supply and fix in replacement of GI elbow ISI marked of 25 mm bore all as specified and directed.
Supply and fix in replacement of GI elbow ISI marked of 40 mm bore all as specified and directed.
Supply and fix in replacement of GI elbow ISI marked of 50 mm bore all as specified and directed.
Supply and fix in replacement of GI nipple 15 mm bore ISI Marked any length all as specified and directed.
Supply and fix in replacement of GI nipple 20 mm bore ISI Marked any length all as specified and directed.
Supply and fix in replacement of GI nipple 25 mm bore ISI Marked any length all as specified and directed.
Supply and fix in replacement of GI nipple 40 mm bore ISI Marked any length all as specified and directed.
Supply and fix in replacement of GI nipple 50 mm bore ISI Marked any length all as specified and directed.
Supply and fix in replacement of GI socket 15 mm bore ISI marked all as specified and directed.
Supply and fix in replacement of GI socket 20 mm bore ISI marked all as specified and directed.
Supply and fix in replacement of GI socket 25 mm bore ISI marked all as specified and directed.
Supply and fix in replacement of GI socket 40 mm bore ISI marked all as specified and directed.
Supply and fix in replacement of GI socket 50 mm bore ISI marked all as specified and directed.
Supply and fixing in replacement Rubber gasket joint 3 mm thick with 4/6 hole for flanged joint 80 mm dia complete all as specified and directed.
Supply and fixing in replacement Rubber gasket joint 3 mm thick for flanged joint 100 mm dia complete all as specified and directed.
Supply and fixing in replacement Rubber gasket joint 3 mm thick for flanged joint 150 mm dia complete all as specified and directed.
Material and labour for replacement of Contactor 3 pole with coil voltage 220 volt type MNX 70 rating in automatic starter suitable for 40/50 HP. Make: L&T / C&S/ Indoasian
Material and labour for replacement of Contactor 3 pole with coil voltage 220 volt type MNX 110 rating in automatic starter suitable for 40/ 50 HP. Make: L&T / C&S/ Indoasian
Painting of the pipe line any size in pump house building in side or out side/ along with over head tank by removing old paint, cleaning the surface removing all dust and oil from the surfaces with two coat of synthetic enamel paint with spray paint as per existing colour and writing the direction and supplying area in capital letters as directed by Engr-in-Charge
Painting of the pump Sets,voltage stablizer etc by removing old paint, cleaning the surface removing all dust and oil from the surfaces with two coat of synthetic enamel paint with spray paint as per existing colour as directed by Engr-in-Charge
Material and labour for opening of top cover of sluice valve any size and replacement of Gland packing of sluice valve including nut bolt washer of existing size complete all as specified and directed.
Disconnecting the electrical connection for taking out unserviceable / BER equipment like DG set,Servo Voltage stablizer, LT panel Chloronation Plant etc, shifted from installation to MES store yard as directed by Engr-in Charge The cost of transportation is deemed to be included in the quoted rate.
Supply and fix in replacement of Rotor assembly with bearings brachets & tollerence rings of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Coil 250V 50 HZ of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Single head feed rate control with shaft of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Pump head (Ferrule 1/4" & Duckbill included) of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Roller assembly of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Pump tube of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Injection check valve of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Weighted suction line stainer of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of 3/8" white suction/discharge tubing of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Check valve duckbill of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Connecting nut 3/8" with adapter of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Connecting nut 3/8" of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Ferrule 1/4" of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Injection valve up to 7 Kg pressure for dosing pump of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of Foot valve for dosing unit of Decrine dosing pump of make : Declibac modal No-96NGQ51
Supply and fix in replacement of 25mm bore ball valve of Decrine dosing pump of make : Declibac modal No-96NGQ5
Supply and fix in replacement of PVC diaphram for dosing pump of Decrine dosing pump of make : Declibac modal No-96NGQ5
Supply and fix in replacement of PVC head for dosing pump of Decrine dosing pump of make : Declibac modal No-96NGQ5
Supply and fix in replacement of 'O' ring for PVC head for dosing pump of Decrine dosing pump of make : Declibac modal No-96NGQ5
Material and labour for Cast iron fitting for CI spigot socketed/ flanged pipe bend (any type radius and angle) tapers any type (straight, bends increasing, decreasing or double socket etc) tee pieces, single branch 'Y' junction double branch cross (all socket or socket spigot or flanged) collars, cap and plugs upto 200 mm bore connection pieces one end flanged and other socket or spigot and bell mouth piece one end flanged and other end tapering as bell mouth complete all as specified and directed.
Supply and fix in replacement of Walk-in-cooler (Chiller Room Refrigeration unit) having refrigeration capacity: 20000 Btu/Hr @ +2oC Room temerature & 45o C ambient temperature, Compressor: CR-30 Emersion three phase (Hermetic type) cubical Wall/ Slim Roof mounted Evaporator-SS(304) body high CFM evaporator Refrigerant: R-22, Condensing medium: Air cooled, along with elctrical control panel AC 3 phase 415 volts complete all as specified & directed.
M&L for replacement of nozzle set of sprinkler for existing cooling tower cap 200 TR and testing all as specified and directed.
Material and labour for replacement of suction pressure transducer in suction pipe of compressor of central AC plant of 190 TR capacity complete all as specified and directed. Note: The work shall be carried out by the authorized representative of OEM.
Material and labour for replacement of discharge pressure transducer in discharge line of compressor of central AC plant 190 TR capacity complete all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Material and labour for replacement of high pressure switch of central AC plant 190 TR capacity completion all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Material and labour for replacement of suction pressure transducer in suction pipe of compressor of central AC plant 90 TR capacity by pumping down/recovering of refrigerant gas from the compressor, fixing of HP switch charging recovered refrigerant gas and testing on completion all as specified and directed. Note: The work shall be carried out by the authorized representative of OEM.
Material and labour for replacement of high pressure switch in discharge pipe of compressor of central AC plant of 90 TR capacity by pumping down/recovering of refrigerant gas from the compressor and testing on completion all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Material and labour for trouble shooting/fault detection in case of major break down of the AC plant 3x90 TR from the authorized person/company representative of the Voltas for the smooth functioning and servicing of the plant as well as for un interrupted running. The job includes step by step check up of the plant with proper diagram and replacing of the burnt or unsv parts if any like resistors or counters or timers or repair to electronic circuit board etc.
Material and labour for trouble shooting/fault detection in case of major break down of the AC plant 2X26 TR from the authorized person/company representative of the Blue star for the smooth functioning and servicing of the plant as well as for un interrupted running. The job includes step by step check up of the plant with proper diagram and replacing of the burnt or unsv parts if any like resistors or counters or timers or repair to electronic circuit board etc.
Material and labour for charging refrigerant gas R 134 A in the compressor system after detecting any leakage, rectifying the leakage in the system, proper evacuation and pressure testing with Nitrogen gas for the desired pressure and testing on completion all as specified and directed. Note : The work shall be carried out by the representative of OEM
M&L for cutting, dismantling of existing MS pipe line with insulation and proving new MS pipe line 25 mm bore heavy duty for making connection to the existing AHU inlet and out let pipe line with cutting, including necessary fitting and welding complete all as specified and directed. make: Jindal/tata steel/ Praksh Surya.
Material and Labour for providing insulation of MS pipe with PUF slab 30 mm thick with and including applying bituminious compound and aluminium cladding with 26 gauge aluminium sheet complete for MS pipe of 25 mm bore, complete all as specified and directed.
Supply and fix Non return butterfly valves, ISI marked screwed both ends for iron pipe of 25 mm dia PN-10 with union complete all as specified and directed.
Supply and fix butterfly valves, ISI marked screwed both ends for iron pipe of 62 mm dia PN-10 with union complete all as specified and directed.
Taking down and removing the Old unsv PVC Files from cooling tower of cap 26 TR.and clean the cooling tower by jet pump with suitable chemical.
Material and Labour for replacement of complete PVC files of cooling tower, of cap 26 TR of with taking out PVC files and making the cooling tower functional all as specified and directed.
Material and Labour for replacement of Tie rod set and Buckle which hold the exisiting fan blade coupled with sprinkler set of 26TR AC Plant complete all as specified and directed.
Disconnecting of electric connection of compressor 95TR from chiller unit of capacity 190 TR by removing & recovery of Refrigerant gas in the cylinder, recovery of compressor oil, unscrewing & taking out of saeled of screw compressor with help of chain pulley block and refixing the same after after repair in original position complete all as specified and directed. Note: 1. Any repair/overhauling in compressor unit shall be measured and paid under relevent item. 2. If any damage to compressor during poor handling/hoisting/lifting, the same will be rectified by contractor without any extra cost.
M&L for overhauling of compressor 95 TR capacity by carrying out extensive electrical and mechanical repairs like replacement of all existing bearings, refitting of existing starter into body shell and necessary connection and testing on complition complete all as specified and directed. Note: Any minor items like nut volt or replacement of other unsv minor part required while overhauling of compressor are included in quoted rate.
Material and Labour for replacement of unsv internal oil filter suitable for screw compressor of chiller unit 190 TR make: carrier model: 30HXC190A, complete all as specified and directed.
Material and labour for replacement of compressor oil approved by OEM suitable for carrier Make compressor complete all as specified and directed.
M&L for repair of chiller/condensor of chiller unit 190 TR make: Carrier Model: 30HXC190A detecting leakage in the system and rectify the leakage in the chiller/condensor of system, flushing the system of any rust and dirt with antirust chemicals, nitrogen pressure testing of chiller & condensor and assembling the system and testing complete.
Supply & fix in replacement of variable frequency drive suitable for centrifugal pump set of capacity 20 HP, 3 phase, 440 Volt, and necessary electrical connection of make: ABB cat No. ACS-310 or its equivalent in L&T/schnieder all as specified and directed.
Disconnecting of electric connection of compressor 13 TR from chiller unit of capacity 26 TR by removing & recovery of Refrigerant gas in the cylinder, recovery of compressor oil, unscrewing & taking out of saeled of scroll compressor with help of chain pulley block and refixing the same after repair in original position complete all as specified and directed. Note: 1. Any repair/overhauling in compressor unit shall be measured and paid under relevent item. 2. If any damage to compressor during poor handling/hoisting/lifting, the same will be rectified by contractor without any extra cost.
M&L for overhauling of compressor 13 TR capacity by carrying out extensive electrical and mechanical repairs, refitting of existing starter into body shell and necessary connection and testing on complition complete all as specified and directed. Note: Any minor items like nut volt or replacement of other unsv minor part required while overhauling of compressor are included in quoted rate.
M&L for repair of chiller/condensor of chiller unit 26 TR make: Blue star detecting leakage in the system and rectify the leakage in the chiller/condensor of system, flushing the system of any rust and dirt with antirust chemicals, nitrogen pressure testing of chiller & condensor and assembling the system and testing complete.
Material and labour for replacement of drier filter suitable for Blue star Make compressor of capacity 26 TR complete all as specified and directed.
Supply & fix in replacement of temperature sensor in 95 TR chillar unit of 190 TR AC Plant complete all as specified and directed.
Supply & fix in replacement of SCPM card in condensor of 90 TR AC Plant complete all as specified and directed.
Supply & fix in replacement of SCPM card in condensor for 95 TR of 3X190 TR AC Plant complete all as specified and directed.
Supply & fix in replacement of SCPM card in condensor of 26 TR AC Plant complete all as specified and directed.
Material and Labour for replacement of DIN type HRC fuse (with ISI marks) of capacity 325 Amp complete all as specified and directed.
M&L for packing of existing opening like window by thermocoal of thickness 150 mm minimum and wooden ply of thickeness 10-12 mm by suitable fixing arrangement incl coating of thermic insulation providing insulation of ply wood with PUF slab 30 mm thick with and including applying bituminious compound and aluminium cladding with 26 gauge aluminium sheet complete all as specified and directed.
Material and Labour for providing insulation of MS pipe with PUF slab 40 mm thick with and including applying bituminious compound and GI cladding with 26 gauge GI sheet complete for MS pipe of 150 mm bore, complete all as specified and directed.
Supply and fix in replacement of rotational moulded polyethyline water tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 5000 Ltrs complete incl necessary plumbing wk all as specified and directed.
S&F in replacement Material and Labour for providing insulation of MS pipe with PUF slab 40 mm thick with and including applying bituminious compound and GI cladding with 26 gauge GI sheet complete for MS pipe of 150 mm bore, complete all as specified and directed.
M&L for cutting of existing MS pipe and supply and fixed Non return butterfly valves 32 mm dia in condensor pipe line of 2 X 26 TR AC Plant complete all as specified and directed.
Supply and fix in replacement of gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete of size 20 mm all as specified and directed.
Material and Labour for replacement of DIN type HRC fuse links (with ISI marks) of capacity 125 Amp complete all as specified and directed.
Material and Labour for replacement of current transformer of cap 150/5 Amp, 5 VA, Class-1.0, Make Larson Electrical Engineers or its equivalent complete all as specified and directed.
Material and Labour for replacement of contactor MNX A-2 complete all as specified and directed.
S&F in replacement MCB of cap 06-32Amp, single pole, 'C' series complete all as specified and directed. Make: Schineder or its equivalent
S&F in replacement of single phase preventer complete all as specified and directed. Make: Schineder or its equivalent
S&F in replacement MCB three pole of cap 25 Amp, 'C' series complete all as specified and directed. Make: Schineder or its equivalent
S&F in replacement of push botton starter/stop assembly complete all as specified and directed. Make: Schineder or its equivalent
S&F in replacement three phase Ameter digital type of size 96 X 96 mm of cap 0-20 Amp with suitable CTs ratio complete all as specified and directed. Make:AE or its equivalent
S&F in replacement threephase Ameter digital type of size 96 X 96 mm of cap 0-100 Amp with suitable CTs ratio complete all as specified and directed. Make:AE or its equivalent
S&F in replacement of pressure gauge analog type of measuring cap upto 150 Psi complete all as specified and directed.
S&F multifunction digital thermometer up to 50oC with backlight with USB interface incl ISO calibration certificate all as specified and directed. Make: R Tek or its equivalent.
S&F in replacement MCCB 4 pole of capacity 400 Amp AC 415 Volts Confirms to IS/IEC 60947-2, Breaking capacity 36 KA, positive isolation, thermal magnetic release, adjustable overload 80-100%, adjustable short circuit 5-10 In make C&S Cat No: CSCN400TM*4P or its equivalent in Legrand, Hegar, ABB all as specified and directed.
Redevelopment of tube well with air compressor of adequate capacity (not less than 250 cfm) till the availability of sand free clear water,subject to minimum 24 hrs of operation of air compressor. (Rate shall include transportation,fitting ,jointing and drainage of adequate size of air compressor as specified and directed. )
M/S S K Electricals Regd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .