| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹18.6 L+₹27,463.20 (1.50%)Rejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC OK | |
| 3 | L3₹19.3 L+₹1.0 L (5.59%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC OK | |
| 4 | L4₹21.3 L+₹3.0 L (16.5%)Rejected-AOC | L4 | Rejected-AOC OK | |
| 5 | L5₹23.1 L+₹4.8 L (26.3%)Rejected-AOC WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC OK |
Tender Value
₹29.9 L
EMD Value
₹59,900
Closing Date
9 Jul 2024, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
REPAIR AND MAINT OF PIPELINES EXTERNAL WATER SUPPLY PUMP MOTORS STARTERS DOZERS ETC AND OTHER CONNECTED WORKS AT JINDRAH UNDER GE ARMY DHAR ROAD
2024_MES_659128_1
8070/NIT-44/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹59,900
Yes
24 Sept 2024
11 Jun 2024
11 Jul 2024
12 Jun 2024
9 Jul 2024
26 Jun 2024
Amount
Excavation in trenches in soft/loose soil not exc 1.5 mtr wide and not exc 1.5mtr depth and getting out for taking out CI Pipe lines, taking out/laying of CI/GI pipe lines forming bottom surfaces of excavtion to re-wired lines/gradient etc complete all as specified.
Returnning, filling in, intrenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified & directed.
Removing surplus spoil to a distance not exc 50 mtr away and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 30 cm in depth for passing of pipe line and making good of disturbed surface to match with the existing surfaces by using new material i.e bitumen, aggregate complete incl compaction of cutting portion and making good all as specified and directed
Taking out GI water tubing lines and connected unserviceable pipe and fitting includidng segregation of serviceable pipe and fittings and keep in safe custody and reuse serviceable pipe line and fitting from tranch/ in ground/under road /under PCC path etc the site of work complete all as specified and as directed of the following bore size :-
150 mm dia
100 mm dia
80 mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Relaying/ refixing of old serviceable GI pipe and connection as obtained from item No 5 here-in-before with running GI fittings cleaning of pipe internally and externally comple all as specified and directed of the following bore sizes :- Note : New fitting (Medium grade) shall be provided
150 mm dia
100 mm dia
80 mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
M&L for GI water tubing medium grade and laid in trenches/floors/walls with running fittings complete all as specified and directed of following sizes :-
150 mm dia
100 mm dia
80 mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and as directed to following bore of size including dismantling of old GM gate valve.
80 mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Re-fixing old serviceable gate valve in any loc of any make including dismantling of serviceable ones all as directed by Engineer-in-charge of following size :-
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
M&L construction of brick masonery valve pits of size 600x600x600 mm internal dimension with brick work in cement mortar (1:4) including excavation and earth work, concrete work 3mm thick MS sheet cover with locking arrangement hinges and handle rendering work, painting to all steel surfaces with two coats red oxide primer complete and all as directed and including demolition of existing damaged valve pit and removing all as specified and as directed.
M&L construction of brick masonery valve pits of size1200x1200x1200mm internal diamension with brick work in cement mortar (1:4) including excavation and earth work, concrete work 3mm thick MS sheet cover with locking arrangement hinges and handle rendering work, painting to all steel surfaces with two coats red oxide primer complete and all as directed and including demolition of existing damaged valve pit and removing all as specified and as directed.
PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of motor, pump, header etc complete all as specified and directed.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of motor, pump, header etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of motor, pump, header etc, including necessary form work complete all as specified and directed
S&F in replacement of double flanged sluice valve of size 80 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubbersheet nut, bolts and washers complete
S&F in replacement of double flanged sluice valve of size 150 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubbersheet nut, bolts and washers complete
S&F in replacement of double flanged sluice valve of size 100 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubbersheet nut, bolts and washers complete
S&F in replacement of double flanged sluice valve of size 50 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubbersheet nut, bolts and washers complete
M & L GI flange joint 150 mm bore 6/8 holes with rubber packing ring using suitable size nuts, bolts and washers, welding work complete to join two pipe all as specified and as directed .
All as per item No 19 but 100 mm dia
All as per item No 19 but 80 mm dia
S&F in replacement of double flanged Non return valve of size 150 mm bore including replacement of worn out rubbersheet nut, bolts and washers complete.
S&F in replacement of double flanged Non return valve of size 100 mm bore including replacement of worn out rubbersheet nut, bolts and washers complete.
S&F in replacement of Air release valve of size 150mm double flanged including taking down old unserviceable complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fix in replacement of GI Union of following sizes incl taking down old unsv ,complete all as specified and directed.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Supply and fix in replacement of GI Elbow of following sizes incl taking down old unsv ,complete all as specified and directed.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Supply and fix in replacement of GI Socket of following sizes incl taking down old unsv ,complete all as specified and directed.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Supply and fix in replacement of GI nipple of size 15mm x 50 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI nipple of size 15mm x 100 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI nipple of size 15mm x 150 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI nipple of size 20mm x 50 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI nipple of size 20mm x 100 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI nipple of size 20mm x 150 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI nipple of size 25mm x 50 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI nipple of size 25mm x 100 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee of size 15mm x 15mm x 15mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee of size 20mm x 20mm x 20mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee of size 25mm x 25mm x 25mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 20 mm x 15mm x 20 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 25 mm x 15mm x 25 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 25 mm x 20mm x 25 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 20 mm x 25mm x 20 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 15 mm x 20mm x 15 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 40 mm x 20mm x 40 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 40 mm x 25mm x 40 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 50 mm x 20mm x 50 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 50 mm x 25mm x 50 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Tee Reducer of size 50 mm x 15mm x 50 mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 50 mm x 25mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 50 mm x 20mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 50 mm x 15mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 40 mm x 15mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 40 mm x 20mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 40 mm x 25mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 25 mm x 15mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 25 mm x 20mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Elbow reducer of size 20 mm x 15mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Socket reducer of size 50 mm x 25mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Socket reducer of size 50 mm x 20mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Socket reducer of size 40 mm x 15mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Socket reducer of size 40 mm x 20mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Socket reducer of size 40 mm x 25mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Socket reducer of size 25 mm x 20mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Socket reducer of size 25 mm x 15mm incl taking down old unsv ,complete all as specified and directed.
Supply and fix in replacement of GI Socket reducer of size 20 mm x 15mm incl taking down old unsv ,complete all as specified and directed.
Material and labour for Brick Work with sub class B Bricks Straight or Curved or plan to any radius in cement mortar (1:4) for construction/ repair of Drain/Gully Trap.complete all as directed by Engineer in Charge.
Material and Labour required for making hole in RCC roof for passing Pipe line and refilling the same with Cement Concrete (1:2:4) type B-1 using 20mm graded aggregate complete all as directed by Engineer in Charge.
Supply and fixing Digital water level indicator comprising micro controller IC ,buzzer for over flow indication suitable for digital water indicator micro processor based and Magnetic sensor suitable for micro processor based digital water level indicator fixed at different levels inside sump/ over head reservoir for sensing level of water.
PVC insulated copper conductor cable, 12 core x 0.6mm gauge, superior quality suitable for carrying signals from sensor to digital water level indicator of approved make including taking down existing un-serviceable cable all as specified and directed
M & L for preventive maintenance of 75 HP motor pump sets by cleaning stator, rotor and servicing of pumpsets by replacing old gland packing, greasing in bearings etc and preparation of old painted surface and applying one coat of painting, complete including dismantling/separating of motor from pump and rexing the same after servicing complete all as specified and as directed.
All as per item No.71 above but 50 HP pump set complete all as directed and specified.
All as per item No.71 above but 40 HP pump set complete all as directed and specified.
All as per item No.71 above but 30 HP pump set complete all as directed and specified.
All as per item No.71 above but 20 HP pump set complete all as directed.
All as per item No.71 above but 15 HP pump set complete.
All as per item No.71 above but 71 HP pump set complete.
All as per item No.71 above but 5HP pump set complete all as directed.
S&F water pressure meter (measuring in Bar/psi) with necessary cutting, fitting and fixtures and excavation as required, testing and commissioning, complete all as specfied and directed.
Material and labour for attending break down maintenance of pumping line CI/DI/MS/GI upto 150 mm dia) IN aor 15 FAD including necessary earth work to a depth not exceeding 1.2 meter wherever as required using JCB/ Manual according to the site condition and making good the distrubed surfaces / road cuttings by refilling and removing surplus soil to a distance complete all as directed and specified. (a) The contractor shall supply any kind of tools & machinery required for the completion of job. (b) Execution of work / attending break down may also occur in the civil area / road crossing. Therefore the quoted rate is deemed to be inclusive of any precautionery measures while working on public places and strict adherence to the norm as applicables.
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 50 HP from Ghandeerah pump house complete all as specified and directed by Engr -in- Charge.
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 15 to 75 HP from Post 12 Pump house and BOOSTER complete all as specified and directed by Engr -in- Charge.
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 30HP from Tawi River Pump House complete all as specified and directed by Engr -in- Charge.
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 5 HP from SHED 103 and SHED 118 AC Plant complete all as specified and directed by Engr -in- Charge.
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 10 HP from Bansoo Pump House and Tawi River Pump House Plant complete all as specified and directed by Engr -in- Charge.
Note for (item 20 to 24) :- (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The motor shall be squirrel cage induction/slipring induction motor. (c) The contractor shall reinstall the motor within one week after handing over for repairs failing which a penalty @ Rs. 1000/- per day of delay will be charged from the contractor. (d) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of motor duly functional and testing at its original location/position complete all as specified and directed. (e) Replacement of unserviceable bearings and greasing them completely. Bearing shall shall be measured and paid separately. (f) Motor shall be dismantled at workshop in presence of JE concern and inspected by the Engineer -in-Charge. A repair note shall be prepared by the contractor which shall be signed by contractor, JE, EIC and counter signed by GE. Winding cut shall be made in presence of EIC.
Taking down unserv motor and Rewinding the motor rotor with super enamelled copper winding wire/strip as per existing size and truns etc including all the insulating materials i.e varnish, cotton tape insulating paper and soldering etc of motor capacity 75 to 40 HP complete all as specified and directed by Engr-in-Charge.
Removal of winding the motor rotor with super enamelled copper winding wire/strip as per existing size and truns etc including all the insulating materials i.e varnish, cotton tape insulating paper and soldering etc of motor capacity 30 to 15 HP complete all as specified and directed by Engr-in-Charge.
Removal of winding the motor rotor with super enamelled copper winding wire/strip as per existing size and truns etc including all the insulating materials i.e varnish, cotton tape insulating paper and soldering etc of motor capacity 10 to 5 HP complete all as specified and directed by Engr-in-Charge.
Note(86 to 88) :- (a) Winding cut shall be made in presence of EIC and reassembling shall be done after inspection by the EIC. (b) Rewinding wire of motor will be measured and paid separately under relevent item. (c) The motor shall be squirrel cage induction/slipring induction motor.
M&L copper for Rewinding the motor stator with super enamelled copper winding wire of existing size and gauge and truns etc including all the insulating materials i.e varnish with suppr high quality of cotton tape, insulating paper and other misc items of motor any capacity all as specified and directed by Engr-in-Charge.
S&F Angle iron guard rail of welded with M.S Angle iron 50x50x5 mm, MS flat 50x4 mm for interlocking arrangements all as specified and directed.
M&L for cleaning of semi under ground sump by scraping/removing all funges, scales, dust, sludge etc from inside of the semi under ground tank and depositing the same to a distance exc 50 mtrs and n.exc. 100 mtrs including washing the walls & bottom of the over head tank with water and disinfection chemical such as bleaching powder etc and writing date of cleaning, with synthetic enamel black/white paint complete for upto 100000 gallons capacity complete all as specified and directed. (Kali Mata tank)
M&L for cleaning of under ground sump by scraping/removing all funges, scales, dust, sludge etc from inside of tank and depositing the same to a distance exc 50 mtrs and n.exc. 100 mtrs including washing the walls & bottom of the over head tank with water and disinfection chemical such as bleaching powder etc and writing date of cleaning, with synthetic enamel black/white paint complete for 40000 Ltrs capacity complete all as specified and directed. (Gandira)
All as per item No 92 above but of capacity 35000 ltr (Location -Gandira water point)
All as per item No 92 above but of capacity 10000 Ltrs (Location Tawi river Pump House)
All as per item No 92 above but of capacity 5000 Ltrs (Location Bansoo Pump House)
All as per item No 92 above but of capacity 50000 Ltrs (Location Post No-12 pump house
All as per item No 92 above but of Collection tank capacity 50000 Ltrs (Location- Post no -12 Pump House )
All as per item No 92 above but of collection tank capacity 30000 Ltrs (Location- Post no -12 Pump House )
All as per item No 92 above but of capacity 1,25,000 Ltrs (Location-Booster pump house)
All as per item No 92 above but of capacity 1,12,500 Ltrs (Location-Booster pump house)
All as per item No 92 above but of capacity 2,25,000 Ltrs (Location-Booster pump house clearifluctor tank)
All as per item No 92 above but of SMC Tank capacity 50000 Ltrs (Location-Bansoo pump and Ghandira Terra Top)
All as per item No 92 above but of SMC Tank capacity 30000 Ltrs (Location-Ghandira Terra Top)
All as per item No 92 above but of PVC Tank capacity 10000 Ltrs (Location- Ghandira Terra Top)
All as per item No 92 above but of Alum Chamber and Vessel Chamber (Location- Clarifoculator tank Booster)
Scrapping and Preparation and painting of surface of siluce valve/air valve/NRV any size 50 mm to 150 mm bore and applying one coat of synthetic enamel paint of black colour complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement of sets of bearings for 5 to 15 HP H.P motor of end carriage drive complete all as specified and directed.
All as per item No 107 above but bearing for 20 to 30 HP pump/motor
All as per item No 107 above but bearing for 40 to 75 HP pump/motor
Supply and fixing star rubber coupling. Make : Lovejoy L-190.
Supply and fixing Pump seal.
Supply and fixing bearing sleeves.
Supply and fixing Round rubber coupling no 14-8
Overhauling and repairing and servicing for Impeller of suitable existing size made of brass/CI complete all as specified and directed at site by engr-in-charge.
Supply and fix in repairs gland bushing made of stainless steel suitable for 50 to 75 HP pump set, type-centrifugal etc complete all as specified and directed.
Supply and fix in repairs gland bushing made of stainless steel suitable for 40 to 30 HP pump set, ttype-centrifugal etc complete all as specified and directed.
Supply and fix in repairs gland bushing made of stainless steel suitable for 20 to 10 HP pump set ,type-centrifugal etc complete all as specified and directed.
Repair and Maint of automatinc star delta starter, decarbonised of all contects, relay,thimbles etc and cleaning, making good, tightning of all cables, wires and other connected items oiling in moving macnisiam etc incl replacement of burnt parts as requirment basis all as specified and directed for 75 starter complete all as specified and directed .
Repair and Maint of automatinc star delta starter, decarbonised of all contects, relay,thimbles etc and cleaning, making good, tightning of all cables, wires and other connected items oiling in moving macnisiam etc incl replacement of burnt parts as requirment basis all as specified and directed for 50HP starter complete all as specified and directed .
Repair and Maint of automatinc star delta starter, decarbonised of all contects, relay,thimbles etc and cleaning, making good, tightning of all cables, wires and other connected items oiling in moving macnisiam etc incl replacement of burnt parts as requirment basis all as specified and directed for 40 to15 HP starter complete all as specified and directed .
Supply only Flat water proof submersible cable 3 core copper conductor, PVC insulated 1100 volts grade stranded 10 Sqmm , ISI marked and connected to pump motor through water tight sealing joints complete all as specified.
M&L for cleaning of semi under ground sump by scraping/removing all funges, scales, dust, sludge etc from inside of the semi under ground tank and depositing the same to a distance exc 50 mtrs and n.exc. 100 mtrs including washing the walls & bottom of the over head tank with water and disinfection chemical such as bleaching powder etc and writing date of cleaning, CA No and name of contractor with synthetic enamel black/white paint complete for 50000 gallons capacity complete all as specified and directed. (Kali Mata stand by tank)
Supply & Fixing in replacement of Single phase preventer for motor capacity 10HP
Supply & fixing in repair of digital panel mounted AC Amp meter, three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 incl current transformer suitable size complete all as specified and directed .
Supply & fixing in repair of digital panel mounted AC Volt meter , three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 complete all as specified and directed .
Servicing , repairing and over hauling of flaculator including replacement of chain and gear box including oiling greasing and making good as serviceable condition all as specified and directed ( Note :- repairing of flaculator for both tank sedimentation and pre sedimentation tank seperatly)
Servicing repairing and over hauling of slip ring for flaculator all as specified and directed.
Painting and Preparation of surface of steel section incl complete moving bridge and structure of clarifloculator tank and applying two coat after rubbing of rusted surface of synthetic enamel paint including marking all sign of requisite colour complete all as specified and directed by Engr-in-Charge
Repairing of clarifloculator rubber pading (wheel), bearing, chain, motor and overhauling complete and cleaning well maintained all as specified and directed Note rubber padding taken seperately
Replacement of rubber padding of clarifloculator all as specified and directed
Painting of pump motor set, pump etc of applying two coat of synthetic enamel paint after rubbing of rusted surface including marking all sign of requisite colour complete all as specified and directed by Engr-in-Charge
PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of motor, pump, header,in surface channel and Drains etc complete all as specified and directed.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of motor, pump, header etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of motor, pump, header ,Drain etc, including necessary form work complete all as specified and directed
M&L for cleaning of filter bed of MS tank and replacement of filter bed media from chamber at filteration plant jindrah including draining out muddy water from tank and removing all other foreign material like scales, sludges, slit etc and depositing where directed and cleaning tank by washing soda scrapping internal wall surface of water tank using hair brush and wooden blades , including changing of gravels by removing old utilised gravel complete all as directed by engr-in-charge. Note Gravels will be Paid Seperately
Material and labour for Fine Sand Gravel for Filter Bed at Booster Pump House complete all as directed by engr-in-charge.
Supply & Fixing ML - 3 Type three Pole Power contactor having 02 NC & 02 NO auxilary contacts, AC operated of coil voltage 230 Volt, 50 Hz AC 3 rating 40 A, ACI Rating 45A complete all as specified and directed.Cat no. SS90721 of Make - L&T or its equivalent in Havells/ Legrand/Schneider as approved by GE
Supply & Fixing ML - 4 Type three Pole Power contactor having 02 NC & 02 NO auxilary contacts, AC operated of coil voltage 230 /415 Volt, 50 Hz AC 3 rating 70 A, ACI Rating 100A Cat no. SS90910 of Make - L&T or its equivalent in Havells/ Legrand/Schneider as approved by GE
M&L for dismantling the PCC foundation through breaker/Hand Drill/Manually etc incl proper taking down the motor and pump alongwith channel, disconnecting the suction and delivery pipe. Note- PCC will be measured im seperated items
Material and labour for writing SM/MES no/Location etc on Pump and Motor Set, Generator, Header,and Date of cleaning on tank complete all as directed by the Engineer-in-Charge
Material and Labour for cleaning of Drain of (Width 0.5 mtr and Depth 0.8 mtr) from Drain Chamber at Booster to Drain Line near Shed complete all as directed by Engineer in Charge.
Demolition of cement concrete complete all as directed by Engineer in Charge.
Demolition of brick work complete all as directed by Engineer in Charge.
Material and labour for Brick Work with sub class B Bricks Straight or Curved or plan to any radius in cement mortar (1:4) for construction and repair of Drain.complete all as directed by Engineer in Charge.
Material and labour for Brick Work with sub class B Bricks (Except Brick) Straight or Curved or plan to any radius in cement mortar (1:4) for construction and repair of Drain.complete all as directed by Engineer in Charge.
Material and labour for plastering on fair faces of Brick Work with 15mm thick cement plaster (1:4) complete all as directed by Engineer in Charge. Note- WPC will be paid Seperately.
Material and Labour for cement concrete using type C-2 ( 1 : 3 :6) using 40mm graded aggregrate in surface channel and Drains
Supply only Integral Water Proofing Compound
Deduct Schedule of Credit of Rs. (-) 135952.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
DAVINDER SINGH
K S BUILDERS
SUBASH CHANDER
LUXMI ELECTRONIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .